Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Language
Publication year range
1.
J Card Surg ; 37(9): 2873-2878, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35665965

ABSTRACT

Kommerell's diverticulum (KD) is a rare congenital vascular abnormality due to the formation of an abnormal aortic arch, most commonly associated with dilatation at the proximal part of the aberrant subclavian artery. This article describes an option of surgical treatment in a patient with KD. The proposed new technique of aortic arch surgical reconstruction with a stent-graft placement in the descending aorta reduces CPB time, aortic clamp and circulatory arrest time.


Subject(s)
Blood Vessel Prosthesis Implantation , Diverticulum , Heart Defects, Congenital , Aorta, Thoracic/abnormalities , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Diverticulum/diagnostic imaging , Diverticulum/surgery , Heart Defects, Congenital/surgery , Humans , Subclavian Artery/abnormalities , Subclavian Artery/diagnostic imaging , Subclavian Artery/surgery
2.
J Thorac Dis ; 12(10): 5639-5646, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33209396

ABSTRACT

BACKGROUND: This study aims to compare the operative and postoperative results of on-pump (ONCAB) and off-pump (OPCAB) coronary artery bypass surgery (CABG) for multi-vessel coronary revascularization (≥4 anastomoses). METHODS: From May 2018 to August 2019, a total of 120 patients (22.5% women, mean age 61.5±8.4 years) received either ONCAB (Group 1, n=60) or OPCAB (Group 2, n=60) for multi-vessel coronary artery disease (CAD). Preoperative left ventricular (LV) ejection fraction (EF) was 53.1%±8.4%. Median EuroSCORE II was 1.59 (interquartile range, 1.01-2.54). The median number of performed coronary anastomoses was 4 (interquartile range, 4-5), with equal distribution in both groups (P=0.4). All procedures were performed by highly experienced surgeons. The primary endpoints were overall survival at 30 days and freedom from severe adverse events (SAE), which included myocardial infarction (MI), coronary artery re-operation, and re-thoracotomy, caused by bleeding and stroke. RESULTS: The overall survival in both groups was 100% with no intraoperative OPCAB-to-on-pump conversion. The median procedure time was 169 min (interquartile range, 150-179 min) for Group 1 and 183 min (interquartile range, 169-205 min) for Group 2 (P<0.001). The overall freedom from SAE numbered 93.3% (98.3% vs. 88.3%, P=0.030). Postoperative MI rate was 2.5% (n=3) with no significant difference for either group (0 vs. 5.0%, P=0.100). One MI patient underwent a re-operation, and two other patients received a conservative treatment. A total of 2.5% (n=3) of patients underwent a re-thoracotomy on account of bleeding (0 vs. 5.0%, P=0.100); no anastomosis-related bleeding was detected. Blood transfusion was applied in 31.7% of patients (38.3% vs. 25.0%, P=0.090). A total of 1.7% of patients (1.7% vs. 1.7%, P=0.800) developed a stroke. Ventilation time, intensive care unit stay, and hospital stay were similar in both groups. CONCLUSIONS: ONCAB showed superior freedom from SAE and shorter procedure times when compared to OPCAB for multi-vessel coronary artery revascularization.

3.
J Card Surg ; 35(12): 3660-3662, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33032372

ABSTRACT

BACKGROUND: Aortic root and ascending aortic aneurysms are traditionally surgically treated through the deployment of a conduit with an artificial aortic valve, which significantly increases the risk of postoperative complications in the form of thrombosis. MATERIALS & METHODS: We report a case of Wolfe procedure in a 78-year-old female patient with aortic root aneurysm at high risk for conventional Bentall surgery. DISCUSSION AND CONCLUSION: We use this case to discuss the effectiveness and short-term results of this procedure.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Aneurysm , Heart Valve Prosthesis Implantation , Aged , Aorta/surgery , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Female , Humans , Postoperative Complications
4.
Braz J Cardiovasc Surg ; 35(3): 241-248, 2020 06 01.
Article in English | MEDLINE | ID: mdl-32549094

ABSTRACT

OBJECTIVE: To determine the feasibility of aortic valve neocuspidization (AVNeo) with glutaraldehyde-treated autologous pericardium. METHODS: One hundred and seventy (170) AVNeo (84 males/86 females) were performed from January 2017 through March 2019 in three centers. All the records were prospectively collected and retrospectively reviewed. RESULTS: Most of the patients were older than 60 years and over 95% were operated for aortic stenosis. Preoperatively, pressure gradients were 69.9±21.3 mmHg for patients with aortic stenosis, and the surgical annular diameter was 21.0±2.0 mm for all patients. Effective orifice area (EOA) and indexed EOA (iEOA) averaged 0.7±0.3 cm2 and 0.4±0.2 cm2/m2 for patients with aortic stenosis before surgery, respectively. There was no conversion to prosthetic aortic valve replacement. Eight patients needed reoperation for bleeding, but no patient needed reoperation due to early infective endocarditis. There were five in-hospital deaths due to noncardiac cause. Compared to preoperative echocardiographic measurements, postoperative peak pressure gradient decreased significantly (-58.7±1.7 mmHg; P<0.001) and reached 11.2±5.6 mmHg, and mean pressure gradient also decreased significantly (-36.8±1.1 mmHg; P<0.001) and reached 6.0±3.5 mmHg. Accordingly, EOA and iEOA increased significantly 2.0 cm2 and 1.0 cm2/m2 (both P<0.001) to reach 2.7±0.6 cm2 and 1.4±0.3 cm2/m2 after surgery, respectively, with minimal significant aortic regurgitation (0.6% > mild). CONCLUSION: AVNeo is feasible and reproducible with good clinical results. Hemodynamically, AVNeo produces immediate postoperative low-pressure gradients, large EOA, and minimal regurgitation of the aortic valve. Further studies are necessary to evaluate mid- and long-term evolution.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Glutaral , Humans , Male , Middle Aged , Pericardium/transplantation , Retrospective Studies , Treatment Outcome
5.
Rev. bras. cir. cardiovasc ; 35(3): 241-248, May-June 2020. tab, graf
Article in English | LILACS, Sec. Est. Saúde SP | ID: biblio-1137266

ABSTRACT

Abstract Objective: To determine the feasibility of aortic valve neocuspidization (AVNeo) with glutaraldehyde-treated autologous pericardium. Methods: One hundred and seventy (170) AVNeo (84 males/86 females) were performed from January 2017 through March 2019 in three centers. All the records were prospectively collected and retrospectively reviewed. Results: Most of the patients were older than 60 years and over 95% were operated for aortic stenosis. Preoperatively, pressure gradients were 69.9±21.3 mmHg for patients with aortic stenosis, and the surgical annular diameter was 21.0±2.0 mm for all patients. Effective orifice area (EOA) and indexed EOA (iEOA) averaged 0.7±0.3 cm2 and 0.4±0.2 cm2/m2 for patients with aortic stenosis before surgery, respectively. There was no conversion to prosthetic aortic valve replacement. Eight patients needed reoperation for bleeding, but no patient needed reoperation due to early infective endocarditis. There were five in-hospital deaths due to noncardiac cause. Compared to preoperative echocardiographic measurements, postoperative peak pressure gradient decreased significantly (-58.7±1.7 mmHg; P<0.001) and reached 11.2±5.6 mmHg, and mean pressure gradient also decreased significantly (-36.8±1.1 mmHg; P<0.001) and reached 6.0±3.5 mmHg. Accordingly, EOA and iEOA increased significantly 2.0 cm2 and 1.0 cm2/m2 (both P<0.001) to reach 2.7±0.6 cm2 and 1.4±0.3 cm2/m2 after surgery, respectively, with minimal significant aortic regurgitation (0.6% > mild). Conclusion: AVNeo is feasible and reproducible with good clinical results. Hemodynamically, AVNeo produces immediate postoperative low-pressure gradients, large EOA, and minimal regurgitation of the aortic valve. Further studies are necessary to evaluate mid- and long-term evolution.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Bioprosthesis , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Pericardium/transplantation , Retrospective Studies , Treatment Outcome , Glutaral
SELECTION OF CITATIONS
SEARCH DETAIL