Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 364
Filter
1.
CJC Open ; 6(4): 649-655, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708054

ABSTRACT

Background: Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often, leadless pacemaker (LP) implantation is a de novo procedure, but in an increasing number of patients, an LP is used after previous implantation of a conventional pacing system (CPS). Methods: A retrospective analysis was conducted of the efficacy and safety of LP implantation in the context of a previously implanted CPS, from 2 large Swiss centres. Results: A total of 257 consecutive patients undergoing LP implantation were included. They were divided into 2 groups: group 1 consisted of 233 patients who did not have a previous CPS, and group 2 consisted of 24 patients with an in situ CPS. In group 2, a total of 20 patients (83%) required transvenous lead extraction due to infection, malfunction, or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, whereas in the remaining 11 cases, a time window occurred between the 2 procedures (median: 11.5 days; range: 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the 2 groups (mean: 12.5 ± 9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 instances of femoral bleeding, and 1 instance of intra-abdominal bleeding) in the entire cohort within a 30-day period. No complications occurred in the group with a previous device. No infections were registered, even when complete extraction of an infected CPS was performed prior to LP implantation. Conclusions: Implantation of an LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.


Contexte: La stimulation cardiaque sans fil a été établie comme une solution de substitution aux dispositifs transveineux chez certains patients. L'implantation d'un stimulateur cardiaque sans fil est souvent une intervention de novo, mais chez un nombre croissant de patients, ce type de stimulateur est utilisé après l'implantation d'un stimulateur classique. Méthodologie: Une analyse rétrospective de l'efficacité et de l'innocuité de la stimulation cardiaque sans fil dans le contexte de l'implantation d'un stimulateur classique a été réalisée dans deux grands centres suisses. Résultats: Un total de 257 patients consécutifs ayant subi l'implantation d'un stimulateur cardiaque sans fil ont été inclus. Les patients étaient répartis dans deux groupes; le groupe 1 était composé de 233 patients non porteurs d'un stimulateur classique, et le groupe 2, de 24 patients porteurs d'un stimulateur classique in situ. Dans le groupe 2, 20 patients au total (83 %) ont eu besoin d'une extraction de la sonde transveineuse en raison d'une infection, d'un défaut de fonctionnement, ou pour d'autres motifs. Chez 3 patients présentant une infection liée au stimulateur, l'extraction de la sonde et l'implantation d'un stimulateur cardiaque sans fil ont été réalisées simultanément, tandis que dans les 11 autres cas, il s'est écoulé un temps médian de 11,5 jours entre les deux interventions (min.-max. : 2-186 jours). Les paramètres relatifs au dispositif électrique au moment de l'implantation et pendant le suivi n'étaient pas différents entre les deux groupes (moyenne : 12,5 ± 9,3 mois). Huit complications périopératoires importantes (3,1 %) sont survenues (4 cas d'épanchement péricardique, 3 cas d'hémorragie fémorale et 1 cas d'hémorragie intra-abdominale) dans l'ensemble de la cohorte au cours d'une période de 30 jours. Aucune complication ne s'est produite dans le groupe de patients porteurs d'un stimulateur classique. On n'a enregistré aucun cas d'infection, même lorsque l'extraction complète du stimulateur classique infecté a été effectuée avant l'implantation du stimulateur cardiaque sans fil. Conclusions: L'implantation d'un stimulateur cardiaque sans fil chez les patients porteurs d'un stimulateur classique (avec ou sans extraction de ce stimulateur) était une intervention efficace et sûre dans cette population de patients.

2.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38749619

ABSTRACT

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Severity of Illness Index
3.
CJC Open ; 6(2Part A): 96-103, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38585679

ABSTRACT

Background: Impairment of the conduction system is a common complication of transcatheter aortic valve replacement (TAVR), which is typically performed in elderly patients. A leadless pacemaker (LP) may be a suitable option in this frail population, but the available scientific data concerning the efficacy and safety of leadless pacing after TAVR are sparse. The purpose of this analysis was to evaluate the efficacy and safety of LP implantation in patients with relevant bradycardias after TAVR, compared to other indications. Methods: Consecutive patients were retrospectively enrolled. Demographics, background heart diseases, interventional parameters, and follow-up data were collected. Results: A total of 257 consecutive patients who underwent LP implantation were included. In 26 patients, the device was implanted due to bradycardias after TAVR (TAVR group), whereas the remaining 231 patients were in the population without previous TAVR (non-TAVR group). The mean implantation duration (56 ± 22 minutes in the TAVR group vs 48 ± 20 minutes in the non-TAVR group; P = not significant [NS]) and the implantation success rate (100% in the TAVR group vs 98.7% in the non-TAVR group; P = NS) were similar in the 2 cohorts. No significant differences occurred in pacing parameters (sensing, impedance, and threshold, respectively) between the 2 groups, either at implantation or during follow-up. A total of 8 major periprocedural complications (3.1% of patients in total; 3.8% in the TAVR group vs 3.0% in the non-TAVR group; P = NS) occurred within 30 days, without significant difference between the 2 groups. Conclusions: LP implantation appears to be safe and effective in patients after TAVR, and therefore, this procedure is a suitable option for this often old and frail population.


Contexte: L'atteinte du système de conduction cardiaque est une complication courante du remplacement valvulaire aortique par cathéter (RVAC), une intervention habituellement pratiquée chez les patients âgés. Un stimulateur cardiaque sans sonde peut être une option convenable pour cette population fragile, mais les données scientifiques actuelles concernant l'efficacité et l'innocuité de la stimulation sans sonde après un RVAC sont fragmentaires. Cette analyse visait à évaluer l'efficacité et l'innocuité de l'implantation d'un stimulateur cardiaque sans sonde chez des patients atteints de bradycardies pertinentes après un RVAC, comparativement à d'autres indications. Méthodologie: Des patients consécutifs ont été recrutés de manière rétrospective. Les données démographiques, les maladies cardiaques sous-jacentes, les paramètres interventionnels et les données de suivi ont été colligés. Résultats: Un total de 257 patients consécutifs qui se sont fait implanter un stimulateur cardiaque sans sonde ont été inclus. Chez 26 patients, le dispositif a été implanté en raison d'une bradycardie après un RVAC (groupe RVAC), alors que les 231 autres patients formaient la population sans RVAC antérieur (groupe sans RVAC). La durée moyenne de l'intervention d'implantation (56 ± 22 minutes dans le groupe RVAC vs 48 ± 20 minutes dans le groupe sans RVAC; p = non significatif [NS]) et le taux de réussite de l'implantation (100 % dans le groupe RVAC vs 98,7 % dans le groupe sans RVAC; p = NS) étaient similaires dans les deux cohortes. Aucune différence significative n'a été observée dans les paramètres de stimulation (sensibilité, impédance et seuil, respectivement) entre les 2 groupes, que ce soit au moment de l'implantation ou pendant le suivi. Un total de 8 complications périopératoires majeures (3,1 % de l'ensemble des patients; 3,8 % dans le groupe RVAC vs 3,0 % dans le groupe sans RVAC; p = NS) sont survenues dans les 30 jours, sans différence notable entre les 2 groupes. Conclusions: L'implantation d'un stimulateur cardiaque sans sonde semble sûre et efficace après un RVAC; par conséquent, cette intervention représente une option convenable pour cette population souvent âgée et fragile.

4.
Heart Rhythm ; 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38604592

ABSTRACT

BACKGROUND: The utility of atrioventricular (AV) optimization (AVO) algorithms remains in question. A substudy of the SMART-AV trial found that patients with prolonged interventricular delays ≥70 ms were more likely to benefit from cardiac resynchronization therapy (CRT) with AVO. The SMART-CRT trial evaluated AVO on the basis of these results, but the study was underpowered. OBJECTIVE: To increase statistical power, data from SMART-AV patients meeting the inclusion criterion of interventricular delay ≥70 ms were pooled with data from SMART-CRT to reassess AVO. METHODS: SMART-CRT and SMART-AV were prospective, randomized, multicenter clinical trials. Patients in both studies were randomized to be programmed with an AVO algorithm (SmartDelay) or fixed AV delay (120 ms). Paired echocardiograms obtained at baseline and 6 months were compared, with CRT response defined as ≥15% reduction in left ventricular end-systolic volume. RESULTS: A total of 451 complete patient data sets were pooled and analyzed. The baseline demographics between studies did not differ statistically in terms of age, sex, left ventricular ejection fraction, or left ventricular end-systolic volume. The AVO group had a greater proportion of CRT responders (SmartDelay, 73.9%; fixed, 63.1%; P = .014) and greater changes in measures of reverse remodeling. SmartDelay patients with a recommended sensed AV delay outside the nominal range (100-120 ms) had 2.3 greater odds of CRT response than fixed AV delay patients. CONCLUSION: Greater CRT response and measures of reverse remodeling were observed in patients with SmartDelay enabled vs a fixed AV delay. This study supports the use of SmartDelay in patients with a CRT indication and interventricular delay ≥70 ms. GOV REGISTRATION: NCT00677014 and NCT03089281.

5.
Eur Heart J ; 45(14): 1269-1277, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38546408

ABSTRACT

BACKGROUND AND AIMS: Bloodstream infection (BSI) of any cause may lead to device infection in cardiac implantable electronic device (CIED) patients. Aiming for a better understanding of the diagnostic approach, treatment, and outcome, patients with an implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy and defibrillator (CRT-D) hospitalized with BSI were investigated. METHODS: This is a single-centre, retrospective, cohort analysis including consecutive ICD/CRT-D patients implanted between 2012 and 2021. These patients were screened against a list of all hospitalized patients having positive blood cultures consistent with diagnosed infection in any department of a local public hospital. RESULTS: The total cohort consisted of 515 patients. Over a median follow-up of 59 months (interquartile range 31-87 months), there were 47 BSI episodes in 36 patients. The majority of patients with BSI (92%) was admitted to non-cardiology units, and in 25 episodes (53%), no cardiac imaging was performed. Nearly all patients (85%) were treated with short-term antibiotics, whereas chronic antibiotic suppression therapy (n = 4) and system extraction (n = 3) were less frequent. Patients with BSI had a nearly seven-fold higher rate (hazard ratio 6.7, 95% confidence interval 3.9-11.2; P < .001) of all-cause mortality. CONCLUSIONS: Diagnostic workup of defibrillator patients with BSI admitted to a non-cardiology unit is often insufficient to characterize lead-related endocarditis. The high mortality rate in these patients with BSI may relate to underdiagnosis and consequently late/absence of system removal. Efforts to increase an interdisciplinary approach and greater use of cardiac imaging are necessary for timely diagnosis and adequate treatment.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Sepsis , Humans , Retrospective Studies , Defibrillators, Implantable/adverse effects , Cardiac Resynchronization Therapy/methods , Anti-Bacterial Agents/therapeutic use , Sepsis/etiology , Cardiac Resynchronization Therapy Devices , Treatment Outcome
6.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38445836

ABSTRACT

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Subject(s)
Brugada Syndrome , Defibrillators, Implantable , Pacemaker, Artificial , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography/methods , Electrocardiography, Ambulatory/methods , Adult
7.
Article in English | MEDLINE | ID: mdl-38520434

ABSTRACT

BACKGROUND: Past clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICDs) for reducing sudden cardiac death in at-risk patients. However, heart failure management and ICD technology have changed since these trials were first published. An updated assessment of ICD mortality benefit is needed. OBJECTIVES: The purpose of this study was to compare mortality rates between patients with a primary prevention (PP) indication for an ICD who did or did not receive an ICD using a contemporary, real-world data set. METHODS: Data was obtained from a large electronic health record data set covering patients in the United States from 2012 through 2020 who had a PP indication for an ICD and survived at least 1-year postindication. RESULTS: A total of 25,296 patients were identified as having a PP indication for ICD implantation, of which 2,118 (8.4%) were treated with an ICD within a year. Treated patients were younger than nontreated patients (63.4 years vs 66.1 years) with a smaller proportion of women (25.0% vs 36.7%). After 4-to-1 propensity matching, treated patients had similar clinical characteristics to nontreated patients. A Cox proportional hazard model estimated a 24.3% lower risk of all-cause mortality in patients when treated vs not treated with an ICD (HR: 0.757; CI: 0.678-0.835; P <0.001). There was no detectable difference in ICD benefit between patients with ischemic and nonischemic heart disease (P = 0.50). CONCLUSIONS: ICD treatment of patients with a PP indication is associated with improved mortality even in the context of evolving adjunctive HF treatment, consistent with earlier landmark trials.

8.
Resuscitation ; 197: 110113, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38218400

ABSTRACT

BACKGROUND AND AIMS: The Utstein Based-ROSC (UB-ROSC) score has been developed to predict ROSC in OHCA victims. Aim of the study was to validate the UB-ROSC score using two Utstein-based OHCA registries: the SWiss REgistry of Cardiac Arrest (SWISSRECA) and the Lombardia Cardiac Arrest Registry (Lombardia CARe), northern Italy. METHODS: Consecutive patients with OHCA of any etiology occurring between January 1st, 2019 and December 31st 2021 were included in this retrospective validation study. UB-ROSC score was computed for each patient and categorized in one of three subgroups: low, medium or high likelihood of ROSC according to the UB-ROSC cut-offs (≤-19; -18 to 12; ≥13). To assess the performance of the UB-ROSC score in this new cohort, we assessed both discrimination and calibration. The score was plotted against the survival to hospital admission. RESULTS: A total of 12.577 patients were included in the study. A sustained ROSC was obtained in 2.719 patients (22%). The UB-ROSC model resulted well calibrated and showed a good discrimination (AUC 0.71, 95% CI 0.70-0.72). In the low likelihood subgroup of UB-ROSC, only 10% of patients achieved ROSC, whereas the proportion raised to 36% for a score between -18 and 12 (OR 5.0, 95% CI 2.9-8.6, p < 0.001) and to 85% for a score ≥13 (OR 49.4, 95% CI 14.3-170.6, p < 0.001). CONCLUSIONS: UB-ROSC score represents a reliable tool to predict ROSC probability in OHCA patients. Its application may help the medical decision-making process, providing a realistic stratification of the probability for ROSC.


Subject(s)
Cardiopulmonary Resuscitation , Emergency Medical Services , Out-of-Hospital Cardiac Arrest , Humans , Out-of-Hospital Cardiac Arrest/therapy , Retrospective Studies , Return of Spontaneous Circulation , Cardiopulmonary Resuscitation/methods , Hospitalization
9.
Resuscitation ; 194: 110043, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37952575

ABSTRACT

AIM: Prior studies have reported increased out-of-hospital cardiac arrests (OHCA) incidence and lower survival during the COVID-19 pandemic. We evaluated how the COVID-19 pandemic affected OHCA incidence, bystander CPR rate and patients' outcomes, accounting for regional COVID-19 incidence and OHCA characteristics. METHODS: Individual patient data meta-analysis of studies which provided a comparison of OHCA incidence during the first pandemic wave (COVID-period) with a reference period of the previous year(s) (pre-COVID period). We computed COVID-19 incidence per 100,000 inhabitants in each of 97 regions per each week and divided it into its quartiles. RESULTS: We considered a total of 49,882 patients in 10 studies. OHCA incidence increased significantly compared to previous years in regions where weekly COVID-19 incidence was in the fourth quartile (>136/100,000/week), and patients in these regions had a lower odds of bystander CPR (OR 0.49, 95%CI 0.29-0.81, p = 0.005). Overall, the COVID-period was associated with an increase in medical etiology (89.2% vs 87.5%, p < 0.001) and OHCAs at home (74.7% vs 67.4%, p < 0.001), and a decrease in shockable initial rhythm (16.5% vs 20.3%, p < 0.001). The COVID-period was independently associated with pre-hospital death (OR 1.73, 95%CI 1.55-1.93, p < 0.001) and negatively associated with survival to hospital admission (OR 0.68, 95%CI 0.64-0.72, p < 0.001) and survival to discharge (OR 0.50, 95%CI 0.46-0.54, p < 0.001). CONCLUSIONS: During the first COVID-19 pandemic wave, there was higher OHCA incidence and lower bystander CPR rate in regions with a high-burden of COVID-19. COVID-19 was also associated with a change in patient characteristics and lower survival independently of COVID-19 incidence in the region where OHCA occurred.


Subject(s)
COVID-19 , Cardiopulmonary Resuscitation , Emergency Medical Services , Out-of-Hospital Cardiac Arrest , Humans , COVID-19/epidemiology , COVID-19/complications , Cardiopulmonary Resuscitation/adverse effects , Pandemics , Out-of-Hospital Cardiac Arrest/epidemiology , Out-of-Hospital Cardiac Arrest/therapy , Out-of-Hospital Cardiac Arrest/etiology
10.
Comput Biol Med ; 167: 107655, 2023 12.
Article in English | MEDLINE | ID: mdl-37976830

ABSTRACT

Large high-quality datasets are essential for building powerful artificial intelligence (AI) algorithms capable of supporting advancement in cardiac clinical research. However, researchers working with electrocardiogram (ECG) signals struggle to get access and/or to build one. The aim of the present work is to shed light on a potential solution to address the lack of large and easily accessible ECG datasets. Firstly, the main causes of such a lack are identified and examined. Afterward, the potentials and limitations of cardiac data generation via deep generative models (DGMs) are deeply analyzed. These very promising algorithms have been found capable not only of generating large quantities of ECG signals but also of supporting data anonymization processes, to simplify data sharing while respecting patients' privacy. Their application could help research progress and cooperation in the name of open science. However several aspects, such as a standardized synthetic data quality evaluation and algorithm stability, need to be further explored.


Subject(s)
Artificial Intelligence , Electrocardiography , Humans , Heart , Algorithms , Data Accuracy
11.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37944131

ABSTRACT

AIMS: Brugada syndrome (BrS) is an inherited disease associated with an increased risk of ventricular arrhythmias. Recent studies have reported the presence of an altered atrial phenotype characterized by abnormal P-wave parameters. The aim of this study was to identify BrS based exclusively on P-wave features through an artificial intelligence (AI)-based model. METHODS AND RESULTS: Continuous 5 min 12-lead ECG recordings were obtained in sinus rhythm from (i) patients with spontaneous or ajmaline-induced BrS and no history of AF and (ii) subjects with suspected BrS and negative ajmaline challenge. The recorded ECG signals were processed and divided into epochs of 15 s each. Within these epochs, P-waves were first identified and then averaged. From the averaged P-waves, a total of 67 different features considered relevant to the classification task were extracted. These features were then used to train nine different AI-based supervised classifiers. A total of 2228 averaged P-wave observations, resulting from the analysis of 33 420 P-waves, were obtained from 123 patients (79 BrS+ and 44 BrS-). Averaged P-waves were divided using a patient-wise split, allocating 80% for training and 20% for testing, ensuring data integrity and reducing biases in AI-based model training. The BrS+ patients presented with longer P-wave duration (136 ms vs. 124 ms, P < 0.001) and higher terminal force in lead V1 (2.5 au vs. 1.7 au, P < 0.01) compared with BrS- subjects. Among classifiers, AdaBoost model had the highest values of performance for all the considered metrics, reaching an accuracy of over 81% (sensitivity 86%, specificity 73%). CONCLUSION: An AI machine-learning model is able to identify patients with BrS based only on P-wave characteristics. These findings confirm the presence of an atrial hallmark and open new horizons for AI-guided BrS diagnosis.


Subject(s)
Atrial Fibrillation , Brugada Syndrome , Humans , Atrial Fibrillation/chemically induced , Artificial Intelligence , Ajmaline/adverse effects , Electrocardiography/methods
12.
Resusc Plus ; 16: 100469, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37779882

ABSTRACT

Background/Aims: Limited bystander assistance and delayed emergency medical service arrival reduce the chances of survival in cardiac arrest victims. Early basic life support through trained first responders (FR) and automatic external defibrillation both improve the outcome. Well-organized FR networks have shown promise, but guidance on effective implementation is lacking. This study evaluates two FR networks, in Belgium and in Switzerland, to identify main advancements in the development of such systems. Method: Direct comparison is made of the barriers and facilitators in the development of both FR systems from 2006 up until December 2022, and summarized within a roadmap. Results: The Roadmap comprises four integral steps: exploration, installation, initiation, and implementation. Exploration involves understanding the national legislation, engaging with advisory bodies, and establishing local steering committees. The installation phase focuses on FR recruitment, engaging specific professional groups such as firemen, registering public Automated External Defibrillators (AEDs), and requesting feedback. The initiation step includes implementing improvement cycles and fidelity measures. Finally, implementation expands the network, leading to increased survival rates and the integration of these practices into legislation. A significant focus is placed on FR's psychological wellbeing. Moreover, the roadmap highlights the use of efficient geo-mapping to simplify optimal AED placement and automatically assign FRs to tasks. Conclusion: The importance of FR networks for early resuscitation is increasingly recognized and various systems are being developed. Key developmental strategies of the EVapp and Ticino Cuore app system may serve as a roadmap for other systems and implementations within Europe and beyond.

17.
Europace ; 25(8)2023 08 25.
Article in English | MEDLINE | ID: mdl-37622580

ABSTRACT

Cardiac resynchronization therapy (CRT) was proposed in the 1990s as a new therapy for patients with heart failure and wide QRS with depressed left ventricular ejection fraction despite optimal medical treatment. This review is aimed first to describe the rationale and the physiologic effects of CRT. The journey of the landmark randomized trials leading to the adoption of CRT in the guidelines since 2005 is also reported showing the high level of evidence for CRT. Different alternative pacing modalities of CRT to conventional left ventricular pacing through the coronary sinus have been proposed to increase the response rate to CRT such as multisite pacing and endocardial pacing. A new emerging alternative technique to conventional biventricular pacing, conduction system pacing (CSP), is a promising therapy. The different modalities of CSP are described (Hirs pacing and left bundle branch area pacing). This new technique has to be evaluated in clinical randomized trials before implementation in the guidelines with a high level of evidence.


Subject(s)
Cardiac Resynchronization Therapy , Humans , Stroke Volume , Ventricular Function, Left , Cardiac Conduction System Disease , Heart Conduction System
18.
J Clin Med ; 12(16)2023 Aug 08.
Article in English | MEDLINE | ID: mdl-37629216

ABSTRACT

BACKGROUND: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. METHODS: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. RESULTS: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14-1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). CONCLUSIONS: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure.

19.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37490349

ABSTRACT

AIMS: After an ischaemic stroke, atrial fibrillation (AF) detection allows for improved secondary prevention strategies. This study aimed to compare AF detection and oral anticoagulant (OAC) initiation in patients with an insertable cardiac monitor (ICM) vs. external cardiac monitor (ECM) after ischaemic stroke. METHODS AND RESULTS: Medicare Fee-for-Service (FFS) insurance claims and Abbott Labs device registration data were used to identify patients hospitalized with an ischaemic stroke in 2017-2019 who received an ICM or ECM within 3 months. Patients with continuous Medicare FFS insurance and prescription drug enrolment in the prior year were included. Patients with prior AF, atrial flutter, cardiac devices, or OAC were excluded. Insertable cardiac monitor and ECM patients were propensity score matched 1:4 on demographics, comorbidities, and stroke hospitalization characteristics. The outcomes of interest were AF detection and OAC initiation evaluated with Kaplan-Meier and Cox proportional hazard regression analyses. A total of 5702 Medicare beneficiaries (ICM, n = 444; ECM, n = 5258) met inclusion criteria. The matched cohort consisted of 2210 Medicare beneficiaries (ICM, n = 442; ECM, n = 1768) with 53% female, mean age 75 years, and mean CHA2DS2-VASc score 4.6 (1.6). Insertable cardiac monitor use was associated with a higher probability of AF detection [(hazard ratio (HR) 2.88, 95% confidence interval (CI) (2.31, 3.59)] and OAC initiation [HR 2.91, CI (2.28, 3.72)] compared to patients monitored only with ECM. CONCLUSION: Patients with an ischaemic stroke monitored with an ICM were almost three times more likely to be diagnosed with AF and to be prescribed OAC compared to patients who received ECM only.


Subject(s)
Atrial Fibrillation , Brain Ischemia , Ischemic Stroke , Stroke , Humans , Female , Aged , United States/epidemiology , Male , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology , Brain Ischemia/diagnosis , Brain Ischemia/epidemiology , Brain Ischemia/prevention & control , Medicare , Anticoagulants/adverse effects , Prescriptions
20.
J Am Coll Cardiol ; 82(3): 200-210, 2023 07 18.
Article in English | MEDLINE | ID: mdl-37438006

ABSTRACT

BACKGROUND: Systems for dispatch of volunteer responders to collect automated external defibrillators and/or to provide cardiopulmonary resuscitation (CPR) in cases of nearby out-of-hospital cardiac arrest (OHCA) are widely implemented. OBJECTIVES: This study aimed to investigate whether the activation of a volunteer responder system to OHCAs was associated with higher rates of bystander CPR, bystander defibrillation, and 30-day survival vs no system activation. METHODS: This was a retrospective observational analysis within the ESCAPE-NET (European Sudden Cardiac Arrest network: Towards Prevention, Education, New Effective Treatment) collaborative research network. Included were cases of OHCA between 2015 and 2019 from 5 European sites with volunteer responder systems. At all sites, systems were activated by dispatchers at the emergency medical communication center in response to suspected OHCA. Exposed cases (system activation) were compared with nonexposed cases (no system activation). Risk ratios (RRs) were calculated for the outcomes of bystander CPR, bystander defibrillation, and 30-day survival after inverse probability treatment weighting. Missing data were handled using multiple imputation. RESULTS: In total, 9,553 cases were included. In 4,696 cases, the volunteer responder system was activated, and in 4,857 it was not. The pooled RRs were 1.30 (95% CI: 1.15-1.47) for bystander CPR, 1.89 (95% CI: 1.36-2.63) for bystander defibrillation, and 1.22 (95% CI: 1.07-1.39) for 30-day survival. CONCLUSIONS: Activation of a volunteer response system in cases of OHCA was associated with a higher chance of bystander CPR, bystander defibrillation, and 30-day survival vs no system activation. A randomized controlled trial is necessary to determine fully the causal effect of volunteer responder systems.


Subject(s)
Out-of-Hospital Cardiac Arrest , Humans , Out-of-Hospital Cardiac Arrest/therapy , Communication , Death, Sudden, Cardiac , Hospitals , Volunteers
SELECTION OF CITATIONS
SEARCH DETAIL
...