Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
J Am Heart Assoc ; 13(9): e031816, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38639365

ABSTRACT

BACKGROUND: Data on impact of COVID-19 vaccination and outcomes of patients with COVID-19 and acute ischemic stroke undergoing mechanical thrombectomy are scarce. Addressing this subject, we report our multicenter experience. METHODS AND RESULTS: This was a retrospective analysis of patients with COVID-19 and known vaccination status treated with mechanical thrombectomy for acute ischemic stroke at 20 tertiary care centers between January 2020 and January 2023. Baseline demographics, angiographic outcome, and clinical outcome evaluated by the modified Rankin Scale score at discharge were noted. A multivariate analysis was conducted to test whether these variables were associated with an unfavorable outcome, defined as modified Rankin Scale score >3. A total of 137 patients with acute ischemic stroke (48 vaccinated and 89 unvaccinated) with acute or subsided COVID-19 infection who underwent mechanical thrombectomy attributable to vessel occlusion were included in the study. Angiographic outcomes between vaccinated and unvaccinated patients were similar (modified Thrombolysis in Cerebral Infarction ≥2b: 85.4% in vaccinated patients versus 86.5% in unvaccinated patients; P=0.859). The rate of functional independence (modified Rankin Scale score, ≤2) was 23.3% in the vaccinated group and 20.9% in the unvaccinated group (P=0.763). The mortality rate was 30% in both groups. In the multivariable analysis, vaccination status was not a significant predictor for an unfavorable outcome (P=0.957). However, acute COVID-19 infection remained significant (odds ratio, 1.197 [95% CI, 1.007-1.417]; P=0.041). CONCLUSIONS: Our study demonstrated no impact of COVID-19 vaccination on angiographic or clinical outcome of COVID-19-positive patients with acute ischemic stroke undergoing mechanical thrombectomy, whereas worsening attributable to COVID-19 was confirmed.


Subject(s)
COVID-19 Vaccines , COVID-19 , Ischemic Stroke , Thrombectomy , Vaccination , Humans , COVID-19/complications , COVID-19/therapy , COVID-19/mortality , Male , Female , Ischemic Stroke/mortality , Ischemic Stroke/surgery , Retrospective Studies , Aged , Middle Aged , Treatment Outcome , COVID-19 Vaccines/adverse effects , SARS-CoV-2 , Aged, 80 and over
2.
Transl Neurosci ; 14(1): 20220315, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-37854584

ABSTRACT

Prion diseases and the prion protein are only partially understood so far in many aspects. This explains the continued research on this topic, calling for an overview on the current state of knowledge. The main objective of the present review article is to provide a comprehensive up-to-date presentation of all major features of human prion diseases bridging the gap between basic research and clinical aspects. Starting with the prion protein, current insights concerning its physiological functions and the process of pathological conversion will be highlighted. Diagnostic, molecular, and clinical aspects of all human prion diseases will be discussed, including information concerning rare diseases like prion-associated amyloidoses and Huntington disease-like 1, as well as the question about a potential human threat due to the transmission of prions from prion diseases of other species such as chronic wasting disease. Finally, recent attempts to develop future therapeutic strategies will be addressed.

3.
BMC Cardiovasc Disord ; 23(1): 131, 2023 03 11.
Article in English | MEDLINE | ID: mdl-36906545

ABSTRACT

BACKGROUND: The role of cardiac magnetic resonance imaging in the early management of chronic cardiac inflammatory conditions is growing. Our case enlightens the benefit of quantitative mapping in the monitoring and treatment guidance in systemic sarcoidosis. CASE PRESENTATION: We report about a 29-year-old man with an ongoing dyspnea and bihilar lymphadenopathy, suggesting sarcoidosis. Cardiac magnetic resonance showed high mapping values, but no scarring. In follow-ups, cardiac remodeling was noted; cardioprotective treatment normalized cardiac function and mapping markers. Definitive diagnosis was achieved in extracardiac lymphatic tissue during a relapse. CONCLUSION: This case shows the role that mapping markers can play in the detection and treatment at early stage of systemic sarcoidosis.


Subject(s)
Cardiomyopathies , Sarcoidosis , Male , Humans , Adult , Cardiomyopathies/diagnosis , Myocardium/pathology , Magnetic Resonance Imaging , Heart , Sarcoidosis/therapy
4.
JACC Cardiovasc Imaging ; 14(8): 1548-1557, 2021 08.
Article in English | MEDLINE | ID: mdl-33865770

ABSTRACT

OBJECTIVES: The goal of this study was to examine prognostic relationships between cardiac imaging measures and cardiovascular outcome in people living with human immunodeficiency virus (HIV) (PLWH) on highly active antiretroviral therapy (HAART). BACKGROUND: PLWH have a higher prevalence of cardiovascular disease and heart failure (HF) compared with the noninfected population. The pathophysiological drivers of myocardial dysfunction and worse cardiovascular outcome in HIV remain poorly understood. METHODS: This prospective observational longitudinal study included consecutive PLWH on long-term HAART undergoing cardiac magnetic resonance (CMR) examination for assessment of myocardial volumes and function, T1 and T2 mapping, perfusion, and scar. Time-to-event analysis was performed from the index CMR examination to the first single event per patient. The primary endpoint was an adjudicated adverse cardiovascular event (cardiovascular mortality, nonfatal acute coronary syndrome, an appropriate device discharge, or a documented HF hospitalization). RESULTS: A total of 156 participants (62% male; age [median, interquartile range]: 50 years [42 to 57 years]) were included. During a median follow-up of 13 months (9 to 19 months), 24 events were observed (4 HF deaths, 1 sudden cardiac death, 2 nonfatal acute myocardial infarction, 1 appropriate device discharge, and 16 HF hospitalizations). Patients with events had higher native T1 (median [interquartile range]: 1,149 ms [1,115 to 1,163 ms] vs. 1,110 ms [1,075 to 1,138 ms]); native T2 (40 ms [38 to 41 ms] vs. 37 ms [36 to 39 ms]); left ventricular (LV) mass index (65 g/m2 [49 to 77 g/m2] vs. 57 g/m2 [49 to 64 g/m2]), and N-terminal pro-B-type natriuretic peptide (109 pg/l [25 to 337 pg/l] vs. 48 pg/l [23 to 82 pg/l]) (all p < 0.05). In multivariable analyses, native T1 was independently predictive of adverse events (chi-square test, 15.9; p < 0.001; native T1 [10 ms] hazard ratio [95% confidence interval]: 1.20 [1.08 to 1.33]; p = 0.001), followed by a model that also included LV mass (chi-square test, 17.1; p < 0.001). Traditional cardiovascular risk scores were not predictive of the adverse events. CONCLUSIONS: Our findings reveal important prognostic associations of diffuse myocardial fibrosis and LV remodeling in PLWH. These results may support development of personalized approaches to screening and early intervention to reduce the burden of HF in PLWH (International T1 Multicenter Outcome Study; NCT03749343).


Subject(s)
HIV Infections , Female , Fibrosis , HIV Infections/drug therapy , Humans , Inflammation , Longitudinal Studies , Magnetic Resonance Spectroscopy , Male , Middle Aged , Predictive Value of Tests , Stroke Volume
5.
Br J Radiol ; 94(1122): 20210069, 2021 Jun 01.
Article in English | MEDLINE | ID: mdl-33914613

ABSTRACT

OBJECTIVES: To compare radiation dose and image quality of single-energy (SECT) and dual-energy (DECT) head and neck CT examinations performed with second- and third-generation dual-source CT (DSCT) in matched patient cohorts. METHODS: 200 patients (mean age 55.1 ± 16.9 years) who underwent venous phase head and neck CT with a vendor-preset protocol were retrospectively divided into four equal groups (n = 50) matched by gender and BMI: second (Group A, SECT, 100-kV; Group B, DECT, 80/Sn140-kV), and third-generation DSCT (Group C, SECT, 100-kV; Group D, DECT, 90/Sn150-kV). Assessment of radiation dose was performed for an average scan length of 27 cm. Contrast-to-noise ratio measurements and dose-independent figure-of-merit calculations of the submandibular gland, thyroid, internal jugular vein, and common carotid artery were analyzed quantitatively. Qualitative image parameters were evaluated regarding overall image quality, artifacts and reader confidence using 5-point Likert scales. RESULTS: Effective radiation dose (ED) was not significantly different between SECT and DECT acquisition for each scanner generation (p = 0.10). Significantly lower effective radiation dose (p < 0.01) values were observed for third-generation DSCT groups C (1.1 ± 0.2 mSv) and D (1.0 ± 0.3 mSv) compared to second-generation DSCT groups A (1.8 ± 0.1 mSv) and B (1.6 ± 0.2 mSv). Figure-of-merit/contrast-to-noise ratio analysis revealed superior results for third-generation DECT Group D compared to all other groups. Qualitative image parameters showed non-significant differences between all groups (p > 0.06). CONCLUSION: Contrast-enhanced head and neck DECT can be performed with second- and third-generation DSCT systems without radiation penalty or impaired image quality compared with SECT, while third-generation DSCT is the most dose efficient acquisition method. ADVANCES IN KNOWLEDGE: Differences in radiation dose between SECT and DECT of the dose-vulnerable head and neck region using DSCT systems have not been evaluated so far. Therefore, this study directly compares radiation dose and image quality of standard SECT and DECT protocols of second- and third-generation DSCT platforms.


Subject(s)
Head and Neck Neoplasms/diagnostic imaging , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Radiation Dosage , Retrospective Studies
6.
Acad Radiol ; 28(6): 769-777, 2021 06.
Article in English | MEDLINE | ID: mdl-32446765

ABSTRACT

RATIONALE AND OBJECTIVES: To evaluate the impact of noise-optimized virtual monoenergetic imaging (VMI) on lesion demarcation and measuring accuracy of hypoattenuating liver metastases in patients with fatty liver disease compared to standard reconstructions. MATERIALS AND METHODS: Twenty-eight patients (mean age 62.2 ± 7.7 years) with fatty liver disease and hypoattenuating liver metastases who underwent unenhanced and contrast-enhanced portal-venous dual-energy CT (DECT) were enrolled. Standard linearly blended and VMI series were reconstructed in 10-keV intervals. Lesion-to-parenchyma contrast-to-noise ratio (CNR) was calculated and the best VMI series was further investigated in a subjective evaluation of overall image quality and lesion demarcation. Size measurements were performed independently by measuring all hypodense lesions (n = 58) twice in a predefined sequence. Inter- and intra-rater agreement was assessed using intra-class correlation coefficient (ICC) statistics. RESULTS: The calculated CNR was greatest at 40-keV VMI (4.3 ± 2.6), significantly higher compared to standard reconstructions (2.9 ± 1.9; p < 0.001). Subjective ratings for overall image quality showed no significant difference between the 2 reconstruction techniques (both medians 4; p = 0.147), while lesion margin demarcation was found to be superior for 40-keV VMI (median 5; p ≤ 0.001). Inter- (ICC, 0.98 for 40-keV VMI; ICC, 0.93 for standard reconstruction) and intra-rater (ICC, 0.99 for 40-keV VMI; ICC, 0.94 for standard image series) analysis showed an excellent agreement for lesion measurements in both reconstruction techniques. CONCLUSION: Noise-optimized VMI reconstructions significantly improve contrast and lesion demarcation of hypoattenuating liver metastases in patients with the fatty liver disease compared to standard reconstruction.


Subject(s)
Liver Neoplasms , Radiography, Dual-Energy Scanned Projection , Aged , Humans , Liver Neoplasms/diagnostic imaging , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Signal-To-Noise Ratio , Tomography, X-Ray Computed
7.
Eur Radiol ; 31(6): 4071-4078, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33277670

ABSTRACT

OBJECTIVES: To evaluate the performance of radiomic features extracted from high-resolution computed tomography (HRCT) for the differentiation between cholesteatoma and middle ear inflammation (MEI), and to investigate the impact of post-reconstruction harmonization and data resampling. METHODS: One hundred patients were included in this retrospective dual-center study: 48 with histology-proven cholesteatoma (center A: 23; center B: 25) and 52 with MEI (A: 27; B: 25). Radiomic features (co-occurrence and run-length matrix, absolute gradient, autoregressive model, Haar wavelet transform) were extracted from manually defined 2D-ROIs. The ten best features for lesion differentiation were selected using probability of error and average correlation coefficients. A multi-layer perceptron feed-forward artificial neural network (MLP-ANN) was used for radiomics-based classification, with histopathology serving as the reference standard (70% of cases for training, 30% for validation). The analysis was performed five times each on (a) unmodified data and on data that were (b) resampled to the same matrix size, and (c) corrected for acquisition protocol differences using ComBat harmonization. RESULTS: Using unmodified data, the MLP-ANN classification yielded an overall median area under the receiver operating characteristic curve (AUC) of 0.78 (0.72-0.84). Using original data from center A and resampled data from center B, an overall median AUC of 0.88 (0.82-0.99) was yielded, while using ComBat harmonized data, an overall median AUC of 0.89 (0.79-0.92) was revealed. CONCLUSION: Radiomic features extracted from HRCT differentiate between cholesteatoma and MEI. When using multi-centric data obtained with differences in CT acquisition parameters, data resampling and ComBat post-reconstruction harmonization clearly improve radiomics-based lesion classification. KEY POINTS: • Unenhanced high-resolution CT coupled with radiomics analysis may be useful for the differentiation between cholesteatoma and middle ear inflammation. • Pooling of data extracted from inhomogeneous CT datasets does not appear meaningful without further post-processing. • When using multi-centric CT data obtained with differences in acquisition parameters, post-reconstruction harmonization and data resampling clearly improve radiomics-based soft-tissue differentiation.


Subject(s)
Cholesteatoma , Otitis Media , Humans , ROC Curve , Retrospective Studies , Tomography, X-Ray Computed
8.
J Cardiovasc Med (Hagerstown) ; 21(12): 980-985, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33156590

ABSTRACT

AIM: To assess the prevalence and prognostic significance of NI-LGE in patients undergoing stress-CMR. METHODS: Stress-CMR with either dipyridamole or adenosine was performed in 283 patients (228 men, 81%) including perfusion imaging, wall motion evaluation and LGE. Follow-up was completed in all enrolled patients (median time: 1850 days; interquartile range: 1225-2705 days). Composite endpoint included cardiac death, ventricular tachycardia, myocardial infarction, stroke, hospitalization for cardiac cause and coronary revascularization performed beyond 90 days from stress-CMR scans. RESULTS: One hundred and twelve patients (40%) had negative LGE (no-LGE), 140 patients (49%) I-LGE and 31 patients (11%) NI-LGE. Twenty-five events occurred in the no-LGE group, 68 in I-LGE and 11 in the NI-LGE group. On survival curves, patients with NI-LGE had worse prognosis than patients with no-LGE regardless of the presence of inducible perfusion defects. No significant prognostic differences were found between I-LGE and NI-LGE. CONCLUSION: NI-LGE can be detected in 11% of patients during stress-CMR providing a diagnosis of nonischemic cardiac disease. Patients with NI-LGE have worse prognosis than those with no-LGE.


Subject(s)
Adenosine/administration & dosage , Contrast Media , Dipyridamole/administration & dosage , Heart Diseases/diagnostic imaging , Magnetic Resonance Imaging , Myocardium/pathology , Perfusion Imaging , Vasodilator Agents/administration & dosage , Aged , Female , Fibrosis , Heart Diseases/mortality , Heart Diseases/pathology , Heart Diseases/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Prevalence , Prognosis , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors
9.
Eur J Radiol ; 132: 109276, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32998080

ABSTRACT

PURPOSE: To analyze the impact of tube potential and iodine concentration on the visibility of calcified plaques in coronary computed tomography angiography (cCTA). METHODS & MATERIALS: 164 consecutive patients (65.9 % men and a mean age of 57.1 ±â€¯11.3 years) with suspected coronary artery disease underwent calcium scoring (CaSc) scan followed by cCTA with topogram-based automated tube voltage selection (70 kV, 80 kV, 90 kV, 100 kV or 120 kV). In 127 Patients (HC), we injected 50 mL of contrast material (CM) with a concentration of 400 mg iodine per ml and in 37 patients (LC) 50 mL iodine concentration of 280 mg/mL. Sensitivity of cCTA for detecting calcified plaques was calculated with CaSc serving as gold standard. Density of CM enhanced coronary vessels and calcified plaques were quantified by region-of-interest (ROI) measurements in unenhanced and cCTA image series. RESULTS: Overall sensitivity of cCTA to detect calcified plaques was significantly higher using LC compared to HC (79 % vs. 73 %; p = 0.0035). The impact of LC was impressive at 70 kV with an improved sensitivity of 70 % vs. 57.1 % in HC (p = 0.0082). Furthermore, density values of HC enhanced coronary vessels exceeded those of calcified plaques, especially at low kV levels. In LC, except for the 70 kV setting, higher density values were shown for calculi than enhanced vessels. CONCLUSION: Low kV cCTA in routine using highly concentrated CM leads to reduced calcified plaque perceptibility and hence potentially underestimation of stenosis. Thus, low kV cCTA using CM with lower iodine concentration is necessary. In addition, a dose reduction up to 77.7 % can also be benefited.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Aged , Computed Tomography Angiography , Contrast Media , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Female , Humans , Male , Middle Aged , Tomography, X-Ray Computed
10.
Eur J Radiol ; 130: 109166, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32693314

ABSTRACT

PURPOSE: Dedicated post-processing of dual-energy computed tomography angiography (DE-CTA) datasets has been shown to allow for increased vascular contrast. The goal of our study was to define optimal window settings for displaying virtual monoenergetic images (VMI) reconstructed from dual-energy carotid and cerebrovascular DE-CTA. METHODS: Fifty-seven patients who underwent clinically-indicated carotid and cerebrovascular third-generation dual-source DE-CTA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimized VMI (M40+) reconstructions were analyzed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with aortic arch attenuation to calculate optimized values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures analysis of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40 + . RESULTS: B-W/L and O-W/L for M70 were 580/210 and 560/200, and for M40+ were 1630/570 and 1560/550, respectively, higher than standard DE-CTA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding overall IQ (all p < 0.001). CONCLUSION: Application of O-W/L settings is mandatory to optimize subjective IQ of VMI reconstructions of DE-CTA.


Subject(s)
Carotid Artery Diseases/diagnostic imaging , Computed Tomography Angiography/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Aged , Carotid Arteries/diagnostic imaging , Cerebrovascular Disorders/diagnostic imaging , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Signal-To-Noise Ratio
11.
Acad Radiol ; 27(7): e168-e175, 2020 07.
Article in English | MEDLINE | ID: mdl-31727567

ABSTRACT

RATIONALE AND OBJECTIVES: To compare dual-energy CT virtual monoenergetic images (VMI) and standard reconstructions for reliability of quantitative size measurements and diagnostic accuracy for the detection of colorectal liver metastases (CRLM). MATERIALS AND METHODS: We retrospectively included 98 patients (mean age, 61.1±11.5 years) with colorectal cancer, of whom 49 subjects had CRLM. All patients underwent a portal-venous phase dual-energy CT examination. Standard linearly-blended reformats and 40-keV VMI were reconstructed. For both reconstruction techniques, two blinded readers performed measurements of CRLM twice in a preset sequence. Three additional radiologists independently assessed all liver lesions in terms of dignity (benign vs. malignant). Sensitivity, specificity and diagnostic accuracy were calculated on a per-patient basis using MRI as reference standard. Readers scored the suitability for metric measurements and their diagnostic confidence using 5-point Likert scales. Inter-rater agreement was evaluated using intraclass correlation coefficient (ICC). RESULTS: Inter-rater agreement for lesion size measurements was higher for 40-keV VMI (ICC, 0.88) compared to standard linearly-blended series (ICC, 0.80). Sensitivity and diagnostic accuracy for the detection of CRLM were significantly higher for VMI at 40-keV compared to standard reconstructions (90.6% vs. 80.6%, and 89.1% vs. 81.3%; p < 0.001). Reader scores indicated that 40-keV VMI were more suitable for metric lesion measurements and provided greater diagnostic confidence compared to standard reformats (median, 5 vs. 3, and 5 vs. 4; both p < 0.001). CONCLUSION: Low-keV VMI reconstructions improve reliability of quantitative size measurements and diagnostic accuracy for the assessment of CRLM compared to standard linearly-blended images.


Subject(s)
Colorectal Neoplasms , Liver Neoplasms , Radiography, Dual-Energy Scanned Projection , Aged , Colorectal Neoplasms/diagnostic imaging , Humans , Liver Neoplasms/diagnostic imaging , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Reproducibility of Results , Retrospective Studies , Signal-To-Noise Ratio , Tomography, X-Ray Computed
12.
Eur J Radiol ; 122: 108666, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31786506

ABSTRACT

PURPOSE: To define optimal kiloelectron volt (keV) settings for virtual monoenergetic imaging (VMI) reconstruction at dual-energy coronary computed tomography angiography (DE-CCTA). METHOD: Fifty-one DE-CCTA data sets (33 men; mean age, 63.9 ±â€¯13.2 years) were reconstructed as standard linearly-blended images (F_0.6; 60% of 90 kVp, 40% of 150 kVpSn), and with traditional (VMI) and noise-optimised (VMI+) algorithms from 40 to 100 keV in 10-keV intervals. Objective image quality was assessed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. Three observers subjectively evaluated vascular contrast, image sharpness, noise and delineation of coronary plaques. RESULTS: Median values for objective image analysis were highest in VMI + series at 40 keV (SNR, 44.5; CNR: 33.5), significantly superior (allp < 0.001) to the best VMI series at 70 keV (SNR, 28.1; CNR, 18.4) and standard F_0.6 images (SNR, 23.2; CNR, 15.6). Overall subjective metrics achieved higher scores at 40-keV VMI+ series in comparison to 70-keV VMI series and F_0.6 images (all p < 0.001), with optimal vascular contrast (5; ICC, 0.90), good image sharpness (4; 0.88), low noise (4; 0.82), and optimal plaque delineation (5; 0.89). CONCLUSIONS: DE-CCTA image reconstruction with 40-keV VMI + allows for significant improvement of both objective and subjective image quality.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Adult , Aged , Algorithms , Computed Tomography Angiography , Contrast Media , Female , Humans , Image Processing, Computer-Assisted/methods , Iopamidol/analogs & derivatives , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Retrospective Studies , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods
13.
Eur Radiol ; 29(5): 2553-2559, 2019 May.
Article in English | MEDLINE | ID: mdl-30547199

ABSTRACT

OBJECTIVES: Increasing awareness of potential side effects from gadolinium-based contrast agents has underlined the need for contrast-free magnetic resonance imaging (MRI). Numerous recent articles evaluated the risk of potential brain deposits, with the result that research is putting the focus more on alternative unenhanced imaging techniques. The aim of this study was to determine the need for contrast media for chest MRI in primary staging and follow-up care of lymphoma. METHODS: This monocentric, retrospective study encompassed patients under 25 years of age who had undergone histopathological examination of thoracic lymph nodes and at least one chest MRI examination with unenhanced and contrast-enhanced sequences. Seven different thoracic lymph node stations including mediastinal, hilar, periclavicular, and axillary regions were evaluated by two readers regarding lesion diameter, number, shape, necrosis, and infiltration of surrounding structures. Findings were categorized into suspicious (> 1 cm; round; necrosis; infiltration) or non-suspicious. RESULTS: Fifty-one patients (mean age, 16.0 ± 3.7 yrs) with thoracic Hodgkin (70.6%) and non-Hodgkin lymphoma (25.5%) and lymphadenopathy (3.9%) were retrospectively included. Most lymph nodes categorized as suspicious were located in the mediastinal station (86.4%). High agreement (κ = 0.81) between unenhanced and contrast-enhanced sequences was found for both suspicious and non-suspicious lymph nodes. Significant (p < 0.001), but small difference (1 mm) was observed only in sizing mediastinal lymph nodes (all other p > 0.05). No significant difference (smallest p = 0.08) was shown for the use of five different types of contrast media. CONCLUSION: MRI in young patients with thoracic lymphoma can safely be done without the use of contrast agent. KEY POINT: • Thoracic magnetic resonance imaging in young lymphoma patients can safely be done without gadolinium-based contrast agents.


Subject(s)
Lymphoma/diagnosis , Magnetic Resonance Imaging/methods , Organometallic Compounds/pharmacology , Thoracic Neoplasms/diagnosis , Adolescent , Adult , Child , Child, Preschool , Contrast Media/pharmacology , Female , Humans , Male , Retrospective Studies , Young Adult
14.
Eur J Radiol ; 108: 140-146, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30396647

ABSTRACT

OBJECTIVES: Non-contrast-enhanced quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) and invasive carbon dioxide (CO2) angiography are suggested as nephroprotective methods for accurate staging of peripheral arterial disease (PAD) in patients with chronic renal insufficiency (CRI). The aim of our study was to compare the image quality of both examinations. METHODS: 16 consecutive PAD patients with highly impaired renal function (estimated glomerular filtration rate (eGFR) < 30 ml/min/1.73 m²) who underwent 3 T MRA with QISS and catheter angiography with CO2 within 90 days were retrospectively included. Subjective image quality was determined using a five-point Likert scale (1, non-diagnostic; 5, excellent) and presence of significant (≥50%) stenoses of pelvic and lower extremity arteries (21-segment-model) was evaluated per-region and per-segment, respectively, in random order by four independent readers with different levels of experience. CO2 angiography of an experienced interventional radiologist was considered the standard reference method. RESULTS: 167 segments were available for direct comparison with a prevalence of ≥50% stenoses of 28.1%. QISS-MRA yield was: sensitivity 91.5%, specificity 94.2%, positive predictive value 86.0% and negative predictive value 96.6%, with an intraclass correlation coeffcient (ICC) of 0.88. Median values of qualitative imaging parameters for QISS-MRA were as follows: arterial signal intensity: 4 (pelvis), 5 (thigh), 5 (calf); venous overlay: 4, 5, 5; susceptibility artifacts: 5, 5, 5; motion artifacts: 4, 5, 5; ECG-related artifacts: 5, 5, 5. ICC-values for image quality were 0.74, 0.73, 0.93, 0.69 and 0.79, respectively. Arterial opacification at CO2 angiography was rated 3, 4, 3, with an ICC of 0.63. CONCLUSIONS: Image quality of non-invasive unenhanced MR angiography with QISS was preferred over invasive CO2 angiography, whilst taking into account that it offers high diagnostic performance for the detection and ruling out of PAD.


Subject(s)
Angiography/methods , Peripheral Arterial Disease/pathology , Renal Insufficiency, Chronic/pathology , Adult , Aged , Angiography, Digital Subtraction/methods , Arteries/pathology , Carbon Dioxide/metabolism , Constriction, Pathologic/pathology , Female , Humans , Lower Extremity/blood supply , Magnetic Resonance Angiography/methods , Male , Middle Aged , Prospective Studies , Retrospective Studies , Sensitivity and Specificity
15.
Eur J Radiol ; 106: 184-191, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30150043

ABSTRACT

PURPOSE: To assess the value of the noise-optimized virtual monoenergetic imaging (VMI+) technique on quantitative and qualitative image parameters in patients with hypoattenuating liver metastases from colorectal cancer (CRC) at abdominal dual-energy CT (DECT). MATERIALS AND METHODS: Fifty-three consecutive patients (mean age, 70.3 ± 11.4 years; range, 44-86 years) with histologically proven, hypoattenuating liver metastases from CRC were retrospectively included in this IRB-approved study. DECT datasets were reconstructed as standard linearly-blended M_0.6 image series, traditional virtual monoenergetic images (VMI), and noise-optimized VMI+ series. VMI and VMI+ reconstructions were obtained at energy levels ranging from 40 to 100-keV with 10-keV increments. Signal attenuation of liver parenchyma and liver metastases was measured to calculate signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Each image series was subjectively rated by three blinded radiologists with regard to image quality, lesion delineation, and image noise using a five-point Likert scale. RESULTS: Quantitative image quality parameters peaked at 40-keV VMI+ (SNR, 8.1 ± 3.4; CNR, 6.5 ± 2.6) with statistically significant differences in comparison with standard reconstructions and all traditional VMI series (P ≤ 0.001). Qualitative image analysis revealed best rating scores for 60-keV VMI+ series (median, 5) with significant differences compared to linearly-blended M_0.6 and all traditional VMI series (P ≤ 0.001). Lesion delineation showed significantly superior ratings for 40-keV VMI+ series compared to all other reconstructions (median, 5) (P ≤ 0.001). CONCLUSION: Low-keV VMI+ reconstructions demonstrate significantly increased quantitative and qualitative image quality parameters in patients with hypoattenuating liver metastases from CRC in comparison with standard reconstructions and traditional VMI series at abdominal DECT. Best lesion delineation can be achieved at 40-keV VMI+.


Subject(s)
Colorectal Neoplasms/pathology , Image Processing, Computer-Assisted/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Liver/diagnostic imaging , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted/methods , Retrospective Studies , Signal-To-Noise Ratio
16.
Eur Radiol ; 28(7): 2756-2762, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29417250

ABSTRACT

OBJECTIVES: We investigated the potential reduction of patient exposure during invasive coronary angiography (ICA) if the procedure had only been directed to the vessel with at least one ≥ 50% stenosis as described in the CT report. METHODS: Dose reports of 61 patients referred to ICA because of at least one ≥ 50% stenosis on coronary CT angiography (CCTA) were included. Dose-area product (DAP) was documented separately for left (LCA) and right coronary arteries (RCA) by summing up the single DAP for each angiographic projection. The study population was subdivided as follows: coronary intervention of LCA (group 1) or RCA (group 2) only, or of both vessels (group 3), or further bypass grafting (group 4), or no further intervention (group 5). RESULTS: 57.4% of the study population could have benefitted from reduced exposure if catheterization had been directly guided to the vessel of interest as described on CCTA. Mean relative DAP reductions were as follows: group 1 (n = 18), 11.2%; group 2 (n = 2), 40.3%; group 3 (n = 10), 0%; group 4 (n = 3), 0%; group 5 (n = 28), 28.8%. CONCLUSIONS: Directing ICA to the vessel with stenosis as described on CCTA would reduce intraprocedural patient exposure substantially, especially for patients with single-vessel stenosis. KEY POINTS: • Patients with CAD can benefit from decreased radiation exposure during coronary angiography. • ICA should be directed solely to significant stenoses as described on CCTA. • Severely calcified plaques remain a limitation of CCTA leading to unnecessary ICA referrals.


Subject(s)
Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Aged , Coronary Artery Disease/pathology , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/pathology , Coronary Stenosis/therapy , Coronary Vessels/diagnostic imaging , Female , Humans , Male , Middle Aged , Radiation Dosage , Radiation Exposure/prevention & control , Radiography, Interventional/methods , Retrospective Studies , Severity of Illness Index , Thorax
17.
Eur J Radiol ; 99: 111-117, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29362140

ABSTRACT

PURPOSE: To investigate the impact of traditional (VMI) and noise-optimized virtual monoenergetic imaging (VMI+) algorithms on quantitative and qualitative image quality, and the assessment of stenosis in carotid and intracranial dual-energy CTA (DE-CTA). MATERIALS AND METHODS: DE-CTA studies of 40 patients performed on a third-generation 192-slice dual-source CT scanner were included in this retrospective study. 120-kVp image-equivalent linearly-blended, VMI and VMI+ series were reconstructed. Quantitative analysis included evaluation of contrast-to-noise ratios (CNR) of the aorta, common carotid artery, internal carotid artery, middle cerebral artery, and basilar artery. VMI and VMI+ with highest CNR, and linearly-blended series were rated qualitatively. Three radiologists assessed artefacts and suitability for evaluation at shoulder height, carotid bifurcation, siphon, and intracranial using 5-point Likert scales. Detection and grading of stenosis were performed at carotid bifurcation and siphon. RESULTS: Highest CNR values were observed for 40-keV VMI+ compared to 65-keV VMI and linearly-blended images (P < 0.001). Artefacts were low in all qualitatively assessed series with excellent suitability for supraaortic artery evaluation at shoulder and bifurcation height. Suitability was significantly higher in VMI+ and VMI compared to linearly-blended images for intracranial and ICA assessment (P < 0.002). VMI and VMI+ showed excellent accordance for detection and grading of stenosis at carotid bifurcation and siphon with no differences in diagnostic performance. CONCLUSION: 40-keV VMI+ showed improved quantitative image quality compared to 65-keV VMI and linearly-blended series in supraaortic DE-CTA. VMI and VMI+ provided increased suitability for carotid and intracranial artery evaluation with excellent assessment of stenosis, but did not translate into increased diagnostic performance.


Subject(s)
Carotid Stenosis/diagnostic imaging , Computed Tomography Angiography/methods , Algorithms , Artifacts , Carotid Artery, Common/diagnostic imaging , Carotid Artery, Internal/diagnostic imaging , Feasibility Studies , Female , Humans , Infarction, Middle Cerebral Artery/diagnostic imaging , Male , Middle Aged , Noise , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Retrospective Studies , Signal-To-Noise Ratio , Vertebrobasilar Insufficiency/diagnostic imaging
18.
Eur J Cardiothorac Surg ; 53(4): 784-792, 2018 04 01.
Article in English | MEDLINE | ID: mdl-29186380

ABSTRACT

OBJECTIVES: Allogeneic frozen cryopreserved heart valves (allografts or homografts) are commonly used in clinical practice. A major obstacle for their application is the limited availability in particular for paediatrics. Allogeneic large animal studies revealed that alternative ice-free cryopreservation (IFC) results in better matrix preservation and reduced immunogenicity. The objective of this study was to evaluate xenogeneic (porcine) compared with allogeneic (ovine) IFC heart valves in a large animal study. METHODS: IFC xenografts and allografts were transplanted in 12 juvenile merino sheep for 1-12 weeks. Immunohistochemistry, ex vivo computed tomography scans and transforming growth factor-ß release profiles were analysed to evaluate postimplantation immunopathology. In addition, near-infrared multiphoton imaging and Raman spectroscopy were employed to evaluate matrix integrity of the leaflets. RESULTS: Acellular leaflets were observed in both groups 1 week after implantation. Allogeneic leaflets remained acellular throughout the entire study. In contrast, xenogeneic valves were infiltrated with abundant T-cells and severely thickened over time. No collagen or elastin changes could be detected in either group using multiphoton imaging. Raman spectroscopy with principal component analysis focusing on matrix-specific peaks confirmed no significant differences for explanted allografts. However, xenografts demonstrated clear matrix changes, enabling detection of distinct inflammatory-driven changes but without variations in the level of transforming growth factor-ß. CONCLUSIONS: Despite short-term success, mid-term failure of xenogeneic IFC grafts due to a T-cell-mediated extracellular matrix-triggered immune response was shown.


Subject(s)
Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Immunity, Cellular , T-Lymphocytes/pathology , Animals , Heart Valves/diagnostic imaging , Heart Valves/pathology , Heart Valves/surgery , Sheep , Spectrum Analysis, Raman , Swine , Tomography, X-Ray Computed , Transforming Growth Factor beta/metabolism
19.
Eur Radiol ; 28(4): 1393-1401, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29018926

ABSTRACT

OBJECTIVES: To define optimal window settings for displaying virtual monoenergetic images (VMI) of dual-energy CT pulmonary angiography (DE-CTPA). METHODS: Forty-five patients who underwent clinically-indicated third-generation dual-source DE-CTPA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimised VMI (M40+) reconstructions were analysed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with pulmonary artery attenuation to calculate separate optimised values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40+. RESULTS: B-W/L and O-W/L for M70 were 460/140 and 450/140, and were 1100/380 and 1070/380 for M40+, respectively, differing from standard DE-CTPA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding vascular contrast, embolism demarcation, and overall IQ (all p<0.001). CONCLUSIONS: Application of O-W/L settings is beneficial to optimise subjective IQ of VMI reconstructions of DE-CTPA. A width slightly less than two times the pulmonary trunk attenuation and a level approximately of overall pulmonary vessel attenuation are recommended. KEY POINTS: • Application of standard window settings for VMI results in inferior image perception. • No significant differences between B-W/L and O-W/L for M70/M40+ were observed. • O-W/L for M70 were 450/140 and were 1070/380 for M40+. • Improved subjective IQ characteristics were observed for VMI displayed with O-W/L.


Subject(s)
Computed Tomography Angiography/methods , Image Processing, Computer-Assisted/methods , Pulmonary Embolism/diagnostic imaging , Female , Humans , Male , Middle Aged , Pulmonary Artery/diagnostic imaging , Radiography, Dual-Energy Scanned Projection/methods , Reproducibility of Results , Retrospective Studies , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...