1.
Nat Commun ; 13(1): 6053, 2022 10 13.
Article in English | MEDLINE | ID: mdl-36229438

ABSTRACT

The Omicron variant of SARS-CoV-2 became the globally dominant variant in early 2022. A sub-lineage of the Omicron variant (BA.2) was identified in England in January 2022. Here, we investigated hospitalisation and mortality risks of COVID-19 cases with the Omicron sub-lineage BA.2 (n = 258,875) compared to BA.1 (n = 984,337) in a large cohort study in England. We estimated the risk of hospital attendance, hospital admission or death using multivariable stratified proportional hazards regression models. After adjustment for confounders, BA.2 cases had lower or similar risks of death (HR = 0.80, 95% CI 0.71-0.90), hospital admission (HR = 0.88, 95% CI 0.83-0.94) and any hospital attendance (HR = 0.98, 95% CI 0.95-1.01). These findings that the risk of severe outcomes following infection with BA.2 SARS-CoV-2 was slightly lower or equivalent to the BA.1 sub-lineage can inform public health strategies in countries where BA.2 is spreading.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiology , Cohort Studies , Hospitalization , Humans , SARS-CoV-2/genetics
2.
Niger J Clin Pract ; 25(9): 1542-1547, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36149217

ABSTRACT

Background: The accurate measurement of intraocular pressure (IOP) is a fundamental basic examination in daily ophthalmic practice and is important in managing many ophthalmic diseases and conditions such as glaucoma, uveitis, and following trauma. Accurate measurement of IOP is particularly important in glaucoma because the intraocular pressure is the most important modifiable risk factor in its management. Aim: To compare intraocular pressure (IOP) measurements obtained with the Goldmann applanation (GAT) tonometer to intraocular pressure measurements obtained with the iCare rebound tonometer (RBT) and evaluate the suitability of the iCare tonometer for routine clinical use among adult patients attending a glaucoma clinic in Southwest, Nigeria. Patients and Methods: The study was a comparative cross-sectional study. A total of 132 eyes of 132 patients were recruited for the study. Three consecutive IOP measurements were obtained with each of the instruments by the same observer. A difference in IOP of ± 3 mmHg between the two instruments was considered clinically significant in this study. Results: The mean IOP measurement from GAT was 15.18 mmHg (±4.26 mmHg) and 16.32 mmHg (±4.48 mmHg) from RBT. The mean central cornea thickness was 520.66 µm (±33.34). Pearson's correlation (r = 0.84) revealed a strong statistically significant correlation between GAT and RBT measurements and paired student t-test revealed a statistically significant difference in the means of IOP obtained by the GAT and RBT. There was a tendency for RBT to yield higher IOP measurements. Conclusion: The intraocular pressure measurements obtained with iCare RBT and GAT though strongly correlated, showed statistically significant differences in the means. The impact of central cornea thickness on measurements obtained by GAT and RBT was statistically insignificant. The iCare rebound tonometer, cannot replace GAT for routine use in the glaucoma clinic.


Subject(s)
Glaucoma , Tonometry, Ocular , Adult , Cornea , Cross-Sectional Studies , Glaucoma/diagnosis , Humans , Intraocular Pressure , Manometry , Nigeria , Reproducibility of Results