Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Vestn Oftalmol ; 140(2): 40-46, 2024.
Article in Russian | MEDLINE | ID: mdl-38742497

ABSTRACT

Extended depth of focus (EDOF) intraocular lenses (IOLs) are the latest IOL designs. In recent years, several models of EDOF IOLs have become available in Russia, two of which (Tecnis Symfony and Acrysof IQ Vivity) are implanted in our clinic. Comparative studies devoted to the results of implantation of the new EDOF IOLs are rare in the available literature. PURPOSE: This article compares the outcomes of implantation of two EDOF IOLs in patients with presbyopia and/or cataract. MATERIAL AND METHODS: The prospective study included 60 patients (81 eyes) after implantation of EDOF IOL Tecnis Symfony (32 patients, 45 eyes; group 1) or EDOF IOL AcrySof IQ Vivity (28 patients, 36 eyes; group 2). The mean follow-up period was 3.9±1.3 months. RESULTS: All groups showed a significant (p<0.05) increase in uncorrected near visual acuity (UCNVA), intermediate visual acuity (UCIVA), and distance visual acuity (UCDVA) at the maximum follow-up time compared to preoperative values. In group 1, the best corrected near visual acuity (BCNVA) increased from 0.61±0.10 to 0.82±0.16 at the maximum follow-up time, and in group 2 - from 0.58±0.08 to 0.67±0.12 (p>0.05). Both groups showed a significant increase in best corrected intermediate and distance visual acuity (BCIVA and BCDVA) at the maximum follow-up time. The increase in the indicator compared to the preoperative period was not significant in both groups (p>0.05). The frequency of side optical phenomena was low in both groups. No significant differences were found between the groups (p>0.05). CONCLUSION: This study presents a comparative analysis of the results of implantation of two different EDOF IOLs. Both lenses were comparable in most of the studied parameters, including providing good distance and intermediate vision, functional near vision, as well as a low frequency of side optical phenomena. In all cases the patients were satisfied with the results of the surgical intervention.


Subject(s)
Lens Implantation, Intraocular , Lenses, Intraocular , Presbyopia , Visual Acuity , Humans , Male , Female , Lens Implantation, Intraocular/methods , Middle Aged , Presbyopia/surgery , Presbyopia/physiopathology , Prosthesis Design , Prospective Studies , Aged , Treatment Outcome , Cataract/physiopathology , Cataract/diagnosis , Refraction, Ocular/physiology , Depth Perception/physiology , Russia
2.
Vestn Oftalmol ; 138(5): 30-38, 2022.
Article in Russian | MEDLINE | ID: mdl-36288415

ABSTRACT

In recent years, a new class of extended depth of focus (EDOF) intraocular lenses (IOLs) has become available on the market. There is only a limited number of scientific papers comparing trifocal and EDOF IOL data, and the results are often contradictory. PURPOSE: Comparative analysis of the results of trifocal and EDOF IOL implantation in patients with presbyopia and/or cataract. MATERIAL AND METHODS: This prospective study included 72 patients (144 eyes) after bilateral implantation of either Tecnis Symfony EDOF IOL (18 patients, 36 eyes; group I) or AcrySof PanOptix trifocal IOL (54 patients, 108 eyes; group II). In 18 patients out of 72 (25%) the implantation involved mini-monovision, i.e. the calculation of the IOL power on the nondominant eye was performed at -0.5 D. The average follow-up period for the patients was 7.1±1.2 months. RESULTS: There was a significant (p<0.05) increase in uncorrected near visual acuity (UCNVA), uncorrected intermediate visual acuity (UCIVA) and uncorrected distance visual acuity (UCDVA) at the maximum follow-up time compared to the preoperative indices in all groups. Group II was characterized by slightly better UCNVA dynamics (0.85±0.13 versus 0.2±0.04 before surgery, as comparted to 0.78±0.11 versus 0.19±0.06 before surgery in group I), but differences were not statistically significant (p>0.05). Statistically significant differences (p=0.046) were observed when comparing best corrected near vision acuity (BCNVA) in groups I and II (0.79±0.05 and 0.98±0.08, respectively) at 6 months compared to the preoperative period (0.62±0.09 and 0.6±0.11, respectively). CONCLUSION: Trifocal IOL implantation was associated with acceptable near and far vision correction and a higher frequency of adverse optical phenomena, while implantation of the EDOF IOL was associated with slightly better correction of intermediate vision and a significantly lower incidence of halo and glare. Patients were satisfied with the outcomes of surgery in all cases.


Subject(s)
Lenses, Intraocular , Phacoemulsification , Humans , Lens Implantation, Intraocular/adverse effects , Lens Implantation, Intraocular/methods , Refraction, Ocular , Prospective Studies , Visual Acuity , Phacoemulsification/adverse effects , Prosthesis Design , Patient Satisfaction , Pseudophakia
3.
Bull Exp Biol Med ; 160(4): 535-41, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26899843

ABSTRACT

3D biodegradable materials (scaffolds) containing bioactive hydroxyapatite molecules fabricated by foaming in supercritical carbon dioxide and by selective laser sintering were used for culturing of mesenchymal stromal cells from the human adipose tissue. Experiments showed that stromal cells from the human adipose tissue adhered and proliferated on all studied types of structures. Addition of hyproxyapatite to the scaffold stimulated proliferation of stromal adipose tissue cells.


Subject(s)
Adipose Tissue/cytology , Biocompatible Materials , Cell Culture Techniques , Durapatite/pharmacology , Mesenchymal Stem Cells/cytology , Tissue Scaffolds , Cell Adhesion , Cell Differentiation , Cell Proliferation , Cell Survival , Cells, Cultured , Humans , Tissue Engineering
SELECTION OF CITATIONS
SEARCH DETAIL
...