Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 13(1): 21531, 2023 12 06.
Article in English | MEDLINE | ID: mdl-38057609

ABSTRACT

Considerable research has been focused on identifying the optimum biomaterial for spine implants. New technologies and materials have allowed surgeons to better grasp the biomechanical principles underpinning implant stability and function. An optimal biomaterial for total disc replacement (TDR) should include essential characteristics such as biocompatibility, long-term durability, the capacity to withstand mechanical stresses, and economic viability. Our research has focused on six biomaterials for TDR, including Ti-6Al-4V, CoCr alloy, stainless steel 316L, zirconia toughened alumina (ZTA), polyether ether ketone (PEEK) and ultra-high-molecular weight polyethylene (UHMWPE). Ten common properties, i.e., the Young's modulus, density, tensile strength, the expense of the manufacturing process, the cost of raw material, wear rate, corrosion resistance, thermal conductivity, fracture toughness and compressive strength were utilized to assess these six different materials. The purpose of this study was to evaluate and rank the six alternative biomaterials proposed for use in the endplates and articulating surface of a spinal TDR. To accomplish this, a multi-criteria decision-making approach, namely the fuzzy analytic hierarchy process (fuzzy AHP) and the Technique of Order Preference by Similarity to Ideal Solution (TOPSIS) was adopted to solve the model. For validation and robustness of the proposed method, sensitivity analysis was performed, and comparison was performed with fuzzy-VIKOR and fuzzy-MOORA methods. In light of the study's results, ZTA and Ti-6Al-4V were identified as the best suited materials for the articulating surface and endplates, respectively, in a spinal disc implant.


Subject(s)
Analytic Hierarchy Process , Biocompatible Materials , Prostheses and Implants , Spine/surgery , Alloys , Decision Making , Titanium , Materials Testing
2.
J Biomech Eng ; 144(10)2022 10 01.
Article in English | MEDLINE | ID: mdl-35482019

ABSTRACT

In vitro testing has been conducted to provide a comprehensive understanding of the biomechanics of the cervical spine. This has allowed a characterization of the stability of the spine as influenced by the intrinsic properties of its tissue constituents and the severity of degeneration or injury. This also enables the preclinical estimation of spinal implant functionality and the success of operative procedures. The purpose of this review paper was to compile methodologies and results from various studies addressing spinal kinematics in pre- and postoperative conditions so that they could be compared. The reviewed literature was evaluated to provide suggestions for a better approach for future studies, to reduce the uncertainties and facilitate comparisons among various results. The overview is presented in a way to inform various disciplines, such as experimental testing, design development, and clinical treatment. The biomechanical characteristics of the cervical spine, mainly the segmental range of motion (ROM), intradiscal pressure (IDP), and facet joint load (FJL), have been assessed by testing functional spinal units (FSUs). The relative effects of pathologies including disc degeneration, muscle dysfunction, and ligamentous transection have been studied by imposing on the specimen complex load scenarios imitating physiological conditions. The biomechanical response is strongly influenced by specimen type, test condition, and the different types of implants utilized in the different experimental groups.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Zygapophyseal Joint , Biomechanical Phenomena , Cervical Vertebrae , Humans , Intervertebral Disc/physiology , Range of Motion, Articular/physiology , Zygapophyseal Joint/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...