Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Sci Rep ; 11(1): 17315, 2021 08 27.
Article in English | MEDLINE | ID: mdl-34453096

ABSTRACT

This study was aimed to compare the vascular healing process of a SYNERGY stent with that of a PROMUS PREMIER stent in patients with acute coronary syndrome (ACS). In 71 patients with ACS, undergoing coronary stent implantation using the SYNERGY stent (n = 52) or PROMUS PREMIER stent (n = 19), we measured circulating CD34+/CD133+/CD45null cells and CD34+/KDR+ cells and observed vascular healing at the stented sites using optical coherence tomography (OCT) and coronary angioscopy. On the day 7, circulating CD34+/CD133+/CD45null cells increased in SYNERGY group (P < 0.0001), while it did not change in PROMUS group. The CD34+/KDR+ cells also increased in SYNERGY group (P < 0.0001) but less significantly in the PROMUS group (P < 0.05). The OCT-based neointimal thickness (P < 0.0005) and neointimal coverage rate (P < 0.05) at 12 months were greater in SYNERGY group, compared with PROMUS group. The coronary angioscopy-based neointimal coverage grade at 12 months was also greater in SYNERGY group (P < 0.001). In overall patients, the change in CD34+/KDR+ cells on the day 7 correlated with the OCT-based neointimal thickness at 12 months (R = 0.288, P < 0.05). SYNERGY stent seems to have potential advantages over PROMUS PREMIER stent for ACS patients in terms of vascular healing process at the stented sites.


Subject(s)
Acute Coronary Syndrome/therapy , Prosthesis Implantation/methods , Stem Cells/metabolism , Wound Healing/drug effects , Aged , Antigens, CD/metabolism , Clinical Trials as Topic , Coronary Angiography , Coronary Vessels , Female , Follow-Up Studies , Humans , Male , Middle Aged , Neointima/metabolism , Stents , Tomography, Optical Coherence , Treatment Outcome
2.
Int J Cardiovasc Imaging ; 35(11): 1971-1978, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31218524

ABSTRACT

Normalized optical density (NOD) measured by optical coherence tomography represents neointimal maturity after coronary stent implantation and is correlated with morphologic information provided by both light and electron microscopy. We aimed to test the hypothesis that even second generation drug-eluting stents (DESs) are problematic in terms of neointimal maturity. We implanted bare-metal stents (BMS: n = 14), everolimus-eluting stents (EESs: n = 15) or zotarolimus-eluting stents (ZESs: n = 12) at 41 sites in 32 patients with stable coronary artery disease. OCT was performed at up to 12 months of follow-up, and the average optical density of neointima covering struts was evaluated. NOD was calculated as the optical density of stent-strut covering tissue divided by the optical density of the struts. We also measured circulating CD34+ /CD133+ /CD45low cells, and serum levels of stromal cell-derived factor (SDF)-1, interleukin (IL)-8 and matrix metalloproteinase (MMP)-9 at baseline and follow-up. NOD was lower in the EES (0.70 ± 0.06) group than in the BMS (0.76 ± 0.07, P < 0.05) and ZES (0.76 ± 0.06, P < 0.05) groups. The mean neointimal area (R = 0.33, P < 0.05) and mean neointimal thickness (R = 0.37, P < 0.05) were correlated with NOD. Although NOD was not correlated with percent changes in circulating endothelial progenitor cells, and the levels of SDF-1 and IL-8, it was negatively correlated with the change in MMP-9 level (R = - 0.51, P < 0.01). Neointimal maturity might be lower at EES sites than BMS or ZES sites. This might lead to impaired neointimal tissue growth and matrix degradation. These results suggest a specific pathophysiology after DES implantation.


Subject(s)
Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents , Neointima , Percutaneous Coronary Intervention/instrumentation , Tomography, Optical Coherence , Aged , Aged, 80 and over , Cardiovascular Agents/administration & dosage , Chemokine CXCL12/blood , Coronary Artery Disease/blood , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Coronary Vessels/metabolism , Coronary Vessels/physiopathology , Endothelial Progenitor Cells/metabolism , Endothelial Progenitor Cells/pathology , Everolimus/administration & dosage , Female , Humans , Interleukin-8/blood , Male , Matrix Metalloproteinase 9/blood , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Prosthesis Design , Sirolimus/administration & dosage , Sirolimus/analogs & derivatives , Time Factors , Treatment Outcome , Vascular Remodeling
3.
J Am Coll Cardiol ; 70(22): 2752-2763, 2017 Dec 05.
Article in English | MEDLINE | ID: mdl-29191323

ABSTRACT

BACKGROUND: Limited data exist about safety and efficacy of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (AR). OBJECTIVES: This study sought to compare the outcomes of TAVR with early- and new-generation devices in symptomatic patients with pure native AR. METHODS: From the pure native AR TAVR multicenter registry, procedural and clinical outcomes were assessed according to VARC-2 criteria and compared between early- and new-generation devices. RESULTS: A total of 331 patients with a mean STS score of 6.7 ± 6.7 underwent TAVR. The early- and new-generation devices were used in 119 patients (36.0%) and 212 patients (64.0%), respectively. STS score tended to be lower in the new-generation device group (6.2 ± 6.7 vs. 7.6 ± 6.7; p = 0.08), but transfemoral access was more frequently used in the early-generation device group (87.4% vs. 60.8%; p < 0.001). Compared with the early-generation devices, the new-generation devices were associated with a significantly higher device success rate (81.1% vs. 61.3%; p < 0.001) due to lower rates of second valve implantation (12.7% vs. 24.4%; p = 0.007) and post-procedural AR ≥ moderate (4.2% vs. 18.8%; p < 0.001). There were no significant differences in major 30-day endpoints between the 2 groups. The cumulative rates of all-cause and cardiovascular death at 1-year follow-up were 24.1% and 15.6%, respectively. The 1-year all-cause mortality rate was significantly higher in the patients with post-procedural AR ≥ moderate compared with those with post-procedural AR ≤ mild (46.1% vs. 21.8%; log-rank p = 0.001). On multivariable analysis, post-procedural AR ≥ moderate was independently associated with 1-year all-cause mortality (hazard ratio: 2.85; 95% confidence interval: 1.52 to 5.35; p = 0.001). CONCLUSIONS: Compared with the early-generation devices, TAVR using the new-generation devices was associated with improved procedural outcomes in treating patients with pure native AR. In patients with pure native AR, significant post-procedural AR was independently associated with increased mortality.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve/surgery , Femoral Artery/surgery , Heart Valve Prosthesis , Postoperative Complications , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/surgery , Catheterization, Peripheral/methods , Catheterization, Peripheral/statistics & numerical data , Female , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis/standards , Humans , International Cooperation , Male , Mortality , Outcome and Process Assessment, Health Care , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Prosthesis Design/trends , Quality Improvement , Registries/statistics & numerical data , Risk Assessment , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/statistics & numerical data
4.
J Am Coll Cardiol ; 70(9): 1121-1131, 2017 Aug 29.
Article in English | MEDLINE | ID: mdl-28838360

ABSTRACT

BACKGROUND: Limited data exist regarding transcatheter mitral valve replacement (TMVR) for patients with failed mitral valve replacement and repair. OBJECTIVES: This study sought to evaluate the outcomes of TMVR in patients with failed mitral bioprosthetic valves (valve-in-valve [ViV]) and annuloplasty rings (valve-in-ring [ViR]). METHODS: From the TMVR multicenter registry, procedural and clinical outcomes of mitral ViV and ViR were compared according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 248 patients with mean Society of Thoracic Surgeons score of 8.9 ± 6.8% underwent TMVR. Transseptal access and the balloon-expandable valve were used in 33.1% and 89.9%, respectively. Compared with 176 patients undergoing ViV, 72 patients undergoing ViR had lower left ventricular ejection fraction (45.6 ± 17.4% vs. 55.3 ± 11.1%; p < 0.001). Overall technical and device success rates were acceptable, at 92.3% and 85.5%, respectively. However, compared with the ViV group, the ViR group had lower technical success (83.3% vs. 96.0%; p = 0.001) due to more frequent second valve implantation (11.1% vs. 2.8%; p = 0.008), and lower device success (76.4% vs. 89.2%; p = 0.009) due to more frequent reintervention (16.7% vs. 7.4%; p = 0.03). Mean mitral valve gradients were similar between groups (6.4 ± 2.3 mm Hg vs. 5.8 ± 2.7 mm Hg; p = 0.17), whereas the ViR group had more frequent post-procedural mitral regurgitation moderate or higher (19.4% vs. 6.8%; p = 0.003). Furthermore, the ViR group had more frequent life-threatening bleeding (8.3% vs. 2.3%; p = 0.03), acute kidney injury (11.1% vs. 4.0%; p = 0.03), and subsequent lower procedural success (58.3% vs. 79.5%; p = 0.001). The 1-year all-cause mortality rate was significantly higher in the ViR group compared with the ViV group (28.7% vs. 12.6%; log-rank test, p = 0.01). On multivariable analysis, failed annuloplasty ring was independently associated with all-cause mortality (hazard ratio: 2.70; 95% confidence interval: 1.34 to 5.43; p = 0.005). CONCLUSIONS: The TMVR procedure provided acceptable outcomes in high-risk patients with degenerated bioprostheses or failed annuloplasty rings, but mitral ViR was associated with higher rates of procedural complications and mid-term mortality compared with mitral ViV.


Subject(s)
Bioprosthesis/adverse effects , Cardiac Catheterization/methods , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Mitral Valve Annuloplasty/adverse effects , Mitral Valve/surgery , Aged , Europe/epidemiology , Female , Humans , Male , North America/epidemiology , Prosthesis Design , Prosthesis Failure , Reoperation , Retrospective Studies , Survival Rate/trends , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL