Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
2.
POCUS J ; 8(2): 159-164, 2023.
Article in English | MEDLINE | ID: mdl-38099176

ABSTRACT

Objectives: This pilot study aims to determine if patients untrained in performing ultrasound can self-scan to obtain images under remote clinician teleguidance during a simulated telehealth encounter. This study also seeks to describe the patients' comfort level and barriers to performing an ultrasound examination on themselves using a handheld ultrasound device. Methods: This was a single center prospective observational cohort study conducted over a 4-month period in 2021. Patients were eligible if they had no prior training in the use of ultrasound and in the use of teleguidance. They voluntarily consented to participate at a single ambulatory internal medicine clinic. Results: 20 participants were enrolled and underwent teleguidance to ultrasound their own skin and soft tissues at the antecubital fossae. Six second video clips were evaluated by 2 subject matter experts using the Point of Care Ultrasound Image Quality scale. A score >7 was considered adequate for diagnostic interpretation. The average score was 10.15/14, with a minimum score of 5/14, and maximum score of 14/14 and a standard deviation (SD) of 2.39 using a two tailed Z-score. Setting alpha at 0.05 the 95% CI was (5.47-14.83). Conclusion: In a pilot study of 20 participants with no ultrasound experience, untrained healthy volunteers were able to perform technically acceptable and interpretable ultrasound scans using teleguidance by a trained clinician.

3.
J Emerg Med ; 65(5): e403-e413, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37741738

ABSTRACT

BACKGROUND: Shoulder dislocations are among the most common orthopedic emergencies encountered in the emergency department (ED). Ultrasound-guided peripheral nerve blocks (USG-PNBs) are increasingly being used for acute pain management in the ED, but clinical evidence supporting their utility for shoulder dislocation is limited and often conflicting. OBJECTIVE: The aim of this review was to summarize and evaluate the utility of USG-PNB for analgesia during closed reduction of dislocated shoulders in the ED. METHODS: Adhering to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a systematic literature search of the PubMed, Scopus, and Cochrane databases was performed from database inception to September 2022. We included clinical studies examining USG-PNB for pain management of dislocated shoulders in the ED. Information collected from eligible studies included patient demographic characteristics, USG-PNB approach, alternate analgesia techniques, anesthetic regimens, clinical outcomes, and adverse events. RESULTS: Five studies met inclusion criteria, all of which were randomized controlled trials comparing USG-PNB with procedural sedation and analgesia. Pooled patient satisfaction scores were similar for both analgesia methods (3.5 ± 0.6 vs. 3.9 ± 0.6 out of 5; p = 0.76). Patients managed with procedural sedation and analgesia achieved higher rates of overall shoulder reduction (100% vs. 67%; p < 0.001) and successful reduction on the first attempt (86% vs. 48%; p < 0.001). The USG-PNB groups in all but one study had shorter lengths of ED stay. Overall, USG-PNB was associated with a lower risk of adverse events and complications (3.9% vs. 24.9%; p < 0.001), especially adverse respiratory events (0% vs. 14.7%; p < 0.001). CONCLUSIONS: USG-PNBs performed by adequately trained emergency physicians should be considered a safe and effective alternative for analgesia during closed reduction of dislocated shoulders in the ED, particularly in patients with cardiorespiratory comorbidities.

5.
J Vasc Access ; 24(2): 271-276, 2023 Mar.
Article in English | MEDLINE | ID: mdl-34250855

ABSTRACT

Clinicians commonly place ultrasound-guided intravenous catheters in peripheral veins for the diagnostic and therapeutic treatments of patients. This procedural skill requires practice and static phantom models are a commonly used education tool. Several commercial models that simulate blood vessels within tissue are available; however, they can be expensive. There are many examples of "Do-It-Yourself" models proposed; however, many of these require time to create the model. Mixing water and gelatin to make a gelatinous material, and the time necessary to set and store the phantom may deter people from pursuing these options. We propose Konnyaku jelly, or "yam cake," found in many Asian grocery stores, as the substrate to create a phantom model. When imaging with ultrasound, this model is similar to commercially available models, however the cost is less than $3.00 and preparation is about 5 min. We believe that Konnyaku jelly should be a more generally accepted homemade static model for phantom preparation.


Subject(s)
Catheterization , Gelatin , Humans , Cost-Benefit Analysis , Ultrasonography/methods , Phantoms, Imaging , Ultrasonography, Interventional/methods
7.
Am J Emerg Med ; 51: 285-289, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34785484

ABSTRACT

OBJECTIVES: Ultrasound (US) is an essential component of emergency department patient care. US machines have become smaller and more affordable. Handheld ultrasound (HUS) machines are even more portable and easy to use at the patient's bedside. However, miniaturization may come with consequences. The ability to accurately interpret ultrasound on a smaller screen is unknown. This pilot study aims to assess how screen size affects the ability of emergency medicine clinicians to accurately interpret US videos. METHODS: This pilot study enrolled a prospective convenience sample of emergency medicine physicians. Participants completed a survey and were randomized to interpret US videos starting with either a phone-sized screen or a laptop-sized screen, switching to the other device at the halfway point. 50 unique US videos depicting right upper quadrant (RUQ) views of the Focused Assessment with Sonography in Trauma (FAST) examination were chosen for inclusion in the study. There were 25 US videos per device. All of the images were previously obtained on a cart-based machine (Mindray M9) and preselected by the study authors. Participants answered "Yes" or "No" in response to whether they identified free fluid. The time that each participant took to interpret each video was also recorded. Following the assessment, participants completed a post-interpretation survey. The goal of the pilot was to determine the accuracy of image interpretation on a small screen as compared to a laptop-sized screen. Statistical analyses were performed using MATLAB (The MathWorks, Inc., Natick, MA). Nonparametric statistical tests were utilized to compare subgroups, with a Wilcoxon signed rank test used for paired data and a Wilcoxon rank sum test for unpaired data. RESULTS: 52 emergency medicine physicians were enrolled in the study. The median accuracy of US interpretation for phone versus laptop image screen was 88.0% and 87.6% (p = 0.67). The mean time to interpret with phone versus laptop screen was 293 and 290 s (p = 0.66). CONCLUSIONS: The study found no statistically significant difference in the accuracy of US interpretation nor time spent interpreting when the pre-selected RUQ videos generated on a cart-based ultrasound machine were reviewed on a phone-sized versus a laptop-sized screen. This pilot study suggests that the accuracy of US interpretation may not be dependent upon the size of the screen utilized.


Subject(s)
Emergency Medicine/instrumentation , Focused Assessment with Sonography for Trauma/instrumentation , Telemedicine/instrumentation , Video Recording , Wounds and Injuries/diagnostic imaging , Cell Phone , Clinical Competence , Computers , Emergency Service, Hospital , Humans , Patient Simulation , Pilot Projects , Prospective Studies
9.
AEM Educ Train ; 5(2): e10584, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33817542

ABSTRACT

BACKGROUND: Over the past two decades, studies have demonstrated that lung ultrasound is useful in diagnosing alveolar interstitial syndrome, which is seen in patients with decompensated congestive heart failure (CHF). METHODS: We studied medical students performing lung ultrasound on patients admitted to the hospital with a presumed diagnosis of decompensated CHF in a prospective convenience observation study. Two ultrasound fellowship-trained emergency medicine attendings independently reviewed the lung ultrasounds at a later date, blinded to the students' interpretation and other clinical information, to confirm ultrasound findings and assess for inter-rater reliability of the lung ultrasound using intraclass correlation coefficients (ICCs). RESULTS: Thirty-six patients were enrolled in the study resulting in 653 unique lung zones scanned. The zones were imaged and classified as being normal (B-lines < 3) or pathologic (B-lines ≥ 3). The novice scanners' interpretation was compared to expert reviews using ICCs. The ICC was 0.88, with a 95% confidence interval of 0.87 to 0.90, for all lung zones scanned. CONCLUSION: There was almost perfect agreement between novice practitioners and experts when determining the presence of pathologic B-lines in individual patients.

10.
J Vasc Access ; 22(6): 891-897, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33023394

ABSTRACT

BACKGROUND: Ultrasound (U/S) guided peripheral IV catheter (PIV) placement is often needed after unsuccessful traditional IV attempts. Commercial U/S PIV training phantoms are expensive and difficult to alter. Non-commercial phantoms have been described; however, there has been no comparison of these models. The primary objectives of this study were to compare the echogenic and haptic properties of various non-commercial phantoms. Secondary objectives were to characterize the cost and ease of making the phantoms. METHODS: This prospective observational study trialed six unique phantom models: Amini Ballistics; Morrow Ballistics; University of California San Diego (UCSD) gelatin; Rippey Chicken; Nolting Spam; and Johnson Tofu. Total cost and creation time were noted. Emergency Ultrasound Fellowship trained physicians performed U/S guided PIV placement on each model to evaluate their resemblance to human tissue haptic and echogenicity properties, utility for training, and comparability to commercial phantoms (Likert scale 1-5; higher performance = 5). RESULTS: The Rippey model scored highest for each primary objective with an aggregate score of 4.8/5. UCSD ranked second and Nolting last for all primary objectives, with aggregate scores 3.7/5 and 1.3/5 respectively. Cost of production ranged from $4.39 (Johnson) to $29.76 (UCSD). Creation times ranged from 10 min (Johnson) to 120 min (UCSD). CONCLUSION: In our study the Rippey model performed best and offered a mid-level cost and creation time. Non-commercial U/S phantoms may represent cost-effective and useful PIV practice tools. Future studies should investigate the utility of these phantoms in teaching U/S guided PIV to novices and compare non-commercial to commercial phantoms.


Subject(s)
Catheterization, Peripheral , Ultrasonography, Interventional , Catheterization, Peripheral/adverse effects , Catheters , Humans , Phantoms, Imaging , Ultrasonography
11.
J Vasc Access ; 22(5): 692-696, 2021 Sep.
Article in English | MEDLINE | ID: mdl-32962536

ABSTRACT

BACKGROUND: The optimal method for teaching ultrasound guided peripheral IV (USGPIV) insertion is unknown. Poor needle tip visualization has been cited for USGPIV failure. Twinkle artifact (TA), visualized with color Doppler, is used in other clinical settings. Our objective was to investigate whether teaching students USGPIV placement utilizing TA would enhance needle tip visualization and improve first pass success. METHODS: This was a prospective, randomized study of premedical and preclinical medical students without prior USGPIV experience. Students were given a standardized didactic session on USGPIV placement before being randomized and separated to learn and practice USGPIV with or without TA (control). The students were given 5 min to perform USGPIV on phantom models. The primary outcome was the rate of first pass success. Secondary outcomes included total time to cannulation, rate of posterior venous wall puncture, and total number of attempts. RESULTS: Rates of first pass success were similar in both the TA (82%) and control groups (57%), p = 0.095. There was a difference in the mean time to cannulation. The TA group achieved success at 50.76 s (SD 26.93) while the control group achieved success at 85.30 s (SD 65.47), p = 0.048. CONCLUSION: In this study of utilizing TA to aid in USGPIV placement, students were able to achieve successful cannulation in a shorter amount of time. There was no significant difference in first pass success. Future studies should utilize a larger sample size and evaluate the utility of TA when placing USGPIV on patients.


Subject(s)
Artifacts , Catheterization, Peripheral , Catheterization, Peripheral/adverse effects , Humans , Prospective Studies , Punctures , Ultrasonography, Interventional
14.
J Am Coll Emerg Physicians Open ; 1(5): 1101-1103, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33145564

ABSTRACT

Pulmonary ultrasound is a useful tool in the diagnosis and resuscitation of emergency department (ED) patients with dyspnea. We present the case of a patient who was diagnosed with E-cigarette or vaping product use-associated lung injury (EVALI) using pulmonary ultrasound. Many of these cases are diagnosed using x-ray, computerized tomography, or bronchoscopy and to our knowledge this is the first published case that demonstrates utility of ultrasound in diagnosing EVALI. While more investigation is needed on the use of this technique, the patient in this case was diagnosed with EVALI based on positive history, presence of normal cardiac function, non-cardiogenic pulmonary edema on ultrasound, and absence of pulmonary infection.

16.
Cureus ; 11(10): e5900, 2019 Oct 13.
Article in English | MEDLINE | ID: mdl-31763102

ABSTRACT

Introduction Interprofessional collaboration (IPC) increases patient safety. IPC is learned through task-based exercises, such as ultrasound (U/S)-guided arterial lines. We set out to teach U/S-guided arterial lines as a framework to improve IPC between emergency medicine and neurosurgery residents. The objectives of the study were to provide a U/S session to teach the proper arterial line placement technique, to assess post-workshop arterial line placement competency and attitude toward U/S for procedural guidance, and to improve interdepartmental relationships through IPC. Methods The course was completed in 2018 and consisted of pre-workshop assignments, the workshop, a competency assessment, and a post-workshop survey for neurosurgical residents. After a didactic and hands-on training session, trainees completed a simulated U/S-guided arterial line placement. Trainees then completed a post-workshop assessment. Results There were a total of 21 participants out of 24 total residents, an 87.5% participation rate. Prior to the workshop, on a 5-point Likert scale, where 1 is not at all likely and 5 is very likely, the residents reported they would use U/S 1.7/5, with 57% of respondents answering 1 out of 5. After the workshop, on the same Likert scale, the residents reported using U/S first 3.6/5 (P < 0.05) with 52% of the respondents answering 4 out of 5. After the course, the belief that the landmark technique is non-inferior decreased to 28.6% of respondents. Conclusions The overall goal of this workshop was to improve patient care through continuing education. Using IPC as the framework, the workshop significantly increased the reported likelihood of using U/S for arterial line placement.

17.
Cureus ; 11(1): e3960, 2019 Jan 25.
Article in English | MEDLINE | ID: mdl-30956912

ABSTRACT

It can be difficult to distinguish between syncope and seizure. Some stigmata of seizure include post-ictal period, tongue-biting or incontinence. A less common finding after a seizure is a posterior shoulder dislocation. Posterior shoulder dislocation is commonly missed and may be the only finding after a seizure, thus aiding in diagnosis. In this case report, we discuss the incidence of posterior shoulder dislocations and their utility in differentiating syncope from seizure, as well as the ability to diagnose and evaluate for proper reduction of posterior shoulder dislocations using ultrasound.

19.
J Ultrasound Med ; 37(11): 2667-2679, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29708268

ABSTRACT

OBJECTIVES: The purpose of this study was to conduct a systematic review of the evidence of educational outcomes associated with teaching ultrasonography (US) to medical students. METHODS: A review of databases through 2016 was conducted for research studies that reported data on teaching US to medical students. Each title and abstract were reviewed by teams of 2 independent abstractors to determine whether the article would be ordered for full-text review and subsequently by 2 independent authors for inclusion. Data were abstracted with a form developed a priori by the authors. RESULTS: Ninety-five relevant unique articles were included (of 6936 identified in the databases). Survey data showed that students enjoyed the US courses and desired more US training. Of the studies that assessed US-related knowledge and skill, most of the results were either positive (16 of 25 for knowledge and 24 of 58 for skill) or lacked a control (8 of 25 for knowledge and 27 of 58 for skill). The limited evidence (14 of 95 studies) of the effect of US training on non-US knowledge and skill (eg, anatomy knowledge or physical examination skill) was mixed. CONCLUSIONS: There is ample evidence that students can learn US knowledge and skills and that they enjoy and want US training in medical school. The evidence for the effect of US on external outcomes is limited, and there is insufficient evidence to recommend it for this purpose at this time.


Subject(s)
Clinical Competence , Curriculum , Education, Medical, Undergraduate/methods , Ultrasonics/education , Humans , Ultrasonography
20.
Cureus ; 10(11): e3536, 2018 Nov 02.
Article in English | MEDLINE | ID: mdl-30648069

ABSTRACT

Anterior shoulder dislocations are the most common, large joint dislocations that present to the emergency department (ED). Numerous studies support the use of intraarticular local anesthetic injections for the safe, effective, and time-saving reduction of these dislocations. Simulation training is an alternative and effective method for training compared to bedside learning. There are no commercially available ultrasound-compatible shoulder dislocation models. We utilized a three-dimensional (3D) printer to print a model that allows the visualization of the ultrasound anatomy (sonoanatomy) of an anterior shoulder dislocation. We utilized an open-source file of a shoulder, available from embodi3D® (Bellevue, WA, US). After approximating the relative orientation of the humerus to the glenoid fossa in an anterior dislocation, the humerus and scapula model was printed with an Ultimaker-2 Extended+ 3D® (Ultimaker, Cambridge, MA, US) printer using polylactic acid filaments. A 3D model of the external shoulder anatomy of a live human model was then created using Structure Sensor®(Occipital, San Francisco, CA, US), a 3D scanner. We aligned the printed dislocation model of the humerus and scapula within the resultant external shoulder mold. A pourable ballistics gel solution was used to create the final shoulder phantom. The use of simulation in medicine is widespread and growing, given the restrictions on work hours and a renewed focus on patient safety. The adage of "see one, do one, teach one" is being replaced by deliberate practice. Simulation allows such training to occur in a safe teaching environment. The ballistic gel and polylactic acid structure effectively reproduced the sonoanatomy of an anterior shoulder dislocation. The 3D printed model was effective for practicing an in-plane ultrasound-guided intraarticular joint injection. 3D printing is effective in producing a low-cost, ultrasound-capable model simulating an anterior shoulder dislocation. Future research will determine whether provider confidence and the use of intraarticular anesthesia for the management of shoulder dislocations will improve after utilizing this model.

SELECTION OF CITATIONS
SEARCH DETAIL