Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38250764

ABSTRACT

BACKGROUND: Arteriovenous malformations (AVMs) are vascular anomalies characterized by abnormal shunting between arteries and veins. The progression of the AVMs and their hemodynamic and rheological relations are poorly studied, and there is a lack of a feasible experimental model. OBJECTIVE: To establish a model that cause only minimal micro-rheological alterations, compared to other AV models. METHODS: Sixteen female Sprague Dawley rats were randomly divided into control and AVM groups. End-to-end anastomoses were created between the saphenous veins and arteries to mimic AVM nidus. Hematological and hemorheological parameters were analyzed before surgery and on the 1st, 3rd, 5th, 7th, 9th, and 12th postoperative weeks. RESULTS: Compared to sham-operated Control group the AVM group did not show important alterations in hematological parameters nor in erythrocyte aggregation and deformability. However, slightly increased aggregation and moderately decreased deformability values were found, without significant differences. The changes normalized by the 12th postoperative week. CONCLUSIONS: The presented rat model of a small-caliber AVM created on saphenous vessels does not cause significant micro-rheological changes. The alterations found were most likely related to the acute phase reactions and not to the presence of a small-caliber shunt. The model seems to be suitable for further studies of AVM progression.

2.
Cancers (Basel) ; 15(24)2023 Dec 07.
Article in English | MEDLINE | ID: mdl-38136290

ABSTRACT

Spinal metastatic tumors are common and often cause debilitating symptoms. Image-guided percutaneous thermal ablation (IPTA) has gained significant recognition in managing spinal column tumors due to its exceptional precision and effectiveness. Conventional guidance modalities, including computed tomography, fluoroscopy, and ultrasound, have been important in targeting spinal column tumors while minimizing harm to adjacent critical structures. This study presents a novel approach utilizing a fusion of cone beam computed tomography with magnetic resonance imaging to guide percutaneous thermal ablation for four patients with secondary spinal column tumors. The visual analog scale (VAS) evaluated the procedure effectiveness during an 18-month follow-up. Percutaneous vertebroplasty was performed in two cases, and a thermostat was used during all procedures. Imaging was performed using the Stealth Station navigation system Spine 8 (SSS8) and a 1.5T MRI machine. The fusion of CBCT with MRI allowed for precise tumor localization and guidance for thermal ablation. Initial results indicate successful tumor ablation and symptom reduction, emphasizing the potential of CBCT-MRI fusion in spinal column tumor management. This innovative approach is promising in optimizing therapy for secondary spinal column tumors. Further studies are necessary to validate its efficacy and applicability.

3.
Biomedicines ; 11(11)2023 Nov 04.
Article in English | MEDLINE | ID: mdl-38001970

ABSTRACT

Arteriovenous malformation (AVM) is an anomaly of blood vessel formation. Numerous models have been established to understand the nature of AVM. These models have limitations in terms of the diameter of the vessels used and the impact on the circulatory system. Our goal was to establish an AVM model that does not cause prompt and significant hemodynamic and cardiac alterations but is feasible for follow-up of the AVM's progression. Sixteen female rats were randomly divided into sham-operated and AVM groups. In the AVM group, the saphenous vein and artery were interconnected using microsurgical techniques. The animals were followed up for 12 weeks. Anastomosis patency and the structural and hemodynamic changes of the heart were monitored. The hearts and vessels were histologically analyzed. During the follow-up period, shunts remained unobstructed. Systolic, diastolic, mean arterial pressure, and heart rate values slightly and non-significantly decreased in the AVM group. Echocardiogram results indicated minor systolic function impact, with slight and insignificant changes in aortic pressure and blood velocity, and minimal left ventricular wall enlargement. The small-caliber saphenous AVM model does not cause acute hemodynamic changes. Moderate but progressive alterations and venous dilatation confirmed AVM-like features. The model seems to be suitable for studying further the progression, enlargement, or destabilization of AVM.

4.
Diagnostics (Basel) ; 13(13)2023 Jul 03.
Article in English | MEDLINE | ID: mdl-37443649

ABSTRACT

Classifying spinal tumors can be challenging due to nonspecific clinical and radiological qualities, and a precise biopsy is crucial for an accurate diagnosis and treatment planning. This study aimed to enhance the accuracy and efficiency of spinal biopsies integrating Cone Beam Computed Tomography (CBCT) and magnetic resonance imaging (MRI) modalities using an O-arm CT navigation system. Eighteen patients with different spinal lesions underwent 18 biopsies following the Stealth Station navigation system Spine 8 protocol. Preoperative MRI scans were merged with intraoperative CT navigation systems for continuous monitoring during the biopsy process. The combined imaging technique accurately identified the diseased lesion type in all biopsies, demonstrating 100% sensitivity and specificity. In conclusion, combining MRI and CT imaging modalities significantly improved spinal biopsy accuracy and efficiency, differentiating between pathological entities. However, large-scale studies are desired to validate these findings and investigate potential benefits in different clinical scenarios. Although this method requires general anesthesia, its potential profits in avoiding misdiagnosed lesions and decreasing the need for further invasive procedures make it a promising approach for improving spinal biopsy accuracy and efficiency.

SELECTION OF CITATIONS
SEARCH DETAIL
...