Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 87
Filter
1.
Interv Cardiol Clin ; 13(2): 183-189, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38432761

ABSTRACT

Mitral regurgitation (MR) is one of the most prevalent types of valvular heart disease and is expected to increase in the next decade. Transcatheter therapies for MR are constantly being developed and studied for use in this population. In this review, the author describes the phenotypes of functional or secondary mitral regurgitation, discusses the potential therapeutic targets for transcatheter intervention, and reviews the results of such technology in the literature.


Subject(s)
Heart Valve Diseases , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/surgery , Technology
3.
J Invasive Cardiol ; 36(2)2024 Feb.
Article in English | MEDLINE | ID: mdl-38335504

ABSTRACT

OBJECTIVES: The SavvyWire(OpSens Medical) is a support wire for transcatheter aortic valve replacement (TAVR) procedures that, in addition to its dedicated left ventricle (LV) pacing capabilities, has a distal pressure sensor that measures live transvalvular hemodynamics during the procedure. We aimed to determine the safety, efficacy, and functionality of the SavvyWire during TAVR procedures in an all-comer population. METHODS: We performed a multicentric, prospective, observational, single-arm, all-comers registry of patients with symptomatic, severe aortic stenosis undergoing TAVR in 3 Canadian centers. Data were collected in a dedicated database, and pre-specified questionnaires were fulfilled by the heart team implanters after each procedure. RESULTS: A total of 60 patients were included (mean age: 78.6 ± 7.2 years; 51% women; mean Society of Thoracic Surgeons score: 2.2 ± 1.6%). TAVR was performed through a transfemoral approach in 90% of cases, and balloon- and self-expandable valves were used in 73% and 27% of patients, respectively. There were no cases of LV perforation, guidewire deformation, significant loss of capture, or major software malfunction. The rate of successful delivery of the TAVR system was 100%, and effective LV pacing was achieved in 98% of patients. The pre-TAVR mean gradient was 39 ± 14 mm Hg while the final post-TAVR gradient was 8 ± 5 mm Hg; the mean aortic systolic pressure during rapid pacing was 54 ± 12 mm Hg. In 97% of the TAVR procedures, SavvyWire's functionality was reported to be better or similar to other TAVR workhorse support wires. CONCLUSIONS: SavvyWire was safe, effective, and functional for live transvalvular hemodynamic evaluation and rapid pacing during TAVR procedures. More studies with larger sample sizes and comparison against different wires and gradient measurement methods are warranted.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Canada , Hemodynamics , Prospective Studies , Prosthesis Design , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
4.
JACC Case Rep ; 29(4): 102213, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38379645

ABSTRACT

We present a case of a patient known for dextrotransposition of the great arteries corrected with a Mustard procedure, in whom severe mitral valve regurgitation secondary to transvenous lead extraction was successfully repaired with transcatheter edge-to-edge repair using the TriClip device (Abbott Vascular).

5.
Can J Cardiol ; 40(4): 500-523, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37820870

ABSTRACT

Cardiovascular conditions are among the most frequent causes of impairment to drive, because they might induce unpredictable mental state alterations via diverse mechanisms like myocardial ischemia, cardiac arrhythmias, and vascular dysfunction. Accordingly, health professionals are often asked to assess patients' fitness to drive (FTD). The Canadian Cardiovascular Society previously published FTD guidelines in 2003-2004; herein, we present updated FTD guidelines. Because there are no randomized trials on FTD, observational studies were used to estimate the risk of driving impairment in each situation, and recommendations made on the basis of Canadian Cardiovascular Society Risk of Harm formula. More restrictive recommendations were made for commercial drivers, who spend longer average times behind the wheel, use larger vehicles, and might transport a larger number of passengers. We provide guidance for individuals with: (1) active coronary artery disease; (2) various forms of valvular heart disease; (3) heart failure, heart transplant, and left ventricular assist device situations; (4) arrhythmia syndromes; (5) implantable devices; (6) syncope history; and (7) congenital heart disease. We suggest appropriate waiting times after cardiac interventions or acute illnesses before driving resumption. When short-term driving cessation is recommended, recommendations are on the basis of expert consensus rather than the Risk of Harm formula because risk elevation is expected to be transient. These recommendations, although not a substitute for clinical judgement or governmental regulations, provide specialists, primary care providers, and allied health professionals with a comprehensive list of a wide range of cardiac conditions, with guidance provided on the basis of the level of risk of impairment, along with recommendations about ability to drive and the suggested duration of restrictions.


Subject(s)
Cardiovascular System , Coronary Artery Disease , Frontotemporal Dementia , Myocardial Ischemia , Humans , Canada/epidemiology , Arrhythmias, Cardiac/therapy
7.
JACC Cardiovasc Interv ; 16(12): 1474-1485, 2023 06 26.
Article in English | MEDLINE | ID: mdl-37380229

ABSTRACT

BACKGROUND: Anatomical and clinical criteria to define mitral transcatheter edge-to-edge repair (TEER) "unsuitability" have been proposed on the basis of a Heart Valve Collaboratory consensus opinion from physician experience with early-generation TEER devices but lacked an evidence-based approach. OBJECTIVES: The aim of this study was to explore the spectrum of TEER suitability using echocardiographic and clinical outcomes from the EXPAND G4 real-world postapproval study. METHODS: EXPAND G4 is a global, prospective, multicenter, single-arm study that enrolled 1,164 subjects with mitral regurgitation (MR) treated with the MitraClip G4 System. Three groups were defined using the Heart Valve Collaboratory TEER unsuitability criteria: 1) risk of stenosis (RoS); 2) risk of inadequate MR reduction (RoIR); and 3) subjects with baseline moderate or less MR (MMR). A TEER-suitable (TS) group was defined by the absence of these characteristics. Endpoints included independent core laboratory-assessed echocardiographic characteristics, procedural outcomes, MR reduction, NYHA functional class, Kansas City Cardiomyopathy Questionnaire score, and major adverse events through 30 days. RESULTS: Subjects in the RoS (n = 56), RoIR (n = 54), MMR (n = 326), and TS (n = 303) groups had high 30-day MR reduction rates (≤1+: RoS 97%, MMR 93%, and TS 91%; ≤2+: RoIR 94%). Thirty-day improvements in functional capacity (NYHA functional class I or II at 30 days vs baseline: RoS 94% vs 29%, RoIR 88% vs 30%, MMR 79% vs 26%, and TS 83% vs 33%) and quality of life (change in Kansas City Cardiomyopathy Questionnaire score: RoS +27 ± 26, RoIR +16 ± 26, MMR +19 ± 26, and TS +19 ± 24) were safely achieved in all groups, with low major adverse events (<3%) and all-cause mortality (RoS 1.8%, RoIR 0%, MMR 1.5%, and TS 1.3%). CONCLUSIONS: Patients previously deemed TEER unsuitable can be safely and effectively treated with the mitral TEER fourth-generation device.


Subject(s)
Cardiomyopathies , Mitral Valve Insufficiency , Humans , Prospective Studies , Quality of Life , Reactive Oxygen Species , Treatment Outcome , Constriction, Pathologic , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery
8.
JACC Cardiovasc Interv ; 16(10): 1176-1188, 2023 05 22.
Article in English | MEDLINE | ID: mdl-37225288

ABSTRACT

BACKGROUND: Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES: The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS: Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS: From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS: The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.


Subject(s)
Mitral Valve Insufficiency , Humans , Middle Aged , Aged , Aged, 80 and over , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Retrospective Studies , Treatment Outcome , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Registries
9.
J Am Heart Assoc ; 12(4): e027504, 2023 02 21.
Article in English | MEDLINE | ID: mdl-36752231

ABSTRACT

Background The current standard of care for the treatment of patients with primary mitral regurgitation (MR) is surgical mitral valve repair. Transcatheter edge-to-edge repair with the MitraClip device provides a less invasive treatment option for patients with both primary and secondary MR. Worldwide, >150 000 patients have been treated with the MitraClip device. However, in the United States, MitraClip is approved for use only in primary patients with MR who are at high or prohibitive risk for mitral valve surgery. The REPAIR MR (Percutaneous MitraClip Device or Surgical Mitral Valve Repair in Patients With Primary Mitral Regurgitation Who Are Candidates for Surgery) trial is designed to compare early and late outcomes associated with transcatheter edge-to-edge repair with the MitraClip and surgical repair of primary MR in older or moderate surgical risk patients. Methods and Results The REPAIR MR trial is a prospective, randomized, parallel-controlled, open-label multicenter, noninferiority trial for the treatment of severe primary MR (verified by an independent echocardiographic core laboratory). Patients with severe MR and indications for surgery because of symptoms (New York Heart Association class II-IV), or without symptoms with left ventricular ejection fraction ≤60%, pulmonary artery systolic pressure >50 mm Hg, or left ventricular end-systolic diameter ≥40 mm are eligible for the trial provided they meet the moderate surgical risk criteria as follows: (1) ≥75 years of age, or (2) if <75 years of age, then the subject has a Society of Thoracic Surgeons Predicted Risk Of Mortality score of ≥2% for mitral repair (or Society of Thoracic Surgeons replacement score of ≥4%), or the presence of a comorbidity that may introduce a surgery-specific risk. The local surgeon must determine that the mitral valve can be surgically repaired. Additionally, an independent eligibility committee will confirm that the MR can be reduced to mild or less with both the MitraClip and surgical mitral valve repair with a high degree of certainty. A total of 500 eligible subjects will be randomized in a 1:1 ratio to receive the MitraClip device or to undergo surgical mitral valve repair (control group). There are 2 co-primary end points for the trial, both of which will be evaluated at 2 years. Each subject will be followed for 10 years after enrollment. The study has received approval from both the Food and Drug Administration and the Centers for Medicare and Medicaid Services, and enrolled its first subject in July 2020. Conclusions The REPAIR MR trial will determine the safety and effectiveness of transcatheter edge-to-edge repair with the MitraClip in patients with primary MR who are at moderate surgical risk and are candidates for surgical MV repair. The trial will generate contemporary comparative clinical evidence for the MitraClip device and surgical MV repair. Registration https://clinicaltrials.gov/ct2/show/NCT04198870; NCT04198870.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Aged , United States , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Stroke Volume , Prospective Studies , Treatment Outcome , Ventricular Function, Left , Medicare , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization/adverse effects
11.
Front Cardiovasc Med ; 9: 931207, 2022.
Article in English | MEDLINE | ID: mdl-35966561

ABSTRACT

Background: A severe prosthesis-patient mismatch (PPM) is associated with adverse outcomes following transcatheter aortic valve replacement (TAVR) for de novo aortic stenosis or a failed surgical bioprosthesis. The impact of severe PPM in patients undergoing TAV-in-TAVR is unknown. Aim: We sought to investigate the incidence and 1-year outcomes of different grades of PPM in patients undergoing TAV-in-TAVR. Materials and methods: The TRANSIT-PPM is an international registry, including cases of degenerated TAVR treated with a second TAVR. PPM severity, as well as in-hospital, 30-day, and 1-year outcomes were defined according to the Valve Academic Research Consortium-3 (VARC-3) criteria. Results: Among 28 centers, 155 patients were included. Severe PPM was found in 6.5% of patients, whereas moderate PPM was found in 14.2% of patients. The rate of severe PPM was higher in patients who underwent TAV-in-TAVR with a second supra-annular self-expanding (S-SE) TAVR (10%, p = 0.04). Specifically, the rate of severe PPM was significantly higher among cases of a SE TAVR implanted into a balloon-expandable (BE) device (19%, p = 0.003). At 1-year follow-up, the rate of all-cause mortality, and the rate of patients in the New York Heart Association (NYHA) class III/IV were significantly higher in the cohort of patients with severe PPM (p = 0.016 and p = 0.0001, respectively). Almost all the patients with a severe PPM after the first TAVR had a failed < 23 mm BE transcatheter heart valve (THV): the treatment with an S-SE resolved the severe PPM in the majority of the cases. Conclusion: After TAV-in-TAVR, in a fifth of the cases, a moderate or severe PPM occurred. A severe PPM is associated with an increased 1-year all-cause mortality. Clinical trial registration: [https://clinicaltrials.gov], identifier [NCT04500964].

12.
J Am Coll Cardiol ; 79(15): 1506-1518, 2022 04 19.
Article in English | MEDLINE | ID: mdl-35422247

ABSTRACT

Numerous sex-based differences are observed across the spectrum of valvular heart disease, starting with pathophysiology and progression of disease, moving on to compensation and comorbidities (both cardiovascular such as coronary artery disease and noncardiovascular such as frailty), assessment of severity and hemodynamics including timing of intervention, and procedural risks/benefits and outcomes. The aortic valve is perhaps best understood with sex differences in both pathologic changes and response to volume and pressure overload, yet large gaps in our understanding still exist. Studies of other valve diseases have focused on differences in prevalence, presentation, and outcomes for surgical or transcatheter therapies. Defining sex-specific responses to valvular heart disease may improve disease recognition, define treatment strategies, and improve outcomes.


Subject(s)
Heart Valve Diseases , Heart Valve Prosthesis Implantation , Aortic Valve/surgery , Female , Heart Valve Diseases/surgery , Hemodynamics , Humans , Male , Sex Factors
14.
Can J Cardiol ; 38(10 Suppl1): S54-S65, 2022 10.
Article in English | MEDLINE | ID: mdl-33383168

ABSTRACT

The prevalence of mitral valve disease has evolved over the past 5 decades from primarily a disease of rheumatic origin to a disease affecting the aging population that encompasses a range of phenotypes from rheumatic mitral stenosis, degenerative mitral regurgitation, and degenerative mitral valve calcification to secondary mitral regurgitation. A reflection on the history of therapy for mitral valve disease is an expedition that follows the birth and development of structural heart intervention from the first percutaneous balloon mitral valvuloplasty to innovative technologies for transcatheter mitral valve repair and replacement. This review will lead you along this journey, pause to acknowledge the feats accomplished, and reflect on the road that lies ahead.


Subject(s)
Balloon Valvuloplasty , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve Stenosis , Heart Valve Diseases/surgery , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery , Mitral Valve Stenosis/surgery , Treatment Outcome
15.
ESC Heart Fail ; 9(1): 450-464, 2022 02.
Article in English | MEDLINE | ID: mdl-34953062

ABSTRACT

AIMS: Right ventricular (RV) dysfunction, pulmonary hypertension, and exercise intolerance have prognostic values, but their interrelation is not fully understood. We investigated how RV function alone and its coupling with pulmonary circulation (RV-PA) predict cardio-respiratory fitness in patients with heart failure and reduced ejection fraction (HFrEF). METHODS AND RESULTS: The Evaluation of Resynchronization Therapy for Heart Failure (EARTH) study included 205 HFrEF patients with narrow (n = 85) and prolonged (n = 120) QRS duration undergoing implantable cardioverter defibrillator implantation. All patients underwent a comprehensive evaluation with exercise tolerance tests and echocardiography. We investigated the correlations at baseline between RV parameters {size, function [tricuspid annular plane systolic excursion (TAPSE), RV fractional area change (RV-FAC), and RV myocardial performance index (RV-MPI)], pulmonary artery systolic pressure (PASP), and tricuspid regurgitation}; left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume index (LVEDVi), and left atrial volume index (LAVi); and cardiopulmonary exercise test (CPET) [peak VO2 , minute ventilation/carbon dioxide production (VE/VCO2 ), 6 min walk distance (6MWD), and submaximal exercise duration (SED)]. We also studied the relationship between RV-PA coupling (TAPSE/PASP ratio) and echocardiographic parameters in patients with both data available. Univariate and multivariate linear regression models were used. Patients enrolled in EARTH (overall population) were mostly male (73.2%), mean age 61.0 ± 9.8 years, New York Heart Association class II-III (87.8%), mean LVEF of 26.6 ± 7.7%, and reduced peak VO2 (15.1 ± 4.6 mL/kg/min). Of these, 100 had both TAPSE and PASP available (TAPSE/PASP population): they exhibited higher BNP, wider QRS duration, larger LVEDVi, with more having tricuspid regurgitation compared with the 105 patients for whom these values were not available (all P < 0.05). RV-FAC (ß = 7.5), LAVi (ß = -0.1), and sex (female, ß = -1.9) predicted peak VO2 in the overall population (all P = 0.01). When available, TAPSE/PASP ratio was the only echocardiographic parameter associated with peak VO2 (ß = 6.8; P < 0.01), a threshold ≤0.45 predicting a peak VO2  ≤ 14 mL/kg/min (0.39 for VO2  ≤ 12). RV-MPI was the only echocardiographic parameter associated with ventilatory inefficiency (VE/VCO2 ) and 6MWD (ß = 21.9 and ß = -69.3, respectively, both P ≤ 0.01) in the overall population. In presence of TAPSE/PASP, it became an important predictor for those two CPET (ß = -18.0 and ß = 72.4, respectively, both P < 0.01), together with RV-MPI (ß = 18.5, P < 0.01) for VE/VCO2 . Tricuspid regurgitation predicted SED (ß = -3.2, P = 0.03). CONCLUSIONS: Right ventricular function assessed by echocardiography (RV-MPI and RV-FAC) is closely associated with exercise tolerance in patients with HFrEF. When the TAPSE/PASP ratio is available, this marker of RV-PA coupling becomes the stronger echocardiographic predictor of exercise capacity in this population, highlighting its potential role as a screening tool to identify patients with reduced exercise capacity and potentially triage them to formal peak VO2 and/or evaluation for advanced HF therapies.


Subject(s)
Exercise Tolerance , Heart Failure, Systolic , Aged , Female , Heart Failure, Systolic/diagnosis , Humans , Male , Middle Aged , Pulmonary Circulation , Stroke Volume , Ventricular Function, Left , Ventricular Function, Right
19.
Circ Cardiovasc Interv ; 14(6): e010440, 2021 06.
Article in English | MEDLINE | ID: mdl-34092097

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has determined a paradigm shift in the treatment of patients with severe aortic stenosis. However, the durability of bioprostheses is still a matter of concern, and little is known about the management of degenerated TAV. We sought to evaluate the outcomes of patients with a degenerated TAV treated by means of a second TAVR. METHODS: The TRANSIT is an international registry that included cases of degenerated TAVR from 28 centers. Among around 40 000 patients treated with TAVR in the participating centers, 172 underwent a second TAVR: 57 (33%) for a mainly stenotic degenerated TAV, 97 (56%) for a mainly regurgitant TAV, and 18 (11%) for a combined degeneration. Overall, the rate of New York Heart Association class III/IV at presentation was 73.5%. RESULTS: Valve Academic Research Consortium 2 device success rate was 79%, as a consequence of residual gradient (14%) or regurgitation (7%). At 1 month, the overall mortality rate was 2.9%, while rates of new hospitalization and New York Heart Association class III/IV were 3.6% and 7%, respectively, without significant difference across the groups. At 1 year, the overall mortality rate was 10%, while rates of new hospitalization and New York Heart Association class III/IV were 7.6% and 5.8%, respectively, without significant difference across the groups. No cases of valve thrombosis were recorded. CONCLUSIONS: Selected patients with a degenerated TAV may be safely and successfully treated by means of a second TAVR. This finding is of crucial importance for the adoption of the TAVR technology in a lower risk and younger population. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04500964.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Prosthesis Failure , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
20.
Circ., cariovasc. interv. (Print) ; 14(6): 010440, June. 2021. graf, ilus, tab
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1352656

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has determined a paradigm shift in the treatment of patients with severe aortic stenosis. However, the durability of bio prostheses is still a matter of concern, and little is known about the management of degenerated TAV. We sought to evaluate the outcomes of patients with a degenerated TAV treated by means of a second TAVR. METHODS: The TRANSIT is an international registry that included cases of degenerated TAVR from 28 centers. Among around 40 000 patients treated with TAVR in the participating centers, 172 underwent a second TAVR: 57 (33%) for a mainly stenotic degenerated TAV, 97 (56%) for a mainly regurgitant TAV, and 18 (11%) for a combined degeneration. Overall, the rate of New York Heart Association class III/IV at presentation was 73.5%. RESULTS: Valve Academic Research Consortium 2 device success rate was 79%, as a consequence of residual gradient (14%) or regurgitation (7%). At 1 month, the overall mortality rate was 2.9%, while rates of new hospitalization and New York Heart Association class III/IV were 3.6% and 7%, respectively, without significant difference across the groups. At 1 year, the overall mortality rate was 10%, while rates of new hospitalization and New York Heart Association class III/IV were 7.6% and 5.8%, respectively, without significant difference across the groups. No cases of valve thrombosis were recorded. CONCLUSIONS: Selected patients with a degenerated TAV may be safely and successfully treated by means of a second TAVR. This finding is of crucial importance for the adoption of the TAVR technology in a lower risk and younger population.


Subject(s)
Aortic Valve Stenosis , Prostheses and Implants , Transcatheter Aortic Valve Replacement
SELECTION OF CITATIONS