Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Sci (Basel) ; 11(3)2023 09 11.
Article in English | MEDLINE | ID: mdl-37755163

ABSTRACT

BACKGROUND: Accurate dosimetry is crucial in radiotherapy to ensure optimal radiation dose delivery to the tumor while sparing healthy tissues. Traditional dosimetry techniques using homogeneous phantoms may not accurately represent the complex anatomical variations in cervical cancer patients, highlighting the need to compare dosimetry results obtained from different phantom models. PURPOSE: The aim of this study is to design and evaluate an anthropomorphic heterogeneous female pelvic (AHFP) phantom for radiotherapy quality assurance in cervical cancer treatment. MATERIALS AND METHOD: Thirty RapidArc plans designed for cervical cancer patients were exported to both the RW3 homogeneous phantom and the anthropomorphic heterogeneous pelvic phantom. Dose calculations were performed using the anisotropic analytic algorithm (AAA), and the plans were delivered using a linear accelerator (LA). Dose measurements were obtained using a 0.6 cc ion chamber. The percentage (%) variation between planned and measured doses was calculated and analyzed. Additionally, relative dosimetry was performed for various target locations using RapidArc and IMRT treatment techniques. The AHFP phantom demonstrated excellent agreement between measured and expected dose distributions, making it a reliable quality assurance tool in radiotherapy. RESULTS: The results reveal that the percentage variation between planned and measured doses for all RapidArc quality assurance (QA) plans using the AHFP phantom is 10.67% (maximum value), 2.31% (minimum value), and 6.89% (average value), with a standard deviation (SD) of 2.565 (t = 3.21604, p = 0.001063). Also, for the percentage of variation between homogeneous and AHFP phantoms, the t-value is -11.17016 and the p-value is <0.00001. The result is thus significant at p < 0.05. We can see that the outcomes differ significantly due to the influence of heterogeneous media. Also, the average gamma values in RapidArc plans are 0.29, 0.32, and 0.35 (g ≤ 1) and IMRT plans are 0.45, 0.44, and 0.42 (g ≤ 1) for targets 1, 2, and 3, respectively. CONCLUSION: The AHFP phantom results show more dose variability than homogenous phantom outcomes. Also, the AHFP phantom was found to be suitable for QA evaluation.


Subject(s)
Radiation Oncology , Uterine Cervical Neoplasms , Humans , Female , Uterine Cervical Neoplasms/radiotherapy , Radiometry , Algorithms , Anisotropy
2.
J Family Med Prim Care ; 11(9): 5692-5695, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36505588

ABSTRACT

Amphotericin B (AMB) has been the irreplaceable drug of choice for countless fungal and protozoal infections. One of the lesser-known adverse effects of AMB is Pancytopenia - very rare with very few cases reported - most commonly observed following prolonged administration. We report the case of a patient suffering from visceral leishmaniasis, who developed worsening pancytopenia four to five days after being administered a single bolus dose of Liposomal Amphotericin B (L-AMB). The diagnosis was clinical and management involved supportive care, and granulocyte-macrophage colony-stimulating factor (GM-CSF). AMB is an effective drug, but is also associated with numerous side effects. Physicians are well-versed with the more frequently seen adverse drug reactions and their management. However, pancytopenia, being a rare adverse reaction to AMB, is less known and can be easily overlooked. This case report aims to ensure that the physicians must be aware of such possibilities in the first place to make swift diagnoses and management. The condition itself is seemingly self-limiting, although GM-CSF may be needed in refractory cases. It's true that few previous case reports have indicated pancytopenia in association with prolonged AMB exposure, but we believe certain conditions may predispose a patient to a more acute presentation - as seen in our case.

SELECTION OF CITATIONS
SEARCH DETAIL
...