Dent Res J (Isfahan) ; 18: 30, 2021.
Article in English | MEDLINE | ID: mdl-34322206

ABSTRACT

BACKGROUND: The flexural strength (FS) of a denture base material is of great concern, and many approaches have been used to strengthen the denture acrylic resins. The present study aimed to evaluate the effect of high-performance polymer (BioHPP) and metal mesh reinforcement on the FS of a heat-cured poly methyl methacrylate (PMMA) acrylic resin. MATERIALS AND METHODS: This experimental study was done on 30 rectangular specimens (64 mm × 13 mm × 3 mm) of a heat-cured PMMA resin. The specimens were divided into three groups (n = 10) to be reinforced with either metal mesh or BioHPP mesh; one group was left nonreinforced, serving as the control group. The FS of specimens was assessed through a 3-point bending test by using a universal testing machine at a crosshead speed of 2 mm/min. Kruskal-Wallis H and Dunn's post hoc tests were used to compare the FS among the groups (alpha = 0.05). RESULTS: The FS in the metal-reinforced group was statistically significantly higher than the two other groups (P < 0.001). However, the FS of the BioHPP-reinforced samples was not statistically significantly higher than the nonreinforced ones (P = 0.614). CONCLUSION: Reinforcing the PMMA with metal mesh significantly enhances its FS while BioHPP has no significant effect on the PMMA FS.

2.
Eur J Dent ; 10(2): 259-263, 2016.
Article in English | MEDLINE | ID: mdl-27095908

ABSTRACT

OBJECTIVES: This study aimed to compare the dimensional accuracy of two indexing materials, an acrylic resin (GC pattern resin) and a castable composite (Bredent). The effect of time lapse until investment was also investigated. MATERIALS AND METHODS: Two standardized brass dies 15 mm apart were prepared and then 20 identical coping-bar assemblies were designed and fabricated by a rapid prototyping device. Each bar was sectioned at the center, and indices were fabricated from an acrylic resin or castable composite (n = 10 per group). The distances between the reference points were measured with a digital microscope at ×80 magnifications at 15 min, 60 min, and 24 h after indexing. Data were statically analyzed using repeated-measure ANOVA (α = 0.05). RESULTS: The distance between the reference points without the coping being joined was considered as the baseline measurement (control group). The mean distance was 19.30 ± 0.04 mm between the reference points where the copings were not joined. When indexed with acrylic resin, the mean ± standard deviation (SD) dimensions were 19.27 ± 0.087 mm (15 min), 19.25 ± 0.09 mm (60 min), and 18.98 ± 0.1 mm (24 h). The mean ± SD dimensions for composite were 19.29 ± 0.087 mm (15 min), 19.28 ± 0.08 mm (60 min), and 19.26 ± 0.08 mm (24 h). All tested groups showed significant differences compared to the control group except when it was indexed with composite and where the distances were measured after 15 and 60 min (P > 0.05). CONCLUSIONS: The most accurate indexed-assemblies belonged to castable composite at 15 and 60 min.

SELECTION OF CITATIONS
SEARCH DETAIL