Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 131
Filter
1.
Interv Cardiol Clin ; 13(2): 183-189, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38432761

ABSTRACT

Mitral regurgitation (MR) is one of the most prevalent types of valvular heart disease and is expected to increase in the next decade. Transcatheter therapies for MR are constantly being developed and studied for use in this population. In this review, the author describes the phenotypes of functional or secondary mitral regurgitation, discusses the potential therapeutic targets for transcatheter intervention, and reviews the results of such technology in the literature.


Subject(s)
Heart Valve Diseases , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/surgery , Technology
2.
Front Cardiovasc Med ; 11: 1334871, 2024.
Article in English | MEDLINE | ID: mdl-38440208

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has emerged as a viable treatment for aortic valve disease, including low-risk patients. However, as TAVR usage increases, concerns about long-term durability and the potential for addition interventions have arisen. Transcatheter aortic valve (TAV)-in-TAV procedures have shown promise in selected patients in numerous registries, offering a less morbid alternative to TAVR explantation. In this review, the authors aimed to comprehensively review the experience surrounding TAV-in-TAV, summarize available data, discuss pre-procedural planning, highlight associated challenges, emphasize the importance of coronary obstruction assessment and provide insights into the future of this technique.

4.
J Invasive Cardiol ; 36(2)2024 Feb.
Article in English | MEDLINE | ID: mdl-38335504

ABSTRACT

OBJECTIVES: The SavvyWire(OpSens Medical) is a support wire for transcatheter aortic valve replacement (TAVR) procedures that, in addition to its dedicated left ventricle (LV) pacing capabilities, has a distal pressure sensor that measures live transvalvular hemodynamics during the procedure. We aimed to determine the safety, efficacy, and functionality of the SavvyWire during TAVR procedures in an all-comer population. METHODS: We performed a multicentric, prospective, observational, single-arm, all-comers registry of patients with symptomatic, severe aortic stenosis undergoing TAVR in 3 Canadian centers. Data were collected in a dedicated database, and pre-specified questionnaires were fulfilled by the heart team implanters after each procedure. RESULTS: A total of 60 patients were included (mean age: 78.6 ± 7.2 years; 51% women; mean Society of Thoracic Surgeons score: 2.2 ± 1.6%). TAVR was performed through a transfemoral approach in 90% of cases, and balloon- and self-expandable valves were used in 73% and 27% of patients, respectively. There were no cases of LV perforation, guidewire deformation, significant loss of capture, or major software malfunction. The rate of successful delivery of the TAVR system was 100%, and effective LV pacing was achieved in 98% of patients. The pre-TAVR mean gradient was 39 ± 14 mm Hg while the final post-TAVR gradient was 8 ± 5 mm Hg; the mean aortic systolic pressure during rapid pacing was 54 ± 12 mm Hg. In 97% of the TAVR procedures, SavvyWire's functionality was reported to be better or similar to other TAVR workhorse support wires. CONCLUSIONS: SavvyWire was safe, effective, and functional for live transvalvular hemodynamic evaluation and rapid pacing during TAVR procedures. More studies with larger sample sizes and comparison against different wires and gradient measurement methods are warranted.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Canada , Hemodynamics , Prospective Studies , Prosthesis Design , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
5.
JACC Case Rep ; 29(4): 102213, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38379645

ABSTRACT

We present a case of a patient known for dextrotransposition of the great arteries corrected with a Mustard procedure, in whom severe mitral valve regurgitation secondary to transvenous lead extraction was successfully repaired with transcatheter edge-to-edge repair using the TriClip device (Abbott Vascular).

6.
Can J Cardiol ; 40(2): 267-274, 2024 02.
Article in English | MEDLINE | ID: mdl-38052302

ABSTRACT

Despite the high procedural success of transcatheter aortic valve replacement (TAVR), 2 out of 5 older adults report poor physical performance and health-related quality of life (HRQOL) in the ensuing months, particularly those with frailty. There has yet to be a trial examining the synergistic effects of exercise and protein supplementation to counteract frailty and improve patient-centred outcomes following TAVR. The PERFORM-TAVR trial is a multicentre parallel-group randomised clinical trial that is enrolling 200 frail older adults ≥ 70 years of age undergoing TAVR. Patients will be randomly allocated to 1 of 2 treatment groups: standard-of-care lifestyle education (control group) or protein-rich oral nutritional supplement for 4 weeks before TAVR with the addition of home-based supervised exercise sessions for 12 weeks after TAVR (intervention group). The primary outcome will be physical performance as measured by a blinded observer using the Short Physical Performance Battery at 3 months. Secondary outcomes at 3, 6, and 12 months will include HRQOL, as measured by the Short-Form 36 Physical and Mental Component summary scores, and a composite safety end point. The PERFORM-TAVR trial is testing a novel frailty intervention in older adults undergoing TAVR to optimise recovery and downstream HRQOL. This represents a potential paradigm shift that highlights the value of assessing and treating patients' frailty in parallel with their underlying heart valve disease. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03522454.


Subject(s)
Aortic Valve Stenosis , Frailty , Transcatheter Aortic Valve Replacement , Aged , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Frailty/complications , Frailty/prevention & control , Quality of Life , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
7.
Can J Cardiol ; 40(4): 500-523, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37820870

ABSTRACT

Cardiovascular conditions are among the most frequent causes of impairment to drive, because they might induce unpredictable mental state alterations via diverse mechanisms like myocardial ischemia, cardiac arrhythmias, and vascular dysfunction. Accordingly, health professionals are often asked to assess patients' fitness to drive (FTD). The Canadian Cardiovascular Society previously published FTD guidelines in 2003-2004; herein, we present updated FTD guidelines. Because there are no randomized trials on FTD, observational studies were used to estimate the risk of driving impairment in each situation, and recommendations made on the basis of Canadian Cardiovascular Society Risk of Harm formula. More restrictive recommendations were made for commercial drivers, who spend longer average times behind the wheel, use larger vehicles, and might transport a larger number of passengers. We provide guidance for individuals with: (1) active coronary artery disease; (2) various forms of valvular heart disease; (3) heart failure, heart transplant, and left ventricular assist device situations; (4) arrhythmia syndromes; (5) implantable devices; (6) syncope history; and (7) congenital heart disease. We suggest appropriate waiting times after cardiac interventions or acute illnesses before driving resumption. When short-term driving cessation is recommended, recommendations are on the basis of expert consensus rather than the Risk of Harm formula because risk elevation is expected to be transient. These recommendations, although not a substitute for clinical judgement or governmental regulations, provide specialists, primary care providers, and allied health professionals with a comprehensive list of a wide range of cardiac conditions, with guidance provided on the basis of the level of risk of impairment, along with recommendations about ability to drive and the suggested duration of restrictions.


Subject(s)
Cardiovascular System , Coronary Artery Disease , Frontotemporal Dementia , Myocardial Ischemia , Humans , Canada/epidemiology , Arrhythmias, Cardiac/therapy
8.
Diagnostics (Basel) ; 13(20)2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37892002

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to open-heart surgery for treating severe aortic stenosis. Despite its benefits, the risk of procedural complications necessitates careful preoperative planning. METHODS: This study proposes a fully automated deep learning-based method, TAVI-PREP, for pre-TAVI planning, focusing on measurements extracted from computed tomography (CT) scans. The algorithm was trained on the public MM-WHS dataset and a small subset of private data. It uses MeshDeformNet for 3D surface mesh generation and a 3D Residual U-Net for landmark detection. TAVI-PREP is designed to extract 22 different measurements from the aortic valvular complex. A total of 200 CT-scans were analyzed, and automatic measurements were compared to the ones made manually by an expert cardiologist. A second cardiologist analyzed 115 scans to evaluate inter-operator variability. RESULTS: High Pearson correlation coefficients between the expert and the algorithm were obtained for most parameters (0.90-0.97), except for left and right coronary height (0.8 and 0.72, respectively). Similarly, the mean absolute relative error was within 5% for most measurements, except for left and right coronary height (11.6% and 16.5%, respectively). A greater consensus was observed among experts than when compared to the automatic approach, with TAVI-PREP showing no discernable bias towards either the lower or higher ends of the measurement spectrum. CONCLUSIONS: TAVI-PREP provides reliable and time-efficient measurements of the aortic valvular complex that could aid clinicians in the preprocedural planning of TAVI procedures.

9.
CJC Open ; 5(8): 611-618, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37720184

ABSTRACT

Patients with new-onset left bundle branch block (LBBB) after transcatheter aortic valve implantation (TAVI) are at risk of developing delayed high-degree atrioventricular block. Management of new-onset LBBB post-TAVI remains controversial. In the Comparison of a Clinical Monitoring Strategy Versus Electrophysiology-Guided Algorithmic Approach in Patients With a New LBBB After TAVI (COME-TAVI) trial, consenting patients with new-onset LBBB that persists on day 2 after TAVI, meeting exclusion/inclusion criteria, are randomized to an electrophysiological study (EPS)-guided approach or 30-day electrocardiographic monitoring. In the EPS-guided approach, patients with a His to ventricle (HV) interval ≥ 65 ms undergo permanent pacemaker implantation. Patients randomized to noninvasive monitoring receive a wearable continuous electrocardiographic recording and transmitting device for 30 days. Follow-up will be performed at 3, 6, and 12 months. The primary endpoint is a composite outcome designed to capture net clinical benefit. The endpoint incorporates major consequences of both strategies in patients with new-onset LBBB after TAVI, as follows: (i) sudden cardiac death; (ii) syncope; (iii) atrioventricular conduction disorder requiring a pacemaker (for a class I or IIa indication); and (iv) complications related to the pacemaker or EPS. The trial incorporates a Bayesian design with a noninformative prior, outcome-adaptive randomization (initially 1:1), and 2 prespecified interim analyses once 25% and 50% of the anticipated number of primary endpoints are reached. The trial is event-driven, with an anticipated upper limit of 452 patients required to reach 77 primary outcome events over 12 months of follow-up. In summary, the aim of this Bayesian multicentre randomized trial is to compare 2 management strategies in patients with new-onset LBBB post-TAVI-an EPS-guided approach vs noninvasive 30-day monitoring. Trial registration number: NCT03303612.


Les patients chez qui un bloc de branche gauche (BBG) est récemment apparu à la suite de l'implantation valvulaire aortique par cathéter (IVAC) présentent un risque de bloc auriculoventriculaire de haut degré tardif. La prise en charge d'un BBG récemment apparu après une IVAC demeure controversée. Dans le cadre de l'essai COME-TAVI (Comparison of a ClinicalMonitoring Strategy VersusElectrophysiology-Guided Algorithmic Approach in Patients With a New LBBB AfterTAVI, ou comparaison d'une stratégie de surveillance clinique, par rapport à une approche guidée par étude électrophysiologique et fondée sur un algorithme, chez des patients présentant un BBG d'apparition récente à la suite d'une IVAC), des patients qui présentent un BBG d'apparition récente persistant le 2e jour après une IVAC, qui répondent aux critères d'admissibilité et qui ont donné leur consentement sont répartis aléatoirement pour être suivis à l'aide d'une approche guidée par une étude électrophysiologique (EEP) ou faire l'objet d'une surveillance électrocardiographique d'une durée de 30 jours. Un stimulateur cardiaque est implanté chez les patients du groupe de l'EEP dont l'intervalle HV (temps de conduction dans le tronc du faisceau de His jusqu'aux ventricules) est ≥ 65 ms. Les patients du groupe de surveillance non invasive reçoivent un dispositif portable d'enregistrement et de transmission continue de données électrocardiographiques pour une période de 30 jours. Le suivi sera réalisé aux 3e, 6e et 12e mois. Le critère d'évaluation principal est un paramètre composite conçu afin de saisir le bienfait clinique net. Il comprend les conséquences majeures des deux stratégies chez les patients présentant un BBG d'apparition récente après une IVAC, comme suit : (i) mort subite d'origine cardiaque; (ii) syncope; (iii) trouble de la conduction auriculoventriculaire nécessitant la pose d'un stimulateur cardiaque (pour une indication de classe I ou IIa); et (iv) complications relatives au stimulateur cardiaque ou à l'EEP. L'essai intègre une conception bayésienne avec une répartition aléatoire (dans un rapport initial de 1:1) antérieure non informative adaptée aux résultats et deux analyses intermédiaires définies au préalable lorsque 25 % et 50 % du nombre anticipé des critères d'évaluation principaux seront atteints. L'essai est axé sur les événements, et la limite supérieure anticipée pour atteindre 77 événements relatifs aux critères d'évaluation principaux sur 12 mois de suivi est de 452 patients. En résumé, l'objectif de cet essai bayésien multicentrique à répartition aléatoire est de comparer deux stratégies de prise en charge de patients présentant un BBG d'apparition récente après une IVAC, soit une approche guidée par une EEP, par rapport à une surveillance non invasive de 30 jours. Trial registration number: NCT03303612.

11.
Int J Cardiol ; 390: 131139, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37355239

ABSTRACT

BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.


Subject(s)
Heart Failure , Heart Transplantation , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Middle Aged , Stroke Volume , Ventricular Function, Left , Time Factors , Heart Transplantation/adverse effects , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Heart Failure/diagnosis , Heart Failure/surgery , Registries , Heart Valve Prosthesis Implantation/methods
12.
JACC Cardiovasc Interv ; 16(12): 1474-1485, 2023 06 26.
Article in English | MEDLINE | ID: mdl-37380229

ABSTRACT

BACKGROUND: Anatomical and clinical criteria to define mitral transcatheter edge-to-edge repair (TEER) "unsuitability" have been proposed on the basis of a Heart Valve Collaboratory consensus opinion from physician experience with early-generation TEER devices but lacked an evidence-based approach. OBJECTIVES: The aim of this study was to explore the spectrum of TEER suitability using echocardiographic and clinical outcomes from the EXPAND G4 real-world postapproval study. METHODS: EXPAND G4 is a global, prospective, multicenter, single-arm study that enrolled 1,164 subjects with mitral regurgitation (MR) treated with the MitraClip G4 System. Three groups were defined using the Heart Valve Collaboratory TEER unsuitability criteria: 1) risk of stenosis (RoS); 2) risk of inadequate MR reduction (RoIR); and 3) subjects with baseline moderate or less MR (MMR). A TEER-suitable (TS) group was defined by the absence of these characteristics. Endpoints included independent core laboratory-assessed echocardiographic characteristics, procedural outcomes, MR reduction, NYHA functional class, Kansas City Cardiomyopathy Questionnaire score, and major adverse events through 30 days. RESULTS: Subjects in the RoS (n = 56), RoIR (n = 54), MMR (n = 326), and TS (n = 303) groups had high 30-day MR reduction rates (≤1+: RoS 97%, MMR 93%, and TS 91%; ≤2+: RoIR 94%). Thirty-day improvements in functional capacity (NYHA functional class I or II at 30 days vs baseline: RoS 94% vs 29%, RoIR 88% vs 30%, MMR 79% vs 26%, and TS 83% vs 33%) and quality of life (change in Kansas City Cardiomyopathy Questionnaire score: RoS +27 ± 26, RoIR +16 ± 26, MMR +19 ± 26, and TS +19 ± 24) were safely achieved in all groups, with low major adverse events (<3%) and all-cause mortality (RoS 1.8%, RoIR 0%, MMR 1.5%, and TS 1.3%). CONCLUSIONS: Patients previously deemed TEER unsuitable can be safely and effectively treated with the mitral TEER fourth-generation device.


Subject(s)
Cardiomyopathies , Mitral Valve Insufficiency , Humans , Prospective Studies , Quality of Life , Reactive Oxygen Species , Treatment Outcome , Constriction, Pathologic , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery
13.
JACC Cardiovasc Interv ; 16(10): 1176-1188, 2023 05 22.
Article in English | MEDLINE | ID: mdl-37225288

ABSTRACT

BACKGROUND: Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES: The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS: Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS: From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS: The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.


Subject(s)
Mitral Valve Insufficiency , Humans , Middle Aged , Aged , Aged, 80 and over , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Retrospective Studies , Treatment Outcome , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Registries
14.
Front Cardiovasc Med ; 10: 1071805, 2023.
Article in English | MEDLINE | ID: mdl-36993995

ABSTRACT

Aortic, mitral and tricuspid valve regurgitation are commonly encountered in patients with continuous-flow left ventricular assist devices (CF-LVADs). These valvular heart conditions either develop prior to CF-LVAD implantation or are induced by the pump itself. They can all have significant detrimental effects on patients' survival and quality of life. With the improved durability of CF-LVADs and the overall rise in their volume of implants, an increasing number of patients will likely require a valvular heart intervention at some point during CF-LVAD therapy. However, these patients are often considered poor reoperative candidates. In this context, percutaneous approaches have emerged as an attractive "off-label" option for this patient population. Recent data show promising results, with high device success rates and rapid symptomatic improvements. However, the occurrence of distinct complications such as device migration, valve thrombosis or hemolysis remain of concern. In this review, we will present the pathophysiology of valvular heart disease in the setting of CF-LVAD support to help us understand the underlying rationale of these potential complications. We will then outline the current recommendations for the management of valvular heart disease in patients with CF-LVAD and discuss their limitations. Lastly, we will summarize the evidence related to transcatheter heart valve interventions in this patient population.

15.
J Am Heart Assoc ; 12(4): e027504, 2023 02 21.
Article in English | MEDLINE | ID: mdl-36752231

ABSTRACT

Background The current standard of care for the treatment of patients with primary mitral regurgitation (MR) is surgical mitral valve repair. Transcatheter edge-to-edge repair with the MitraClip device provides a less invasive treatment option for patients with both primary and secondary MR. Worldwide, >150 000 patients have been treated with the MitraClip device. However, in the United States, MitraClip is approved for use only in primary patients with MR who are at high or prohibitive risk for mitral valve surgery. The REPAIR MR (Percutaneous MitraClip Device or Surgical Mitral Valve Repair in Patients With Primary Mitral Regurgitation Who Are Candidates for Surgery) trial is designed to compare early and late outcomes associated with transcatheter edge-to-edge repair with the MitraClip and surgical repair of primary MR in older or moderate surgical risk patients. Methods and Results The REPAIR MR trial is a prospective, randomized, parallel-controlled, open-label multicenter, noninferiority trial for the treatment of severe primary MR (verified by an independent echocardiographic core laboratory). Patients with severe MR and indications for surgery because of symptoms (New York Heart Association class II-IV), or without symptoms with left ventricular ejection fraction ≤60%, pulmonary artery systolic pressure >50 mm Hg, or left ventricular end-systolic diameter ≥40 mm are eligible for the trial provided they meet the moderate surgical risk criteria as follows: (1) ≥75 years of age, or (2) if <75 years of age, then the subject has a Society of Thoracic Surgeons Predicted Risk Of Mortality score of ≥2% for mitral repair (or Society of Thoracic Surgeons replacement score of ≥4%), or the presence of a comorbidity that may introduce a surgery-specific risk. The local surgeon must determine that the mitral valve can be surgically repaired. Additionally, an independent eligibility committee will confirm that the MR can be reduced to mild or less with both the MitraClip and surgical mitral valve repair with a high degree of certainty. A total of 500 eligible subjects will be randomized in a 1:1 ratio to receive the MitraClip device or to undergo surgical mitral valve repair (control group). There are 2 co-primary end points for the trial, both of which will be evaluated at 2 years. Each subject will be followed for 10 years after enrollment. The study has received approval from both the Food and Drug Administration and the Centers for Medicare and Medicaid Services, and enrolled its first subject in July 2020. Conclusions The REPAIR MR trial will determine the safety and effectiveness of transcatheter edge-to-edge repair with the MitraClip in patients with primary MR who are at moderate surgical risk and are candidates for surgical MV repair. The trial will generate contemporary comparative clinical evidence for the MitraClip device and surgical MV repair. Registration https://clinicaltrials.gov/ct2/show/NCT04198870; NCT04198870.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Aged , United States , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Stroke Volume , Prospective Studies , Treatment Outcome , Ventricular Function, Left , Medicare , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization/adverse effects
17.
Am J Cardiol ; 186: 11-16, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36334433

ABSTRACT

In aortic stenosis (AS), left ventricular (LV) remodeling often occurs before symptom onset, and early intervention may be beneficial. Risk stratification remains challenging and identification of biomarkers may be useful. We evaluated the association between growth differentiation factor-15 (GDF-15) and soluble suppression of tumorigenicity 2 (sST2) and known markers of poor prognosis in AS. Baseline plasma GDF-15 and sST2 levels were measured in 70 patients with moderate-severe AS (aortic valve area <1.5 cm2) and preserved LV ejection fraction (>45%). Patients were categorized into "low GDF-15" versus "high GDF-15" and "low sST2" versus "high sST2" groups. Groups were compared for differences in cardiovascular risk factors, 6-minute walk test, 5 m gait speed, cognitive function (Montreal Cognitive Assessment), and echocardiographic parameters. Overall, 44% of patients were deemed asymptomatic by New York Heart Association class, 61% had severe AS (aortic valve area <1 cm2) and all patients had preserved LV ejection fraction. GDF-15 levels were not predictive of AS severity. However, high GDF-15 (>1,050 pg/ml) was associated with LV dysfunction as shown by lower indexed stroke volume (p <0.01), worse LV global longitudinal strain (p = 0.04), greater mean E/e' (p = 0.02) and indexed left atrial volume (p <0.01). It was also associated with decreased functional capacity with shorter 6-minute walk test (p = 0.01) and slower 5 m gait speed (p = 0.02). Associations between sST2 levels and markers of poor prognosis were less compelling. In this study of patients with moderate to severe AS, elevated GDF-15 levels are associated with impaired functional capacity, poorer performance on fragility testing, and LV dysfunction. In conclusion, GDF-15 may integrate these markers of adverse outcomes into a single biomarker of poor prognosis.


Subject(s)
Aortic Valve Stenosis , Frailty , Ventricular Dysfunction, Left , Humans , Stroke Volume , Ventricular Function, Left , Growth Differentiation Factor 15 , Frailty/complications , Risk Factors , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Ventricular Remodeling
19.
Circ Cardiovasc Interv ; 15(10): e012168, 2022 10.
Article in English | MEDLINE | ID: mdl-36256698

ABSTRACT

BACKGROUND: The 3M-TAVR trial (3M-Transcatheter Aortic Valve Replacement) demonstrated the feasibility and safety of next-day hospital discharge after transfemoral TAVR with implementation of a minimalist pathway. However, the economic impact of this approach is unknown. Therefore, we evaluated costs for patients undergoing minimalist TAVR compared with conventional TAVR. METHODS: We used propensity matching to compare resource utilization and costs (from a US health care system perspective) for patients in the 3M-TAVR trial with those for transfemoral TAVR patients enrolled in the contemporaneous S3i trial (PARTNER SAPIEN-3 Intermediate Risk). Procedural costs were estimated using measured resource utilization for both groups. For the S3i group, all other costs through 30-day follow-up were assessed by linkage with Medicare claims; for 3M, these costs were assessed using regression models derived from S3i cost and resource utilization data. RESULTS: After 1:1 propensity matching, 351 pairs were included in our study (mean age 82, mean Society of Thoracic Surgery risk score 5.3%). There were no differences in death, stroke, or rehospitalization between the 3M-TAVR and S3i groups through 30-day follow-up. Index hospitalization costs were $10 843/patient lower in the 3M-TAVR cohort, driven by reductions in procedure duration, anesthesia costs, and length of stay. Between discharge and 30 days, costs were similar for the 2 groups such that cumulative 30-day costs were $11 305/patient lower in the 3M-TAVR cohort compared with the S3i cohort ($49 425 versus $60 729, 95% CI for difference $9378 to $13 138; P<0.001). CONCLUSIONS: Compared with conventional transfemoral TAVR, use of a minimalist pathway in intermediate-risk patients was associated with similar clinical outcomes and substantial in-hospital cost savings, which were sustained through 30 days. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02287662.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Humans , Aortic Valve Stenosis/surgery , Medicare/economics , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , United States
20.
Front Cardiovasc Med ; 9: 931207, 2022.
Article in English | MEDLINE | ID: mdl-35966561

ABSTRACT

Background: A severe prosthesis-patient mismatch (PPM) is associated with adverse outcomes following transcatheter aortic valve replacement (TAVR) for de novo aortic stenosis or a failed surgical bioprosthesis. The impact of severe PPM in patients undergoing TAV-in-TAVR is unknown. Aim: We sought to investigate the incidence and 1-year outcomes of different grades of PPM in patients undergoing TAV-in-TAVR. Materials and methods: The TRANSIT-PPM is an international registry, including cases of degenerated TAVR treated with a second TAVR. PPM severity, as well as in-hospital, 30-day, and 1-year outcomes were defined according to the Valve Academic Research Consortium-3 (VARC-3) criteria. Results: Among 28 centers, 155 patients were included. Severe PPM was found in 6.5% of patients, whereas moderate PPM was found in 14.2% of patients. The rate of severe PPM was higher in patients who underwent TAV-in-TAVR with a second supra-annular self-expanding (S-SE) TAVR (10%, p = 0.04). Specifically, the rate of severe PPM was significantly higher among cases of a SE TAVR implanted into a balloon-expandable (BE) device (19%, p = 0.003). At 1-year follow-up, the rate of all-cause mortality, and the rate of patients in the New York Heart Association (NYHA) class III/IV were significantly higher in the cohort of patients with severe PPM (p = 0.016 and p = 0.0001, respectively). Almost all the patients with a severe PPM after the first TAVR had a failed < 23 mm BE transcatheter heart valve (THV): the treatment with an S-SE resolved the severe PPM in the majority of the cases. Conclusion: After TAV-in-TAVR, in a fifth of the cases, a moderate or severe PPM occurred. A severe PPM is associated with an increased 1-year all-cause mortality. Clinical trial registration: [https://clinicaltrials.gov], identifier [NCT04500964].

SELECTION OF CITATIONS
SEARCH DETAIL
...