Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 68
Filter
1.
ACS Infect Dis ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38712884

ABSTRACT

This study presented the detection and quantification of capsular polysaccharide (CPS) as a biomarker for the diagnosis of melioidosis. After successfully screening four monoclonal antibodies (mAbs) previously determined to bind CPS molecules, the team developed a portable electrochemical immunosensor based on antibody-antigen interactions. The biosensor was able to detect CPS with a wide detection range from 0.1pg/mL to 1 µg/mL. The developed biosensor achieved high sensitivity for the detection of CPS spiked into both urine and serum. The developed assay platform was successfully programmed into a Windows app, and the sensor performance was evaluated with different spiked concentrations. The rapid electro-analytical device (READ) sensor showed great unprecedented sensitivity for the detection of CPS molecules in both serum and urine, and results were cross-validated with ELISA methods.

2.
J Pharm Biomed Anal ; 238: 115840, 2024 Jan 20.
Article in English | MEDLINE | ID: mdl-37956553

ABSTRACT

Recently, Mn-doped semiconductor nanocrystals (NCs) with high brightness, long lifetimes, and low-energy excitation are emerging for time-resolved luminescence biosensing/imaging. Following our previous work on Mn-doped NCs, in this work we developed poly(styrene-co-maleic anhydride) (PSMA)-encapsulated Mn-doped AgZnInS/ZnS NCs as signal transducers for immunoassay of capsular polysaccharide (CPS), a surface antigen and also a biomarker of Burkholderia pseudomallei which causes a fatal disease called melioidosis. To enhance the assay sensitivity, a surface treatment for PSMA-encapsulated NCs (NC-probes) was performed to promote the presence of carboxyl groups that help conjugate more anti-CPS antibodies to the surface of NC-probes and thus enhance bioassay signals. Meanwhile, time-resolved reading on the luminescence of NC-probes was adopted to minimize the assay background autofluorescence. Both strategies essentially enhance the assay signal-to-background ratio (or equivalently the assay sensitivity) by increasing the signal and decreasing the background, respectively. Through performing and comparing immunoassays with different NC-probes (with and without surface treatment) and different signal reading methods (time-resolved reading and non-time-resolved reading), it was proven that the immunoassay adopting surface-treated NC-probes and time-resolved reading achieved a lower limit-of-detection (LOD) than the ones adopting non-surface-treated NC-probes or non-time-resolved reading. Moreover, the achieved LOD is comparable to the LOD of immunoassay using enzyme horseradish peroxidase as a signal transducer.


Subject(s)
Nanoparticles , Quantum Dots , Reading , Nanoparticles/chemistry , Luminescence , Limit of Detection
3.
PLoS One ; 18(11): e0288713, 2023.
Article in English | MEDLINE | ID: mdl-37917669

ABSTRACT

Antibodies reactive with the SARS-CoV-2 receptor-binding domain (RBD) of the spike protein are associated with viral neutralization, however low antibody titers, specifically against SARS-CoV-2 variants, may result in reduced viral immunity post naturally acquired infection. A cohort study comprised of 121 convalescent individuals from northern Nevada was conducted looking at anti-RBD antibody levels by enzyme-linked immunosorbent assay. Serum was collected from volunteers by staff at the University of Nevada, Reno School of Medicine Clinical Research Center and assessed for antibodies reactive to various SARS-CoV-2 RBD domains relevant to the time of the study (2020-2021). A nonpaired group of vaccinated individuals were assessed in parallel. The goal of the study was to identify antibody levels against the RBD subunit in convalescent and vaccinated individuals from northern Nevada.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Cohort Studies , Nevada , Antibodies , Antibodies, Viral , Spike Glycoprotein, Coronavirus , Antibodies, Neutralizing
4.
Hum Vaccin Immunother ; 19(2): 2216085, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37289480

ABSTRACT

Yersinia pestis is a gram-negative bacterium that causes plague in animals and humans. Depending on the route of disease transmission, the bacterium can cause an acute, often fatal disease that has a narrow window for treatment with antibiotics. Additionally, antibiotic resistant strains have been identified, emphasizing the need for novel treatments. Antibody therapy is an appealing option that can direct the immune system to clear bacterial infections. Advances in biotechnology have made both engineering and producing antibodies easier and more affordable. In this study, two screening assays were optimized to evaluate the ability of antibodies to promote phagocytosis of Y. pestis by macrophages and to induce a cytokine signature in vitro that may be predictive of protection in vivo. We evaluated a panel of 21 mouse monoclonal antibodies targeting either the anti-phagocytic capsule F1 protein or the LcrV antigen, which is part of the type 3 secretion system that facilitates translocation of virulence factors into the host cell, using two functional assays. Anti-F1 and anti-LcrV monoclonal antibodies both increased bacterial uptake by macrophages, with greater uptake observed in the presence of antibodies that were protective in the mouse pneumonic plague model. In addition, the protective anti-F1 and anti-LcrV antibodies produced unique cytokine signatures that were also associated with in vivo protection. These antibody-dependent characteristics from in vitro functional assays will be useful in down-selecting efficacious novel antibodies that can be used for treatment of plague.


Subject(s)
Plague Vaccine , Plague , Yersinia pestis , Mice , Humans , Animals , Antibodies, Monoclonal/therapeutic use , Antigens, Bacterial , Antibodies, Bacterial , Cytokines , Pore Forming Cytotoxic Proteins
5.
Anal Methods ; 15(15): 1870-1880, 2023 04 13.
Article in English | MEDLINE | ID: mdl-36975002

ABSTRACT

We report clear proof-of-principle for centrifugally-driven, multiplexed, paper-based orthogonal flow sandwich-style immunocapture (cOFI) and colorimetric detection of Zaire Ebola virus-like particles. Capture antibodies are immobilized onto nanoporous nitrocellulose membranes that are then laminated into polymeric microfluidic discs to yield ready-to-use analytical devices. Fluid flow is controlled solely by rotational speed, obviating the need for complex pneumatic pumping systems, and providing more precise flow control than with the capillary-driven flow used in traditional lateral flow immunoassays (LFIs). Samples containing the antigen of interest and gold nanoparticle-labeled detection antibodies are pumped centrifugally through the embedded, prefunctionalized membrane where they are subsequently captured to generate a positive, colorimetric signal. When compared to the equivalent LFI counterparts, this cOFI approach generated immunochromatographic colorimetric responses that are objectively darker (saturation), more intense (grayscale), and less variable regarding total area of the color response. We also describe an image analysis approach that enables access to rich color data and area statistics without the need for a commercial 'strip reader' or custom-written image analysis algorithms. Instead, our analytical method exploits inexpensive equipment (e.g., smart phone, flatbed scanner, etc.) and freely available software (Fiji distribution of ImageJ) to permit characterization of immunochromatographic responses that includes multiple color metrics, offering insights beyond typical grayscale analysis. The findings reported here stand as clear proof-of-principle for the feasibility of disc-based, centrifugally driven orthogonal flow through a membrane with immunocapture (cOFI) and colorimetric readout of a sandwich-type immunoassay in less than 15 minutes. Once fully developed, this cOFI platform could render a faster, more accurate diagnosis, while processing multiple samples simul-taneously.


Subject(s)
Ebolavirus , Metal Nanoparticles , Microfluidics , Metal Nanoparticles/chemistry , Gold/chemistry , Immunoassay/methods , Antibodies
6.
Biosens Bioelectron ; 219: 114796, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36257115

ABSTRACT

This paper presents simple, fast, and sensitive detection of multiple biothreat agents by paper-based vertical flow colorimetric sandwich immunoassay for detection of Yersinia pestis (LcrV and F1) and Francisella tularensis (lipopolysaccharide; LPS) antigens using a vertical flow immunoassay (VFI) prototype with portable syringe pump and a new membrane holder. The capture antibody (cAb) printing onto nitrocellulose membrane and gold-labelled detection antibody (dAb) were optimized to enhance the assay sensitivity and specificity. Even though the paper pore size was relaxed from previous 0.1 µm to the current 0.45 µm for serum samples, detection limits as low as 0.050 ng/mL for LcrV and F1, and 0.100 ng/mL for FtLPS have been achieved in buffer and similarly in diluted serum (with LcrV and F1 LODs remained the same and LPS LOD reduced to 0.250 ng/mL). These were 40, 80, and 50X (20X for LPS in serum) better than those from lateral flow configuration. Furthermore, the comparison of multiplex format demonstrated low cross-reactivity and equal sensitivity to that of the singleplex assay. The optimized VFI platform thus provides a portable and rapid on-site monitoring system for multiplex biothreat detection with the potential for high sensitivity, specificity, reproducibility, and multiplexing capability, supporting its utility in remote and resource-limited settings.

7.
Viruses ; 14(12)2022 11 23.
Article in English | MEDLINE | ID: mdl-36560613

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the virus responsible for the COVID-19 pandemic. From the onset of the pandemic, rapid antigen tests have quickly proved themselves to be an accurate and accessible diagnostic platform. The initial (and still most commonly used antigen tests) for COVID-19 diagnosis were constructed using monoclonal antibodies (mAbs) specific to severe acute respiratory syndrome coronavirus (SARS-CoV) nucleocapsid protein (NP). These mAbs are able to bind SARS-CoV-2 NP due to high homology between the two viruses. However, since first being identified in 2019, SARS-CoV-2 has continuously mutated, and a multitude of variants have appeared. These mutations have an elevated risk of leading to possible diagnostic escape when using tests produced with SARS-CoV-derived mAbs. Here, we established a library of 18 mAbs specific to SARS-CoV-2 NP and used two of these mAbs (1CV7 and 1CV14) to generate a prototype antigen-detection lateral flow immunoassay (LFI). A side-by-side analysis of the 1CV7/1CV14 LFI and the commercially available BinaxNOWTM COVID-19 Antigen CARD was performed. Results indicated the 1CV7/1CV14 LFI outperformed the BinaxNOWTM test in the detection of BA.2, BA.2.12.1, and BA.5 Omicron sub-variants when testing remnant RT-PCR positive patient nasopharyngeal swabs diluted in viral transport media.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2/genetics , COVID-19 Testing , Pandemics , Sensitivity and Specificity , Immunoassay/methods , Antigens , Antibodies, Monoclonal
8.
ACS Omega ; 7(36): 32262-32271, 2022 Sep 13.
Article in English | MEDLINE | ID: mdl-36120062

ABSTRACT

Antibody microarrays have proven useful in immunoassay-based point-of-care diagnostics for infectious diseases. Noncontact piezoelectric inkjet printing has advantages to print antibody microarrays on nitrocellulose substrates for this application due to its compatibility with sensitive solutions and substrates, simple droplet control, and potential for high-capacity printing. However, there remain real-world challenges in printing such microarrays, which motivated this study. The effects of three concentrations of capture antibody (cAb) reagents and nozzle hydrostatic pressures were chosen to investigate three responses: the number of printed membrane disks, dispensing performance, and microarray quality. Printing conditions were found to be most ideal with 5 mg/mL cAb and a nozzle hydrostatic pressure near zero, which produced 130 membrane disks in a single print versus the 10 membrane disks per print before optimization. These results serve to inform efficient printing of antibody microarrays on nitrocellulose membranes for rapid immunoassay-based detection of infectious diseases and beyond.

9.
JAMA Netw Open ; 5(8): e2228143, 2022 08 01.
Article in English | MEDLINE | ID: mdl-36001317

ABSTRACT

Importance: Variants of SARS-CoV-2 have sequence variations in the viral genome that may alter the accuracy of rapid diagnostic tests. Objective: To assess the analytical and clinical accuracy of 2 rapid diagnostic tests for detecting SARS-CoV-2 during 3 phases of variants. Design, Setting, and Participants: This diagnostic study included participants aged 18 years or older who reported onset of COVID-19-like symptoms within the prior 5 days and were tested at multiple COVID-19 testing locations in King County, Washington, from February 17, 2021, to January 11, 2022, during 3 distinct phases of SARS-CoV-2 infection (pre-Delta, Delta, and Omicron). Interventions: Two anterior nasal swab specimens were collected from each participant-1 for onsite testing by the SCoV-2 Ag Detect Rapid Self-Test and 1 for reverse transcriptase-polymerase chain reaction (RT-PCR) testing. Main Outcomes and Measures: The analytical limit of detection of the 2 rapid diagnostic tests (SCoV-2 Ag Detect Rapid Self-Test and BinaxNOW COVID-19 Ag Card) was assessed using Omicron (B.1.1.529/BA.1), Delta (B.1.617.2), and a wild-type (USA-WA1/2020) variant. Diagnostic sensitivity and specificity of clinical testing for the rapid antigen tests were compared with that of RT-PCR testing. Results: A total of 802 participants were enrolled (mean [SD] age, 37.3 [13.3] years; 467 [58.2%] female), 424 (52.9%) of whom had not received COVID-19 vaccination and presented a median of 2 days (IQR, 1-3 days) from symptom onset. Overall, no significant differences were found in the analytical limit of detection or clinical diagnostic accuracy of rapid antigen testing across SARS-CoV-2 variants. The estimated limit of detection for both rapid nucleocapsid antigen tests was at or below a 50% tissue culture infectious dose of 62.5, and the positive percent agreement of the SCoV-2 Ag Detect Rapid Self-Test ranged from 81.2% (95% CI, 69.5%-89.9%) to 90.7% (95% CI, 77.9%-97.4%) across the 3 phases of variants. The diagnostic sensitivity increased for nasal swabs with a lower cycle threshold by RT-PCR, which correlates with a higher viral load. Conclusions and Relevance: In this diagnostic study, analytical and clinical performance data demonstrated accuracy of 2 rapid antigen tests among adults with COVID-19 symptoms across 3 phases of SARS-CoV-2 variants. The findings suggest that home-based rapid antigen testing programs may be an important intervention to reduce global SARS-CoV-2 transmission.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , COVID-19/diagnosis , COVID-19 Testing , COVID-19 Vaccines , Female , Humans , Male , SARS-CoV-2/genetics
10.
Microbiol Spectr ; 10(4): e0076522, 2022 08 31.
Article in English | MEDLINE | ID: mdl-35924843

ABSTRACT

Burkholderia pseudomallei is the causative agent of melioidosis, a life-threatening disease common in Southeast Asia and northern Australia. Melioidosis often presents with nonspecific symptoms and has a fatality rate of upwards of 70% when left untreated. The gold standard for diagnosis is culturing B. pseudomallei from patient samples. Bacterial culture, however, can take up to 7 days, and its sensitivity is poor, at roughly 60%. The successful administration of appropriate antibiotics is reliant on rapid and accurate diagnosis. Hence, there is a genuine need for new diagnostics for this deadly pathogen. The Active Melioidosis Detect (AMD) lateral flow immunoassay (LFI) detects the capsular polysaccharide (CPS) of B. pseudomallei. The assay is designed for use on various clinical samples, including serum and urine; however, there are limited data to support which clinical matrices are the best candidates for detecting CPS. In this study, concentrations of CPS in paired serum and urine samples from melioidosis patients were determined using a quantitative antigen capture enzyme-linked immunosorbent assay. In parallel, samples were tested with the AMD LFI, and the results of the two immunoassays were compared. Additionally, centrifugal concentration was performed on a subset of urine samples to determine if this method may improve detection when CPS levels are initially low or undetectable. The results indicate that while CPS levels varied within the two matrices, there tended to be higher concentrations in urine. The AMD LFI detected CPS in 40.5% of urine samples, compared to 6.5% of serum samples, suggesting that urine is a preferable matrix for point-of-care diagnostic assays. IMPORTANCE Melioidosis is very challenging to diagnose. There is a clear need for a point-of-care assay for the detection of B. pseudomallei antigen directly from patient samples. The Active Melioidosis Detect lateral flow immunoassay detects the capsular polysaccharide (CPS) of B. pseudomallei and is designed for use on various clinical samples, including serum and urine. However, there are limited data regarding which clinical matrix is preferable for the detection of CPS. This study addresses this question by examining quantitative CPS levels in paired serum and urine samples and relating them to clinical parameters. Additionally, centrifugal concentration was performed on a subset of urine samples to determine whether this might enable the detection of CPS in samples in which it was initially present at low or undetectable levels. These results provide valuable insights into the detection of CPS in patients with melioidosis and suggest potential ways forward in the diagnosis and treatment of this challenging disease.


Subject(s)
Burkholderia pseudomallei , Melioidosis , Humans , Immunoassay/methods , Melioidosis/diagnosis , Melioidosis/microbiology , Polysaccharides , Sensitivity and Specificity
11.
Appl Environ Microbiol ; 88(12): e0060022, 2022 06 28.
Article in English | MEDLINE | ID: mdl-35652663

ABSTRACT

Burkholderia pseudomallei is a Gram-negative soil saprophyte with the potential to cause melioidosis, an opportunistic disease with a high mortality potential. Periodic case reports of melioidosis in or imported from Africa occur in the literature dating back decades. Furthermore, statistical models suggest Western sub-Saharan Africa as a high-risk zone for the presence of B. pseudomallei. A recent case report from the United Kingdom of a returning traveler from Ghana highlights the need for environmental studies in Ghana. We examined 100 soil samples from a rice farm in south-central Ghana. Soil was subjected to selective enrichment culture for B. pseudomallei using threonine-basal salt solution with colistin (TBSS-C50) and erythritol medium, as described in the literature. Bacterial cultures were identified with standard biochemical tests, a rapid antigen detection assay, and real-time PCR specific for B. pseudomallei. Of the 100 soil samples, 55% yielded cultures consistent with B. pseudomallei on Ashdown's agar as well as by capsular polysaccharide antigen production. This is the first confirmatory report of culture-confirmed B. pseudomallei in the environment of Ghana. Our study emphasizes the need for further exploration of the burden of human melioidosis in Ghana. We recommend that local clinicians familiarize themselves with the diagnosis and clinical management of melioidosis, while laboratories develop capacity for the safe isolation and identification of B. pseudomallei. IMPORTANCE We present the first confirmation of the presence of B. pseudomallei in the environment of Ghana. This study will bring attention to a disease with the potential to cause significant morbidity and mortality in Ghana, but which has gone completely unrecognized until this point. Furthermore, this work would encourage local clinicians to familiarize themselves with the diagnosis and clinical management of melioidosis and laboratories to develop capacity for the safe isolation and identification of B. pseudomallei.


Subject(s)
Burkholderia pseudomallei , Melioidosis , Burkholderia pseudomallei/genetics , Ghana , Humans , Melioidosis/diagnosis , Melioidosis/microbiology , Soil , Soil Microbiology
12.
IEEE Sens Lett ; 6(4)2022 Apr.
Article in English | MEDLINE | ID: mdl-35496896

ABSTRACT

Time-resolved fluorescence measurement, a technique utilized to improve sensitivity for fluorescence detection, is becoming more accessible due to the recent development of bright nanolabels with long fluorescence lifetimes and low-energy excitation. Currently, instruments taking advantage of this technique for broader applications (in-field or point-of-care testing) are lagging behind in their development. In this work, a low-cost, compact, and sensitive time-resolved-optical-reader was developed aiming to advance such a technique for wider applications.

13.
Micromachines (Basel) ; 13(3)2022 Mar 20.
Article in English | MEDLINE | ID: mdl-35334778

ABSTRACT

To bring to bear the power of centrifugal microfluidics on vertical flow immunoassays, control of flow orthogonally through nanoporous membranes is essential. The on-disc approach described here leverages the rapid print-cut-laminate (PCL) disc fabrication and prototyping method to create a permanent seal between disc materials and embedded nanoporous membranes. Rotational forces drive fluid flow, replacing capillary action, and complex pneumatic pumping systems. Adjacent microfluidic features form a flow path that directs fluid orthogonally (vertically) through these embedded membranes during assay execution. This method for membrane incorporation circumvents the need for solvents (e.g., acetone) to create the membrane-disc bond and sidesteps issues related to undesirable bypass flow. In other recently published work, we described an orthogonal flow (OF) platform that exploited embedded membranes for automation of enzyme-linked immunosorbent assays (ELISAs). Here, we more fully characterize flow patterns and cellulosic membrane behavior within the centrifugal orthogonal flow (cOF) format. Specifically, high-speed videography studies demonstrate that sample volume, membrane pore size, and ionic composition of the sample matrix significantly impact membrane behavior, and consequently fluid drainage profiles, especially when cellulosic membranes are used. Finally, prototype discs are used to demonstrate proof-of-principle for sandwich-type antigen capture and immunodetection within the cOF system.

14.
PLoS Negl Trop Dis ; 16(3): e0010287, 2022 03.
Article in English | MEDLINE | ID: mdl-35320275

ABSTRACT

BACKGROUND: Yersinia pestis is the causative agent of plague, a zoonosis associated with small mammals. Plague is a severe disease, especially in the pneumonic and septicemic forms, where fatality rates approach 100% if left untreated. The bacterium is primarily transmitted via flea bite or through direct contact with an infected host. The 2017 plague outbreak in Madagascar resulted in more than 2,400 cases and was highlighted by an increased number of pneumonic infections. Standard diagnostics for plague include laboratory-based assays such as bacterial culture and serology, which are inadequate for administering immediate patient care for pneumonic and septicemic plague. PRINCIPAL FINDINGS: The goal of this study was to develop a sensitive rapid plague prototype that can detect all virulent strains of Y. pestis. Monoclonal antibodies (mAbs) were produced against two Y. pestis antigens, low-calcium response V (LcrV) and capsular fraction-1 (F1), and prototype lateral flow immunoassays (LFI) and enzyme-linked immunosorbent assays (ELISA) were constructed. The LFIs developed for the detection of LcrV and F1 had limits of detection (LOD) of roughly 1-2 ng/mL in surrogate clinical samples (antigens spiked into normal human sera). The optimized antigen-capture ELISAs produced LODs of 74 pg/mL for LcrV and 61 pg/mL for F1 when these antigens were spiked into buffer. A dual antigen LFI prototype comprised of two test lines was evaluated for the detection of both antigens in Y. pestis lysates. The dual format was also evaluated for specificity using a small panel of clinical near-neighbors and other Tier 1 bacterial Select Agents. CONCLUSIONS: LcrV is expressed by all virulent Y. pestis strains, but homologs produced by other Yersinia species can confound assay specificity. F1 is specific to Y. pestis but is not expressed by all virulent strains. Utilizing highly reactive mAbs, a dual-antigen detection (multiplexed) LFI was developed to capitalize on the diagnostic strengths of each target.


Subject(s)
Plague , Yersinia pestis , Animals , Antibodies, Bacterial , Antigens, Bacterial , Humans , Immunoassay/methods , Mammals , Plague/microbiology , Yersinia pestis/physiology , Zoonoses
15.
J Pharmacol Exp Ther ; 381(2): 129-136, 2022 05.
Article in English | MEDLINE | ID: mdl-35153198

ABSTRACT

The incidence of fatal drug overdoses in the United States is an alarming public health threat that has been exacerbated by the COVID-19 pandemic, resulting in over 100,000 deaths between April 2020 and April 2021. A significant portion of this is attributable to widespread access to fentanyl and other synthetic opioids, alone or in combination with heroin or psychostimulants, such as cocaine or methamphetamine. Monoclonal antibodies (mAb) offer prophylactic and therapeutic interventions against opioid overdose by binding opioids in serum, reducing distribution of drug to the brain and other organs. Here, we investigated the efficacy of a leading antifentanyl mAb, clone HY6-F9, in reversal and prevention of fentanyl-induced toxicity compared with the opioid receptor antagonist naloxone (NLX) in rats. In postexposure models, rats were challenged with fentanyl, followed by HY6-F9, NLX, or both. HY6-F9 reversed fentanyl-induced antinociception, respiratory depression, and bradycardia, and rats retained protection against additional challenges for at least 1 week. Although intravenous NLX reversed fentanyl-induced respiratory depression more rapidly than mAb alone, kinetics of reversal by intravenous mAb were similar to subcutaneous NLX. Coadministration of mAb and NLX provided greater protection than individual treatments against high doses of fentanyl. Prophylactic administration of mAb reduced the ED50 of NLX approximately twofold against 2.25 mg/kg of fentanyl. Finally, mAb sequestered fentanyl and its metabolite norfentanyl in serum and reduced brain concentrations of fentanyl. These results support the translation of mAb as medical interventions alone or in combination with NLX to prevent and reverse fentanyl-related overdose. SIGNIFICANCE STATEMENT: Fentanyl-related overdoses have increased dramatically in the US and worldwide. Currently, approved pharmacotherapies for treatment of opioid use disorder and reversal of overdose are not sufficient to curb the incidence of opioid-related deaths. Additionally, fentanyl and its potent analogs present a potential risk from use in deliberate poisoning or chemical attacks. This study demonstrates the use of monoclonal antibodies as a countermeasure to fentanyl-induced toxicity in pre- and postexposure scenarios, supporting their use in combination with the opioid antagonist naloxone.


Subject(s)
COVID-19 , Drug Overdose , Respiratory Insufficiency , Analgesics, Opioid/therapeutic use , Animals , Antibodies, Monoclonal/pharmacology , Antibodies, Monoclonal/therapeutic use , Drug Overdose/drug therapy , Fentanyl , Humans , Naloxone/pharmacology , Naloxone/therapeutic use , Narcotic Antagonists/pharmacology , Pandemics , Rats , Respiratory Insufficiency/drug therapy
16.
PLoS Negl Trop Dis ; 15(11): e0009840, 2021 11.
Article in English | MEDLINE | ID: mdl-34727111

ABSTRACT

BACKGROUND: Melioidosis, an infectious disease caused by Burkholderia pseudomallei, is endemic in many tropical developing countries and has a high mortality. Here we evaluated combinations of a lateral flow immunoassay (LFI) detecting B. pseudomallei capsular polysaccharide (CPS) and enzyme-linked immunosorbent assays (ELISA) detecting antibodies against hemolysin co-regulated protein (Hcp1) or O-polysaccharide (OPS) for diagnosing melioidosis. METHODOLOGY/PRINCIPAL FINDINGS: We conducted a cohort-based case-control study. Both cases and controls were derived from a prospective observational study of patients presenting with community-acquired infections and sepsis in northeast Thailand (Ubon-sepsis). Cases included 192 patients with a clinical specimen culture positive for B. pseudomallei. Controls included 502 patients who were blood culture positive for Staphylococcus aureus, Escherichia coli or Klebsiella pneumoniae or were polymerase chain reaction assay positive for malaria or dengue. Serum samples collected within 24 hours of admission were stored and tested using a CPS-LFI, Hcp1-ELISA and OPS-ELISA. When assessing diagnostic tests in combination, results were considered positive if either test was positive. We selected ELISA cut-offs corresponding to a specificity of 95%. Using a positive cut-off OD of 2.912 for Hcp1-ELISA, the combination of the CPS-LFI and Hcp1-ELISA had a sensitivity of 67.7% (130/192 case patients) and a specificity of 95.0% (477/502 control patients). The sensitivity of the combination (67.7%) was higher than that of the CPS-LFI alone (31.3%, p<0.001) and that of Hcp1-ELISA alone (53.6%, p<0.001). A similar phenomenon was also observed for the combination of CPS-LFI and OPS-ELISA. In case patients, positivity of the CPS-LFI was associated with a short duration of symptoms, high modified Sequential (sepsis-related) Organ Failure Assessment (SOFA) score, bacteraemia and mortality outcome, while positivity of Hcp1-ELISA was associated with a longer duration of symptoms, low modified SOFA score, non-bacteraemia and survival outcome. CONCLUSIONS/SIGNIFICANCE: A combination of antigen-antibody diagnostic tests increased the sensitivity of melioidosis diagnosis over individual tests while preserving high specificity. Point-of-care tests for melioidosis based on the use of combination assays should be further developed and evaluated.


Subject(s)
Antibodies, Bacterial/analysis , Antigens, Bacterial/analysis , Diagnostic Tests, Routine/methods , Enzyme-Linked Immunosorbent Assay/methods , Melioidosis/diagnosis , Antibodies, Bacterial/immunology , Antigens, Bacterial/immunology , Burkholderia pseudomallei/immunology , Burkholderia pseudomallei/isolation & purification , Case-Control Studies , Humans , Melioidosis/microbiology , Prospective Studies
17.
Pathogens ; 10(8)2021 Jul 22.
Article in English | MEDLINE | ID: mdl-34451388

ABSTRACT

Francisella tularensis is the causative agent of tularemia, a zoonotic bacterial infection that is often fatal if not diagnosed and treated promptly. Natural infection in humans is relatively rare, yet persistence in animal reservoirs, arthropod vectors, and water sources combined with a low level of clinical recognition make tularemia a serious potential threat to public health in endemic areas. F. tularensis has also garnered attention as a potential bioterror threat, as widespread dissemination could have devastating consequences on a population. A low infectious dose combined with a wide range of symptoms and a short incubation period makes timely diagnosis of tularemia difficult. Current diagnostic techniques include bacterial culture of patient samples, PCR and serological assays; however, these techniques are time consuming and require technical expertise that may not be available at the point of care. In the event of an outbreak or exposure a more efficient diagnostic platform is needed. The lipopolysaccharide (LPS) component of the bacterial outer leaflet has been identified previously by our group as a potential diagnostic target. For this study, a library of ten monoclonal antibodies specific to F. tularensis LPS were produced and confirmed to be reactive with LPS from type A and type B strains. Antibody pairs were tested in an antigen-capture enzyme-linked immunosorbent assay (ELISA) and lateral flow immunoassay format to select the most sensitive pairings. The antigen-capture ELISA was then used to detect and quantify LPS in serum samples from tularemia patients for the first time to determine the viability of this molecule as a diagnostic target. In parallel, prototype lateral flow immunoassays were developed, and reactivity was assessed, demonstrating the potential utility of this assay as a rapid point-of-care test for diagnosis of tularemia.

18.
Anal Chem ; 93(27): 9337-9344, 2021 07 13.
Article in English | MEDLINE | ID: mdl-33989499

ABSTRACT

Yersinia pestis is a Gram-negative bacterium that is the causative agent of plague and is widely recognized as a potential biological weapon. Due to the high fatality rate of plague when diagnosis is delayed, the development of rapid, sensitive, specific, and cost-effective methods is needed for its diagnosis. The Y. pestis low calcium response V (LcrV) protein has been identified as a potential microbial biomarker for the diagnosis of plague. In this paper, we present a highly sensitive, paper-based, vertical flow immunoassay (VFI) prototype for the detection of LcrV and the diagnosis of plague. An antigen-capture assay using monoclonal antibodies is employed to capture and detect the LcrV protein, using a colorimetric approach. In addition, the effect of miniaturizing the VFI device is explored based on two different sizes of VFI platforms, denoted as "large VFI" and "mini VFI." Also, a comparative analysis is performed between the VFI platform and a lateral flow immunoassay (LFI) platform to exhibit the improved assay sensitivity suitable for point-of-care (POC) diagnostics. The analytical sensitivity or limit of detection (LOD) in the mini VFI is approximately 0.025 ng/mL, that is, 10 times better than that of the large VFI platform or 80 times over a standard lateral flow configuration. The low LOD of the LcrV VFI appears to be highly suitable for testing clinical samples and potentially diagnosing plague at earlier time points. In addition, optimization of the gold nanoparticle (AuNP) concentration, nanomaterial plasmonic properties, and flow velocity analysis could improve the performance of the VFI. Furthermore, we developed automated image analysis software that shows potential for integrating the diagnostic system into a smartphone. These methods and findings demonstrate that the VFI platform is a highly sensitive device for detecting the LcrV and potentially many other biomarkers.


Subject(s)
Metal Nanoparticles , Plague , Yersinia pestis , Antibodies, Bacterial , Antigens, Bacterial , Gold , Humans , Immunoassay , Plague/diagnosis
19.
Front Phys ; 82021 Jan.
Article in English | MEDLINE | ID: mdl-33816457

ABSTRACT

In this work, a time-gated immunoassay platform using low-energy excitable and fluorescence long-lived Mn:AgZnInS/ZnS nanocrystals as signal transducers was developed and applied to the detection of the capsular polysaccharide (CPS) of Burkholderia pseudomallei, a Gram-negative bacterium that is the causative agent of melioidosis. CPS is a high molecular weight antigen displayed and is shed from the outer membrane of B. pseudomallei. The immunoassay using the time-gated platform presents a limit of detection at around 23 pg/ml when CPS is spiked in human serum.

20.
J Genet Genomics ; 48(1): 40-51, 2021 01 20.
Article in English | MEDLINE | ID: mdl-33820739

ABSTRACT

Patients with signs of COVID-19 were tested through diagnostic RT-PCR for SARS-CoV-2 using RNA extracted from the nasopharyngeal/nasal swabs. To determine the variants of SARS-CoV-2 circulating in the state of Nevada, specimens from 200 COVID-19 patients were sequenced through our robust sequencing platform, which enabled sequencing of SARS-CoV-2 from specimens with even very low viral loads, without the need of culture-based amplification. High genome coverage allowed the identification of single and multi-nucleotide variants in SARS-CoV-2 in the community and their phylogenetic relationships with other variants present during the same period of the outbreak. We report the occurrence of a novel mutation at 323aa (314aa of orf1b) of nsp12 (RNA-dependent RNA polymerase) changed to phenylalanine (F) from proline (P), in the first reported isolate of SARS-CoV-2, Wuhan-Hu-1. This 323F variant was present at a very high frequency in Northern Nevada. Structural modeling determined this mutation in the interface domain, which is important for the association of accessory proteins required for the polymerase. In conclusion, we report the introduction of specific SARS-CoV-2 variants at very high frequency in distinct geographic locations, which is important for understanding the evolution and circulation of SARS-CoV-2 variants of public health importance, while it circulates in humans.


Subject(s)
COVID-19/virology , Coronavirus RNA-Dependent RNA Polymerase/genetics , SARS-CoV-2/genetics , COVID-19/epidemiology , Coronavirus RNA-Dependent RNA Polymerase/chemistry , Genome, Viral/genetics , Humans , Models, Molecular , Mutation , Nasopharynx/virology , Nevada/epidemiology , Phylogeny , Prevalence , RNA, Viral/genetics , SARS-CoV-2/isolation & purification , Spike Glycoprotein, Coronavirus/genetics , Workflow
SELECTION OF CITATIONS
SEARCH DETAIL
...