1.
J Card Fail ; 25(7): 545-552, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31085224

ABSTRACT

BACKGROUND: Left ventricular assist devices (LVADs) have revolutionized the treatment of advanced heart failure, but proliferation of device therapy has unmasked potential complications. Reports have emerged of outflow graft narrowing due to extrinsic compression. METHODS AND RESULTS: The records of patients with LVADs that had been implanted at our institution were reviewed. Those who had postimplantation computed tomography angiographies sufficient to analyze the outflow graft lumen were identified, and the studies were analyzed to characterize the outflow graft lumen. We identified 241 patients; 110 (46%) had suitable computed tomography angiographies. Of those, 15 (14%) had evidence of outflow graft lumen narrowing, all in HeartMate devices and all within the portion covered by the bend relief. Of the 15, 3 underwent invasive examination, all without intraluminal thrombus but, rather, with biodebris between the bend relief and the outflow graft. Patients with HeartWare devices had a wide range of biodebris accumulation surrounding the outflow graft but no cases of lumen narrowing. On multivariable analysis, 1) time from device implant to scan, 2) nonischemic cardiomyopathy and 3) age at implant were significantly associated with higher risk of graft narrowing. CONCLUSION: Outflow graft narrowing can be seen in a number of patients with HeartMate LVADs within the portion covered by the bend relief. In the limited number of patients who underwent invasive evaluation, the narrowing was found to arise from extrinsic compression rather than intraluminal thrombus. The clinical significance of this requires further investigation.


Subject(s)
Graft Occlusion, Vascular , Heart Failure/surgery , Heart-Assist Devices , Prosthesis Implantation , Reoperation , Computed Tomography Angiography/methods , Computed Tomography Angiography/statistics & numerical data , Equipment Failure Analysis , Female , Graft Occlusion, Vascular/diagnosis , Graft Occlusion, Vascular/epidemiology , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/therapy , Heart-Assist Devices/adverse effects , Heart-Assist Devices/statistics & numerical data , Humans , Incidence , Male , Middle Aged , Outcome and Process Assessment, Health Care , Prosthesis Design , Prosthesis Implantation/adverse effects , Prosthesis Implantation/methods , Reoperation/instrumentation , Reoperation/methods , Reoperation/statistics & numerical data , Stents , United States/epidemiology
2.
Ann Glob Health ; 83(2): 293-299, 2017.
Article in English | MEDLINE | ID: mdl-28619404

ABSTRACT

BACKGROUND: Early detection and treatment of pediatric asthma could reduce morbidity and lessen burden on society. Currently there is no known research on the prevalence of pediatric asthma in the Dominican Republic (DR) and no known asthma risk assessment tool for one-time encounters in a fast-paced clinic. OBJECTIVES: To pilot a streamlined version of previously validated screening tools to estimate the prevalence of pediatric asthma risk in Santo Domingo Norte, DR. METHODS: A combined asthma questionnaire and clinical assessment tool was developed and administered to patients aged 2-12 years. FINDINGS: We found that 25.7% of the 74 study participants were categorized as probable asthma, 21.6% were at high risk for asthma, 14.9% elevated risk, and 37.8% not at risk. CONCLUSION: If the prevalence of 25.7% is representative of the DR as a whole, the DR would have one of the highest national rates in Latin America. The study assessment tool was convenient to use, but tool validation is needed.


Subject(s)
Asthma/epidemiology , Asthma/diagnosis , Child , Child, Preschool , Dominican Republic/epidemiology , Humans , Latin America , Prevalence , Risk , Risk Assessment