Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
J Invasive Cardiol ; 34(12): E879-E882, 2022 12.
Article in English | MEDLINE | ID: mdl-36328517

ABSTRACT

Application of the hybrid algorithm for the treatment of coronary chronic total occlusions requires the operator to readily deploy complex techniques and advanced technologies to achieve successful revascularization. Patient-specific factors and limitations in torquability and material strength of low-profile equipment such as microcatheters can result in procedural complications due to device fracture. Using a mini-series of 2 cases to demonstrate the successful application of antegrade dissection re-entry techniques to overcome such challenges, we highlight procedural complexities and risk, and review prior approaches and literature.


Subject(s)
Coronary Occlusion , Percutaneous Coronary Intervention , Humans , Coronary Occlusion/diagnosis , Coronary Occlusion/surgery , Percutaneous Coronary Intervention/adverse effects
2.
Heart Lung Circ ; 31(12): 1649-1657, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36038469

ABSTRACT

OBJECTIVE: This study sought to investigate the characteristics, morbidity (including the rate of infective endocarditis and valve replacement) and mortality of individuals undergoing percutaneous pulmonary valve implantation in Australia and New Zealand since the procedure has been performed. BACKGROUND: The outcomes of percutaneous pulmonary valve implantation in Australia and New Zealand have not been evaluated. Recent international data, including patients from New Zealand, suggests the rate of infective endocarditis is not insignificant. METHODS: A retrospective multi-site cohort study was undertaken via medical record review at the centres where percutaneous pulmonary valve implantation has been performed. All procedures performed from 2009-March 2018 were included. Individuals were identified from local institution databases. Data was collected and analysed including demographics, details at the time of intervention, haemodynamic outcome, post procedure morbidity and mortality. Multi-site ethics approval was obtained. RESULTS: One hundred and seventy-nine (179) patients attended the cardiac catheter laboratory for planned percutaneous pulmonary valve implantation. Of these patients, 172 underwent successful implantation. Tetralogy of Fallot and pulmonary atresia were the most common diagnoses. The median age at procedure was 19 years (range 3-60 yrs). There was a significant improvement in the acute haemodynamics in patients undergoing percutaneous pulmonary valve implantation for stenosis. Seven (7) patients (3.9%) experienced a major procedural/early post procedure complication (death, conversion to open procedure, cardiac arrest), including two deaths. The annualised rates of infective endocarditis and valve replacement were 4.6% and 3.8% respectively. There was one death related to infective endocarditis in follow-up. CONCLUSIONS: Percutaneous pulmonary valve replacement is a relatively safe method of rehabilitating the right ventricular outflow tract.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Child, Preschool , Child , Adolescent , Young Adult , Adult , Middle Aged , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis/adverse effects , New Zealand/epidemiology , Retrospective Studies , Cohort Studies , Treatment Outcome , Endocarditis, Bacterial/complications , Pulmonary Valve Insufficiency/epidemiology , Pulmonary Valve Insufficiency/surgery , Endocarditis/epidemiology , Endocarditis/surgery , Cardiac Catheterization/methods
3.
Catheter Cardiovasc Interv ; 100(2): 227-232, 2022 08.
Article in English | MEDLINE | ID: mdl-35686532

ABSTRACT

OBJECTIVES: We describe the first experience using calcification of anatomical landmarks to obviate the need for transcatheter aortic valve implantation (TAVI) alignment aortography and secondary TAVI access. BACKGROUND: TAVI alignment conventionally involves secondary femoral access for contrast aortography using a second catheter. Secondary femoral access accounts for up to 25% of all vascular complications. Heavily calcified aortic leaflets are often visible fluoroscopically and can act as markers for TAVI alignment. METHODS: We considered 100 consecutive patients for transfemoral TAVI. The first group was considered for a conventional dual access technique and the subsequent group was considered for a single access technique. Relevant baseline, and procedural and outcome measures were recorded. RESULTS: Baseline characteristics were comparable between groups. Balloon-expandable transcatheter heart valves (THV) were used in all cases. THV implantation was successful in 100% of cases with no procedural or in-hospital mortality. Procedural time and contrast use were lower in the single access group. There were no Valve Academic Research Consortium (VARC)-2 major vascular complications with the single access technique. CONCLUSIONS: This is the first study describing the use of calcification of anatomical landmarks to obviate the need for secondary TAVI access. Notable observations included successful device implantation in all cases, no VARC-2 major vascular complications, comparable rates of paravalvular leak and permanent pacemaker requirement, shorter procedural times, and lower contrast use. Single access TAVI is a viable alternative technique to minimize vascular access, contrast use, and procedural duration in experienced centers and with selected patients, allowing successful device implantation and low complication rates while further streamlining TAVI workflow.


Subject(s)
Aortic Valve Stenosis , Calcinosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Femoral Artery/diagnostic imaging , Humans , Treatment Outcome
4.
Heart Lung Circ ; 31(3): 372-382, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34654649

ABSTRACT

AIMS: This study sought to investigate patient and operator radiation dose in patients undergoing percutaneous coronary intervention (PCI) and the impact of body mass index (BMI) on patient and operator dose. METHODS: In patients undergoing PCI, radiation dose parameters, baseline characteristics and procedural data were collected in a tertiary centre for 3.5 years. Operators wore real time dosimeters. Patients were grouped by BMI. Dose area product (DAP) and operator radiation dose were compared across patient BMI categories. Multivariable analysis was performed to investigate the impact of patient BMI and other procedural variables on patient and operator dose. RESULTS: 2,043 patients underwent 2,197 PCI procedures. Each five-unit increase in BMI increased patient dose (expressed as DAP) by an average 31% (95% CI: 29-33%) and operator dose by 27% (95% CI: 20-33%). Patient dose was 2.3 times higher and operator dose was 2.4 times higher in patients with a BMI>40 than for normal BMI patients. Multivariable analysis indicated that there were many procedural factors that were predictors for increasing operator dose and patient dose but that patient BMI was a major contributor for both operator dose and patient dose. CONCLUSION: Increasing BMI increases the DAP and operator dose for PCI procedures and BMI is demonstrated to be a major factor that contributes to both patient and operator radiation dose.


Subject(s)
Percutaneous Coronary Intervention , Radiation Exposure , Body Mass Index , Coronary Angiography/adverse effects , Humans , Percutaneous Coronary Intervention/methods , Radiation Dosage , Risk Factors
5.
JACC Case Rep ; 3(10): 1332-1335, 2021 Aug 18.
Article in English | MEDLINE | ID: mdl-34471889

ABSTRACT

We describe the case of a 73-year-old woman presenting with heart failure, a degenerating bioprosthetic mitral valve, and severely dilated left atrium, and highlight the role of multimodality imaging in planning transseptal transcatheter mitral valve-in-valve implantation. (Level of Difficulty: Advanced.).

6.
Open Heart ; 8(1)2021 06.
Article in English | MEDLINE | ID: mdl-34127530

ABSTRACT

AIMS: Durability of transcatheter aortic valve implantation (TAVI) is key to its expansion. We sought to identify incidence of valve thrombosis and predictors of valve thrombosis in our single centre with associated coagulation testing pre-TAVI and post-TAVI. METHODS AND RESULTS: This single-centre observational study comprised patients undergoing transfemoral TAVI discussed in the Heart Team meeting . Patients were followed up with echocardiography at 120 days to identify incidence of elevated transvalvular gradient and multivariable analysis was performed to identify factors associated with an increased odds of developing valve thrombosis. In addition, 11 patients underwent baseline, day 1 and day 120 post-TAVI coagulation testing. Between August 2017 and August 2019, 437 consecutive patients underwent transfemoral TAVI. Of these patients, 207/437 (47.4%) had 3-month follow-up echo data available and were analysed. Of these patients, 26/207 (12.6%) had elevated transvalvular gradients. These patients tended to be younger (80±14 vs 83±6 years; p=0.047) with a lower ejection fraction (49±13 vs 54%±11%; p=0.021), with a greater proportion of the population experiencing atrial fibrillation (14/21, 54% vs 68/181, 38%; p=0.067). Following multivariable analysis, there remained a trend towards higher eccentricity index associated with elevated gradients. Baseline (pre-TAVI) elevation of thrombin antithrombin levels (56±63; reference range 1.0-4.1 ng/L) and PF 1+2 (791±632; reference range 69-229 ng/mL) normalised at 120 days post-TAVI CONCLUSION: This study demonstrated that in the cohort of patients undergoing transfemoral TAVI in our centre: younger age, poor ejection fraction, atrial fibrillation and increased baseline eccentricity of the aortic valve annulus were present to a greater extent in patients exhibiting elevated transvalvular gradients at 3-month follow-up. Further work is required to delineate the extent of coagulation derangement and confirm predictors of thrombosis.


Subject(s)
Aortic Valve Stenosis/surgery , Blood Coagulation Disorders/blood , Blood Coagulation/physiology , Heart Diseases/blood , Heart Valve Prosthesis/adverse effects , Risk Assessment/methods , Thrombosis/blood , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/blood , Aortic Valve Stenosis/diagnosis , Biomarkers/blood , Blood Coagulation Disorders/complications , Blood Coagulation Disorders/epidemiology , Echocardiography , Female , Follow-Up Studies , Heart Diseases/epidemiology , Heart Diseases/etiology , Humans , Incidence , Male , Prospective Studies , Prosthesis Design , Risk Factors , Thrombosis/epidemiology , Thrombosis/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , United Kingdom/epidemiology
7.
J Clin Med ; 10(8)2021 Apr 20.
Article in English | MEDLINE | ID: mdl-33924077

ABSTRACT

Over the past decade, indications for transcatheter aortic valve implantation (TAVI) have progressed rapidly-procedural numbers now exceed those of surgical aortic valve replacement (SAVR) in many countries, and TAVI is now a realistic and attractive alternative to SAVR in low-risk patients. Neurocognitive outcomes after TAVI and SAVR remain an issue and sit firmly under the spotlight as TAVI moves into low-risk cohorts. Cognitive decline and stroke carry a significant burden and predict future functional decline, reduced mobility, poor quality of life and increased mortality. Early TAVI trials used varying neurocognitive definitions, and outcomes differed significantly as a result. Recent international consensus statements defining endpoints following TAVI and SAVR have standardised neurological outcomes and facilitate interpretation and comparison between trials. The latest TAVI and SAVR trials have demonstrated more consistent and favourable neurocognitive outcomes for TAVI patients, and cerebral embolic protection devices offer the prospect of further refinement and improvement.

8.
Br J Radiol ; 93(1112): 20200018, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32543896

ABSTRACT

OBJECTIVES: Radiation from cardiac angiography procedures is harmful to patients and the staff performing them. This study sought to investigate operator radiation dose for a range of procedures and different operators in order to investigate trends and optimise dose. METHODS: Real-time dosemeters (RTDs) were worn by operators for angiography procedures for 3 years. Dose-area product (DAP) and RTD were collected. RTD was normalised to DAP (RTD/DAP) to compare radiation dose and radiation protection measures. Comparisons were made across procedure categories and individual operators. RESULTS: In 7626 procedures, median and 75th percentile levels were established for operator dose for 8 procedure categories. There was a significant difference in all operator dose measures and DAP across procedure categories (p<0.001). DAP, RTD, and RTD/DAP were significantly different across 22 individual operators (p<0.001). CONCLUSION: DAP was significantly different across procedure categories and a higher RTD was seen with higher DAP. RTD/DAP can demonstrate radiation protection effectiveness and identified differences between procedures and individual operators with this measure. Procedures and individuals were identified where further optimisation of radiation protection measures may be beneficial. A reference level for operator dose can be created and audited against on a regular basis. ADVANCES IN KNOWLEDGE: This study demonstrates that operator dose can be easily and routinely measured on a case by case basis to investigate dose trends for different procedures. Normalising the operator dose to DAP demonstrates radiation protection effectiveness for the individual operator which can then be optimised as part of an ongoing audit program.


Subject(s)
Cardiac Catheterization/adverse effects , Coronary Angiography/adverse effects , Occupational Exposure/statistics & numerical data , Radiation Exposure/statistics & numerical data , Adult , Aged , Aged, 80 and over , Female , Health Personnel , Humans , Male , Middle Aged , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control , Radiation Dosimeters , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Radiation Protection/methods , Radiography, Interventional/methods , Retrospective Studies
10.
Eur Heart J Case Rep ; 3(2)2019 Jun 01.
Article in English | MEDLINE | ID: mdl-31449617

ABSTRACT

BACKGROUND: Three-dimensional (3D) printing of cardiac fistulae allows for immediate understanding of their complex courses and anatomical relations. Models can be used to improve patient understanding, enhance the consenting process, facilitate communication between multidisciplinary staff at heart team meetings, and help plan surgical or percutaneous interventions. CASE SUMMARY: We report four cases where 3D printed models were used as an adjunct with traditional measures in treating patients with complex cardiac fistulae. DISCUSSION: In our cases, overall patient understanding was improved, staff at heart team meetings were more aware of anatomical anomalies and perioperatively planning saw adjustments made that may have ultimately benefited patient outcome. Our cases highlight the additional benefit that 3D printed models can play when treating patients with complex cardiac fistulae.

11.
Catheter Cardiovasc Interv ; 92(7): E478-E480, 2018 12 01.
Article in English | MEDLINE | ID: mdl-30260091

ABSTRACT

We present the case of a 21-year-old female with a complex right coronary sinus of valsalva to right atrial fistulae. 3D printing of the fistulae and surrounding anatomy was beneficial in assessment of the anatomy and perioperative planning. Successful percutaneous closure was achieved.


Subject(s)
Aortic Rupture/therapy , Cardiac Catheterization/methods , Heart Atria , Patient-Specific Modeling , Printing, Three-Dimensional , Sinus of Valsalva , Vascular Fistula/therapy , Aortic Rupture/diagnostic imaging , Female , Heart Atria/diagnostic imaging , Humans , Models, Anatomic , Models, Cardiovascular , Multimodal Imaging , Sinus of Valsalva/diagnostic imaging , Treatment Outcome , Vascular Fistula/diagnostic imaging , Young Adult
12.
Intern Med J ; 48(4): 382-390, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29623986

ABSTRACT

Mitral regurgitation (MR) is a valvular heart disease associated with significant morbidity and mortality. Transcatheter mitral valve intervention (TMVI) repairs or replaces the mitral valve through small arterial and venous entry sites and so avoids risks associated with open heart surgery. Transcatheter devices targeting components of the mitral apparatus are being developed to repair or replace it. Numerous challenges remain including developing more adaptable devices and correction of multiple components of the mitral annulus to attain durable results. The mitral valve apparatus is a complex structure and understanding of the mechanisms of MR is essential in the development of TMVI. There will likely be a complementary role between surgery and TMVI in the near future.


Subject(s)
Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Cardiac Catheterization/trends , Heart Valve Prosthesis Implantation/trends , Humans , Surgical Instruments , Treatment Outcome
14.
Clin Case Rep ; 3(7): 527-30, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26273434

ABSTRACT

Idiopathic Systemic Capillary Leak Syndrome is a potentially fatal disorder that is under diagnosed. It commonly presents as recurrent undifferentiated shock with hypotension, hypoalbuminemia and hemoconcentration. There are three distinct phases that define the syndrome; Prodromal, Extravasation and Recovery.

SELECTION OF CITATIONS
SEARCH DETAIL
...