Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38935005

ABSTRACT

INTRODUCTION: This study evaluated the probability of developing malocclusions in mixed dentition. METHODS: A longitudinal study was conducted with 598 children (aged 5 years) in deciduous dentition. The children were followed for 3 years until mixed dentition (aged 8 years). Overjet, overbite, and transversal relations were evaluated. Bayesian models were used to analyze the data and estimate the parameters. RESULTS: The parameter θ was used for the distributions, indicating the probability of presenting a given condition with a credibility index (ICr) of 95%. After 3 years of follow-up, 121 children were reevaluated. The results showed that children have a high probability of malocclusion in mixed dentition. There was a higher probability of developing an increased overjet in the mixed dentition of 20.5% (ICr 95%, 13.6-28.4) to 48.3% (ICr 95%, 39.1-57.7) and a higher probability of having a normal overbite in the deciduous dentition and a lower probability in the mixed dentition (ICr 95%, 9.2-21.3). CONCLUSIONS: Considering the probabilistic model of Bayesian analysis, children with normal overjet in the deciduous dentition may show an increased overjet in the mixed dentition. Concerning overbite, children may present an anterior open bite during the transition between deciduous and mixed dentition, as well as self-correction of deep overbite in mixed dentition. Furthermore, they may present a posterior crossbite during the mixed dentition when there is a normal transverse relationship in the deciduous dentition.

2.
Clin Oral Investig ; 27(11): 6413-6420, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37704914

ABSTRACT

AIM: To assess the observed volume of filled C-shaped root canals from different CBCT and micro-CT having nano-CT as a reference. MATERIALS AND METHODS: Twelve extracted mandibular molars with C-shaped root canals were endodontically treated using Reciproc Blue R25 (VDW GMBH, Munich, Germany) in a reciprocating system and filled with gutta-percha (Dentsply Maillefer) and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). CBCT scans were performed using 3 units-3D Accuitomo 170 (J. Morita, Kyoto, Japan), ProMax 3D Max (Planmeca, Helsinki, Finland), and NewTom VGi EVO (Cefla QR, Verona, Italy)-at two resolution modes: standard and high. Micro-CT and nano-CT scans were also obtained. The volume of all filled C-shaped root canals was obtained using CTAn software (Bruker, Kontich, Belgium), and the blooming artifact, in relation to nano-CT volume, was calculated. The data were evaluated by the Bland-Altman plots and ANOVA two-way for repeated measures (α = 0.05). RESULTS: All CBCT units and micro-CT showed significantly larger observed volume of root canal filling when compared to nano-CT. The blooming artifact of root canal filling in standard resolution was significantly larger than that in high resolution (p < 0.05) in all CBCT units. CONCLUSIONS: Endodontic filling material with AH Plus sealer causes blooming artifacts in CBCT units and micro-CT. CLINICAL RELEVANCE: Considering the anatomical complexity of C-shaped root canals and the challenges associated with endodontic treatment, CBCT is frequently recommended for follow-up evaluations. However, the presence of endodontic filling material can result in blooming artifacts that may potentially impact the accurate diagnosis of endodontic complications.


Subject(s)
Root Canal Filling Materials , Dental Pulp Cavity , X-Ray Microtomography , Root Canal Preparation , Retreatment , Gutta-Percha , Root Canal Obturation , Cone-Beam Computed Tomography
3.
Eur J Oral Sci ; 131(4): e12937, 2023 08.
Article in English | MEDLINE | ID: mdl-37212743

ABSTRACT

This study evaluated the influence of different implant diameters, insertion torques, and transmucosal heights on the loosening of abutments installed on short implants, after mechanical cycling. The Morse taper connection implants (n = 96) tested were 5 mm high, divided according to the platform diameter: 4 or 6 mm. A universal abutment was coupled to each implant (with different transmucosal heights: 1 or 5 mm). The sets were subdivided into 20- and 32-Ncm torque. After the cycle fatigue test, the detorque values were measured with a digital torque indicator. After mechanical cycling, the mean detorque values obtained for the abutment with 20-Ncm insertion torque were lower than for implants with 32-Ncm insertion torque, regardless of the platform diameter or transmucosal height. In the 20-Ncm torque group, there was no statistically significant difference in the detorque values between platform diameters or transmucosal heights. Otherwise, for 32-Ncm sets, a smaller platform diameter (4 mm), and a longer transmucosal height (5 mm) showed the lowest detorque values. In conclusion, implants placed with 32-Ncm insertion torque and abutments with 1 mm transmucosal height and a 6 mm implant diameter demonstrated the highest detorque values.


Subject(s)
Dental Implant-Abutment Design , Dental Implants , Torque , Dental Abutments , Materials Testing , Stress, Mechanical , Bone Screws , Dental Stress Analysis
4.
Plant Cell Tissue Organ Cult ; 150(2): 479-485, 2022.
Article in English | MEDLINE | ID: mdl-35313681

ABSTRACT

Continues subculturing of in vitro plant subcultures is essential for commercial micropropagation and tissue culture research. In unusual situations, the subcultures can be delayed, and the slow-growth in vitro storage technic could be applied to reduce the loss of plant material. The present study aimed to evaluate the slow-growth in vitro storage of banana plantlets ('Prata Catarina'; group AAB) under different light spectra. Shoot cultures in MS medium without plant growth regulators were maintained under blue (B), red (R), red plus blue (R2B), and white (CW) light spectra (25 °C ± 2 °C; 50 µmol m-2 s-1) for up to 140 days. The plantlets maintained under the R, CW, and R2B spectra suffered severe root damage and browning after 140 days of in vitro slow-growth storage (SGS). All plantlets maintained under the B spectrum survived after 140 days of in vitro SGS and showed little browning.

SELECTION OF CITATIONS
SEARCH DETAIL