Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
J Thromb Haemost ; 15(8): 1620-1624, 2017 08.
Article in English | MEDLINE | ID: mdl-28586149

ABSTRACT

Essentials Bleeding is a major source of morbidity during mechanical circulatory support. von Willebrand factor (VWF) multimer loss may contribute to bleeding. Different patterns of VWF multimer loss were seen with the two device types. This is the first report of total artificial heart associated VWF multimer loss. SUMMARY: Background Bleeding remains a challenge during mechanical circulatory support and underlying mechanisms are incompletely understood. Functional von Willebrand factor (VWF) impairment because of loss of high-molecular-weight multimers (MWMs) produces acquired von Willebrand disease (VWD) after left ventricular assist device (LVAD). Little is known about VWF multimers with total artificial hearts (TAHs). Here, VWF profiles with LVADs and TAHs are compared using a VWD panel. Methods VWD evaluations for patients with LVAD or TAH (2013-14) were retrospectively analyzed and included: VWF activity (ristocetin cofactor, VWF:RCo), VWF antigen (VWF:Ag), ratio of VWF:RCo to VWF:Ag, and quantitative VWF multimeric analysis. Results Twelve patients with LVADs and 12 with TAHs underwent VWD evaluation. All had either normal (47.8%) or elevated (52.2%) VWF:RCo, normal (26.1%) or elevated (73.9%) VWF:Ag and 50.0% were disproportional (ratio ≤ 0.7). Multimeric analysis showed abnormal patterns in all patients with LVADs: seven with high MWM loss; five with highest MWM loss. With TAH, 10/12 patients had abnormal patterns: all with highest MWM loss. High MWM loss correlated with presence of LVAD and highest MWM loss with TAH. Increased low MWMs were detected in 22/24. Conclusion Using VWF multimeric analysis, abnormalities after LVAD or TAH were detected that would be missed with measurements of VWF level alone: loss of high MWM predominantly in LVAD, loss of highest MWM in TAH, and elevated levels of low MWM in both. This is the first study to describe TAH-associated highest MWM loss, which may contribute to bleeding.


Subject(s)
Heart Failure/therapy , Heart, Artificial/adverse effects , Heart-Assist Devices/adverse effects , Hemorrhage/etiology , Ventricular Function, Left , von Willebrand Factor/metabolism , Adult , Biomarkers/blood , Down-Regulation , Female , Heart Failure/blood , Heart Failure/diagnosis , Heart Failure/physiopathology , Hemorrhage/blood , Hemorrhage/diagnosis , Humans , Male , Middle Aged , Prosthesis Design , Protein Multimerization , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
2.
Transplant Proc ; 49(2): 253-259, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28219580

ABSTRACT

The most common causes of death after heart transplantation (HTx) include acute rejection and multi-organ failure in the early period and malignancy and cardiac allograft vasculopathy (CAV) in the late period. Polyclonal antibody preparations such as rabbit anti-thymocyte globulin (ATG) may reduce early acute rejection and the later occurrence of CAV after HTx. ATG therapy depletes T cells, modulates adhesion and cell-signaling molecules, interferes with dendritic cell function, and induces B-cell apoptosis and regulatory and natural killer T-cell expansion. Evidence from animal studies and from retrospective clinical studies in humans indicates that ATG can be used to delay calcineurin inhibitor (CNI) exposure after HTx, thus benefiting renal function, and to reduce the incidence of CAV and ischemia-reperfusion injury in the transplanted heart. ATG may reduce de novo antibody production after HTx. ATG does not appear to increase cytomegalovirus infection rates with longer prophylaxis (6-12 months). In addition, ATG may reduce the risk of lymphoproliferative disease and does not appear to confer an additive effect on acquiring lymphoma after HTx. Randomized, controlled trials may provide stronger evidence of ATG association with patient survival, graft rejection, renal protection through delayed CNI initiation, as well as other benefits. It can also help establish optimal dosing and patient criteria to maximize treatment benefits.


Subject(s)
Antilymphocyte Serum/therapeutic use , Heart Transplantation/methods , Immunosuppressive Agents/therapeutic use , Antibody Formation , B-Lymphocytes/immunology , Calcineurin Inhibitors/therapeutic use , Cytomegalovirus Infections/drug therapy , Graft Rejection/immunology , Heart Diseases/immunology , Heart Diseases/surgery , Humans , Induction Chemotherapy/methods , Natural Killer T-Cells/immunology , Reperfusion Injury/drug therapy , Retrospective Studies
3.
Transplant Proc ; 49(2): 348-353, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28219597

ABSTRACT

BACKGROUND: We report clinical experience with combined heart and kidney transplantation (HKTx) over a 23-year time period. METHODS: From June 1992 to August 2015, we performed 83 combined HKTx procedures at our institution. We compared the more recent cohort of 53 HKTx recipients (group 2, March 2009 to August 2015) with the initial 30 previously reported HKTx recipients (group 1, June 1992 to February 2009). Pre-operative patient characteristics, peri-operative factors, and post-operative outcomes including survival were examined. RESULTS: The baseline characteristics of the two groups were similar, except for a lower incidence of ethanol use and higher pre-operative left-ventricular ejection fraction, cardiac output, and cardiac index in group 2 when compared with group 1 (P = .007, .046, .037, respectively). The pump time was longer in group 2 compared with group 1 (153.30 ± 38.68 vs 129.60 ± 37.60 minutes; P = .007), whereas the graft ischemic time was not significantly different between the groups, with a trend to a longer graft ischemic time in group 2 versus group 1 (195.17 ± 45.06 vs 178.07 ± 52.77 minutes; P = .056, respectively). The lengths of intensive care unit (ICU) and hospital stay were similar between the groups (P = .083 and .39, respectively). In addition, pre-operative and post-operative creatinine levels at peak, discharge, 1 year, and 5 years and the number of people on post-operative dialysis were similar between the groups (P = .37, .75, .54, .87, .56, and P = .139, respectively). Overall survival was not significantly different between groups 2 and 1 for the first 5 years after transplant, with a trend toward higher survival in group 2 (P = .054). CONCLUSIONS: The most recent cohort of combined heart and kidney transplant recipients had similar ICU and hospital lengths of stay and post-operative creatinine levels at peak, discharge, and 1 and 5 years and a similar number of patients on post-operative dialysis when compared with the initial cohort. Overall survival was not significantly different between the later and earlier groups, with a trend toward higher overall survival at 5 years in the more recent cohort of patients. In selected patients with co-existing heart and kidney failure, combined heart and kidney transplantation is safe to perform and has excellent outcomes.


Subject(s)
Heart Transplantation/methods , Kidney Transplantation/methods , Female , Heart Failure/mortality , Heart Failure/surgery , Heart Transplantation/mortality , Humans , Kaplan-Meier Estimate , Kidney Transplantation/mortality , Length of Stay/statistics & numerical data , Male , Middle Aged , Patient Selection , Postoperative Care , Renal Insufficiency/mortality , Renal Insufficiency/surgery , Retrospective Studies , Treatment Outcome
4.
Transplant Proc ; 48(10): 3393-3396, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27931587

ABSTRACT

BACKGROUND: The use of mechanical circulatory support devices (MCSDs) has been increasing over the past several years. Driveline infections (DLIs) are one of the most common complications seen in these patients; reportedly, up to 50% of patients with MCSDs can develop this complication. It is believed that the removal of the driveline results in treatment of the localized infection area. MCSD patients are also known to develop circulating antibodies. These circulating antibodies have been associated with poor outcomes after heart transplantation. The use of rabbit antithymocyte globulin (ATG) as induction therapy reportedly decreases the development of circulating antibodies; it is now commonly used in sensitized patients undergoing heart transplantation. It is unknown whether ATG induction therapy immediate posttransplant will increase the risk of infection of those MCSD patients with DLIs. METHODS: Between 2003 and 2013, we evaluated 57 MCSD patients who subsequently underwent heart transplantation and received ATG induction therapy. Patients were divided into those with previous MCSD DLI and those without, and they were assessed for 1-year freedom from infection (specifically, sternal wound infections). One-year survival and freedom from treated rejection, both cellular and antibody mediated, were also assessed. RESULTS: MCSD patients with DLIs who received ATG induction did not have a lower freedom from any treated infection and from sternal wound infection posttransplant compared with those MCSD patients without DLIs and not treated with ATG induction. There were also no significant differences between the 2 groups in terms of 1-year posttransplant survival and freedom from treated rejection. CONCLUSIONS: The use of ATG induction in patients with prior DLIs did not seem to increase the risk for posttransplant infection (eg, sternal wound infection). ATG induction can therefore be safely used in this population.


Subject(s)
Antilymphocyte Serum/administration & dosage , Heart Transplantation/adverse effects , Heart-Assist Devices/adverse effects , Immunosuppressive Agents/administration & dosage , Prosthesis-Related Infections/complications , Surgical Wound Infection/etiology , Adult , Animals , Antibodies/blood , Female , Humans , Male , Middle Aged , Rabbits , Risk Factors
5.
Transplant Proc ; 48(8): 2782-2791, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27788818

ABSTRACT

BACKGROUND: The upper age limit of heart transplantation remains controversial. The goal of the present study was to investigate the mortality and morbidity of orthotopic heart transplantation (HT) for recipients ≥70 compared with those <70 years of age. METHODS: Of 704 adults who underwent HT from December 1988 to June 2012 at our institution, 45 were ≥70 years old (older group) and 659 were <70 years old (younger group). Survival, intraoperative blood product usage, intensive care unit (ICU) and hospital stays, and frequency of reoperation for chest bleeding, dialysis, and >48 hours ventilation were examined after HT. RESULTS: The older group had 100% 30-day and 60-day survival compared with 96.8 ± 0.7% 30-day and 95.9 ± 0.8% 60-day survival rates in the younger group. The older and younger groups had similar 1-year (93.0 ± 3.9% vs 92.1 ± 1.1%; P = .79), 5-year (84.2 ± 6.0% vs 73.4 ± 1.9%; P = .18), and 10-year (51.2 ± 10.7% vs 50.2 ± 2.5%; P = .43) survival rates. Recipients in the older group had higher preoperative creatinine levels, frequency of coronary artery disease, and more United Network for Organ Sharing status 2 and fewer status 1 designations than recipients in the younger group (P < .05 for all). Pump time and intraoperative blood usage were similar between the 2 groups (P = NS); however, donor-heart ischemia time was higher in the older group (P = .002). Older recipients had higher postoperative creatinine levels at peak (P = .003) and at discharge (P = .007). Frequency of postoperative complications, including reoperation for chest bleeding, dialysis, >48 hours ventilation, pneumonia, pneumothorax, sepsis, in-hospital and post-discharge infections, were similar between groups (P = NS for all comparisons). ICU and hospital length of stays were similar between groups (P = .35 and P = .87, respectively). In Cox analysis, recipient age ≥70 years was not identified as a predictor of lower long-term survival after HT. CONCLUSIONS: HT recipients ≥70 years old had similar 1, 5, and 10-year survival rates compared with younger recipients. Both patient groups had similar intra- and postoperative blood utilization and frequencies of many postoperative complications. Older and younger patients had similar morbidity and mortality rates following HT. Carefully selected older patients (≥70 years) can safely undergo HT and should not be excluded from HT consideration based solely on age.


Subject(s)
Heart Transplantation/mortality , Age Distribution , Age Factors , Aged , Coronary Artery Disease/mortality , Critical Care/statistics & numerical data , Female , Heart Transplantation/methods , Humans , Length of Stay/statistics & numerical data , Male , Middle Aged , Postoperative Complications/mortality , Renal Dialysis/mortality , Reoperation/mortality , Survival Rate , Tissue Donors/statistics & numerical data , Treatment Outcome
6.
Transplant Proc ; 48(1): 158-66, 2016.
Article in English | MEDLINE | ID: mdl-26915862

ABSTRACT

PURPOSE: The impact of prior implantation of a ventricular assist device (VAD) on short- and long-term postoperative outcomes of adult heart transplantation (HTx) was investigated. METHODS: Of the 359 adults with prior cardiac surgery who underwent HTx from December 1988 to June 2012 at our institution, 90 had prior VAD and 269 had other (non-VAD) prior cardiac surgery. RESULTS: The VAD group had a lower 60-day survival when compared with the Non-VAD group (91.1% ± 3.0% vs 96.6% ± 1.1%; P = .03). However, the VAD and Non-VAD groups had similar survivals at 1 year (87.4% ± 3.6% vs 90.5% ± 1.8%; P = .33), 2 years (83.2% ± 4.2% vs 88.1% ± 2.0%; P = .21), 5 years (75.7% ± 5.6% vs 74.6% ± 2.9%; P = .63), 10 years (38.5% ± 10.8% vs 47.6% ± 3.9%; P = .33), and 12 years (28.9% ± 11.6% vs 39.0% ± 4.0%; P = .36). The VAD group had longer pump time and more intraoperative blood use when compared with the Non-VAD group (P < .0001 for both). Postoperatively, VAD patients had higher frequencies of >48-hour ventilation and in-hospital infections (P = .0007 and .002, respectively). In addition, more VAD patients had sternal wound infections when compared with Non-VAD patients (8/90 [8.9%] vs 5/269 [1.9%]; P = .005). Both groups had similar lengths of intensive care unit (ICU) and hospital stays and no differences in the frequencies of reoperation for chest bleeding, dialysis, and postdischarge infections (P = .19, .70, .34, .67, and .21, respectively). Postoperative creatinine levels at peak and at discharge did not differ between the 2 groups (P = .51 and P = .098, respectively). In a Cox model, only preoperative creatinine ≥1.5 mg/dL (P = .006) and intraoperative pump time ≥210 minutes (P = .022) were individually considered as significant predictors of mortality within 12 years post-HTx. Adjusting for both, pre-HTx VAD implantation was not a predictor of mortality within 12 years post-HTx (hazard ratio [HR], 1.23; 95% confidence interval [CI], 0.77-1.97; P = .38). However, pre-HTx VAD implantation was a risk factor for 60-day mortality (HR, 2.86; 95% CI, 1.07-7.62; P = .036) along with preoperative creatinine level ≥2 mg/dL (P = .0006). CONCLUSIONS: HTx patients with prior VAD had lower 60-day survival, higher intraoperative blood use, and greater frequency of postoperative in-hospital infections when compared with HTx patients with prior Non-VAD cardiac surgery. VAD implantation prior to HTx did not have an additional negative impact on long-term morbidity and survival following HTx. Long-term (1-, 2-, 5-, 10-, and 12-year) survival did not differ significantly in HTx patients with prior VAD or non-VAD cardiac surgery.


Subject(s)
Heart Failure/therapy , Heart Transplantation/mortality , Heart-Assist Devices , Adult , California/epidemiology , Female , Heart Failure/mortality , Humans , Length of Stay/trends , Male , Middle Aged , Proportional Hazards Models , Risk Factors , Survival Rate/trends , Time Factors , Treatment Outcome
7.
Transplant Proc ; 48(1): 279-81, 2016.
Article in English | MEDLINE | ID: mdl-26915885

ABSTRACT

Chagas disease (CD) is becoming an increasingly recognized cause of dilated cardiomyopathy outside of Latin America, where it is endemic, due to population shifts and migration. Heart transplantation (HTx) is a therapeutic option for end-stage cardiomyopathy due to CD, but may be considered a relative contraindication due to potential reactivation of the causative organism with immunosuppression therapy. The total artificial heart (TAH) can provide mechanical circulatory support in decompensated patients with severe biventricular dysfunction until the time of HTx, while avoiding immunosuppressive therapy and removing the organ most affected by the causative organism. We report herein a patient with CD and severe biventricular dysfunction, who had mechanical circulatory support with a TAH for more than 6 months, followed by successful orthotopic HTx and treatment with benznidazole for 3 months. The patient had no evidence of recurrent disease in the transplanted heart based on endomyocardial biopsy up to 1 year post-transplantation, and remains alive more than 30 months after insertion of a TAH and 24 months after HTx.


Subject(s)
Chagas Cardiomyopathy/surgery , Heart Transplantation/methods , Heart, Artificial , Chagas Cardiomyopathy/complications , Female , Humans , Middle Aged , Nitroimidazoles/therapeutic use , Treatment Outcome , Trypanocidal Agents/therapeutic use , Ventricular Dysfunction/parasitology , Ventricular Dysfunction/surgery
8.
Transplant Proc ; 47(7): 2291-4, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26361702

ABSTRACT

Malignancy is the leading cause of long-term morbidity and mortality after heart and other solid organ transplantation; therefore, great emphasis is placed on pre- and post-transplantation cancer screening. Even with meticulous screening during evaluation for heart transplant candidacy, an occult cancer may not be apparent. Here, we share the case of a 51-year-old man with refractory heart failure who underwent total artificial heart implantation as a bridge to transplantation with the surprise finding of an isolated deposit of metastatic carcinoid tumor nested within a left ventricular papillary muscle in his explanted heart. The primary ileal carcinoid tumor was identified and resected completely. After remaining cancer-free for 14 months, he was listed for heart transplantation and was transplanted 2 months later. He is currently 3.5 months out from heart transplantation and doing well, without evidence of recurring malignancy.


Subject(s)
Carcinoma, Neuroendocrine/surgery , Heart Failure/surgery , Heart Neoplasms/surgery , Heart Transplantation , Heart-Assist Devices , Carcinoma, Neuroendocrine/complications , Carcinoma, Neuroendocrine/diagnosis , Heart Failure/etiology , Heart Neoplasms/complications , Heart Neoplasms/diagnosis , Heart Ventricles , Humans , Male , Middle Aged
9.
Transplant Proc ; 47(2): 485-97, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25769596

ABSTRACT

BACKGROUND: This study investigated the effect of prior sternotomy (PS) on the postoperative mortality and morbidity after orthotopic heart transplantation (HTx). METHODS: Of 704 adults who underwent HTx from December 1988 to June 2012 at a single institution, 345 had no PS (NPS group) and 359 had ≥ 1 PS (PS group). Survival, intraoperative use of blood products, intensive care unit (ICU) and hospital stays, frequency of reoperation for bleeding, dialysis, and >48-hour ventilation were examined. RESULTS: The NPS and PS groups had similar 60-day survival rates (97.1 ± 0.9% vs 95.3 ± 1.1%; P = .20). However, the 1-year survival was higher in the NPS group (94.7 ± 1.2% vs 89.7 ± 1.6%; hazard ratio [HR], 1.98; 95% CI, 1.12-3.49; P = .016). The PS group had longer pump time and more intraoperative blood use (P < .0001 for both). Postoperatively, the PS group had longer ICU and hospital stays, and higher frequencies of reoperation for bleeding and >48-hour ventilation (P < .05 for all comparisons). Patients with 1 PS (1PS group) had a higher 60-day survival rate than those with ≥ 2 PS (2+PS group; 96.7 ± 1.1% vs 91.1 ± 3.0%; HR, 2.70; 95% CI, 1.04-7.01; P = .033). The 2+PS group had longer pump time and higher frequency of postoperative dialysis (P < .05 for both). Patients with prior VAD had lower 60-day (91.1 ± 3.0% vs 97.1 ± 0.9%; P = .010) and 1-year (87.4 ± 3.6% vs 94.7 ± 1.2%; P = .012) survival rates than NPS group patients. Patients with prior CABG had a lower 1-year survival than NPS group patients (89.0 ± 2.3% vs 94.7 ± 1.2%; P = .018). CONCLUSION: The PS group had lower 1-year survival and higher intraoperative blood use, postoperative length of ICU and hospital stays, and frequency of reoperation for bleeding than the NPS group. Prior sternotomy increases morbidity and mortality after HTx.


Subject(s)
Heart Failure/mortality , Heart Transplantation/mortality , Sternotomy/adverse effects , Adult , Aged , Critical Care , Female , Heart Failure/surgery , Heart Transplantation/adverse effects , Heart-Assist Devices , Humans , Length of Stay , Male , Middle Aged , Reoperation/adverse effects , Reoperation/mortality , Retrospective Studies , Survival Rate , Time Factors , Treatment Outcome
10.
Transplant Proc ; 47(1): 210-2, 2015.
Article in English | MEDLINE | ID: mdl-25596961

ABSTRACT

We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure.


Subject(s)
Heart Failure/surgery , Heart Transplantation , Heart, Artificial , Kidney Failure, Chronic/surgery , Kidney Transplantation , Female , Heart Failure/complications , Heart Failure/diagnosis , Humans , Kidney Failure, Chronic/diagnosis , Kidney Failure, Chronic/etiology , Male , Middle Aged , Pulsatile Flow
11.
Transplant Proc ; 46(1): 249-55, 2014.
Article in English | MEDLINE | ID: mdl-24507061

ABSTRACT

INTRODUCTION: Patients with history of prior sternotomy may have poorer outcomes after heart transplantation. Quantitation of risk from prior sternotomy has not been well established. The United Network for Organ Sharing (UNOS) database was analyzed to assess early and late survival and predictors of outcome in adult heart transplant recipients with and without prior sternotomy. METHODS: Of 11,266 adults with first heart-only transplantation from 1997 to 2011, recipients were divided into 2 groups: those without prior sternotomy (first sternotomy group; n = 6006 or 53.3%) and those with at least 1 prior sternotomy (redo sternotomy group; n = 5260 or 46.7%). A multivariable Cox model was used to identify predictors of mortality. RESULTS: Survival was lower in the redo group at 60 days (92.6% vs 95.9%; hazard ratio [HR] 1.83, 95% confidence interval [CI]: 1.56-2.15; P < .001). Conditional 5-year survival in 60-day survivors was similar in the 2 groups (HR = 1.01, 95% CI 0.90-1.12, P = .90). During the first 60 days post-transplant, the redo group had more cardiac reoperations (12.3% vs 8.8%, P = .0008), a higher frequency of dialysis (8.9% vs 5.2%, P < .0001), a greater percentage of drug-treated infections (23.2% vs 19%, P = .003), and a higher percentage of strokes (2.5% vs 1.4%, P = .0001). A multivariable Cox proportional hazards model identified prior sternotomy as a significant independent predictor of mortality, in addition to age, female gender, congenital cardiomyopathy, need for ventilation, mechanical circulatory support, dialysis prior to transplant, pretransplant serum bilirubin (≥ 3 mg/dL), and preoperative serum creatinine (≥ 2 mg/dL). CONCLUSIONS: Prior sternotomy is associated with an excess 3.3% mortality and higher morbidity within the first 60 days after heart transplantation, as measured by frequency of dialysis, drug-treated infections, and strokes. Conditional 5-year survival after 60 days is unaffected by prior sternotomy. These findings should be taken into account for risk assessment of patients undergoing heart transplantation.


Subject(s)
Heart Failure/surgery , Heart Transplantation/methods , Sternotomy/methods , Adult , Aged , Cardiomyopathies/complications , Cardiomyopathies/congenital , Databases, Factual , Female , Graft Rejection , Heart Failure/mortality , Humans , Male , Middle Aged , Multivariate Analysis , Proportional Hazards Models , Risk Assessment , Treatment Outcome , United States
12.
Perfusion ; 29(1): 89-93, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23842614

ABSTRACT

The Fontan procedure represents the final stage of the transition to single ventricle physiology. Conversion of very complex congenital heart anatomy, such as hypoplastic left heart syndrome, double-outlet right ventricle or double-inlet left ventricle, to a single ventricle has grown in popularity as morbidity and mortality have improved. As these patients grow, survivors are at risk for impaired ventricular dysfunction, plastic bronchitis, protein-losing enteropathy and late failure. Late failing Fontan patients represent a particularly vexing scenario for clinicians, as the only durable treatment option is cardiac transplantation. However, in the short-term, some of these patients require support beyond medical management, with mechanical circulatory support via extracorporeal life support or a ventricular assist device. We report the successful bridge of an adolescent female post-Fontan conversion with late severe cardiac failure. The patient was initially resuscitated with extracorporeal life support, transitioned to a single Berlin Heart EXCOR® ventricular assist device and, subsequently, underwent successful cardiac transplantation.


Subject(s)
Cardiopulmonary Resuscitation/methods , Heart Failure/therapy , Heart Transplantation , Adolescent , Cardiopulmonary Resuscitation/standards , Extracorporeal Membrane Oxygenation/standards , Female , Heart-Assist Devices/standards , Humans , Treatment Outcome
13.
Perfusion ; 29(1): 82-8, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23868320

ABSTRACT

Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with end-stage biventricular heart failure as a bridge to heart transplantation since 1985 and has had FDA approval since 2004. However, of the 1,061 patients placed on the TAH-t, only 21 (2%) were under the age 18. SynCardia Systems, Inc. recommends a minimum patient body surface area (BSA) of 1.7 m(2), thus, limiting pediatric application of this device. This unique case report shares this pediatric institution's first experience with the TAH-t. A 14-year-old male was admitted with dilated cardiomyopathy and severe biventricular heart failure. The patient rapidly decompensated, requiring extracorporeal life support. An echocardiogram revealed severe biventricular dysfunction and diffuse clot formation in the left ventricle and outflow tract. The decision was made to transition to biventricular assist device. The biventricular failure and clot formation helped guide the team to the TAH-t, in spite of a BSA (1.5 m(2)) below the recommendation of 1.7 m(2). A computed tomography (CT) scan of the thorax, in conjunction with a novel three-dimensional (3D) modeling system and team, assisted in determining appropriate fit. Chest CT and 3D modeling following implantation were utilized to determine all major vascular structures were unobstructed and the bronchi were open. The virtual 3D model confirmed appropriate device fit with no evidence of compression to the left pulmonary veins. The postoperative course was complicated by a left lung opacification. The left lung anomalies proved to be atelectasis and improved with aggressive recruitment maneuvers. The patient was supported for 11 days prior to transplantation. Chest CT and 3D modeling were crucial in assessing whether the device would fit, as well as postoperative complications in this smaller pediatric patient.


Subject(s)
Cardiomyopathy, Dilated/surgery , Heart Failure/surgery , Heart Transplantation/methods , Heart, Artificial , Adolescent , Cardiomyopathy, Dilated/therapy , Heart Failure/therapy , Humans , Male
14.
Transplant Proc ; 45(2): 792-7, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23267784

ABSTRACT

Invasive fungal infections are a significant complication of solid organ transplantation. Here we report the first case of concurrent invasive pulmonary fungal infection caused by Aspergillus fumigatus and Mucor species in a heart transplant recipient. Polymicrobial mold infection is rare but should be considered in solid organ transplant recipients who fail to respond to initial antifungal therapy targeting a single organism. It is also of interest that in addition to potent immunosuppression and prolonged voriconazole therapy, possible airway fungal colonization following hurricane Katrina cleaning efforts might have contributed to this dual invasive mold infection.


Subject(s)
Air Microbiology , Cardiomyopathy, Dilated/surgery , Cyclonic Storms , Environmental Exposure , Heart Transplantation/immunology , Immunosuppressive Agents/adverse effects , Invasive Pulmonary Aspergillosis/microbiology , Mucormycosis/microbiology , Antifungal Agents/therapeutic use , Heart Transplantation/adverse effects , Humans , Invasive Pulmonary Aspergillosis/diagnosis , Invasive Pulmonary Aspergillosis/drug therapy , Invasive Pulmonary Aspergillosis/immunology , Male , Middle Aged , Mucormycosis/diagnosis , Mucormycosis/drug therapy , Mucormycosis/immunology , Pyrimidines/therapeutic use , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Triazoles/therapeutic use , Voriconazole
15.
J Heart Lung Transplant ; 20(6): 654-6, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11404171

ABSTRACT

BACKGROUND: In the past, explantation of the Cardio West total artificial heart (TAH) has been technically challenging because of the presence of dense adhesions and extremely thickened pericardium. To prevent this, we constructed a synthetic neo-pericardium in 14 patients. METHODS: Using expanded polytetrafluoroethylene (e-PTFE) membrane, we constructed a pericardium within the pericardium, or "neo-pericardium," completely covering the Cardio West TAH separating the native atria from the native pericardium, and wrapping the ascending aorta from the outflow conduit distally for about 5 to 7 cm. RESULTS: Of the 14 patients, 9 were transplanted and could be evaluated, 3 died on device support, and 2 are currently on device support. In each case, we attained faster (by 25 minutes) and easier reentry through the sternum. Surgical planes around the aorta, over the right and left atria, and throughout the pericardial space became apparent immediately after e-PTFE membrane removal. The pericardium and related tissues although slightly thickened (<2 mm) were pliable compared with our previous 36 patients, with very thick adherent pericardium over the device and native atria. CONCLUSIONS: The plastic materials forming the ventricular housing and drivelines of the Cardio West TAH and the Dacron outflow conduits have in the past caused profound local inflammatory reactions, resulting in extremely dense adhesions and thickened adherent pericardium. Using e-PTFE membrane to fashion a complete neo-pericardium and to wrap the ascending aorta at the time of Cardio West implantation dramatically reduces adhesions and pericardial thickening and facilitates explantation.


Subject(s)
Cardiac Surgical Procedures/methods , Device Removal/methods , Equipment Design/instrumentation , Heart, Artificial , Pericardium/surgery , Adult , Aorta/pathology , Humans , Middle Aged , Pericarditis/prevention & control , Polytetrafluoroethylene
16.
Ann Thorac Surg ; 71(3): 1003-4, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11269409

ABSTRACT

A Thoratec left ventricular assist device (LVAD) was used to support a 7-year-old 17-kg boy with viral cardiomyopathy for 23 days before heart transplantation. The boy is still living more than 1 year posttransplant, and functional except for some spastic paresis of the left hand, a residual from a stroke during device support. He is the smallest person to be supported with this device. We discuss techniques for using the Thoratec in children.


Subject(s)
Heart Transplantation , Heart-Assist Devices , Preoperative Care , Body Weight , Child , Humans , Male
17.
Ann Thorac Surg ; 71(3 Suppl): S92-7; discussion S114-5, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11265873

ABSTRACT

BACKGROUND: Device selection has historically been supported by minimal comparative data. Since 1994, we have implanted 43 patients with the CardioWest Total Artificial Heart (CW), 23 with the Novacor Left Ventricular Assist System (N), and 26 with the Thoratec Ventricular Assist System (T). This experience provides a basis for our device selection criteria. METHODS: We reviewed retrospectively the results for survival, stroke, and infection in the CW, N, and T groups. Statistical methods included the Student's t-test, chi2 analysis, and Kaplan-Meier actuarial survival curves. RESULTS: The T group patients were younger and smaller sized than the CW or N group. The CW group had the highest mean central venous pressure (CVP) and lowest mean cardiac index. Survival to transplantation was 75% for CW, 57% for N, and 38% for T. Multiple organ failure postimplant caused most deaths in the CW and T groups. Right heart failure and stroke caused most N deaths. Linearized stroke rates (event/patient-month) were 0.03 for CW, 0.28 for N, and 0.08 for T. Serious infections were found in 20% of CW, 30% of N, and 8% of T patients, but linearized rates showed little difference and death from infection was rare. CONCLUSIONS: The N device should be used in "stable" patients with body surface area (BSA) greater than 1.7 m2 and with minimal right heart failure. Unstable patients with biventricular failure should receive a CW if the BSA is greater than 1.7 m2 or a T if they are smaller.


Subject(s)
Heart Failure/surgery , Heart Transplantation , Heart, Artificial , Preoperative Care , Adolescent , Adult , Aged , Equipment Design , Female , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Prosthesis Design , Retrospective Studies
18.
J Card Surg ; 16(3): 222-7, 2001.
Article in English | MEDLINE | ID: mdl-11824667

ABSTRACT

There has been a quest for an artificial organ that can replace the heart for decades. Remarkable advances were made in the second half of the twentieth century in the fields of medicine and engineering that led to the development of several devices with the intention of totally replacing the human heart. Some of these devices, like the Jarvik artificial heart, were utilized initially as a permanent replacement for the failing heart. It became more successful as a bridge to heart transplantation (BTT) in the years that followed its introduction. Currently the CardioWest total artificial heart (TAH) is the only device in clinical use with the intention of bridging patients to heart transplantation. Two new TAHs are being developed with the intention of being used as an alternative to transplantation (ATT) or on a permanent basis. The next 100 years will bring revolutionary new designs and advances in the field of end stage heart disease that may only be ideas at the present time.


Subject(s)
Heart, Artificial , Heart Transplantation , Humans , Patient Selection , Prosthesis Design
19.
Semin Thorac Cardiovasc Surg ; 12(3): 238-42, 2000 Jul.
Article in English | MEDLINE | ID: mdl-11052191

ABSTRACT

The CardioWest total artificial heart (TAH), formerly known as the Jarvik-7 and then the Symbion heart, is the only TAH in current clinical use. A new study, approved by the Food and Drug Administration (FDA), was initiated in 1993 with the goal of approving this pump for commercial release. Since then, 145 CardioWest TAHs have been implanted, including 37 pumps in 36 patients at our center. Our 36 patients were studied prospectively according to the investigational device exemption protocol approved by the FDA. Clinical and hemodynamic data obtained upon patients' entry into the study identified this group as mortally ill. After receiving a CardioWest TAH, 29 of the 36 patients (81%) survived to heart transplantation, and 26 (72% of the total group and 90% of the transplant recipients) have survived for up to 7 years (average, 24 months). Multicomponent anticoagulation, based on readily available tests, and the intrinsic properties of the TAH have resulted in a low linearized stroke rate of 0.48 event per patient-year. There have been no device-related mediastinal infections. In dying patients with nonexistent or severely compromised biventricular function, the CardioWest TAH has proved safe and effective, allowing a 72% survival rate for an average of 24 months.


Subject(s)
Heart Failure/surgery , Heart, Artificial/statistics & numerical data , Patient Selection , Prosthesis Implantation/methods , Adult , Arizona , Female , Heart, Artificial/adverse effects , Heart-Assist Devices/statistics & numerical data , Humans , Male , Middle Aged , Prosthesis Implantation/statistics & numerical data , Retrospective Studies , Survival Analysis , Treatment Outcome
20.
J Heart Lung Transplant ; 19(5): 504-6, 2000 May.
Article in English | MEDLINE | ID: mdl-10808160

ABSTRACT

Patients implanted with mechanical circulatory support devices (MCSD's) are at high risk for post-operative bleeding at cardiac transplantation. However, the magnitude of the risk and transfusion requirements for MCSD patients at the time of transplantation have not been previously reported. The purpose of this study was to characterize and compare the bleeding characteristics and transfusion requirements of 3 sub-groups of cardiac transplant patients: primary (n = 45), redo (n = 26), and MCSD (n = 23) patients.


Subject(s)
Blood Component Transfusion , Blood Loss, Surgical/prevention & control , Heart Transplantation , Heart-Assist Devices , Postoperative Hemorrhage/prevention & control , Cardiopulmonary Bypass , Humans , Intraoperative Period , Middle Aged , Platelet Count , Postoperative Hemorrhage/blood , Retrospective Studies , Risk Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...