Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
Hellenic J Cardiol ; 2024 May 08.
Article in English | MEDLINE | ID: mdl-38729347

ABSTRACT

AIMS: Implantable loop recorders (ILRs) are increasingly being used for long-term cardiac monitoring in different clinical settings. The aim of this study was to investigate the real-world performance of ILRs-including the time to diagnosis- in unselected patients with different ILR indications. METHODS AND RESULTS: In this multicenter, observational study, 871 patients with an indication of pre-syncope/syncope (61.9%), unexplained palpitations (10.4%), and atrial fibrillation (AF) detection with a history of cryptogenic stroke (CS) (27.7%) underwent ILR implantation. The median follow-up was 28.8 ± 12.9 months. In the presyncope/syncope group, 167 (31%) received a diagnosis established by the device. Kaplan-Meier estimates indicated that 16.9% of patients had a diagnosis at 6 months, and the proportion increased to 22.5% at 1 year. Of 91 patients with palpitations, 20 (22%) received a diagnosis based on the device. The diagnosis established at 12.2% of patients at 6 months, and the proportion increased to 13.3% at 1 year. Among 241 patients with CS, 47 (19.5%) were diagnosed with AF. The diagnostic yield of the device was 10.4% at 6 months and 12.4% at 1 year. In all cases, oral anticoagulation was initiated. Overall, ILR diagnosis altered the therapeutic strategy in 26.1% in presyncope/syncope group, 2.2% in palpitations group, and 3.7% in CS group in addition to oral anticoagulation initiation. CONCLUSIONS: In this real-world patient population, ILR determines diagnosis and initiates a new therapeutic management in nearly one fourth of patients. ILR implantation is valuable in the evaluation of patients with unexplained presyncope/syncope, CS and palpitations.

3.
Curr Probl Cardiol ; 49(3): 102358, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38169203

ABSTRACT

Testing for myocardial ischemia in patients presenting with sustained monomorphic Ventricular Tachycardia(VT) even without evidence of acute myocardial infarction is a tempting strategy that is frequently utilized in clinical practice. Monomorphic VT is mainly caused by re-entry around chronic myocardial scar and active ischemia has no role in its pathogenesis, thus making testing for ischemia futile, at least in theory. This systematic literature review sought to address the usefulness of ischemia testing (mainly coronary angiography) in patients presenting with monomorphic VT through 8 selected studies after evaluating a total of 130 published manuscripts. Particularly, we sought to unveil whether coronary angiography and possibly concomitant revascularization leads to lesser tachycardia recurrence. Our conclusion can be summarized as follows: this approach whether combined with revascularization or not, does not seem to reduce VT recurrence nor does it affect mortality in such patients. Even though most of the published literature points at this direction, validation from randomized controlled trials is imperative.


Subject(s)
Coronary Artery Disease , Myocardial Infarction , Myocardial Ischemia , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/etiology , Myocardial Ischemia/complications , Myocardial Ischemia/diagnosis , Myocardial Ischemia/pathology , Myocardium
6.
Heart Fail Rev ; 28(4): 865-878, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36872393

ABSTRACT

Risk stratification for sudden cardiac death in dilated cardiomyopathy is a field of constant debate, and the currently proposed criteria have been widely questioned due to their low positive and negative predictive value. In this study, we conducted a systematic review of the literature utilizing the PubMed and Cochrane library platforms, in order to gain insight about dilated cardiomyopathy and its arrhythmic risk stratification utilizing noninvasive risk markers derived mainly from 24 h electrocardiographic monitoring. The obtained articles were reviewed in order to register the various electrocardiographic noninvasive risk factors used, their prevalence, and their prognostic significance in dilated cardiomyopathy. Premature ventricular complexes, nonsustained ventricular tachycardia, late potentials on Signal averaged electrocardiography, T wave alternans, heart rate variability and deceleration capacity of the heart rate, all have both some positive and negative predictive value to identify patients in higher likelihood for ventricular arrhythmias and sudden cardiac death. Corrected QT, QT dispersion, and turbulence slope-turbulence onset of heart rate have yet to establish a predictive correlation in the literature. Although ambulatory electrocardiographic monitoring is frequently used in clinical practice in DCM patients, no single risk marker can be used for the selection of patients at high-risk for malignant ventricular arrhythmic events and sudden cardiac death who could benefit from the implantation of a defibrillator. More studies are needed in order to establish a risk score or a combination of risk factors with the purpose of selecting high-risk patients for ICD implantation in the context of primary prevention.


Subject(s)
Cardiomyopathy, Dilated , Electrocardiography, Ambulatory , Humans , Electrocardiography, Ambulatory/adverse effects , Cardiomyopathy, Dilated/complications , Electrocardiography , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Arrhythmias, Cardiac/complications , Risk Factors , Prognosis
8.
J Interv Card Electrophysiol ; 66(2): 471-481, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36063282

ABSTRACT

BACKGROUND: The strategy of cardiac implantable electronic device (CIED) implantations performed as day-case admissions has gained a wider acceptance overtime; however, data on safety are still limited. This study aims to investigate the safety of a same-day discharge protocol introduced in our hospital for the postprocedural management of patients undergoing CIED implantation. METHODS: Α prospective, non-interventional, non-randomised study performed in a single high-volume implanting centre for a 16-month period (March 2020 to June 2021). At total of 821 of 965 (85.1%) patients scheduled for elective CIED implantation were considered to be eligible for inclusion in the Short-stay Device Management Protocol. These patients were compared with a historical group of 932 patients, meeting the same inclusion criteria. RESULTS: Procedure was successful in 812 patients (98.9%), committed to same-day discharge versus 921 of 932 patients (98.8%) admitted for overnight stay (p = 0.87). Overall, 90-day complication rate was comparable in both groups (4.14% vs 4.07%, p = 0.95), as was major (1.46% vs. 1.82%, p = 0.55) and minor (2.67% vs. 2.25%, p = 0.64) complication rates. The composite early post-procedural complication rates and late post-procedural complication rates were comparable among groups (0.97 vs 1.18%, p = 0.70 and 0.73% vs 0.64%, p = 0.83, respectively). Six hundred sixty-seven patients (84%) preferred the same-day discharge strategy. Finally, a reduction of 792 bed-days was recorded, resulting in possible financial Health System benefits. CONCLUSIONS: Same-day discharge is feasible and safe in the majority of patients referred for CIED implantation. Additionally, same-day discharge is preferred by patients and may reduce procedure-related costs due to significant bed-day reductions.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Patient Discharge , Prospective Studies , Hospitalization , Retrospective Studies
9.
World J Cardiol ; 14(3): 139-151, 2022 Mar 26.
Article in English | MEDLINE | ID: mdl-35432775

ABSTRACT

Annual arrhythmic sudden cardiac death ranges from 0.6% to 4% in ischemic cardiomyopathy (ICM), 1% to 2% in non-ischemic cardiomyopathy (NICM), and 1% in hypertrophic cardiomyopathy (HCM). Towards a more effective arrhythmic risk stratification (ARS) we hereby present a two-step ARS with the usage of seven non-invasive risk factors: Late potentials presence (≥ 2/3 positive criteria), premature ventricular contractions (≥ 30/h), non-sustained ventricular tachycardia (≥ 1episode/24 h), abnormal heart rate turbulence (onset ≥ 0% and slope ≤ 2.5 ms) and reduced deceleration capacity (≤ 4.5 ms), abnormal T wave alternans (≥ 65µV), decreased heart rate variability (SDNN < 70ms), and prolonged QTc interval (> 440 ms in males and > 450 ms in females) which reflect the arrhythmogenic mechanisms for the selection of the intermediate arrhythmic risk patients in the first step. In the second step, these intermediate-risk patients undergo a programmed ventricular stimulation (PVS) for the detection of inducible, truly high-risk ICM and NICM patients, who will benefit from an implantable cardioverter defibrillator. For HCM patients, we also suggest the incorporation of the PVS either for the low HCM Risk-score patients or for the patients with one traditional risk factor in order to improve the inadequate sensitivity of the former and the low specificity of the latter.

10.
Hellenic J Cardiol ; 64: 24-29, 2022.
Article in English | MEDLINE | ID: mdl-35017036

ABSTRACT

OBJECTIVE: Syncope, whose cause is unknown after an initial assessment, has an uncertain prognosis. It is critical to identify patients at the highest risk who may require a pacemaker and to identify the cause of recurrent syncope to prescribe proper therapy. The aim of this study was to evaluate the effect of permanent pacing on the incidence of syncope in patients with unexplained syncope and electrophysiology study (EPS)-proven atrioventricular (AV) node disease. METHODS: This was an observational study based on a prospective registry of 236 consecutive patients (60.20 ± 18.66 years, 63.1% male, 60.04 ± 9.50 bpm) presenting with recurrent unexplained syncope attacks admitted to our hospital for invasive EPS. The decision to implant a permanent pacemaker was made in all cases by the attending physicians according to the results of the EPS. A total of 135 patients received the antibradycardia pacemaker (ABP), while 101 patients were declined. RESULTS: The mean of reported syncope episodes was 1.97 ± 1.10 (or presyncope 2.17 ± 1.50) before they were referred for a combined EP-guided diagnostic and therapeutic approach. Over a mean follow-up of approximately 4 years (49.19 ± 29.58 months), the primary outcome event (syncope) occurred in 31 of 236 patients (13.1%), and 6 of 135 (4.4%) patients in the ABP group as compared to 25 of 101 (24.8%) in the no pacemaker group (p < 0.001). CONCLUSION: Among patients with a history of unexplained syncope, a set of positivity criteria for the presence of EPS-defined AV node disease identifies a subset of patients who will benefit from permanent pacing.


Subject(s)
Atrioventricular Node , Pacemaker, Artificial , Cardiac Pacing, Artificial/methods , Electrophysiology , Female , Humans , Male , Pacemaker, Artificial/adverse effects , Syncope/diagnosis , Syncope/etiology , Syncope/therapy
13.
Hellenic J Cardiol ; 64: 77-86, 2022.
Article in English | MEDLINE | ID: mdl-34843996

ABSTRACT

His bundle pacing (HBP) is proven to be a safe and effective alternative pacing modality that, in addition, avoids pacemaker-induced cardiomyopathy (PICM) by achieving a "physiological" ventricular stimulation, via the native conduction system. Indications include various causes of bradycardia requiring anti-bradycardic pacing, inadequately controlled atrial fibrillation requiring AV node ablation and established PICM. In addition, HBP may also be used as an alternative therapy for patients with heart failure (HF) and an indication for cardiac resynchronization therapy (CRT). Available data show several advantages of HBP with regard to preservation or restoration of intra- and inter-ventricular synchronization; improvement in left ventricular ejection fraction, functional status and quality of life; decrease in atrial fibrillation incidence and improvement in HF hospitalization rates, compared with conventional pacing. Nevertheless, superiority in terms of mortality rates has not been consistently demonstrated, and the long-term efficacy and safety of HBP remain to be proven. In the present manuscript, we review the status of HBP and present our current experience with this novel pacing modality.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Heart Failure , Atrial Fibrillation/therapy , Bradycardia/therapy , Bundle of His , Cardiac Pacing, Artificial/adverse effects , Electrocardiography , Heart Failure/therapy , Humans , Quality of Life , Stroke Volume , Treatment Outcome , Ventricular Function, Left/physiology
14.
Tob Prev Cessat ; 7: 16, 2021.
Article in English | MEDLINE | ID: mdl-33644498

ABSTRACT

INTRODUCTION: The unequivocal association between exposure to smoke and numerous complications of pregnancy, demonstrated in the last decades, has led to a significant decrease of smoking rates in pregnancy. The aim of the present study was to determine the prevalence of maternal smoking and to elucidate factors predisposing to it among pregnant women in Athens, Greece. METHODS: A population of 1700 pregnant women (mean age: 31.2±5.5 years) who visited consecutively the Cardiology Department of Helena Venizelou Maternity Hospital in Athens, Greece, between September 2016 and August 2017, was prospectively analyzed. Data regarding changes in the future mother's smoking habit as well as different sociodemographic factors potentially related to these changes were recorded. RESULTS: Of the 1700 participants, 704 (41.4%) were smokers, and of those 52.4% quit smoking after knowledge of their pregnancy status. The overall prevalence of smoking in pregnancy was 19.7%. Prevalence was higher in women who were aged <20 years (p=0.038), were multipara (p=0.032), had ≤12 years of education (p=0.044) and had a partner who was a smoker (p=0.047). Women aged ≤20 years were more likely to be persistent smokers at the beginning of pregnancy and demonstrated a higher prevalence of smoking during pregnancy (42.2% vs 19.7% in the overall study population). CONCLUSIONS: Our data demonstrate that maternal smoking during pregnancy still remains a major public health issue in Greece with a prevalence higher than most other industrialized countries.

16.
J Cardiovasc Electrophysiol ; 32(2): 491-499, 2021 02.
Article in English | MEDLINE | ID: mdl-33345428

ABSTRACT

INTRODUCTION: Transvenous lead extraction (TLE) is critical in the long-term management of patients with cardiac implanted electronic devices (CIEDs). The aim of the study is to evaluate the outcomes of TLE and to investigate the impact of infection. METHODS AND RESULTS: Data of patients undergoing extraction of permanent pacemaker and defibrillator leads during October 2014-September 2019 were prospectively analyzed. Overall, 242 consecutive patients (aged 71.0 ± 14.0 years, 31.4% female), underwent an equal number of TLE operations for the removal of 516 leads. Infection was the commonest indication (n = 201, 83.1%). Mean implant-to-extraction duration was 7.6 ± 5.4 years. Complete procedural success was recorded in 96.1%, and clinical procedural success was achieved in 97.1% of attempted lead extractions. Major complications occurred in two (0.8%) and minor complications in seven (2.9%) patients. Leads were removed exclusively by using locking stylets in 65.7% of the cases. In the subgroup of noninfective patients, advanced extraction tools were more frequently required compared to patients with CIED infections, to extract leads (success only with locking stylet: 55.8% vs. 67.8%, p = .032). In addition, patients without infection demonstrated lower complete procedural success rates (90.7% vs. 97.2%, p = .004), higher major complication rates (2.4% vs. 0.5%, p = .31) and longer procedural times (136 ± 13 vs. 111 ± 15 min, p = .001). CONCLUSIONS: Our data demonstrate high procedural efficacy and safety and indicate that in patients with noninfective indications, the procedure is more demanding, thus supporting the hypothesis that leads infection dissolves and/or prohibits the formation of fibrotic adherences.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Defibrillators, Implantable/adverse effects , Device Removal/adverse effects , Female , Humans , Male , Pacemaker, Artificial/adverse effects , Retrospective Studies , Treatment Outcome
18.
Metabol Open ; 1: 11-18, 2019 Mar.
Article in English | MEDLINE | ID: mdl-32812917

ABSTRACT

BACKGROUND/OBJECTIVE: Dietary patterns may play an important role in the prognosis of heart failure. METHODS: Dietary habits, sleeping habits, physical activity and anxiety and depression status were recorded in 326 patients (90 females, mean age 73.45 ±â€¯10.9 years) with ischemic heart failure prospectively followed for 30 months. RESULTS: Lower ΗADS-depression scores (p = 0.03), a low-fat meat diet (p = 0.035) and moderate coffee consumption (p = 0.005) were associated with better prognosis. Non-significant differences were recorded in outcomes with regard to consumption of other dietary categories. CONCLUSIONS: A balanced diet as well as emphasis on the treatment of depression may improve outcomes in ischemic heart failure.

19.
Curr Med Chem ; 26(5): 824-836, 2019.
Article in English | MEDLINE | ID: mdl-28721832

ABSTRACT

BACKGROUND: Prevention of thromboembolic disease, mainly stroke, with oral anticoagulants remains a major therapeutic goal in patients with atrial fibrillation. Unfortunately, despite the high efficacy, anticoagulant therapy is associated with a significant risk of, frequently catastrophic, and hemorrhagic complications. Among different clinical and laboratory parameters related to an increased risk of bleeding, several biological markers have been recognized and various risk scores for bleeding have been developed. OBJECTIVES/METHODS: The aim of the present study is to review current evidence regarding the different biomarkers associated with raised bleeding risk in atrial fibrillation. RESULTS: Data originating from large cohorts or the recent large-scale trials of atrial fibrillation have linked numerous individual biomarkers to an increased bleeding risk. Such a relation was revealed for markers of cardiac physiology, such as troponin, BNP and NT-proBNP, markers of renal function, such as GFR and Cystatin or hepatic function, markers involving the system of coagulation, such as D-dimer and Von Willebrand factor, hematologic markers, such as low haemoglobin or low platelets, inflammatory markers, such as interleukin-6, other factors such as GDF-15 and vitamin-E and finally genetic polymorphisms. Many such biomarkers are incorporated in the bleeding risk schemata developed for the prediction of the hemorrhagic risk. CONCLUSIONS: Biomarkers were introduced in clinical practice in order to better estimate the potential risk of haemorrhage in these patients and increase the prognostic impact of clinical risk scores. In the last years this concept is gaining significant importance.


Subject(s)
Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Atrial Fibrillation/complications , Hemorrhage/chemically induced , Hemorrhage/diagnosis , Thromboembolism/prevention & control , Animals , Biomarkers/analysis , Humans , Risk Factors , Stroke/etiology , Stroke/prevention & control , Thromboembolism/etiology
20.
J Cardiovasc Electrophysiol ; 30(3): 299-307, 2019 03.
Article in English | MEDLINE | ID: mdl-30516299

ABSTRACT

INTRODUCTION: Cardiac perforation of the right ventricle associated with pacemaker or implantable cardioverter defibrillator (ICD) leads' implantation is uncommon, albeit potentially life-threatening, complication. The aim of this study is to further identify the optimal therapeutic strategy, especially when lead dislocation has occurred outside the pericardial sac. METHODS AND RESULTS: The study population included 10 consecutive patients (six female, mean age: 66.5 years old) diagnosed with early ventricular lead perforation following a pacemaker or ICD implantation, with significant protrusion inside the pericardial sac (n = 2) or migration of the lead at the pleural space ( n = 3), the diaphragm ( n = 1), or the abdominal cavity ( n = 4), during the period 2013-2017. All patients were symptomatic; however, individuals presenting with hemodynamic instability were excluded. The outcome of the percutaneous therapeutic approach was retrospectively assessed. All patients underwent a successful removal of the perforating lead percutaneously at the electrophysiology lab, by direct traction, and repositioning in another location of the right ventricle. The operation was performed by a multidisciplinary team, under continuous hemodynamic and transesophageal echocardiographic monitoring and cardiac surgical backup. The periprocedural period was uneventful. Subjects were followed up for at least 1 year. Interestingly, all patients developed a type of postcardiac injury syndrome, successfully treated with a 3-month regimen of ibuprofen and colchicine. CONCLUSION: Percutaneous traction and repositioning of the perforating ventricular lead are effective, safe, and less invasive compared with the thoracotomy method in hemodynamically stable patients when dislocation has occurred outside the pericardial sac provided that there is no visceral organs injury.


Subject(s)
Defibrillators, Implantable , Device Removal , Foreign-Body Migration/surgery , Heart Injuries/surgery , Heart Ventricles/surgery , Pacemaker, Artificial , Prosthesis Implantation/instrumentation , Aged , Aged, 80 and over , Device Removal/adverse effects , Female , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Heart Injuries/diagnostic imaging , Heart Injuries/etiology , Heart Ventricles/diagnostic imaging , Heart Ventricles/injuries , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Implantation/adverse effects , Reoperation , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...