Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 18(4): e0284719, 2023.
Article in English | MEDLINE | ID: mdl-37079589

ABSTRACT

BACKGROUND: Tinnitus is a common problem in patients with a cochlear implant (CI). Between 4% and 25% of CI recipients experience a moderate to severe tinnitus handicap. However, apart from handicap scores, little is known about the real-life impact tinnitus has on those with CIs. We aimed to explore the impact of tinnitus on adult CI recipients, situations impacting tinnitus, tinnitus-related difficulties and their management strategies, using an exploratory sequential mixed-method approach. METHODS: A 2-week web-based forum was conducted using Cochlear Ltd.'s online platform, Cochlear Conversation. A thematic analysis was conducted on the data from the forum discussion to develop key themes and sub-themes. To quantify themes and sub-themes identified, a survey was developed in English with face validity using cognitive interviews, then translated into French, German and Dutch and disseminated on the Cochlear Conversation platform, in six countries (Australia, France, Germany, New Zealand, the Netherlands and United Kingdom). Participants were adult CI recipients experiencing tinnitus who received a Cochlear Ltd. CI after 18 years of age. RESULTS: Four key themes were identified using thematic analysis of the discussion forum: tinnitus experience, situations impacting tinnitus, difficulties associated with tinnitus and tinnitus management. Among the 414 participants of the survey, tinnitus burden on average was a moderate problem without their sound processor and not a problem with the sound processor on. Fatigue, stress, concentration, group conversation and hearing difficulties were the most frequently reported difficulties and was reported to intensify when not wearing the sound processor. For most CI recipients, tinnitus seemed to increase when performing a hearing test, during a CI programming session, or when tired, stressed, or sick. To manage their tinnitus, participants reported turning on their sound processor and avoiding noisy environments. CONCLUSION: The qualitative analysis showed that tinnitus can affect everyday life of CI recipients in various ways and highlighted the heterogeneity in their tinnitus experiences. The survey findings extended this to show that tinnitus impact, related difficulties, and management strategies often depend on sound processor use. This exploratory sequential mixed-method study provided a better understanding of the potential benefits of sound processor use, and thus of intracochlear electrical stimulation, on the impact of tinnitus.


Subject(s)
Cochlear Implantation , Cochlear Implants , Hearing Loss , Speech Perception , Tinnitus , Adult , Humans , Speech Perception/physiology , Cochlear Implantation/methods , Hearing Loss/complications , Hearing Loss/surgery
2.
J Clin Med ; 11(19)2022 Sep 26.
Article in English | MEDLINE | ID: mdl-36233532

ABSTRACT

Patients with single-sided deafness can experience an ipsilateral disabling tinnitus that has a major impact on individuals' social communication and quality of life. Cochlear implants appear to be superior to conventional treatments to alleviate tinnitus in single-sided deafness. We conducted a systematic review to evaluate the effectiveness of cochlear implants in single-sided deafness with disabling tinnitus when conventional treatments fail to alleviate tinnitus (PROSPERO ID: CRD42022353292). All published studies in PubMed/MEDLINE and SCOPUS databases until December 2021 were included. A total of 474 records were retrieved, 31 studies were included and were divided into two categories according to whether tinnitus was assessed as a primary complaint or not. In all studies, cochlear implantation, evaluated using subjective validated tools, succeeded in reducing tinnitus significantly. Objective evaluation tools were less likely to be used but showed similar results. A short-(3 months) and long-(up to 72 months) term tinnitus suppression was reported. When the cochlear implant is disactivated, complete residual tinnitus inhibition was reported to persist up to 24 h. The results followed a similar pattern in studies where tinnitus was assesed as a primary complaint or not. In conclusion, the present review confirmed the effectiveness of cochlear implantation in sustainably reducing disabling tinnitus in single-sided deafness patients.

3.
Trends Hear ; 26: 23312165221128431, 2022.
Article in English | MEDLINE | ID: mdl-36154765

ABSTRACT

The aim of this study was to estimate the prevalence and distress of tinnitus pre- and post-cochlear implantation in patients with bilateral severe to profound hearing loss. In this retrospective study, we included patients from a cochlear implant clinic in Perth, Western Australia. Pre- and post-cochlear implantation data from 300 implant recipients were collected on self-reported presence of tinnitus, tinnitus distress using the Tinnitus Reaction Questionnaire (TRQ), hearing-related quality of life using the Abbreviated Profile of Hearing Aid Benefit (APHAB), and consonant-nucleus vowel-consonant (CNC) word recognition test scores. Retrospectively, patients were grouped into those with or without tinnitus, and the grade of tinnitus distress. The potential factors associated with post-implantation changes in the presence of tinnitus and its distress were evaluated. Tinnitus prevalence was 55.8% pre-operatively and 44.3% post-implantation with a median TRQ score respectively of 12.0 (IQR: 1.0-28.0) and 3.5 (IQR: 0.0-16.2) points. Among the 96 patients experiencing tinnitus pre-implantation, 14.6% patients experienced moderate to catastrophic tinnitus distress pre-implantation compared to 6.3% post-implantation. To conclude, the pre- and post-implantation median TRQ score for the cohort population showed that tinnitus was a "slight" handicap. Tinnitus prevalence and its associated tinnitus distress decreased post-implantation. Patients with tinnitus post-implantation were significantly younger and had less severe pre-implantation hearing loss in the non-implanted ear than patients without tinnitus. Further research is needed to understand the factors influencing changes in tinnitus.


Subject(s)
Cochlear Implantation , Cochlear Implants , Hearing Loss , Speech Perception , Tinnitus , Cochlear Implantation/adverse effects , Hearing Loss/surgery , Humans , Prevalence , Quality of Life , Retrospective Studies , Tinnitus/complications , Tinnitus/diagnosis , Tinnitus/epidemiology , Treatment Outcome
4.
Sci Rep ; 12(1): 14423, 2022 08 24.
Article in English | MEDLINE | ID: mdl-36002556

ABSTRACT

Tinnitus is a common symptom in cochlear implant (CI) recipients. There is no clear evidence of the influence of tinnitus on hearing-related quality of life (QoL) in this population. The aim of this study was to assess the relationship between hearing-related QoL measured by the Speech, Spatial and Qualities of Hearing scale (SSQ12) and tinnitus annoyance or perceived change in tinnitus annoyance after cochlear implantation. The study sample consisted of 2322 implanted adults across France, Germany, Ireland, Italy, the Netherlands, Sweden and the United Kingdom. Information relating to QoL measured using the SSQ12 and tinnitus annoyance and change in tinnitus annoyance, assessed using single-item questions, were collected one or more years post-implantation. The relationship between SSQ12 score and tinnitus annoyance or change in tinnitus annoyance was analysed using linear models adjusted for age and unilateral versus bilateral implants. Tukey pairwise tests were used to compare mean SSQ12 scores across levels of tinnitus annoyance and changes. Tinnitus prevalence was 33.9% post-implantation. Recipients with tinnitus had a significantly lower SSQ12 score than recipients without tinnitus. SSQ scores varied significantly with tinnitus annoyance, age and unilateral versus bilateral implants. Overall, CI recipients who experienced less bothersome tinnitus reported better hearing-related QoL. Healthcare professionals should be aware of the influence of tinnitus on CI recipients' hearing to manage patient expectations.


Subject(s)
Cochlear Implantation , Cochlear Implants , Speech Perception , Tinnitus , Adult , Hearing , Humans , Quality of Life , Surveys and Questionnaires , Tinnitus/etiology , Tinnitus/surgery , Treatment Outcome
5.
Brain Sci ; 11(11)2021 Oct 24.
Article in English | MEDLINE | ID: mdl-34827395

ABSTRACT

Several electrical stimulation patterns of the auditory nerve have been described for tinnitus relief, but there is no consensus on the most effective stimulation pattern. Therefore, we aim to systematically review the literature on the effect of intra- and extracochlear electrical stimulation patterns as a treatment option for patients with tinnitus. Only studies on intra- and extracochlear electrical stimulation for patients with tinnitus were included if the stimulation used did not concern standardized CI stimulation patterns to primarily rehabilitate hearing loss as intervention. A total of 34 studies met the inclusion criteria, with 10 studies (89 patients) on intracochlear electrical stimulation and 25 studies on extracochlear electrical stimulation (1109 patients). There was a high to medium risk of bias in 22 studies, especially due to lack of a non-exposed group and poor selection of the exposed group. All included studies showed subjective tinnitus improvement during or after electrical stimulation, using different stimulation patterns. Due to methodological limitations and low reporting quality of the included studies, the potential of intra- and extracochlear stimulation has not been fully explored. To draw conclusions on which stimulation patterns should be optimized for tinnitus relief, a deeper understanding of the mechanisms involved in tinnitus suppression is needed.

6.
Prog Brain Res ; 260: 27-50, 2021.
Article in English | MEDLINE | ID: mdl-33637223

ABSTRACT

BACKGROUND: Cochlear implantation (CI) is used in patients with severe-to-profound hearing loss when hearing aids provide limited or no benefit for speech perception. Studies on this topic reported tinnitus reduction as a common side effect of the electrical activation after cochlear implantation. So far, it is unclear what the effect is when patients do receive their implant primarily because of tinnitus complaints. OBJECTIVES: To assess the effectiveness of the electrical stimulation with a cochlear implant in patients with tinnitus as a primary complaint, by systematically reviewing the literature. METHODS: Two independent authors identified studies, extracted data and assessed risk of bias of included studies. Original studies reporting outcomes of electrical stimulation by cochlear implantation for primarily tinnitus (defined as severe or incapacitating distress levels) were included, if they reported a follow-up of at least three months. The pre- and post-implantation tinnitus distress scores on single and/or multi-item questionnaires of the included studies were extracted. RESULTS: In total, 4091 unique articles were retrieved. After screening titles, abstracts and full texts, we included seven prospective cohort studies (105 subjects in total, range: 10-26). All studies had considerable risks of bias. All tinnitus patients in the included studies had asymmetrical hearing loss or single-sided deafness. A statistically significant tinnitus distress improvement based on tinnitus questionnaire scores was found in every study. CONCLUSION: Our systematic review reveals that electrical stimulation by cochlear implants in patients with a primary complaint of tinnitus has a positive impact on tinnitus distress. Nevertheless, only small sample sizes were found and studies showed considerable risks of bias.a.


Subject(s)
Cochlear Implantation , Cochlear Implants , Hearing Loss, Unilateral , Tinnitus , Hearing Loss, Unilateral/surgery , Humans , Prospective Studies , Tinnitus/surgery , Tinnitus/therapy , Treatment Outcome
7.
Int J Audiol ; 60(5): 374-384, 2021 05.
Article in English | MEDLINE | ID: mdl-33074733

ABSTRACT

OBJECTIVE: Despite the positive effect of a cochlear implant (CI) on tinnitus in many patients, tinnitus remains a problem for a significant proportion of CI users. We investigated the acceptability and effect of sound therapy (a combination of natural background sounds and one concise tinnitus counselling session) on tinnitus and speech perception in CI users who still experienced tinnitus during CI use. DESIGN AND STUDY SAMPLE: Thirty-two CI users (32-78 years) participated in phase 1: a test at the clinic to evaluate six background sounds provided by the sound processor. Eighteen out of the 32 CI users participated in phase 2: an optional take-home evaluation of 2 weeks without sound therapy, followed by 5 weeks with sound therapy, ending with an evaluation visit. RESULTS: Thirty subjects (93.8%) found at least one background sound acceptable. In phase 2, a small improvement with sound therapy was found for tinnitus loudness, annoyance, and intrusiveness. 50% of the subjects subjectively reported benefit of sound therapy. Especially the sense of control on their tinnitus was highly appreciated. No detrimental effect on speech perception was observed. CONCLUSION: The background sounds were acceptable and provided tinnitus relief in some CI users with tinnitus during CI use.


Subject(s)
Cochlear Implantation , Cochlear Implants , Speech Perception , Tinnitus , Humans , Sound , Tinnitus/diagnosis , Tinnitus/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...