Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 283
Filter
1.
Scand J Med Sci Sports ; 34(9): e14731, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39308061

ABSTRACT

Carbohydrates are critical for high-intensity exercise performance. However, the effects of carbohydrate supplementation on muscle metabolism and performance during short-duration high-intensity intermittent exercise remain inadequately explored. Our aim was to address this aspect in a randomized, counterbalanced, double-blinded crossover design. Eleven moderately-to-well-trained males performed high-intensity intermittent cycling receiving carbohydrate (CHO, ~55 g/h) or placebo (PLA) fluid supplementation. Three exercise periods (EX1-EX3) were completed comprising 10 × 45 s at ~105% Wmax interspersed with 135 s rest between bouts and ~20 min between periods. Repeated sprint ability (5 × 6 s sprints with 24 s recovery) was assessed at baseline and after each period. Thigh muscle biopsies were obtained at baseline and before and after EX3 to determine whole-muscle and fiber-type-specific glycogen depletion. No differences were found in muscle glycogen degradation at the whole-muscle (p = 0.683) or fiber-type-specific level (p = 0.763-0.854) with similar post-exercise whole-muscle glycogen concentrations (146 ± 20 and 122 ± 15 mmol·kg-1 dw in CHO and PLA, respectively). Repeated sprint ability declined by ~9% after EX3 with no between-condition differences (p = 0.971) and no overall differences in ratings of perceived exertion (p = 0.550). This was despite distinctions in blood glucose concentrations throughout exercise, reaching post-exercise levels of 5.3 ± 0.2 and 4.1 ± 0.2 mmol·L-1 (p < 0.001) in CHO and PLA, respectively, accompanied by fivefold higher plasma insulin levels in CHO (p < 0.001). In conclusion, we observed no effects of carbohydrate ingestion on net muscle glycogen breakdown or sprint performance during short-duration high-intensity intermittent exercise despite elevated blood glucose and insulin levels. These results therefore question the efficacy of carbohydrate supplementation strategies in high-intensity intermittent sports.


Subject(s)
Athletic Performance , Cross-Over Studies , Dietary Carbohydrates , Glycogen , Muscle, Skeletal , Humans , Male , Glycogen/metabolism , Dietary Carbohydrates/administration & dosage , Double-Blind Method , Muscle, Skeletal/metabolism , Muscle, Skeletal/physiology , Athletic Performance/physiology , Young Adult , Adult , High-Intensity Interval Training , Blood Glucose/metabolism , Insulin/blood , Dietary Supplements , Bicycling/physiology
2.
Eur J Pain ; 2024 Aug 08.
Article in English | MEDLINE | ID: mdl-39116004

ABSTRACT

BACKGROUND: Spatial acuity concerns the ability to localize and discriminate sensory input and is often tested using the two-point discrimination threshold (2PDT). Sensitization of the pain system can affect the spatial acuity, but it is unclear how 2PDTs of different testing modalities are affected. The aim was to investigate if the 2PDTs for mechanical and heat stimulation at different intensities were modulated by topical capsaicin sensitization. METHODS: 30 healthy subjects were divided into either a capsaicin or a placebo group. The 2PDT was tested using two different modalities, mechanical and thermal (laser) delivered at innocuous and noxious intensities. The 2PDT were determined at baseline and re-assessed 48 h later. In the follow-up session, the subjects either had a capsaicin patch (8%) or placebo patch placed in the testing area for 30 min before re-testing the 2PDT. RESULTS: The 2PDT was highly dependent on stimulation modality and intensity. The lowest 2PDT was found for innocuous mechanical stimuli (40.0 mm, 95% CI 38.1-41.9 mm), and the highest 2PDT was found for innocuous thermal stimuli (81.7 mm, 95% CI 73.9-89.5 mm). Topical capsaicin generally increased the 2PDT, but this was only significant for innocuous mechanical stimuli. The perceived intensity of the stimuli was increased following capsaicin and was generally higher for noxious stimuli than for innocuous stimuli (ANOVA, p < 0.001). CONCLUSIONS: This study showed that capsaicin provoked pain sensitization increased the 2PDT. The 2PDT tested using innocuous mechanical stimuli showed less variable results indicating that this test is most suitable to detect this aspect of spatial acuity. SIGNIFICANCE STATEMENT: This study investigated how the two-point discrimination threshold (2PDT) can be modulated by topical capsaicin. The 2PDT was assessed for two different modalities (thermal and mechanical) and for two different intensities (innocuous and noxious) before and after capsaicin. The results showed that the 2PDT was generally impaired following capsaicin, but this was only significant for mechanical innocuous stimuli. Furthermore, it was shown that mechanical innocuous stimuli assessed the 2PDT with lower variability than other combinations.

3.
Eur J Pain ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980214

ABSTRACT

BACKGROUND: Commonly used models for eliciting muscle pain involve the injection of algesic substances or the induction of delayed onset muscle soreness. The former require invasive procedures, and the time frame for pain induction and subsidence in the latter can be inconvenient. This study presents a detailed spatiotemporal characterization of a new experimental model of muscle pain based on short-wave diathermy (SWD), developed to overcome the limitations of existing models. METHODS: The shoulder was selected as target site and the effects of the model were tested in two sessions to assess its reliability. Pain intensity profiles were recorded during the application of SWD, and changes in pressure pain threshold (PPT) in the infraspinatus muscle, together with pain intensity, duration, and quality were assessed 30 min after induction. RESULTS: SWD-induced pain intensity scores averaged 4 points on a visual analogue scale, whereas PPT showed a consistent decrease of about 25% relative to baseline values. Pain was localized in the shoulder area, and was described as continuous, dull, well-delimited, heavy, and bearable. Pain lasted for an average of 145 min without requiring reinduction and was reliably elicited in both experimental sessions. CONCLUSION: SWD can be used to elicit experimental muscle pain in a non-invasive, long-lasting, and reliable way and allows for repeated within- and between-session testing in the shoulder. SIGNIFICANCE STATEMENT: SWD produces deep heating in muscles by converting electromagnetic energy to thermal energy. It was previously shown that it can be used to elicit experimental pain in the forearm muscles, and the present study demonstrates that this can be reliably generalized to other body sites, such as the shoulder. Furthermore, SWD application is non-invasive and presents a convenient time frame for pain induction and subsidence, thus overcoming limitations associated with traditional muscle pain models.

4.
Clin Exp Dent Res ; 10(4): e903, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39031165

ABSTRACT

OBJECTIVES: To explore the antimicrobial potential of strontium (Sr)-functionalized wafers against multiple bacteria associated with per-implant infections, in both mono- and multispecies biofilms. MATERIALS AND METHODS: The bactericidal and bacteriostatic effect of silicon wafers functionalized with a strontium titanium oxygen coating (Sr-Ti-O) or covered only with Ti (controls) against several bacteria, either grown as a mono-species or multispecies biofilms, was assessed using a bacterial viability assay and a plate counting method. Mono-species biofilms were assessed after 2 and 24 h, while the antimicrobial effect on multispecies biofilms was assessed at Days 1, 3, and 6. The impact of Sr functionalization on the total percentage of Porphyromonas gingivalis in the multispecies biofilm, using qPCR, and gingipain activity was also assessed. RESULTS: Sr-functionalized wafers, compared to controls, were associated with statistically significant less viable cells in both mono- and multispecies tests. The number of colony forming units (CFUs) within the biofilm was significantly less in Sr-functionalized wafers, compared to control wafers, for Staphylococcus aureus at all time points of evaluation and for Escherichia coli at Day 1. Gingipain activity was less in Sr-functionalized wafers, compared to control wafers, and the qPCR showed that P. gingivalis remained below detection levels at Sr-functionalized wafers, while it consisted of 15% of the total biofilm on control wafers at Day 6. CONCLUSION: Sr functionalization displayed promising antimicrobial potential, possessing bactericidal and bacteriostatic ability against bacteria associated with peri-implantitis grown either as mono-species or mixed in a multispecies consortium with several common oral microorganisms.


Subject(s)
Biofilms , Peri-Implantitis , Porphyromonas gingivalis , Strontium , Titanium , Titanium/chemistry , Titanium/pharmacology , Biofilms/drug effects , Peri-Implantitis/microbiology , Peri-Implantitis/drug therapy , Strontium/pharmacology , Porphyromonas gingivalis/drug effects , Humans , Anti-Bacterial Agents/pharmacology , Coated Materials, Biocompatible/pharmacology , Coated Materials, Biocompatible/chemistry , Microbial Viability/drug effects , Dental Implants/microbiology
5.
Zoonoses Public Health ; 71(5): 560-567, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38769642

ABSTRACT

AIMS: Salmonella infections are significant causes of foodborne outbreaks in the European Union. This study investigates a sudden increase in gastroenteritis patients in the hospital district of Central Finland in June 2021. The primary aim was to study the outbreak's magnitude and source of the outbreak. METHODS AND RESULTS: Epidemiological, microbiological, environmental and traceback investigations were conducted. Over 700 persons fell ill during the outbreak caused by Salmonella Typhimurium associated with a daycare lunch. Similar S. Typhimurium was found in the patients and a vegetable mix containing iceberg lettuce, cucumber and peas served during lunch. The traceback investigation revealed that the batch information of vegetables from the wholesaler was not complete. The wholesaler had received quality complaints about the iceberg lettuce from the central kitchen. The manufacturer did not test the suspected batch for Salmonella since the production plant had given a certificate declaring it Salmonella negative. CONCLUSIONS: The most suspect ingredient was one batch of iceberg lettuce due to quality complaints. The lettuce had not been served in two daycare centres without cases. We recommend that in order to enable thorough microbiological investigation, institutional kitchens store the food samples separately as part of the internal quality control and that food items should always be tested when Salmonella contamination in an outbreak is suspected.


Subject(s)
Salmonella typhimurium , Vegetables , Finland/epidemiology , Foodborne Diseases/epidemiology , Gastroenteritis/epidemiology , Lactuca/microbiology , Cucumis sativus/microbiology , European Union , Humans , Child Day Care Centers , Infant , Child, Preschool , Child , Adolescent , Young Adult , Adult , Middle Aged , Food Analysis , Vegetables/microbiology
6.
Eur J Pain ; 28(8): 1320-1329, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38440936

ABSTRACT

BACKGROUND: Cutaneous laser stimulation has commonly been employed to investigate the thermal properties of the nociceptive system. The aim of this study was to investigate how a temperature-controlled laser system improves the assessment of directional discrimination in the nociceptive system. METHODS: In total, twenty healthy volunteers participated in this study. To determine the directional discrimination threshold (stimulation length 50% correct, expressed in mm), thermal stimuli were delivered using a diode laser and the laser beam was perpendicularly displaced across the skin to give a linear stimulation in four different directions (distal, proximal, lateral and medial) and displacement lengths (3 for lateral-medial and 5 for distal-proximal). Two temperature control modes were used in the stimulation system, open-loop and closed-loop control. The subjects had to report the perceived stimulus direction, the degree of certainty regarding the perceived direction and the intensity of the perceived stimulus (0-10 numerical rating scale, 3: pain threshold). RESULTS: During closed-loop control, the orientation of stimuli was discriminated significantly more accurately than during open-loop control. During closed-loop control, the directional discrimination threshold was 31.9 and 26.1 mm for distal-proximal and lateral-medial directed stimuli, respectively. A numerical rating scale was significantly higher for the lateral/medial directions. Moreover, the variability of the discrimination threshold is reduced in the closed-loop control system. CONCLUSIONS: The findings show that discrimination ability is better in the lateral-medial directions compared to the distal-proximal directions. This study indicates that using a system enabling closed-loop temperature control, allows more robust probing of the temporo-spatial mechanisms in the nociceptive system. SIGNIFICANCE: This study shows that a newly developed temperature-controlled laser stimulation system enhances the possibilities to investigate the nociceptive temporo-spatial integration, as shown by a less variable directional discrimination threshold. The results also show that different orthogonal directions are discriminated differently. This new method allows a better investigation of the combined temporal and spatial mechanisms in the nociceptive system.


Subject(s)
Lasers , Nociception , Pain Threshold , Humans , Male , Female , Adult , Pain Threshold/physiology , Nociception/physiology , Young Adult , Discrimination, Psychological/physiology , Pain Measurement/methods , Temperature , Hot Temperature
7.
Nat Commun ; 15(1): 1416, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38360958

ABSTRACT

In recent sea level studies, discrepancies have arisen in ocean mass observations obtained from the Gravity Recovery and Climate Experiment and its successor, GRACE Follow-On, with GRACE estimates consistently appearing lower than density-corrected ocean volume observations since 2015. These disparities have raised concerns about potential systematic biases in sea-level observations, with significant implications for our understanding of this essential climate variable. Here, we reconstruct the global and regional ocean mass change through models of ice and water mass changes on land and find that it closely aligns with both GRACE and density-corrected ocean volume observations after implementing recent adjustments to the wet troposphere correction and halosteric sea level. While natural variability in terrestrial water storage is important on interannual timescales, we find that the net increase in ocean mass over 20 years can be almost entirely attributed to ice wastage and human management of water resources.

8.
Ear Hear ; 45(3): 721-729, 2024.
Article in English | MEDLINE | ID: mdl-38287477

ABSTRACT

OBJECTIVES: Background noise and linguistic violations have been shown to increase the listening effort. The present study aims to examine the effects of the interaction between background noise and linguistic violations on subjective listening effort and frontal theta oscillations during effortful listening. DESIGN: Thirty-two normal-hearing listeners participated in this study. The linguistic violation was operationalized as sentences versus random words (strings). Behavioral and electroencephalography data were collected while participants listened to sentences and strings in background noise at different signal to noise ratios (SNRs) (-9, -6, -3, 0 dB), maintained them in memory for about 3 sec in the presence of background noise, and then chose the correct sequence of words from a base matrix of words. RESULTS: Results showed the interaction effects of SNR and speech type on effort ratings. Although strings were inherently more effortful than sentences, decreasing SNR from 0 to -9 dB (in 3 dB steps), increased effort rating more for sentences than strings in each step, suggesting the more pronounced effect of noise on sentence processing that strings in low SNRs. Results also showed a significant interaction between SNR and speech type on frontal theta event-related synchronization during the retention interval. This interaction indicated that strings exhibited higher frontal theta event-related synchronization than sentences at SNR of 0 dB, suggesting increased verbal working memory demand for strings under challenging listening conditions. CONCLUSIONS: The study demonstrated that the interplay between linguistic violation and background noise shapes perceived effort and cognitive load during speech comprehension under challenging listening conditions. The differential impact of noise on processing sentences versus strings highlights the influential role of context and cognitive resource allocation in the processing of speech.


Subject(s)
Speech Perception , Humans , Noise , Linguistics , Hearing Tests , Memory, Short-Term
9.
Med Sci Sports Exerc ; 56(5): 902-916, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38181220

ABSTRACT

PURPOSE: Short periods of reduced energy availability are commonly undertaken by athletes to decrease body mass, possibly improve the power-to-mass ratio, and enhance physical performance. Our primary aim was to investigate the impact of 10 d of low energy availability (LEA) followed by 2 d of optimal energy availability (OEA) on physical performance parameters in trained females. Second, physiological markers at the whole-body and molecular level related to performance were evaluated. METHODS: Thirty young trained eumenorrheic females were matched in pairs based on training history and randomized to a 10-d intervention period of LEA (25 kcal·fat-free mass (FFM) -1 ·d -1 ) or OEA (50 kcal·FFM -1 ·d -1 ) along with supervised exercise training. Before the intervention, participants underwent a 5-d run-in period with OEA + supervised exercise training. After the LEA intervention, 2 d of recovery with OEA was completed. Participants underwent muscle biopsies, blood sampling, physical performance tests, body composition measurements, and resting metabolic rate measurements. A linear mixed model was used with group and time as fixed effects and subject as random effects. RESULTS: Compared with OEA, LEA resulted in reduced body mass, muscle glycogen content, repeated sprint ability, 4-min time-trial performance, and rate of force development of the knee extensors (absolute values; P < 0.05). Two days of recovery restored 4-min time-trial performance and partly restored repeated sprint ability, but performance remained inferior to the OEA group. When the performance data were expressed relative to body mass, LEA did not enhance performance. CONCLUSIONS: Ten days of LEA resulted in impaired performance (absolute values), with concomitant reductions in muscle glycogen. Two days of recovery with OEA partially restored these impairments, although physical performance (absolute values) was still inferior to being in OEA. Our findings do not support the thesis that LEA giving rise to small reductions in body mass improves the power-to-mass ratio and thus increases physical performance.


Subject(s)
Body Composition , Exercise , Humans , Female , Exercise/physiology , Glycogen/metabolism , Energy Metabolism/physiology , Energy Intake/physiology
10.
Clin Exp Dent Res ; 10(1): e812, 2024 02.
Article in English | MEDLINE | ID: mdl-38044566

ABSTRACT

OBJECTIVES: To investigate the impact of a Ti-Sr-O technology, applied to either a turned surface or an SLA surface, on the mechanical robustness of osseointegration, benchmarked against the SLActive surface. MATERIAL AND METHODS: Ti discs (6.25-mm-diameter and 2-mm-thick) with three different surfaces were inserted on the proximal-anterior part of the tibial plateau of adult Swedish loop rabbits: (I) turned surface modified with Ti-Sr-O (turned + Ti-Sr-O), (II) SLA surface modified with Ti-Sr-O (SLA + Ti-Sr-O), and (III) SLActive surface (SLActive). Following a healing period of 2 weeks and 4 weeks, the pull-out (PO) force needed to detach the discs from the bone was assessed, as a surrogate of osseointegration. RESULTS: The SLActive surface exhibited statistically significant higher median PO forces, compared with the SLA + Ti-Sr-O surfaces at both 2- and 4 weeks post-op (p > .05). In this study, no single turned + Ti-Sr-O surface disk was integrated. CONCLUSIONS: The tested Ti-Sr-O technology failed to enhance osseointegration; however, this finding may be related to the inappropriateness of the rabbit tibia plateau model for assessing third-generation implant surface technologies, due to the limited diffusion and clearance at the disk-bone interface.


Subject(s)
Dental Implants , Osseointegration , Oxides , Titanium , Animals , Rabbits , Tibia/surgery , Surface Properties , Strontium
11.
Eur J Neurosci ; 58(11): 4357-4370, 2023 12.
Article in English | MEDLINE | ID: mdl-37984406

ABSTRACT

Listening effort can be defined as a measure of cognitive resources used by listeners to perform a listening task. Various methods have been proposed to measure this effort, yet their reliability remains unestablished, a crucial step before their application in research or clinical settings. This study encompassed 32 participants undertaking speech-in-noise tasks across two sessions, approximately a week apart. They listened to sentences and word lists at varying signal-to-noise ratios (SNRs) (-9, -6, -3 and 0 dB), then retaining them for roughly 3 s. We evaluated the test-retest reliability of self-reported effort ratings, theta (4-7 Hz) and alpha (8-13 Hz) oscillatory power, suggested previously as neural markers of listening effort. Additionally, we examined the reliability of correct word percentages. Both relative and absolute reliability were assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. We also computed the standard error of measurement (SEM) and smallest detectable change (SDC). Our findings indicated heightened frontal midline theta power for word lists compared to sentences during the retention phase under high SNRs (0 dB, -3 dB), likely indicating a greater memory load for word lists. We observed SNR's impact on alpha power in the right central region during the listening phase and frontal theta power during the retention phase in sentences. Overall, the reliability analysis demonstrated satisfactory between-session variability for correct words and effort ratings. However, neural measures (frontal midline theta power and right central alpha power) displayed substantial variability, even though group-level outcomes appeared consistent across sessions.


Subject(s)
Listening Effort , Speech Perception , Humans , Self Report , Reproducibility of Results , Noise
12.
Clin Exp Dent Res ; 9(6): 1004-1008, 2023 12.
Article in English | MEDLINE | ID: mdl-37905711

ABSTRACT

The purpose of this technical report is to present two novel experimental implant designs to boost data generation in preclinical in vivo research. Specifically, the report describes the rationale and the components of (1) a two-piece experimental implant suitable for a small animal platform (e.g., the rabbit femur/tibial epiphysis model), consisting of a threaded apical- and a coronal cylindrical piece, which is intended for collecting two types of biomechanical data, and (2) a three-piece experimental implant suitable for a large animal platform (e.g., the mini-pig mandible model), consisting of an apical "wound chamber", which allows the collection of histological/histomorphometrical data, and a middle threaded and coronal cylindrical piece, which also allow the collection of two types of biomechanical data. The increased volume of information generated from a single experiment in a small animal platform, using the proposed two-piece implant design, may assist in a more qualified decision-making process, on whether it is relevant to proceed to further assessment using a large animal platform. Furthermore, the increased volume of information generated in a single animal experiment either in a small or large animal platform, using the proposed two- and three-piece implants, respectively, likely decreases the number of animals otherwise needed for collecting the same information with standard one-piece implants and, thus, contributes to the reduction/refinement elements of the 3R principle.


Subject(s)
Dental Implants , Animals , Swine , Rabbits , Dental Prosthesis Design , Swine, Miniature , Dental Implantation, Endosseous , Mandible/surgery
13.
Front Cell Dev Biol ; 11: 1246998, 2023.
Article in English | MEDLINE | ID: mdl-37745291

ABSTRACT

Adult stem cells play key roles in tissue homeostasis and regeneration. Recent evidence suggests that dietary interventions can significantly impact adult stem cell function. Some of these effects depend on ketone bodies. Adult stem cells could therefore potentially be manipulated through dietary regimens or exogenous ketone body supplementation, a possibility with significant implications for regenerative medicine. In this review we discuss recent findings of the mechanisms by which ketone bodies could influence adult stem cells, including ketogenesis in adult stem cells, uptake and transport of circulating ketone bodies, receptor-mediated signaling, and changes to cellular metabolism. We also discuss the potential effects of ketone bodies on intracellular processes such as protein acetylation and post-transcriptional control of gene expression. The exploration of mechanisms underlying the effects of ketone bodies on stem cell function reveals potential therapeutic targets for tissue regeneration and age-related diseases and suggests future research directions in the field of ketone bodies and stem cells.

14.
Diagnostics (Basel) ; 13(14)2023 Jul 11.
Article in English | MEDLINE | ID: mdl-37510089

ABSTRACT

Deep neural networks are complex machine learning models that have shown promising results in analyzing high-dimensional data such as those collected from medical examinations. Such models have the potential to provide fast and accurate medical diagnoses. However, the high complexity makes deep neural networks and their predictions difficult to understand. Providing model explanations can be a way of increasing the understanding of "black box" models and building trust. In this work, we applied transfer learning to develop a deep neural network to predict sex from electrocardiograms. Using the visual explanation method Grad-CAM, heat maps were generated from the model in order to understand how it makes predictions. To evaluate the usefulness of the heat maps and determine if the heat maps identified electrocardiogram features that could be recognized to discriminate sex, medical doctors provided feedback. Based on the feedback, we concluded that, in our setting, this mode of explainable artificial intelligence does not provide meaningful information to medical doctors and is not useful in the clinic. Our results indicate that improved explanation techniques that are tailored to medical data should be developed before deep neural networks can be applied in the clinic for diagnostic purposes.

15.
J Cogn Neurosci ; 35(8): 1301-1311, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37379482

ABSTRACT

The envelope of a speech signal is tracked by neural activity in the cerebral cortex. The cortical tracking occurs mainly in two frequency bands, theta (4-8 Hz) and delta (1-4 Hz). Tracking in the faster theta band has been mostly associated with lower-level acoustic processing, such as the parsing of syllables, whereas the slower tracking in the delta band relates to higher-level linguistic information of words and word sequences. However, much regarding the more specific association between cortical tracking and acoustic as well as linguistic processing remains to be uncovered. Here, we recorded EEG responses to both meaningful sentences and random word lists in different levels of signal-to-noise ratios (SNRs) that lead to different levels of speech comprehension as well as listening effort. We then related the neural signals to the acoustic stimuli by computing the phase-locking value (PLV) between the EEG recordings and the speech envelope. We found that the PLV in the delta band increases with increasing SNR for sentences but not for the random word lists, showing that the PLV in this frequency band reflects linguistic information. When attempting to disentangle the effects of SNR, speech comprehension, and listening effort, we observed a trend that the PLV in the delta band might reflect listening effort rather than the other two variables, although the effect was not statistically significant. In summary, our study shows that the PLV in the delta band reflects linguistic information and might be related to listening effort.


Subject(s)
Auditory Cortex , Speech Perception , Humans , Speech/physiology , Electroencephalography , Speech Perception/physiology , Auditory Cortex/physiology , Linguistics , Acoustic Stimulation
16.
J Physiol ; 601(16): 3481-3497, 2023 08.
Article in English | MEDLINE | ID: mdl-37329147

ABSTRACT

Low energy availability (LEA) describes a state where the energy intake is insufficient to cover the energy costs of both exercise energy expenditure and basal physiological body functions. LEA has been associated with various physiological consequences, such as reproductive dysfunction. However, the effect of LEA on skeletal muscle protein synthesis in females performing exercise training is still poorly understood. We conducted a randomized controlled trial to investigate the impact of LEA on daily integrated myofibrillar and sarcoplasmic muscle protein synthesis in trained females. Thirty eumenorrheic females were matched based on training history and randomized to undergo 10 days of LEA (25 kcal · kg fat-free mass (FFM)-1  · day-1 ) or optimal energy availability (OEA, 50 kcal · kg FFM-1  · day-1 ). Before the intervention, both groups underwent a 5-day 'run-in' period with OEA. All foods were provided throughout the experimental period with a protein content of 2.2 g kg lean mass-1  · day-1 . A standardized, supervised combined resistance and cardiovascular exercise training programme was performed over the experimental period. Daily integrated muscle protein synthesis was measured by deuterium oxide (D2 O) consumption along with changes in body composition, resting metabolic rate, blood biomarkers and 24 h nitrogen balance. We found that LEA reduced daily integrated myofibrillar and sarcoplasmic muscle protein synthesis compared with OEA. Concomitant reductions were observed in lean mass, urinary nitrogen balance, free androgen index, thyroid hormone concentrations and resting metabolic rate following LEA. These results highlight that LEA may negatively affect skeletal muscle adaptations in females performing exercise training. KEY POINTS: Low energy availability (LEA) with potential health and performance impairments is widespread among female athletes. We investigated the impact of 10 days of LEA on daily integrated myofibrillar and sarcoplasmic muscle protein synthesis in young, trained females. We show that LEA impairs myofibrillar and sarcoplasmic muscle protein synthesis in trained females performing exercise training. These findings suggest that LEA may have negative consequences for skeletal muscle adaptations and highlight the importance of ensuring adequate energy availability in female athletes.


Subject(s)
Energy Metabolism , Muscle Proteins , Humans , Female , Muscle Proteins/metabolism , Energy Metabolism/physiology , Energy Intake , Muscle, Skeletal/metabolism , Nitrogen/metabolism
17.
Clin Oral Investig ; 27(7): 3741-3748, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37269339

ABSTRACT

OBJECTIVES: To examine factors influencing the primary stability of dental implants when stabilized in over-sized osteotomies using a calcium phosphate-based adhesive cement was the objective. METHODS: Using implant removal torque measurements as a surrogate for primary stability, we examined the influence of implant design features (diameter, surface area, and thread design), along with cement gap size and curing time, on the resulting primary implant stability. RESULTS: Removal torque values scaled with implant surface area and increasing implant diameters. Cement gap size did not alter the median removal torque values; however, larger gaps were associated with an increased spread of the measured values. Among the removal torque values measured, all were found to be above 32 Ncm which is an insertion torque threshold value commonly recommended for immediate loading protocols. CONCLUSION: The adhesive cement show potential for offering primary implant stability for different dental implant designs. In this study, the primary parameters influencing the measured removal torque values were the implant surface area and diameter. As the liquid cement prevents the use of insertion torque, considering the relationship between insertion and removal torque, removal torque can be considered a reliable surrogate for primary implant stability for bench and pre-clinical settings. CLINICAL RELEVANCE: At present, the primary stability of dental implants is linked to the quality of the host bone, the drill protocol, and the specific implant design. The adhesive cement might find applications in future clinical settings for enhancing primary stability of implants under circumstances where this cannot be achieved conventionally.


Subject(s)
Dental Implants , Dental Implantation, Endosseous/methods , Dental Prosthesis Design , Bone and Bones , Device Removal , Torque
18.
Scand J Med Sci Sports ; 33(7): 1054-1071, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36932633

ABSTRACT

Performance in short-duration sports is highly dependent on muscle glycogen, but the total degradation is only moderate and considering the water-binding property of glycogen, unnecessary storing of glycogen may cause an unfavorable increase in body mass. To investigate this, we determined the effect of manipulating dietary carbohydrates (CHO) on muscle glycogen content, body mass, and short-term exercise performance. In a randomized and counterbalanced cross-over design, twenty-two men completed two maximal cycle tests of either 1-min (n = 10) or 15-min (n = 12) duration with different pre-exercise muscle glycogen levels. Glycogen manipulation was initiated three days prior to the tests by exercise-induced glycogen depletion followed by ingestion of a moderate (M-CHO) or high (H-CHO) CHO-diet. Subjects were weighed before each test, and muscle glycogen content was determined in biopsies from m. vastus lateralis before and after each test. Pre-exercise muscle glycogen content was lower following M-CHO than H-CHO (367 mmol · kg-1 DW vs. 525 mmol · kg-1 DW, p < 0.00001), accompanied by a 0.7 kg lower body mass (p < 0.00001). No differences were observed in performance between diets in neither the 1-min (p = 0.33) nor the 15-min (p = 0.99) test. In conclusion, pre-exercise muscle glycogen content and body mass were lower after ingesting moderate compared with high amounts of CHO, while short-term exercise performance was unaffected. This demonstrates that adjusting pre-exercise glycogen levels to the requirements of competition may provide an attractive weight management strategy in weight-bearing sports, particularly in athletes with high resting glycogen levels.


Subject(s)
Glycogen , Muscle, Skeletal , Humans , Male , Diet , Dietary Carbohydrates , Exercise/physiology , Glycogen/metabolism , Muscle, Skeletal/physiology , Cross-Over Studies
19.
J Appl Physiol (1985) ; 134(3): 777-785, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36759160

ABSTRACT

Postactivation potentiation refers to an acute enhancement of contractile properties following muscle activity. Previously, the effects of prior muscle activation on eccentric force at tetanic activation frequencies have only been sparsely reported. This paper aimed to study acute activity-induced effects on eccentric force of slow and fast-twitch muscles and characterize them in relation to postactivation potentiation. We elicited eccentric contractions in isolated rat extensor digitorum longus and soleus muscles by actively lengthening muscles at a constant velocity. We assessed contractile properties by measuring force over shortly interspaced, identical eccentric, and isometric contractions. We then analyzed stretch force, isometric peak force, rate of force development, and relaxation times. Finally, we compared the time courses for the development and cessation of changes in stretch force to known features of postactivation potentiation. In extensor digitorum longus, muscles stretch force consistently increased in a contraction-to-contraction manner by up to 49% [95% confidence interval (CI): 35-64%] whereas isometric peak force simultaneously showed minor declines (8%, 95% CI: 5-10%). The development and cessation of eccentric force potentiation coincided with the development of twitch potentiation and increases in rate of force development. In soleus muscles we found no consistent eccentric potentiation. Characterization of the increase in eccentric force revealed that force only increased in the very beginning of an active stretch. Eccentric force at tetanic activation frequencies potentiates substantially in extensor digitorum longus muscles over consecutive contractions with a time course coinciding with postactivation potentiation. Such eccentric potentiation may be important in sport performance.NEW & NOTEWORTHY Force during eccentric contractions can increase to a magnitude that may have profound consequences for our understanding of skeletal muscle locomotion. This increase in eccentric force occurs over consecutive, shortly interspaced, tetanic contractions in rat extensor digitorum longus muscles-not in rat soleus muscles-and coincides with well-known traits of postactivation potentiation. Eccentric force potentiation may significantly enhance muscle performance in activities involving stretch-shortening cycles.


Subject(s)
Muscle Contraction , Muscle, Skeletal , Animals , Rats , Isometric Contraction/physiology , Muscle Contraction/physiology , Muscle, Skeletal/physiology , Rats, Wistar
20.
J Neural Eng ; 20(1)2023 02 01.
Article in English | MEDLINE | ID: mdl-36638531

ABSTRACT

Objective. Laser stimulators have been widely used in pain studies to selectively activate Aδand C nociceptors without coactivation of mechanoreceptors. Temperature-controlled laser systems have been implemented with low-temperature variations during stimulations, however, these systems purely enabled stationary stimulation. This study aimed to implement, test and validate a new laser stimulation system that controls skin temperature by continuously adjusting laser output during stimulus movement to allow accurate investigation of tempo-spatial mechanisms in the nociceptive system.Approach. For validation, laser stimuli were delivered to the right forearm of eight healthy subjects using a diode laser. The laser beam was displaced across the skin to deliver a moving thermal stimulation to the skin surface. To test the function and feasibility of the system, different stimulation parameters were investigated involving two control modes (open-loop and closed-loop), three displacement velocities (5, 10 and 12 mm s-1), two intensities (high 46 °C and low 42 °C), two stimulus lengths (20 and 100 mm) and two directions (distal and proximal).Main results. During closed-loop control, the stimulation error and variation of stimulation temperatures were significantly smaller than during open-loop control. The standard deviation of stimulation temperatures increased significantly with stimulation intensity and displacement length.Significance. This study showed that more accurate, less variable laser stimulations were delivered to the skin using closed-loop control during a movable stimulus. The more uniform skin temperature during stimuli is likely to ensure a more uniform nociceptor activation.


Subject(s)
Hot Temperature , Lasers, Semiconductor , Pain , Skin , Humans , Lasers , Physical Stimulation , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL