Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 17(6): e0269805, 2022.
Article in English | MEDLINE | ID: mdl-35679310

ABSTRACT

Carotid atherosclerotic plaque rupture and its sequelae are among the leading causes of acute ischemic stroke. The risk of rupture and subsequent thrombosis is, among others, determined by vulnerable plaque characteristics and linked to activation of the immune system, in which neutrophil extracellular traps (NETs) potentially play a role. The aim of this study was to investigate how plaque vulnerability is associated with NETs levels. We included 182 patients from the Plaque At RISK (PARISK) study in whom carotid imaging was performed to measure plaque ulceration, fibrous cap integrity, intraplaque hemorrhage, lipid-rich necrotic core, calcifications and plaque volume. Principal component analysis generated a 'vulnerability index' comprising all plaque characteristics. Levels of the NETs marker myeloperoxidase-DNA complex were measured in patient plasma. The association between the vulnerability index and low or high NETs levels (dependent variable) was assessed by logistic regression. No significant association between the vulnerability index and NETs levels was detected in the total population (odds ratio 1.28, 95% confidence interval 0.90-1.83, p = 0.18). However, in the subgroup of patients naive to statins or antithrombotic medication prior to the index event, this association was statistically significant (odds ratio 2.08, 95% confidence interval 1.04-4.17, p = 0.04). Further analyses revealed that this positive association was mainly driven by intraplaque hemorrhage, lipid-rich necrotic core and ulceration. In conclusion, plaque vulnerability is positively associated with plasma levels of NETs, but only in patients naive to statins or antithrombotic medication prior to the index event.


Subject(s)
Carotid Stenosis , Extracellular Traps , Hydroxymethylglutaryl-CoA Reductase Inhibitors , Ischemic Stroke , Plaque, Atherosclerotic , Stroke , Carotid Arteries , Carotid Stenosis/complications , Fibrinolytic Agents , Hemorrhage/etiology , Humans , Lipids , Magnetic Resonance Imaging/methods , Necrosis , Plaque, Atherosclerotic/complications , Risk Factors , Stroke/complications
2.
Sci Rep ; 10(1): 2173, 2020 02 07.
Article in English | MEDLINE | ID: mdl-32034227

ABSTRACT

Extensive application of coronary intravascular procedures has led to the increased need of understanding the injury inflicted to the coronary arterial wall. We aimed to investigate acute and prolonged coronary endothelial injury as a result of guidewire use, repeated intravascular imaging and stenting. These interventions were performed in swine (N = 37) and injury was assessed per coronary segment (n = 81) using an Evans Blue dye-exclusion-test. Scanning electron microscopy and light microscopy were then used to visualize the extent and nature of acute (<4 hours) and prolonged (5 days) endothelial injury. Guidewire and imaging injury was mainly associated with denudation and returned to control levels at 5 days. IVUS and OCT combined (Evans Blue staining 28 ± 16%) did not lead to more acute injury than IVUS alone (33 ± 15%). Stent placement caused most injury (85 ± 4%) and despite early stent re-endothelialization at 5 days, the endothelium proved highly permeable (97 ± 4% at 5 days; p < 0.001 vs acute). Imaging of in-stent neointima at 28 days after stent placement did not lead to neointimal rupture. Guidewire, IVUS and OCT induce acute endothelial cell damage, which does not increase during repeated imaging, and heals within 5 days. Interestingly, endothelial permeability increases 5 days post stenting despite near complete re-endothelialization.


Subject(s)
Coronary Vessels/injuries , Drug-Eluting Stents/adverse effects , Neointima/pathology , Percutaneous Coronary Intervention/adverse effects , Postoperative Complications/pathology , Animals , Neointima/diagnostic imaging , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Postoperative Complications/etiology , Swine , Tomography, Optical Coherence/adverse effects , Tomography, Optical Coherence/methods , Ultrasonography, Interventional/adverse effects , Ultrasonography, Interventional/methods
3.
J Am Heart Assoc ; 7(13)2018 06 22.
Article in English | MEDLINE | ID: mdl-29934420

ABSTRACT

BACKGROUND: Currently, acute ischemic stroke is still a leading cause of mortality and morbidity. Approximately 2 years ago, mechanical thrombectomy was proven beneficial as a revolutionary new therapy for stroke in the MR-CLEAN trial (A Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands). However, the mechanisms by which the thrombectomy device, or stent-retriever, interacts with the thrombus are largely unknown. A better understanding could lead to improved efficacy of mechanical thrombectomy devices. METHODS AND RESULTS: Seven stent-retrievers with thrombi still entrapped were collected directly after thrombectomy. The stent-retrievers were studied using micro computed tomography, followed by scanning electron microscopy and light microscopy. Two independent observers rated interaction type and thrombus surface structure (porous filamentous or dense) at the interaction sites.A total of 79 interaction sites between thrombus and stent-retriever were categorized. Thrombus-stent-retriever interaction was found to be adhesive (n=44; 56%) or mechanical (n=35; 44%). Adhesive interaction was most frequently observed at interaction sites with a dense surface, compared with interaction sites with a porous filamentous fibrin surface (38/58; 66% versus 6/21; 29%, P=0.011). CONCLUSIONS: The interaction between thrombus and stent-retriever was predominantly adhesive, not mechanical. Adhesive interaction was strongly associated with the presence of a dense thrombus surface without a porous filamentous fibrin network.


Subject(s)
Brain Ischemia/therapy , Intracranial Thrombosis/therapy , Microscopy, Electron, Scanning , Stents , Stroke/therapy , Thrombectomy/instrumentation , X-Ray Microtomography , Adhesiveness , Brain Ischemia/diagnostic imaging , Brain Ischemia/pathology , Humans , Intracranial Thrombosis/diagnostic imaging , Intracranial Thrombosis/pathology , Netherlands , Porosity , Prospective Studies , Prosthesis Design , Registries , Stroke/diagnostic imaging , Stroke/pathology , Surface Properties , Thrombolytic Therapy
5.
PLoS One ; 12(5): e0176472, 2017.
Article in English | MEDLINE | ID: mdl-28486563

ABSTRACT

BACKGROUND: Multiple inducers of in vitro Neutrophil Extracellular Trap (NET) formation (NETosis) have been described. Since there is much variation in study design and results, our aim was to create a systematic review of NETosis inducers and perform a standardized in vitro study of NETosis inducers important in (cardiac) wound healing. METHODS: In vitro NETosis was studied by incubating neutrophils with PMA, living and dead bacteria (S. aureus and E. coli), LPS, (activated) platelets (supernatant), glucose and calcium ionophore Ionomycin using 3-hour periods of time-lapse confocal imaging. RESULTS: PMA is a consistent and potent inducer of NETosis. Ionomycin also consistently resulted in extrusion of DNA, albeit with a process that differs from the NETosis process induced by PMA. In our standardized experiments, living bacteria were also potent inducers of NETosis, but dead bacteria, LPS, (activated) platelets (supernatant) and glucose did not induce NETosis. CONCLUSION: Our systematic review confirms that there is much variation in study design and results of NETosis induction. Our experimental results confirm that under standardized conditions, PMA, living bacteria and Ionomycin all strongly induce NETosis, but real-time confocal imaging reveal different courses of events.


Subject(s)
Extracellular Traps , Escherichia coli/physiology , Fluorescent Antibody Technique , Humans , In Vitro Techniques , Myocardium/pathology , Staphylococcus aureus/physiology , Wound Healing
7.
Circ Cardiovasc Interv ; 8(5)2015 May.
Article in English | MEDLINE | ID: mdl-25969547

ABSTRACT

BACKGROUND: As bioresorbable vascular scaffolds (BVSs) are being increasingly used in complex real-world lesions and populations, BVS thrombosis cases have been reported. We present angiographic and optical coherence tomography (OCT) findings in a series of patients treated in our center for definite bioresorbable scaffold thrombosis. METHODS AND RESULTS: Up to June 2014, 14 patients presented with definite BVS thrombosis in our center. OCT was performed in 9 patients at the operator's discretion. Angiographic and OCT findings were compared with a control group comprising 15 patients with definite metallic stent thrombosis. In the BVS group, time interval from index procedure to scaffold thrombosis ranged from 0 to 675 days. Incomplete lesion coverage by angiography was identified in 4 of 14 cases, malapposition by OCT in 5 of 9 cases, strut discontinuity in 2 of 9 cases, and underexpansion in 2 of 9 cases. Five patients had discontinued dual antiplatelet therapy, and in 3 of them discontinued dual antiplatelet therapy discontinuation had occurred the week preceding the event. There were no significant differences in angiographic or OCT findings between BVS and metallic stent thrombosis. CONCLUSIONS: Suboptimal implantation with incomplete lesion coverage, underexpansion, and malapposition comprises the main pathomechanism for both early and late BVS thrombosis, similar to metallic stent thrombosis. Dual antiplatelet therapy discontinuation seems to also be a secondary contributor in several late events. Our observations suggest that several potential triggers for BVS thrombosis could be avoided.


Subject(s)
Absorbable Implants/adverse effects , Coronary Angiography , Coronary Artery Disease/therapy , Coronary Thrombosis/diagnosis , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents/adverse effects , Immunosuppressive Agents/administration & dosage , Tissue Scaffolds , Tomography, Optical Coherence , Aged , Coronary Thrombosis/etiology , Everolimus/administration & dosage , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...