1.
Cornea ; 2024 Jul 30.
Article in English | MEDLINE | ID: mdl-39079755

ABSTRACT

PURPOSE: High-order aberrations (HOAs) are known to be increased in corneas with Fuchs endothelial dystrophy (FECD) and are associated with visual impairment. This case series aimed to analyze whether tomographic changes in FECD affect the HOA in the early period of the disease. METHODS: In this retrospective single-center case series, 144 eyes of 85 patients were included, of which 78 eyes of 47 patients with FECD with slit-lamp biomicroscopically visible guttae but no visible corneal edema served as the study-cohort. According to Sun et al, included eyes were divided into 2 groups: group 0 (n = 28; no subclinical corneal edema) and group 1 (n = 50; subclinical corneal edema). A total of 66 healthy eyes of 38 patients served as control group. Mean values and standard deviations were calculated for the root mean square (RMS), coma, trefoil and spherical aberrations (SA) of the cornea (C), the anterior surface (CF), and the posterior surface (CB). RESULTS: Statistically significant differences (P < 0.001) in the RMS HOA (group 0: 0.209 ± 0.044 µm, group 1: 0.372 ± 0.122 µm) and in coma (group 0: 0.082 ± 0.054 µm, group 1: 0.214 ± 0.101 µm) and SA (group 0: -0.130 ± 0.038 µm, group 1: -0.176 ± 0.074 µm) of the CB were found in eyes in group 1 versus those in group 0. There were no statistically significant differences in HOA between the control group and eyes in group 0. CONCLUSIONS: FECD eyes with subclinical corneal edema demonstrated significant increase in RMS, coma, and SA of the CB. Tomographic analysis, therefore, helps in visual impairment assessment, disease progression, and decision-making for early endothelial keratoplasty in patients with FECD.

2.
Ophthalmologie ; 2024 Jul 17.
Article in German | MEDLINE | ID: mdl-39017699

ABSTRACT

A multitude of available intraocular lens (IOL) models enable a personalized approach to presbyopia correction in order to meet each patient's needs. This review article discusses more complex approaches which can be useful in selected cases. The concept of reversible trifocality enables correction of presbyopia using a supplementary intraocular lens (IOL), which can be removed if necessary (e.g., intolerance to multifocal optics). The use of capsulotomy-fixated IOLs enables high precision for positioning of the lens and better stability compared to conventional capsular bag-fixated IOLs, which can be particularly advantageous in multifocal optics. The mix and match concept enables a combination of different IOLs with various optical principles to achieve the desired binocular effect. Binocular IOL systems, which consist of two complementary IOLs, can be seen as a further development of the mix and match concept. Knowledge of the available options and their application can further improve correction of presbyopia.

3.
Ophthalmologie ; 2024 Jul 08.
Article in German | MEDLINE | ID: mdl-38977490

ABSTRACT

Intraocular lenses (IOL) featuring complex optical designs can pose a challenge in understanding their performance, which may hinder making an informed decision when selecting suitable lenses for patients. This underlines the importance of collecting optical quality data of IOLs and making them available. The deployment of benchtop systems for IOL testing offers not only insights into the design features of various IOL solutions but also provides a platform for objective comparisons of special optics designs, including information about their susceptibility to photic phenomena. Recent advances in IOL testing have improved the ability to predict functional effects on visual acuity and contrast sensitivity from objective optical quality metrics. This, for instance, can be used to study monofocal lenses and the impact of asphericity on vision and IOLs tolerance to misalignment. Monofocal-plus IOLs consistently show only a slight improvement in the depth of focus when tested on the optical bench and in clinical settings. Although the pupil dependence found in this technology may limit the advantages of monofocal-plus over standard monofocal technology to extend the range of vision, it is the key to reduce photic phenomena. Refractive and diffractive extended depth of focus (EDOF) IOLs can effectively enhance intermediate vision, with the latter offering a slightly broader depth of focus but potentially increasing the risk of dysphotopsia. However, the limitation of EDOF IOLs is that they often fail to deliver spectacle independence for reading, which can be overcome by trifocal technology. Still, the available trifocal IOLs differ in their location of intermediate and near foci and the susceptibility to produce glare effects. Therefore, the knowledge from optical benchtop testing of IOLs can support optimizing the IOL selection by aligning the patient's visual needs with the IOL's properties, setting the right expectations, and assessing the risk profile for the occurrence of photic phenomena, potentially leading to improved decision-making.

4.
Ophthalmologie ; 2024 Jul 09.
Article in German | MEDLINE | ID: mdl-38980387

ABSTRACT

BACKGROUND: In recent years intraocular lenses (IOLs) for correcting presbyopia have been significantly improved and diversified. There are currently many different IOL models based on a wide variety of optical designs. OBJECTIVE: The wide variety of available IOL solutions to correct presbyopia can be challenging for surgeons and patients. In everyday practice, the question is which IOL is best for which patient. MATERIAL AND METHODS: This overview describes and categorizes the currently available implants. The respective optical properties are analyzed and clinical study results are discussed, in particular those evaluating visual performance and the occurrence of photic phenomena. RESULTS: Monofocal-plus IOLs provide improved intermediate visual acuity with optimal distant visual acuity and minimal photic phenomena. Extended depth of field (EDoF) IOLs extend the depth of field through different optical principles and provide good distant and intermediate visual acuity. Trifocal lenses enable the greatest independence from spectacles at the price of a higher probability of dysphotopsia. CONCLUSION: The selection of the most suitable IOL for correction of presbyopia requires a balance between the patient's visual needs and possible side effects. An adequate knowledge of the currently available implants allows a patient-oriented selection of IOLs.

6.
Eye (Lond) ; 2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39003429

ABSTRACT

PURPOSE: To develop and test a parameter for early keratoconus screening by quantifying the localized epithelial thickness differences in keratoconic eyes. METHODS: The cross-sectional study included 189 eyes of 116 subjects in total: 86 eyes of 54 keratoconus patients with bilateral ectasia and 40 eyes of 20 healthy subjects in the parameter-development dataset and 42 eyes of 21 keratoconus patients with asymmetric ectasia and 21 eyes of 21 healthy subjects in the parameter-validation dataset. Epithelial thickness maps were obtained using anterior segment optical coherence tomography and the inter-zonal epithelial thickness differences were calculated. The developed parameter was tested in keratoconus patients with asymmetric ectasia. RESULTS: Compared to healthy controls, the inferior-temporal and global inter-zonal epithelial thickness differences were higher not only in eyes with tomographically significant keratoconus (median [interquartile range] of 4.42 [3.13] µm vs. 0.78 [0.42] µm, p < 0.001, and 3.05 [1.51] µm vs. 1.07 [0.26] µm, p < 0.001, respectively), but also in tomographically normal keratoconus fellow eyes (1.36 [0.85] µm vs. 0.78 [0.42] µm, p = 0.005, and 1.31 [0.32] µm vs. 1.07 [0.26] µm, p = 0.01, respectively). The inferior-temporal inter-zonal epithelial thickness differences had an area under the receiver operating characteristic curve (95% confidence interval) of 0.991 (0.972-1) for detecting tomographically significant keratoconus and 0.749 (0.598-0.901) for differentiating between tomographically normal keratoconus fellow eyes and healthy controls. CONCLUSIONS: The inter-zonal epithelial thickness differences are increased in keratoconus fellow eyes which still have a normal Scheimpflug corneal tomography, and therefore may serve as a useful parameter to detect early ectatic changes.

7.
Am J Ophthalmol Case Rep ; 35: 102080, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38827999

ABSTRACT

Introduction: Calcification of hydrophilic intraocular lenses (IOL) is a rare complication following cataract surgery. Secondary calcification is described as due to host factors or changes in the IOL environment and uveitis, proliferative diabetic retinopathy and sequelae of ocular surgery are recognised potentiators. The impact of systemic connective tissue disease on IOL opacification is yet to described. Purpose: To describe the clinical presentation and management of a young patient, with a rare subtype of Ehlers-Danlos syndrome, who presented with secondary IOL calcification 14 years after primary IOL insertion. Observations: Floret-like lesions were observed on the IOL surface. Positive staining for calcification was observed with Alizarin red and von Kossa method on laboratory analysis. Conclusions and importance: Patients with systemic connective tissue disease, such as a subtype of Ehlers-Danlos, may present with secondary IOL calcification many years after primary lens insertion. This poses an additional consideration when implanting IOLs in these patients.Good visual acuity can be achieved with IOL exchange.

8.
Article in English | MEDLINE | ID: mdl-38884654

ABSTRACT

PURPOSE: To evaluate the biomechanical and tomographic outcomes of keratoconus patients up to four years after corneal crosslinking (CXL). METHODS: In this longitudinal retrospective-prospective single-center case series, the preoperative tomographic and biomechanical results from 200 keratoconus eyes of 161 patients undergoing CXL were compared to follow-up examinations at three-months, six-months, one-year, two-years, three-years, and four-years after CXL. Primary outcomes included the Corvis Biomechanical Factor (CBiF) and five biomechanical response parameters obtained from the Corvis ST. Tomographically, the Belin-Ambrósio deviation index (BAD-D) and the maximal keratometry (Kmax) measured by the Pentacam were analyzed. Additionally, Corvis E-staging, the thinnest corneal thickness (TCT), and the best-corrected visual acuity (BCVA) were obtained. Primary outcomes were compared using a paired t-test. RESULTS: The CBiF decreased significantly at the six-month (p < 0.001) and one-year (p < 0.001) follow-ups when compared to preoperative values. E-staging behaved accordingly to the CBiF. Within the two- to four-year follow-ups, the biomechanical outcomes showed no significant differences when compared to preoperative. Tomographically, the BAD-D increased significantly during the first year after CXL with a maximum at six-months (p < 0.001), while Kmax decreased significantly (p < 0.001) and continuously up to four years after CXL. The TCT was lower at all postoperative follow-up visits compared to preoperative, and the BCVA improved. CONCLUSION: In the first year after CXL, there was a temporary progression in both the biomechanical CBiF and E-staging, as well as in the tomographic analysis. CXL contributes to the stabilization of both the tomographic and biomechanical properties of the cornea up to four years postoperatively.

10.
Diagnostics (Basel) ; 14(11)2024 May 25.
Article in English | MEDLINE | ID: mdl-38893624

ABSTRACT

BACKGROUND: To clinically evaluate how dry eye symptoms in preoperatively diagnosed dry eye patients change with the use of sodium hyaluronate- and dexpanthenol-containing eye drops (HYLO CARE (HC), URSAPHARM Arzneimittel GmbH, Saarbruecken, Germany) after cataract surgery. The aim of the study was not to compare different eye drops but to implement standard treatment in patients with dry eye undergoing cataract surgery. The impact of treatment was evaluated using Symptom Assessment Tools for Dry Eye. METHODS: In this prospective, single-center, open-label clinical trial, 49 patients undergoing cataract surgery were included who showed signs and symptoms of dry eye disease assessed by the Symptom Assessment in Dry Eye (Visual Analogue Scale (VAS)) questionnaire, Ocular Surface Disease Index (OSDI), and fluorescein tear break-up Time (TBUT). Patients were instructed to apply HC three to four times a day for 5 weeks in the operated eye in addition to the standard postoperative topical anti-inflammatory regimen. The primary endpoint was the change in TBUT. Secondary endpoints were the assessment of the subjective symptoms (VAS), corrected distance visual acuity (CDVA), and slit-lamp examination including the corneal staining score, Schirmer test, and intraocular pressure. RESULTS: At 5 weeks after operation, the mean TBUT increased from 6.42 ± 1.57 s (s) to 7.81 ± 1.83 s in the per-protocol (PP) population (p > 0.001) and from 6.33 ± 1.64 s to 7.71 ± 2.05 s in the intention-to-treat (ITT) population (p < 0.001). There was a statistically significant decrease in all scores (p < 0.05) from the VAS questionnaire except for the tearing score (p = 0.062) at 5 weeks after operation. The mean total corneal staining score also decreased statistically significantly from 8.85 ± 2.49 before operation to 5.61 ± 3.37 at 5 weeks after operation on a 15-point scale. CONCLUSIONS: Controlled standardized dry eye treatment (with HC) improved tear film stability, ocular surface defects, and subjective symptoms of dry eye disease in patients 5 weeks after undergoing cataract surgery. Both the patient and physician assessments indicated high efficacy, tolerability, and a reliable safety profile, as indicated by the low number of at least possibly related adverse events (AE), suggesting its beneficial role in the postoperative management of the ocular surface (OS) in patients with dry eye symptoms prior to and after cataract surgery.

13.
Cornea ; 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38478752

ABSTRACT

PURPOSE: The purpose of this study was to determine whether the Scheimpflug tomographically normal fellow eyes of keratoconus patients are also classified as normal using an ectasia screening algorithm based on anterior segment optical coherence tomography (AS-OCT). METHODS: This monocentric cross-sectional study included 22 very asymmetric ectasia patients with tomographically significant keratoconus in 1 eye and normal Scheimpflug tomography in the fellow eye. Twenty-two eyes of 22 healthy subjects served as a control group. We performed corneal tomography using Pentacam AXL (Oculus, Wetzlar, Germany) and used Belin/Ambrósio Enhanced Ectasia total deviation index as well as Belin ABCD keratoconus classification to identify Scheimpflug tomographically normal eyes. We also performed AS-OCT using Anterion (Heidelberg Engineering, Heidelberg, Germany) and analyzed for the presence of ectasia using the Screening Corneal Objective Risk of Ectasia (SCORE) algorithm, with positive values indicating ectasia suspect tomography. RESULTS: The SCORE value was positive in 9.1% (n = 2) of the healthy eyes, in 45.5% (n = 10) of the Scheimpflug tomographically normal eyes of keratoconus patients and in all eyes (n = 22) with tomographically significant keratoconus. The Scheimpflug tomographically normal eyes of keratoconus patients had higher SCORE values compared with healthy controls (P < 0.001). The median (interquartile range) SCORE value was -1.7 (1.3) in healthy controls, -0.5 (2.2) in Scheimpflug tomographically normal eyes of keratoconus patients, and 11.1 (11.0) in tomographically significant keratoconus eyes. CONCLUSIONS: The Scheimpflug tomographically normal fellow eyes of keratoconus patients had higher AS-OCT-based SCORE values than healthy controls, with positive SCORE values found in 46% of the eyes, indicating early tomographic ectatic changes.

16.
J Refract Surg ; 40(2): e79-e88, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38346120

ABSTRACT

PURPOSE: To investigate the optical performance and tolerance to misalignment of blue-light filtering monofocal intraocular lenses (IOLs). METHODS: The optical properties of two monofocal IOLs featuring yellow chromophores, CT Lucia 621 PY (Carl Zeiss Meditec AG) and Clareon CNA0T0 (Alcon Laboratories, Inc), were assessed in monochromatic and polychromatic light while introducing spherical aberration (SA). Optical quality metrics derived from the modulation transfer function were assessed after optimal IOL centration at 3- and 4.5-mm pupils. In addition, each IOL's tolerance to misalignment was examined by inducing up to 1 mm of decentration and the effect of tilting it by 5 degrees at 3 mm. RESULTS: The IOLs' resolution and contrast, while tested using a 3-mm aperture and an SA-neutral corneal model, indicated the CT Lucia 621 PY had a slightly higher modulation transfer function (MTF) at 50 lp/mm than the CNA0T0 under monochromatic conditions (0.77 vs 0.69). On introducing SA with (0.49 vs 0.40) and without (0.75 vs. 0.70) chromatic aberration, the CT Lucia 621 PY maintained its minimally better performance. When assessed with a 4.5-mm aperture in monochromatic light, the CT Lucia 621 PY displayed improved MTF with aberration-free cornea (0.71 vs 0.40) but performed worse after introducing SA (0.44 vs 0.62). However, both lenses achieved comparable MTF values under spherical and chromatic aberrations (0.28 vs 0.27). The IOL misalignment test revealed a better tolerance to tilt and decentration of the CT Lucia 621 PY across all conditions. CONCLUSIONS: The CT Lucia 621 PY and CNA0T0 showed similar optical quality in different situations, with equal simulated distance visual acuity for both models. However, the CT Lucia 621 PY's aspheric design offers an advantage when dealing with often imperfect physiological conditions, displaying a more robust performance under tilt and decentration. [J Refract Surg. 2024;40(2):e79-e88.].


Subject(s)
Lenses, Intraocular , Humans , Vision, Ocular , Visual Acuity , Pupil , Blue Light , Prosthesis Design
17.
J Mech Behav Biomed Mater ; 152: 106368, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38340476

ABSTRACT

PURPOSE: To describe and analyse the particularities of the material and the optical quality of the first intraocular lens (IOL) (Eyedeal® lens) made of crosslinked polyisobutylene (xPIB). METHODS: We assessed the material quality using an accelerated ageing process (to provoke glistenings) and compared values with a control, AcrySof® lens. Using the sessile drop method, the contact angle of the new IOL was measured. Images of the lens surface were recorded by scanning electron microscopy (SEM). Optical quality was assessed by measuring the labeled power and modulation transfer function (MTF) using standard metrology equipment (OptiSpheric IOL PRO2). RESULTS: The Eyedeal® lens had an average glistening density result of 7.46 ± 3.78 MV/mm2 compared to the control AcrySof® whose glistenings number was 142.42 ± 72.47 MV/mm2. The contact angle was 97.2° whereas the angle of AcrySof material is between 73.3 ± 2.4° and 84.4 ± 0.1°. Using SEM, Eyedeal® lenses were examined and all appeared to be comparable to modern IOLs made of acrylic materials. The power and MTF values were normal and conformed to ISO standards. CONCLUSIONS: In the laboratory, the new Eyedeal® lens showed equivalence to current hydrophobic- or hydrophilic-acrylic lens models. It showed superiority in its glistening density result compared to the control lens.


Subject(s)
Lenses, Intraocular , Polymers , Polyenes , Laboratories , Microscopy, Electron, Scanning
18.
Adv Ther ; 41(4): 1481-1495, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38363465

ABSTRACT

INTRODUCTION: This study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups, respectively) in eyes with open-angle glaucoma. METHODS: This prospective, non-randomized, unmasked, longitudinal study included 125 consecutive iStent inject cases of a single surgeon at a large German academic hospital. Patients had considerable preoperative disease burden, with mean intraocular pressure (IOP) of 23.5 mmHg, 84.8% of eyes on ≥ 2 medications, and 38.4% of eyes with prior glaucoma surgery. IOP, medications, adverse events, and secondary surgeries were assessed through 7 years in the Overall cohort and in Combined (n = 81) and Standalone (n = 44) subgroups. RESULTS: Over 7-year follow-up, mean IOP decreased by 36.2-40.0% in Overall eyes, 34.1-38.9% in Combined eyes, and 39.5-43.5% in Standalone eyes (p < 0.001 at all timepoints for all groups). Meanwhile, mean medications decreased by 59.3-71.3% in Overall eyes, 57.9-69.0% in Combined eyes, and 62.1-76.2% in Standalone eyes (p < 0.001 at all timepoints in all groups). At last follow-up (mean 77.4 months; 92.8% of patients with last visit at 6 or 7 years), 83.7% of Overall eyes, 82.3% of Combined eyes, and 86.4% of Standalone eyes had achieved ≥ 20% IOP reduction vs preoperative. At last follow-up vs preoperative, 100% of eyes in all groups had the same or lower IOP and 100% had the same or lower medication regimen. Safety outcomes were favorable, with no filtration surgeries and only 4.84% of eyes experiencing clinically significant visual field loss over 7 years of follow-up. CONCLUSION: iStent inject implantation with or without phacoemulsification produced significant and durable 7-year reductions in IOP (~ 34-44% reduction) and medications (~ 58-76% reduction) while preventing filtering surgery in this cohort of patients with relatively high preoperative disease burden. Combined and Standalone cases had similarly favorable effectiveness and safety.


Subject(s)
Cataract Extraction , Glaucoma, Open-Angle , Humans , Glaucoma, Open-Angle/surgery , Longitudinal Studies , Prospective Studies , Intraocular Pressure , Stents
19.
Article in English, German | MEDLINE | ID: mdl-38242162

ABSTRACT

Although the safety of phakic intraocular lenses (pIOLs) has been continuously improved over 70-years of development, high endothelial cell losses can occur even with current pIOL models. Numerous studies have demonstrated that the distance of a pIOL to the corneal endothelium plays a crucial role in the extent of endothelial cell loss. For this reason alone, higher endothelial cell loss tends to be observed with anterior chamber lenses than with posterior chamber lenses. Adequate preoperative anterior chamber depth is essential, at least for iris-fixed pIOLs, in order to ensure a safe distance from the endothelium. However, the anterior chamber becomes shallower with age and therefore it may be useful to consider patient age in the safety criteria. Although endothelial cell loss is generally low with current pIOL models, regular monitoring of the endothelial cell density remains essential due to large interindividual differences in patients with pIOLs. If the endothelial cell loss is greater than expected and the follow-up visits confirm the trend, the pIOL should be explanted without delay. The endothelial reserve should be considered on an individual basis by taking into account patient age, physiological endothelial cell loss, and loss due to further surgery. With careful indication and long-term patient care, pIOLs remain a safe treatment option.

20.
J Refract Surg ; 40(1): e48-e56, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38190558

ABSTRACT

PURPOSE: To evaluate the biomechanical longitudinal variability and progression of tomographically normal fellow eyes of patients with keratoconus. METHODS: Of 513 patients with keratoconus, 30 patients with tomographically normal fellow eyes were included in this study. Tomographic and biomechanical parameters of the Pentacam and Corvis ST (Oculus Optikgeräte GmbH) were analyzed in multiple follow-up examinations, including the ABCD grading, Belin/Ambrósio Enhanced Ectasia total deviation index (BAD-D), Corvis Biomechanical Index (CBI), Corvis Biomechanical Factor (CBiF), and Tomographic and Biomechanical Index (TBI). A mixed regression model was applied. The results were compared to a healthy control group (n = 17) and a keratoconus group (n = 20). RESULTS: Within a maximum observation period of 3.3 years, no fellow eye (0%) showed a progression to tomographically evident keratoconus. No significant change in tomographic or biomechanical parameters was detected over the study period. The indices BAD-D, CBI, CbiF, and TBI exhibited a certain variability over time, whereas the tomographic ABC parameters and maximum keratometry barely changed. This was also shown in the control group and for all parameters in the keratoconus group, except the TBI. CONCLUSIONS: During the observation period none of the normal fellow eyes progressed to tomographically detectable keratoconus. However, biomechanical parameters CBI, CbiF, and TBI showed pathological values in 43.3% of eyes and certain variability. Subsequent studies with a longer observation period are warranted to confirm the biomechanical trends seen in this study and to rate the ability of single measurements to diagnose early keratoconus. [J Refract Surg. 2024;40(1):e48-e56.].