Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 81
Filter
1.
J Mech Behav Biomed Mater ; 124: 104814, 2021 12.
Article in English | MEDLINE | ID: mdl-34534845

ABSTRACT

The present paper aims at developing an integrated experimental/computational approach towards the design of shape memory devices fabricated by hot-processing with potential for use as gastroretentive drug delivery systems (DDSs) and for personalized therapy if 4D printing is involved. The approach was tested on a plasticized poly(vinyl alcohol) (PVA) of pharmaceutical grade, with a glass transition temperature close to that of the human body (i.e., 37 °C). A comprehensive experimental analysis was conducted in order to fully characterize the PVA thermo-mechanical response as well as to provide the necessary data to calibrate and validate the numerical predictions, based on a thermo-viscoelastic constitutive model, implemented within a finite element framework. Particularly, a thorough thermal, mechanical, and shape memory characterization under different testing conditions and on different sample geometries was first performed. Then, a prototype consisting of an S-shaped device was fabricated, deformed in a temporary compact configuration and tested. Simulation results were compared with the results obtained from shape memory experiments carried out on the prototype. The proposed approach provided useful results and recommendations for the design of PVA-based shape memory DDSs.


Subject(s)
Pharmaceutical Preparations , Smart Materials , Drug Delivery Systems , Humans , Polyvinyl Alcohol , Printing, Three-Dimensional
2.
Int J Artif Organs ; 42(10): 558-565, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31170878

ABSTRACT

Multi-Detector Computed Tomography is nowadays the gold standard for the pre-operative imaging for several surgical interventions, thanks to its excellent morphological definition. As for vascular structures, only the blood flowing inside vessels can be highlighted, while vessels' wall remains mostly invisible. Image segmentation and three-dimensional-printing technology can be used to create physical replica of patient-specific anatomy, to be used for the training of novice surgeons in robotic surgery. To this aim, it is fundamental that the model correctly resembles the morphological properties of the structure of interest, especially concerning vessels on which crucial operations are performed during the intervention. To reach the goal, vessels' actual size must be restored, including information on their wall. Starting from the correlation between vessels' lumen diameter and their wall thickness, we developed a semi-automatic approach to compute the local vessels' wall, bringing the vascular structures as close as possible to their actual size. The optimized virtual models are suitable for manufacturing by means of three-dimensional-printing technology to build patient-specific phantoms for the surgical simulation of robotic abdominal interventions. The proposed approach can effectively lead to the generation of vascular models of optimized thickness wall. The feasibility of the approach is also tested on a selection of clinical cases in abdominal surgery, on which the robotic surgery is performed on the three-dimensional-printed replica before the actual intervention.


Subject(s)
Blood Vessels , Models, Anatomic , Printing, Three-Dimensional , Robotic Surgical Procedures/education , Blood Vessels/diagnostic imaging , Humans , Multidetector Computed Tomography
3.
Comput Biol Med ; 103: 140-147, 2018 12 01.
Article in English | MEDLINE | ID: mdl-30368170

ABSTRACT

Thoracic endovascular aortic repair of the ascending aorta is becoming an option for patients considered unfit for open surgery. Such an endovascular procedure requires careful pre-operative planning and the customization of prosthesis design. The patient-specific tailoring of the procedure may call for dedicated tools to investigate virtual treatment scenarios. Given such considerations, the present study shows a computational framework for choosing and deploying stent-grafts via Finite Element Analysis, by supporting the device sizing and selection in a real case dealing with the endovascular treatment of a pseudoaneurysm. In particular, three devices with various lengths and materials were examined. Two off-the-shelf devices were computationally tested: one composed of Stainless Steel rings with a nominal length of 60 mm and another one with Nitinol rings and a distal free flow extension, with a nominal length of 70 mm. In third place, a custom-made stent-graft, also with Nitinol rings and containing both proximal and distal bare extensions with a nominal length of 75 mm, was deployed. The latter solution based on patient morphology and virtually benchmarked in this simulation framework, enhanced the apposition to the wall by reducing the distance between the skirt and the vessel from more than 6 mm to less than 2 mm in the distal sealing zone. Our experience shows that in-silico simulations can help choosing the right endograft for the ascending aorta as well as the right deployment sequence. This process may also encourage vendors to develop new devices for cases where open repair is unfeasible.


Subject(s)
Aorta/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Patient-Specific Modeling , Aged , Aneurysm, False/diagnostic imaging , Aneurysm, False/surgery , Aorta/diagnostic imaging , Aortic Diseases/diagnostic imaging , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Finite Element Analysis , Humans , Male , Tomography, X-Ray Computed
4.
Acta Otorhinolaryngol Ital ; 38(4): 286-303, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30197421

ABSTRACT

3D printing systems have revolutionised prototyping in the industrial field by lowering production time from days to hours and costs from thousands to just a few dollars. Today, 3D printers are no more confined to prototyping, but are increasingly employed in medical disciplines with fascinating results, even in many aspects of otorhinolaryngology. All publications on ENT surgery, sourced through updated electronic databases (PubMed, MEDLINE, EMBASE) and published up to March 2017, were examined according to PRISMA guidelines. Overall, 121 studies fulfilled specific inclusion criteria and were included in our systematic review. Studies were classified according to the specific field of application (otologic, rhinologic, head and neck) and area of interest (surgical and preclinical education, customised surgical planning, tissue engineering and implantable prosthesis). Technological aspects, clinical implications and limits of 3D printing processes are discussed focusing on current benefits and future perspectives.


Subject(s)
Otorhinolaryngologic Surgical Procedures , Printing, Three-Dimensional , Humans
5.
Acta Otorhinolaryngol Ital ; 38(3): 251-256, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29984791

ABSTRACT

SUMMARY: The aim of the present study was to assess the feasibility and utility of 3D printing technology in surgical planning of a transcutaneous bone-conduction hearing device (Bonebridge®) (BB), focusing on the identification of the proper location and placement of the transducer. 3D printed (3DP) models of three human cadaveric temporal bones, previously submitted to CT scan, were created with the representation of a topographic bone thickness map and the sinus pathway on the outer surface. The 3DP model was used to detect the most suitable location for the BB. A 3DP transparent mask that faithfully reproduced the surface of both the temporal bone and the 3DP model was also developed to correctly transfer the designated BB area. The accuracy of the procedure was verified by CT scan: a radiological marker was used to evaluate the degree of correspondence of the transducer site between the 3DP model and the human temporal bone. The BB positioning was successfully performed on all human temporal bones, with no difficulties in finding the proper location of the transducer. A mean error of 0.13 mm was found when the transducer site of the 3DP model was compared to that of the human temporal bone. The employment of 3D printing technology in surgical planning of BB positioning showed feasible results. Further studies will be required to evaluate its clinical applicability.


Subject(s)
Hearing Aids , Patient Care Planning , Printing, Three-Dimensional , Prostheses and Implants , Tomography, X-Ray Computed , Bone Conduction , Cadaver , Equipment Design , Feasibility Studies , Humans , Preoperative Period , Surgery, Computer-Assisted
6.
Med Eng Phys ; 47: 13-24, 2017 09.
Article in English | MEDLINE | ID: mdl-28705512

ABSTRACT

Nitinol stents continuously experience loadings due to pulsatile pressure, thus a given stent design should possess an adequate fatigue strength and, at the same time, it should guarantee a sufficient vessel scaffolding. The present study proposes an optimization framework aiming at increasing the fatigue life reducing the maximum strut strain along the structure through a local modification of the strut profile.The adopted computational framework relies on nonlinear structural finite element analysis combined with a Multi Objective Genetic Algorithm, based on Kriging response surfaces. In particular, such an approach is used to investigate the design optimization of planar stent cell.The results of the strut profile optimization confirm the key role of a tapered strut design to enhance the stent fatigue strength, suggesting that it is possible to achieve a marked improvement of both the fatigue safety factor and the scaffolding capability simultaneously. The present study underlines the value of advanced engineering tools to optimize the design of medical devices.


Subject(s)
Alloys/chemistry , Blood Vessel Prosthesis , Computer-Aided Design , Equipment Design/methods , Models, Theoretical , Stents , Algorithms , Compressive Strength , Computer Simulation , Elastic Modulus , Equipment Failure Analysis/methods , Finite Element Analysis , Pressure , Stress, Mechanical , Tensile Strength
7.
Eur J Vasc Endovasc Surg ; 53(2): 199-205, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28027889

ABSTRACT

OBJECTIVES: Reference values of aortic deformation during the cardiac cycle can be valuable for the pre-operative planning of thoracic endovascular aortic repair (TEVAR) and for facilitating computational fluid dynamics. This study aimed to quantify normal aortic extensibility (longitudinal extension) and distensibility (radial expansion), as well as pulsatile strain, in a group of 10 (>60 years) individuals with abdominal or thoracic aortic aneurysms. METHODS: ECG gated CT images of the thoracic aorta were reconstructed into virtual 3D models of aortic geometry. The centre lumen line length of the thoracic aorta and three longitudinal segments, and the aortic diameter and luminal areas of four radial intersections were extracted with a dedicated software script to calculate extensibility, longitudinal strain, distensibility, and circumferential area strain. RESULTS: Mean extensibility and longitudinal strain of the entire thoracic aorta were 3.5 [1.3-6.8] × 10-3 N-1, and 2.7 [1.0-4.5]%, respectively. Extensibility and longitudinal strain were most pronounced in the ascending aorta (20.6 [5.7-36.2] × 10-3 N-1 and 15.9 [6.6-31.9]%) and smallest in the descending aorta (4.4 [1.6-12.3] × 10-3 N-1 and 2.2 [0.7-4.7]%). Mean distensibility and circumferential area strain were most pronounced at the sinotubular junction (1.7 [0.5-2.9] × 10-3 mmHg-1 and 11.3 [3.3-18.5]%, respectively). Distensibility varied between 0.9 [0.3-2.5] × 10-3 mmHg-1 and 1.2 [0.3-3.3] × 10-3 mmHg-1 at the intersections in the aortic arch and descending aorta. CONCLUSIONS: Pulsatile deformations in both longitudinal and circumferential directions are considerable throughout the thoracic aorta. These findings may have implications for pre-operative TEVAR planning and highlight the need for devices that can mimic the significant aortic longitudinal and circumferential strains.


Subject(s)
Aorta, Thoracic/physiopathology , Aortic Aneurysm, Abdominal/physiopathology , Aortic Aneurysm, Thoracic/physiopathology , Models, Cardiovascular , Pulsatile Flow , Aged , Aged, 80 and over , Aorta, Thoracic/diagnostic imaging , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortography/methods , Biomechanical Phenomena , Cardiac-Gated Imaging Techniques , Computed Tomography Angiography , Computer Simulation , Electrocardiography , Female , Humans , Male , Multidetector Computed Tomography , Regional Blood Flow , Retrospective Studies , Stress, Mechanical
8.
Updates Surg ; 68(3): 273-278, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27605209

ABSTRACT

We propose an innovative tool for Pancreatic Ductal AdenoCarcinoma 3D reconstruction from Multi-Detector-Computed Tomography. The tumor mass is discriminated from health tissue, and the resulting segmentation labels are rendered preserving information on different hypodensity levels. The final 3D virtual model includes also pancreas and main peri-pancreatic vessels, and it is suitable for 3D printing. We performed a preliminary evaluation of the tool effectiveness presenting ten cases of Pancreatic Ductal AdenoCarcinoma processed with the tool to an expert radiologist who can correct the result of the discrimination. In seven of ten cases, the 3D reconstruction is accepted without any modification, while in three cases, only 1.88, 5.13, and 5.70 %, respectively, of the segmentation labels are modified, preliminary proving the high effectiveness of the tool.


Subject(s)
Imaging, Three-Dimensional , Multidetector Computed Tomography/methods , Neoplasm Staging/methods , Pancreas/diagnostic imaging , Pancreatic Neoplasms/diagnosis , Printing, Three-Dimensional , Humans , Reproducibility of Results
9.
J Biomech ; 49(12): 2513-9, 2016 08 16.
Article in English | MEDLINE | ID: mdl-26748728

ABSTRACT

Prosthesis positioning in transcatheter aortic valve implantation procedures represents a crucial aspect for procedure success as demonstrated by many recent studies on this topic. Possible complications, device performance, and, consequently, also long-term durability are highly affected by the adopted prosthesis placement strategy. In the present work, we develop a computational finite element model able to predict device-specific and patient-specific replacement procedure outcomes, which may help medical operators to plan and choose the optimal implantation strategy. We focus in particular on the effects of prosthesis implantation depth and release angle. We start from a real clinical case undergoing Corevalve self-expanding device implantation. Our study confirms the crucial role of positioning in determining valve anchoring, replacement failure due to intra or para-valvular regurgitation, and post-operative device deformation.


Subject(s)
Patient-Specific Modeling , Transcatheter Aortic Valve Replacement/methods , Aged , Aortic Valve Stenosis/surgery , Finite Element Analysis , Humans , Male , Postoperative Period , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome
10.
Ann Biomed Eng ; 44(2): 287-301, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26438450

ABSTRACT

The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and patient functional anatomy. Numerical and experimental non-clinical assessments are included in the recommendations and requirements of several regulatory bodies and they are thus exploited in the analysis of stent fatigue performance. Optimization-based simulation methodologies have been developed as well, to improve the fatigue endurance of novel designs. This paper presents a review on the fatigue issue in metallic stents, starting from a description of clinical evidence about stent fracture up to the analysis of computational approaches available from the literature. The reported discussion on both the experimental and numerical framework aims at providing a general insight into stent lifetime prediction as well as at understanding the factors which affect stent fatigue performance for the design of novel components.


Subject(s)
Cardiovascular Diseases/surgery , Models, Theoretical , Stents , Stress, Mechanical , Humans
11.
Cell Death Dis ; 5: e1548, 2014 Dec 04.
Article in English | MEDLINE | ID: mdl-25476896

ABSTRACT

The functions of androgen receptor (AR) in stromal cells are still debated in spite of the demonstrated importance of these cells in organ development and diseases. Here, we show that physiological androgen concentration (10 nM R1881 or DHT) fails to induce DNA synthesis, while it consistently stimulates cell migration in mesenchymal and transformed mesenchymal cells. Ten nanomolar R1881 triggers p27 Ser10 phosphorylation and its stabilization in NIH3T3 fibroblasts. Activation of Rac and its downstream effector DYRK 1B is responsible for p27 Ser10 phosphorylation and cell quiescence. Ten nanomolar androgen also inhibits transformation induced by oncogenic Ras in NIH3T3 fibroblasts. Overexpression of an AR mutant unable to interact with filamin A, use of a small peptide displacing AR/filamin A interaction, and filamin A knockdown indicate that the androgen-triggered AR/filamin A complex regulates the pathway leading to p27 Ser10 phosphorylation and cell cycle arrest. As the AR/filamin A complex is also responsible for migration stimulated by 10 nM androgen, our report shows that the androgen-triggered AR/filamin A complex controls, through Rac 1, the decision of cells to halt cell cycle and migration. This study reveals a new and unexpected role of androgen/AR signalling in coordinating stromal cell functions.


Subject(s)
Dihydrotestosterone/pharmacology , Filamins/metabolism , Mesenchymal Stem Cells/metabolism , Receptors, Androgen/metabolism , Signal Transduction , rac1 GTP-Binding Protein/metabolism , Animals , Cell Cycle Checkpoints/drug effects , Cell Movement/drug effects , Cell Proliferation/drug effects , Cyclin-Dependent Kinase Inhibitor p27/genetics , Cyclin-Dependent Kinase Inhibitor p27/metabolism , Fibroblasts/cytology , Fibroblasts/drug effects , Fibroblasts/metabolism , Fibrosarcoma/genetics , Fibrosarcoma/metabolism , Fibrosarcoma/pathology , Filamins/genetics , Gene Expression Regulation , Humans , Male , Mesenchymal Stem Cells/cytology , Mesenchymal Stem Cells/drug effects , Metribolone/pharmacology , Mice , NIH 3T3 Cells , Phosphorylation , Prostatic Neoplasms/genetics , Prostatic Neoplasms/metabolism , Prostatic Neoplasms/pathology , Protein Serine-Threonine Kinases/genetics , Protein Serine-Threonine Kinases/metabolism , Protein-Tyrosine Kinases/genetics , Protein-Tyrosine Kinases/metabolism , Receptors, Androgen/genetics , Serine/metabolism , Testosterone Congeners/pharmacology , Tumor Cells, Cultured , rac1 GTP-Binding Protein/genetics , ras Proteins/genetics , ras Proteins/metabolism , Dyrk Kinases
12.
J Biomech ; 47(11): 2547-55, 2014 Aug 22.
Article in English | MEDLINE | ID: mdl-24998989

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is a minimally invasive procedure introduced to treat aortic valve stenosis in elder patients. Its clinical outcomes are strictly related to patient selection, operator skills, and dedicated pre-procedural planning based on accurate medical imaging analysis. The goal of this work is to define a finite element framework to realistically reproduce TAVI and evaluate the impact of aortic root anatomy on procedure outcomes starting from two real patient datasets. Patient-specific aortic root models including native leaflets, calcific plaques extracted from medical images, and an accurate stent geometry based on micro-tomography reconstruction are key aspects included in the present study. Through the proposed simulation strategy we observe that, in both patients, stent apposition significantly induces anatomical configuration changes, while it leads to different stress distributions on the aortic wall. Moreover, for one patient, a possible risk of paravalvular leakage has been found while an asymmetric coaptation occurs in both investigated cases. Post-operative clinical data, that have been analyzed to prove reliability of the performed simulations, show a good agreement with analysis results. The proposed work thus represents a further step towards the use of realistic computer-based simulations of TAVI procedures, aiming at improving the efficacy of the operation technique and supporting device optimization.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Aged, 80 and over , Calcinosis , Catheterization , Computer Simulation , Finite Element Analysis , Humans , Image Processing, Computer-Assisted , Male , Models, Anatomic , Reproducibility of Results , Stents , Tomography, X-Ray Computed
13.
Comput Methods Biomech Biomed Engin ; 17(12): 1347-57, 2014.
Article in English | MEDLINE | ID: mdl-23402555

ABSTRACT

Until recently, heart valve failure has been treated adopting open-heart surgical techniques and cardiopulmonary bypass. However, over the last decade, minimally invasive procedures have been developed to avoid high risks associated with conventional open-chest valve replacement techniques. Such a recent and innovative procedure represents an optimal field for conducting investigations through virtual computer-based simulations: in fact, nowadays, computational engineering is widely used to unravel many problems in the biomedical field of cardiovascular mechanics and specifically, minimally invasive procedures. In this study, we investigate a balloon-expandable valve and we propose a novel simulation strategy to reproduce its implantation using computational tools. Focusing on the Edwards SAPIEN valve in particular, we simulate both stent crimping and deployment through balloon inflation. The developed procedure enabled us to obtain the entire prosthetic device virtually implanted in a patient-specific aortic root created by processing medical images; hence, it allows evaluation of postoperative prosthesis performance depending on different factors (e.g. device size and prosthesis placement site). Notably, prosthesis positioning in two different cases (distal and proximal) has been examined in terms of coaptation area, average stress on valve leaflets as well as impact on the aortic root wall. The coaptation area is significantly affected by the positioning strategy (- 24%, moving from the proximal to distal) as well as the stress distribution on both the leaflets (+13.5%, from proximal to distal) and the aortic wall (- 22%, from proximal to distal). No remarkable variations of the stress state on the stent struts have been obtained in the two investigated cases.


Subject(s)
Aortic Valve/surgery , Finite Element Analysis , Heart Valve Prosthesis Implantation/methods , Aortic Valve/diagnostic imaging , Catheterization , Computer Simulation , Heart Valve Prosthesis , Humans , Male , Middle Aged , Models, Anatomic , Radiography , Stents
14.
Article in English | MEDLINE | ID: mdl-22553900

ABSTRACT

In some cases of aortic valve leaflet disease, the implant of a stentless biological prosthesis represents an excellent option for aortic valve replacement (AVR). In particular, if compared with the implant of mechanical valves, it provides a more physiological haemodynamic performance and a reduced thrombogeneticity, avoiding the use of anticoagulants. The clinical outcomes of AVR are strongly dependent on an appropriate choice of both prosthesis size and replacement technique, which is, at present, strictly related to surgeon's experience and skill. This represents the motivation for patient-specific finite element analysis able to virtually reproduce stentless valve implantation. With the aim of performing reliable patient-specific simulations, we remark that, on the one hand, it is not well established in the literature whether bioprosthetic leaflet tissue is isotropic or anisotropic; on the other hand, it is of fundamental importance to incorporate an accurate material model to realistically predict post-operative performance. Within this framework, using a novel computational methodology to simulate stentless valve implantation, we test the impact of using different material models on both the stress pattern and post-operative coaptation parameters (i.e. coaptation area, length and height). As expected, the simulation results suggest that the material properties of the valve leaflets affect significantly the post-operative prosthesis performance.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Aortic Valve/diagnostic imaging , Finite Element Analysis , Humans , Materials Testing , Models, Anatomic , Radiography , Stress, Mechanical
15.
Int J Numer Method Biomed Eng ; 29(6): 645-64, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23729192

ABSTRACT

Finite element analysis is nowadays a well-assessed technique to investigate the impact of stenting on vessel wall and, given the rapid progression of both medical imaging techniques and computational methods, the challenge of using the simulation of carotid artery stenting as procedure planning tool to support the clinical practice can be approached. Within this context, the present study investigates the impact of carotid stent apposition on carotid artery anatomy by means of patient-specific finite element analysis. In particular, we focus on the influence of the vessel constitutive model on the prediction of carotid artery wall tensional state of lumen gain and of vessel straightening. For this purpose, we consider, for a given stent design and CA anatomy, two constitutive models for the CA wall, that is, a hyperelastic isotropic versus a fiber-reinforced hyperelastic anisotropic model. Despite both models producing similar patterns with respect to stress distribution, the anisotropic model predicts a higher vessel straightening and a more evident discontinuity of the lumen area near the stent ends as observed in the clinical practice. Although still affected by several simplifications, the present study can be considered as further step toward a realistic simulation of carotid artery stenting.


Subject(s)
Carotid Arteries/anatomy & histology , Carotid Arteries/pathology , Models, Cardiovascular , Precision Medicine/instrumentation , Precision Medicine/methods , Stents , Aged , Angiography , Computer Simulation , Female , Finite Element Analysis , Humans , Image Processing, Computer-Assisted/methods , Prosthesis Design , Tomography, X-Ray Computed
16.
Comput Biol Med ; 43(4): 386-94, 2013 May.
Article in English | MEDLINE | ID: mdl-23395199

ABSTRACT

Traditional surgical repair of ascending aortic pseudoaneurysm is complex, technically challenging, and associated with significant mortality. Although new minimally invasive procedures are rapidly arising thanks to the innovations in catheter-based technologies, the endovascular repair of the ascending aorta is still limited because of the related anatomical challenges. In this context, the integration of the clinical considerations with dedicated bioengineering analysis, combining the vascular features and the prosthesis design, might be helpful to plan the procedure and predict its outcome. Moving from such considerations, in the present study we describe the use of a custom-made stent-graft to perform a fully endovascular repair of an asymptomatic ascending aortic pseudoaneurysm in a patient, who was a poor candidate for open surgery. We also discuss the possible contribution of a dedicated medical images analysis and patient-specific simulation as support to procedure planning. In particular, we have compared the simulation prediction based on pre-operative images with post-operative outcomes. The agreement between the computer-based analysis and reality encourages the use of the proposed approach for a careful planning of the treatment strategy and for an appropriate patient selection, aimed at achieving successful outcomes for endovascular treatment of ascending aortic pseudoaneurysms as well as other aortic diseases.


Subject(s)
Aneurysm, False/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Cardiology/methods , Aged , Aorta/pathology , Aortic Diseases/surgery , Biomechanical Phenomena , Blood Vessel Prosthesis , Computer Simulation , Endovascular Procedures , Female , Finite Element Analysis , Humans , Stents
17.
Article in English | MEDLINE | ID: mdl-22149183

ABSTRACT

Carotid artery stenting (CAS) has emerged as a minimally invasive alternative to endarterectomy but its use in clinical treatment is limited due to the post-stenting complications. Haemodynamic actors, related to blood flow in the stented vessel, have been suggested to play a role in the endothelium response to stenting, including adverse reactions such as in-stent restenosis and late thrombosis. Accessing the flow-related shear forces acting on the endothelium in vivo requires space and time resolutions which are currently not achievable with non-invasive clinical imaging techniques but can be obtained from image-based computational analysis. In this study, we present a framework for accurate determination of the wall shear stress (WSS) in a mildly stenosed carotid artery after the implantation of a stent, resembling the commercially available Acculink (Abbott Laboratories, Abbott Park, Illinois, USA). Starting from angiographic CT images of the vessel lumen and a micro-CT scan of the stent, a finite element analysis is carried out in order to deploy the stent in the vessel, reproducing CAS in silico. Then, based on the post-stenting anatomy, the vessel is perfused using a set of boundary conditions: total pressure is applied at the inlet, and impedances that are assumed to be insensitive to the presence of the stent are imposed at the outlets. Evaluation of the CAS outcome from a geometrical and haemodynamic perspective shows the presence of atheroprone regions (low time-average WSS, high relative residence time) colocalised with stent malapposition and stent strut interconnections. Stent struts remain unapposed in the ostium of the external carotid artery disturbing the flow and generating abnormal shear forces, which could trigger thromboembolic events.


Subject(s)
Carotid Arteries/surgery , Stents , Biomechanical Phenomena , Carotid Arteries/physiopathology , Carotid Stenosis/surgery , Computer Simulation , Finite Element Analysis , Hemodynamics , Humans , Stents/adverse effects , Stress, Mechanical
18.
J Mech Behav Biomed Mater ; 15: 78-92, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23032428

ABSTRACT

Cardiovascular disease has become a major global health care problem in the present decade. To tackle this problem, the use of cardiovascular stents has been considered a promising and effective approach. Numerical simulations to evaluate the in vivo behavior of stents are becoming more and more important to assess potential failures. As the material failure of a stent device has been often associated with fatigue issues, as a result of the high number of cyclic loads these devices are subjected to in vivo, numerical approaches for fatigue life assessment of stents has gained special interest in the engineering community. Numerical fatigue predictions can be used to modify the design and prevent failure, without making and testing numerous physical devices, thus preventing from undesired fatigue failures. This work presents a fatigue life numerical method for the analysis of cardiovascular balloon-expandable stainless steel stents. The method is based on a two-scale continuum damage mechanics model in which both plasticity and damage mechanisms are assumed to take place at a scale smaller than the scale of the representative volume element. The fatigue failure criterion is based on the Soderberg relation. The method is applied to the fatigue life assessment of both PalmazShatz and Cypher stent designs. Validation of the method is performed through comparison of the obtained numerical results with some experimental results available for the PalmazShatz stent design. The present study gives also possible directions for future research developments in the framework of the numerical fatigue life assessment of real balloon-expandable stents.


Subject(s)
Cardiovascular System , Finite Element Analysis , Mechanical Phenomena , Stents , Time Factors
19.
Int J Numer Method Biomed Eng ; 28(10): 1043-55, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23027634

ABSTRACT

After carotid artery stenting, the plaque remains contained between the stent and the vessel wall, moving consequently physicians' concerns toward the stent capability of limiting the plaque protrusion, that is, toward vessel scaffolding, to avoid that some debris is dislodged after the procedure. Vessel scaffolding is usually measured as the cell area of the stent in free-expanded configuration, neglecting thus the actual stent configuration within the vascular anatomy. In the present study, we measure the cell area of four different stent designs deployed in a realistic carotid artery model through patient-specific finite element analysis. The results suggest that after deployment, the cell area change along the stent length and the related reduction with respect to the free-expanded configuration are functions of the vessel tapering. Hence, the conclusions withdrawn from the free-expanded configuration appear to be qualitatively acceptable for comparative purposes, but they should be carefully handled because they neglect the post-implant variability, which seems to be more pronounced in open-cell designs, especially at the bifurcation segment. Even though the investigation is limited to few stent designs and one vascular anatomy, our study confirms the capability of dedicated computer-based simulations to provide useful information about complex stent features as vessel scaffolding.


Subject(s)
Carotid Stenosis/pathology , Carotid Stenosis/surgery , Models, Cardiovascular , Stents , Biomedical Engineering , Carotid Stenosis/diagnostic imaging , Computer Simulation , Finite Element Analysis , Humans , Models, Neurological , Prosthesis Design/statistics & numerical data , Stents/statistics & numerical data , Tomography, X-Ray Computed
20.
Oncogene ; 31(46): 4868-77, 2012 Nov 15.
Article in English | MEDLINE | ID: mdl-22266855

ABSTRACT

We report that in breast cancer cells, tyrosine phosphorylation of the estradiol receptor alpha (ERalpha) by Src regulates cytoplasmic localization of the receptor and DNA synthesis. Inhibition of Src or use of a peptide mimicking the ERalpha p-Tyr537 sequence abolishes ERalpha tyrosine phosphorylation and traps the receptor in nuclei of estradiol-treated MCF-7 cells. An ERalpha mutant carrying a mutation of Tyr537 to phenylalanine (ER537F) persistently localizes in nuclei of various cell types. In contrast with ERalpha wt, ER537F does not associate with Ran and its interaction with Crm1 is insensitive to estradiol. Thus, independently of estradiol, ER537F is retained in nuclei, where it entangles FKHR-driving cell cycle arrest. Chromatin immunoprecipitation analysis reveals that overexpression of ER537F in breast cancer cells enhances FKHR interaction with cyclin D1 promoter. This mutant also counteracts cell transformation by the activated forms of Src or PI3-K. In conclusion, in addition to regulating receptor localization, ERalpha phosphorylation by Src is required for hormone responsiveness of DNA synthesis in breast cancer cells.


Subject(s)
Breast Neoplasms/metabolism , Cell Cycle Checkpoints/physiology , Estradiol/metabolism , Estrogen Receptor alpha/metabolism , Tyrosine/metabolism , src-Family Kinases/metabolism , Active Transport, Cell Nucleus , Animals , Breast Neoplasms/enzymology , Breast Neoplasms/genetics , Breast Neoplasms/pathology , COS Cells , Cell Cycle Checkpoints/genetics , Cell Growth Processes/genetics , Cell Growth Processes/physiology , Cell Line , Cell Line, Tumor , Cell Nucleus/genetics , Cell Nucleus/metabolism , Chlorocebus aethiops , Cyclin D1/genetics , Cyclin D1/metabolism , Cytoplasm/genetics , Cytoplasm/metabolism , Estrogen Receptor alpha/genetics , Female , Forkhead Transcription Factors/genetics , Forkhead Transcription Factors/metabolism , Humans , Karyopherins/genetics , Karyopherins/metabolism , MCF-7 Cells , Mice , Mutation , NIH 3T3 Cells , Phenylalanine/genetics , Phenylalanine/metabolism , Phosphatidylinositol 3-Kinases/genetics , Phosphatidylinositol 3-Kinases/metabolism , Phosphorylation , Promoter Regions, Genetic , Receptors, Cytoplasmic and Nuclear/genetics , Receptors, Cytoplasmic and Nuclear/metabolism , S Phase/genetics , Transcription, Genetic , Tyrosine/genetics , ran GTP-Binding Protein/genetics , ran GTP-Binding Protein/metabolism , src-Family Kinases/genetics , Exportin 1 Protein
SELECTION OF CITATIONS
SEARCH DETAIL
...