Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 66
Filter
2.
Article in English | MEDLINE | ID: mdl-38289561

ABSTRACT

Ebstein's anomaly of the tricuspid valve (EA) is an uncommon congenital cardiac malformation. It can present with atrioventricular tachycardia (AVRT), atrioventricular nodal re-entrant tachycardia (AVNRT), atrial arrhythmias, and rarely with ventricular tachycardia. The 12-lead electrocardiogram (ECG) is critically important and often diagnostic even prior to an electrophysiology study (EPS). Due to its complex anatomy, it poses particular challenges for mapping and ablation, even for an experienced electrophysiologist. In this review, we aim to provide insight into the electrophysiological perspective of EA and an in-depth analysis of the various arrhythmias encountered in diverse clinical scenarios.

3.
JACC Clin Electrophysiol ; 10(2): 206-218, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38099880

ABSTRACT

BACKGROUND: Accurate annotation of electrogram local activation time (LAT) is critical to the functional assessment of ventricular tachycardia (VT) substrate. Contemporary methods of annotation include: 1) earliest bipolar electrogram (LATearliest); 2) peak bipolar electrogram (LATpeak); 3) latest bipolar electrogram (LATlatest); and 4) steepest unipolar -dV/dt (LAT-dV/dt). However, no direct comparison of these methods has been performed in a large dataset, and it is unclear which provides the optimal functional analysis of the VT substrate. OBJECTIVES: This study sought to investigate the optimal method of LAT annotation during VT substrate mapping. METHODS: Patients with high-density VT substrate maps and a defined critical site for VT re-entry were included. All electrograms were annotated using 5 different methods: LATearliest, LATpeak, LATlatest, LAT-dV/dt, and the novel steepest unipolar -dV/dt using a dynamic window of interest (LATDWOI). Electrograms were also tagged as either late potentials and/or fractionated signals. Maps, utilizing each annotation method, were then compared in their ability to identify critical sites using deceleration zones. RESULTS: Fifty cases were identified with 1,.813 ± 811 points per map. Using LATlatest, a deceleration zone was present at the critical site in 100% of cases. There was no significant difference with LATearliest (100%) or LATpeak (100%). However, this number decreased to 54% using LAT-dV/dt and 76% for LATDWOI. Using LAT-dV/dt, only 33% of late potentials were correctly annotated, with the larger far field signals often annotated preferentially. CONCLUSIONS: Annotation with LAT-dV/dt and LATDWOI are suboptimal in VT substrate mapping. We propose that LATlatest should be the gold standard annotation method, as this allows identification of critical sites and is most suited to automation.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Catheter Ablation/methods , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac , Electrocardiography/methods
4.
JAMA ; 330(10): 925-933, 2023 09 12.
Article in English | MEDLINE | ID: mdl-37698564

ABSTRACT

Importance: The impact of atrial fibrillation (AF) catheter ablation on mental health outcomes is not well understood. Objective: To determine whether AF catheter ablation is associated with greater improvements in markers of psychological distress compared with medical therapy alone. Design, Setting, and Participants: The Randomized Evaluation of the Impact of Catheter Ablation on Psychological Distress in Atrial Fibrillation (REMEDIAL) study was a randomized trial of symptomatic participants conducted in 2 AF centers in Australia between June 2018 and March 2021. Interventions: Participants were randomized to receive AF catheter ablation (n = 52) or medical therapy (n = 48). Main Outcomes and Measures: The primary outcome was Hospital Anxiety and Depression Scale (HADS) score at 12 months. Secondary outcomes included follow-up assessments of prevalence of severe psychological distress (HADS score >15), anxiety HADS score, depression HADS score, and Beck Depression Inventory-II (BDI-II) score. Arrhythmia recurrence and AF burden data were also analyzed. Results: A total of 100 participants were randomized (mean age, 59 [12] years; 31 [32%] women; 54% with paroxysmal AF). Successful pulmonary vein isolation was achieved in all participants in the ablation group. The combined HADS score was lower in the ablation group vs the medical group at 6 months (8.2 [5.4] vs 11.9 [7.2]; P = .006) and at 12 months (7.6 [5.3] vs 11.8 [8.6]; between-group difference, -4.17 [95% CI, -7.04 to -1.31]; P = .005). Similarly, the prevalence of severe psychological distress was lower in the ablation group vs the medical therapy group at 6 months (14.2% vs 34%; P = .02) and at 12 months (10.2% vs 31.9%; P = .01), as was the anxiety HADS score at 6 months (4.7 [3.2] vs 6.4 [3.9]; P = .02) and 12 months (4.5 [3.3] vs 6.6 [4.8]; P = .02); the depression HADS score at 3 months (3.7 [2.6] vs 5.2 [4.0]; P = .047), 6 months (3.4 [2.7] vs 5.5 [3.9]; P = .004), and 12 months (3.1 [2.6] vs 5.2 [3.9]; P = .004); and the BDI-II score at 6 months (7.2 [6.1] vs 11.5 [9.0]; P = .01) and 12 months (6.6 [7.2] vs 10.9 [8.2]; P = .01). The median (IQR) AF burden in the ablation group was lower than in the medical therapy group (0% [0%-3.22%] vs 15.5% [1.0%-45.9%]; P < .001). Conclusion and Relevance: In this trial of participants with symptomatic AF, improvement in psychological symptoms of anxiety and depression was observed with catheter ablation, but not medical therapy. Trial Registration: ANZCTR Identifier: ACTRN12618000062224.


Subject(s)
Anti-Arrhythmia Agents , Atrial Fibrillation , Catheter Ablation , Psychological Distress , Female , Humans , Male , Middle Aged , Anxiety/etiology , Anxiety/therapy , Anxiety Disorders/etiology , Atrial Fibrillation/complications , Atrial Fibrillation/psychology , Atrial Fibrillation/surgery , Atrial Fibrillation/therapy , Catheter Ablation/adverse effects , Catheter Ablation/methods , Catheter Ablation/psychology , Anti-Arrhythmia Agents/therapeutic use , Aged , Depression/etiology , Depression/therapy
7.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1024-1034, 2023 07.
Article in English | MEDLINE | ID: mdl-37227345

ABSTRACT

BACKGROUND: Early postoperative cognitive dysfunction (POCD) has been reported following atrial fibrillation (AF) ablation. However, whether POCD is persistent long-term is unknown. OBJECTIVES: The purpose of this study was to determine if AF catheter ablation is associated with persistent cognitive dysfunction at 12-month follow-up. METHODS: This is a prospective study of 100 patients with symptomatic AF who failed at least 1 antiarrhythmic drug randomized to either ongoing medical therapy or AF catheter ablation and followed up for 12 months. Changes in cognitive performance were assessed using 6 cognitive tests administered at baseline and during follow-up (3, 6, and 12 months). RESULTS: A total of 96 participants completed the study protocol. Mean age was 59 ± 12 years (32% women, 46% with persistent AF). The prevalence of new cognitive dysfunction in the ablation arm compared with the medical arm was as follows: at 3 months: 14% vs 2%; P = 0.03; at 6 months: 4% vs 2%; P = NS; and at 12 months: 0% vs 2%; P = NS. Ablation time was an independent predictor of POCD (P = 0.03). A significant improvement in cognitive scores was seen in 14% of the ablation arm patients at 12 months compared with no patients in the medical arm (P = 0.007). CONCLUSIONS: POCD was observed following AF ablation. However, this was transient with complete recovery at 12-month follow-up.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cognitive Dysfunction , Humans , Female , Middle Aged , Aged , Male , Atrial Fibrillation/complications , Prospective Studies , Cognition , Cognitive Dysfunction/epidemiology , Cognitive Dysfunction/etiology , Catheter Ablation/adverse effects
8.
Eur Heart J ; 44(27): 2447-2454, 2023 Jul 14.
Article in English | MEDLINE | ID: mdl-37062010

ABSTRACT

BACKGROUND: Catheter ablation is an effective strategy in atrial fibrillation (AF). However, its timing in the course of management remains unclear. The aim of this study was to determine if an early vs. delayed AF ablation strategy is associated with differences in arrhythmia outcomes during 12-month follow-up. METHODS AND RESULTS: One hundred patients with symptomatic AF referred to a tertiary centre for management were randomized in a 1:1 ratio to either an early ablation strategy (within 1 month of recruitment) or a delayed ablation strategy (optimized medical therapy followed by catheter ablation at 12 months post recruitment). The primary endpoint was atrial arrhythmia free survival at 12 months post-ablation. Secondary outcomes included: (i) AF burden, (ii) AF burden by AF phenotype, and (iii) antiarrhythmic drug (AAD) use at 12 months. Overall, 89 patients completed the study protocol (Early vs. Delayed: 48 vs. 41). Mean age was 59 ± 12.9 years (29% women). Pulmonary vein isolation was achieved in 100% of patients. At 12 months, 56.3% of patients in the early ablation group were free from recurrent arrhythmia, compared with 58.6% in the delayed ablation group (HR 1.12, 95% CI 0.59-2.13, P = 0.7). All secondary outcomes showed no significant difference including median AF burden (Early vs. Delayed: 0% [IQR 3.2] vs. 0% [5], P = 0.66), median AF burden amongst paroxysmal AF patients (0% [IQR 1.1] vs. 0% [4.5], P = 0.78), or persistent AF patients (0% [IQR 22.8] vs. 0% [5.6], P = 0.45) or AAD use (33% vs. 37%, P = 0.8). CONCLUSION: Compared with an early ablation strategy, delaying AF ablation by 12 months for AAD management did not result in reduced ablation efficacy.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Female , Male , Humans , Atrial Fibrillation/drug therapy , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Catheter Ablation/methods , Recurrence , Pulmonary Veins/surgery
10.
Indian Pacing Electrophysiol J ; 23(3): 63-76, 2023.
Article in English | MEDLINE | ID: mdl-36958589

ABSTRACT

Ventricular tachycardia (VT) is a life-threatening arrhythmia that may be idiopathic or result from structural heart disease. Cardiac imaging is critical in the diagnostic workup and risk stratification of patients with VT. Data gained from cardiac imaging provides information on likely mechanisms and sites of origin, as well as risk of intervention. Pre-procedural imaging can be used to plan access route(s) and identify patients where post-procedural intensive care may be required. Integration of cardiac imaging into electroanatomical mapping systems during catheter ablation procedures can facilitate the optimal approach, reduce radiation dose, and may improve clinical outcomes. Intraprocedural imaging helps guide catheter position, target substrate, and identify complications early. This review summarises the contemporary imaging modalities used in patients with VT, and their uses both pre-procedurally and intra-procedurally.

12.
JACC Clin Electrophysiol ; 9(7 Pt 1): 907-922, 2023 07.
Article in English | MEDLINE | ID: mdl-36752465

ABSTRACT

BACKGROUND: Understanding underlying mechanism(s) and identifying critical circuit components are fundamental to successful ventricular tachycardia (VT) ablation. Directed graph mapping (DGM) offers a novel technique to identify the mechanism and critical components of a VT circuit. OBJECTIVES: This study sought to evaluate the accuracy of DGM in VT ablation compared with traditional mapping techniques and a commercially available automated conduction velocity mapping (ACVM) tool. METHODS: Patients with structural heart disease who had undergone a VT ablation with entrainment-proven critical isthmus and a high-density electroanatomical activation map were included. Traditional mapping (TM) consisted of a combination of local activation time and entrainment mapping and was considered the gold standard for determining the VT mechanism, circuit, and isthmus location. The same local activation time values were then processed using DGM and a commercially available ACVM (Coherent Mapping, Biosense Webster) tool. The aim of this study was to compare TM vs DGM and ACVM in their ability to identify the VT mechanism, characterize the VT circuit, and locate the critical isthmus. RESULTS: Thirty-five cases were identified. TM classified the VT mechanism as focal in 7 patients and re-entrant in 28 patients. TM classified 11 VTs as single-loop re-entry, 15 as dual-loop re-entry, 1 as complex, and 1 case was indeterminant. The overall agreement between DGM and TM for determining VT mechanism and circuit type was strong (kappa value = 0.79; P < 0.01), as was the agreement between ACVM and TM (kappa value = 0.66; P < 0.01). Both DGM and ACVM identified the putative VT isthmus in 25 (89%) of the re-entrant cases. Focal activation was correctly identified by both techniques in all cases. CONCLUSIONS: DGM is a rapid automated algorithm that has a strong level of agreement with TM for manually re-annotated VT maps.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Heart Diseases/surgery
13.
JAMA ; 329(2): 127-135, 2023 01 10.
Article in English | MEDLINE | ID: mdl-36625809

ABSTRACT

Importance: Pulmonary vein isolation (PVI) alone is less effective in patients with persistent atrial fibrillation (AF) compared with paroxysmal AF. The left atrial posterior wall may contribute to maintenance of persistent AF, and posterior wall isolation (PWI) is a common PVI adjunct. However, PWI has not been subjected to randomized comparison. Objective: To compare PVI with PWI vs PVI alone in patients with persistent AF undergoing first-time catheter ablation. Design, Setting, and Participants: Investigator initiated, multicenter, randomized clinical trial involving 11 centers in 3 countries (Australia, Canada, UK). Symptomatic patients with persistent AF were randomized 1:1 to either PVI with PWI or PVI alone. Patients were enrolled July 2018-March 2021, with 1-year follow-up completed March 2022. Interventions: The PVI with PWI group (n = 170) underwent wide antral pulmonary vein isolation followed by posterior wall isolation involving linear ablation at the roof and floor to achieve electrical isolation. The PVI-alone group (n = 168) underwent wide antral pulmonary vein isolation alone. Main Outcomes and Measures: Primary end point was freedom from any documented atrial arrhythmia of more than 30 seconds without antiarrhythmic medication at 12 months, after a single ablation procedure. The 23 secondary outcomes included freedom from atrial arrhythmia with/without antiarrhythmic medication after multiple procedures, freedom from symptomatic AF with/without antiarrhythmic medication after multiple procedures, AF burden between study groups at 12 months, procedural outcomes, and complications. Results: Among 338 patients randomized (median age, 65.6 [IQR, 13.1] years; 76.9% men), 330 (97.6%) completed the study. After 12 months, 89 patients (52.4%) assigned to PVI with PWI were free from recurrent atrial arrhythmia without antiarrhythmic medication after a single procedure, compared with 90 (53.6%) assigned to PVI alone (between-group difference, -1.2%; hazard ratio [HR], 0.99 [95% CI, 0.73-1.36]; P = .98). Of the secondary end points, 9 showed no significant difference, including freedom from atrial arrhythmia with/without antiarrhythmic medication after multiple procedures (58.2% for PVI with PWI vs 60.1% for PVI alone; HR, 1.10 [95% CI, 0.79-1.55]; P = .57), freedom from symptomatic AF with/without antiarrhythmic medication after multiple procedures (68.2% vs 72%; HR, 1.20 [95% CI, 0.80-1.78]; P = .36) or AF burden (0% [IQR, 0%-2.3%] vs 0% [IQR, 0%-2.8%], P = .47). Mean procedural times (142 [SD, 69] vs 121 [SD, 57] minutes, P < .001) and ablation times (34 [SD, 21] vs 28 [SD, 12] minutes, P < .001) were significantly shorter for PVI alone. There were 6 complications for PVI with PWI and 4 for PVI alone. Conclusions and Relevance: In patients undergoing first-time catheter ablation for persistent AF, the addition of PWI to PVI alone did not significantly improve freedom from atrial arrhythmia at 12 months compared with PVI alone. These findings do not support the empirical inclusion of PWI for ablation of persistent AF. Trial Registration: anzctr.org.au Identifier: ACTRN12616001436460.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Female , Humans , Male , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/etiology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Atria/surgery , Pulmonary Veins/surgery , Recurrence , Treatment Outcome , Middle Aged , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/methods
14.
Europace ; 25(3): 1172-1182, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36609707

ABSTRACT

AIMS: Electroanatomical maps using automated conduction velocity (CV) algorithms are now being calculated using two-dimensional (2D) mapping tools. We studied the accuracy of mapping surface 2D CV, compared to the three-dimensional (3D) vectors, and the influence of mapping resolution in non-scarred animal and human heart models. METHODS AND RESULTS: Two models were used: a healthy porcine Langendorff model with transmural needle electrodes and a computer stimulation model of the ventricles built from an MRI-segmented, excised human heart. Local activation times (LATs) within the 3D volume of the mesh were used to calculate true 3D CVs (direction and velocity) for different pixel resolutions ranging between 500 µm and 4 mm (3D CVs). CV was also calculated for endocardial surface-only LATs (2D CV). In the experimental model, surface (2D) CV was faster on the epicardium (0.509 m/s) compared to the endocardium (0.262 m/s). In stimulation models, 2D CV significantly exceeded 3D CVs across all mapping resolutions and increased as resolution decreased. Three-dimensional and 2D left ventricle CV at 500 µm resolution increased from 429.2 ± 189.3 to 527.7 ± 253.8 mm/s (P < 0.01), respectively, with modest correlation (R = 0.64). Decreasing the resolution to 4 mm significantly increased 2D CV and weakened the correlation (R = 0.46). The majority of CV vectors were not parallel (<30°) to the mapping surface providing a potential mechanistic explanation for erroneous LAT-based CV over-estimation. CONCLUSION: Ventricular CV is overestimated when using 2D LAT-based CV calculation of the mapping surface and significantly compounded by mapping resolution. Three-dimensional electric field-based approaches are needed in mapping true CV on mapping surfaces.


Subject(s)
Heart Conduction System , Heart Ventricles , Humans , Animals , Swine , Endocardium , Pericardium , Magnetic Resonance Imaging
15.
JACC Clin Electrophysiol ; 9(1): 1-16, 2023 01.
Article in English | MEDLINE | ID: mdl-36697187

ABSTRACT

BACKGROUND: Accurate annotation of local activation time is crucial in the functional assessment of ventricular tachycardia (VT) substrate. A major limitation of modern mapping systems is the standard prospective window of interest (sWOI) is limited to 490 to 500 milliseconds, preventing annotation of very late potentials (LPs). A novel retrospective window of interest (rWOI), which allows annotation of all diastolic potentials, was used to assess the functional VT substrate. OBJECTIVES: This study sought to investigate the utility of a novel rWOI, which allows accurate visualization and annotation of all LPs during VT substrate mapping. METHODS: Patients with high-density VT substrate maps and a defined isthmus were included. All electrograms were manually annotated to latest activation using a novel rWOI. Reannotated substrate maps were correlated to critical sites, with areas of late activation examined. Propagation patterns were examined to assess the functional aspects of the VT substrate. RESULTS: Forty-eight cases were identified with 1,820 ± 826 points per map. Using the novel rWOI, 31 maps (65%) demonstrated LPs beyond the sWOI limit. Two distinct patterns of channel activation were seen during substrate mapping: 1) functional block with unidirectional conduction into the channel (76%); and 2) wave front collision within the channel (24%). In addition, a novel marker termed the zone of early and late crowding was studied in the rWOI substrate maps and found to have a higher positive predictive value (85%) than traditional deceleration zones (69%) for detecting critical sites of re-entry. CONCLUSIONS: The standard WOI of contemporary mapping systems is arbitrarily limited and results in important very late potentials being excluded from annotation. Future versions of electroanatomical mapping systems should provide longer WOIs for accurate local activation time annotation.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Heart Ventricles , Retrospective Studies , Prospective Studies , Lipopolysaccharides , Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac/methods , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac
19.
Indian Pacing Electrophysiol J ; 22(6): 273-285, 2022.
Article in English | MEDLINE | ID: mdl-36007824

ABSTRACT

Catheter ablation for ventricular tachycardia (VT) in patients with structural heart disease is now part of standard care. Mapping and ablation of the clinical VT is often limited when the VT is noninducible, nonsustained or not haemodynamically tolerated. Substrate-based ablation strategies have been developed in an aim to treat VT in this setting and, subsequently, have been shown to improve outcomes in VT ablation when compared to focused ablation of mapped VTs. Since the initial description of linear ablation lines targeting ventricular scar, many different approaches to substrate-based VT ablation have been developed. Strategies can broadly be divided into three categories: 1) targeting abnormal electrograms, 2) anatomical targeting of conduction channels between areas of myocardial scar, and 3) targeting areas of slow and/or decremental conduction, identified with "functional" substrate mapping techniques. This review summarises contemporary substrate-based ablation strategies, along with their strengths and weaknesses.

20.
J Cardiovasc Electrophysiol ; 33(9): 2116-2120, 2022 09.
Article in English | MEDLINE | ID: mdl-35842799

ABSTRACT

Double mitral and aortic mechanical valves present an access challenge when planning a ventricular tachycardia (VT) ablation. In this case report, we describe a patient who was considered for stereotactic ablative radiotherapy but was unable to proceed due to unfavorable anatomy making them at high risk of fistula formation. The patient went on to have an endocardial VT ablation via mini-thoracotomy and transapical access without complication. This case highlights the need for careful consideration when planning treatment for patients with double mechanical valves.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Catheter Ablation/adverse effects , Endocardium , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...