Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Lett ; 45(23): 6350-6353, 2020 Dec 01.
Article in English | MEDLINE | ID: mdl-33258809

ABSTRACT

We present a carrier-envelope offset (CEO) stable ytterbium-doped fiber chirped-pulse amplification system employing the technology of coherent beam combining and delivering more than 1 kW of average power at a pulse repetition rate of 80 MHz. The CEO stability of the system is 220 mrad rms, characterized out-of-loop with an f-to-2f interferometer in a frequency offset range of 10 Hz to 20 MHz. The high-power amplification system boosts the average power of the CEO stable oscillator by five orders of magnitude while increasing the phase noise by only 100 mrad. No evidence of CEO noise deterioration due to coherent beam combining is found. Low-frequency CEO fluctuations at the chirped-pulse amplifier are suppressed by a "slow loop" feedback. To the best of our knowledge, this is the first demonstration of a coherently combined laser system delivering an outstanding average power and high CEO stability at the same time.

2.
Opt Express ; 25(6): 6690-6699, 2017 Mar 20.
Article in English | MEDLINE | ID: mdl-28381013

ABSTRACT

The spectral phase noise of a cryogenically cooled Ti:Sapphire amplifier was analyzed by spectrally resolved interferometry. Since a relative phase difference measurement is performed, the effect of the amplifier stage can be determined with high precision. Contributions of the cooling system to the spectral phase noise were found to be below 50 mrad for both the vacuum pumps and the cryogenic system. The carrier-envelope phase noise of thermal and mechanical origin was also determined for different repetition rates of laser operation. Mechanical vibrational spectra were recorded by an accelerometer for different stages of operation and compared to the interferometric phase noise measurements.

3.
Opt Lett ; 39(20): 5913-6, 2014 Oct 15.
Article in English | MEDLINE | ID: mdl-25361118

ABSTRACT

Carrier-envelope phase (CEP) drift of a pulse train of 2 ps pulses has been measured by a multiple beam interferometer. The round trip time of the interferometer is slightly mistuned from the pulse sequence, leading to spectral interference fringes. We extract the pulse-to-pulse CEP drift from the position of the spectral interference pattern. The length of the interferometer has been actively stabilized to ±10 nm, which sets the ultimate limit on the accuracy of the measurement to 78 mrad, while the CEP-drift (rms) noise of the measurement was 127 mrad (at 800 nm).

4.
Opt Lett ; 38(4): 410-2, 2013 Feb 15.
Article in English | MEDLINE | ID: mdl-23455085

ABSTRACT

Misalignment of the stretcher-compressor stages of chirped pulse amplification (CPA) lasers can aggravate the spatiotemporal shape of ultrashort pulses. We demonstrate a simple technique for angular dispersion measurement, which offers real-time single-shot two-dimensional characterization across the entire beam profile. The accuracy of our pilot experiment approaches its current theoretical limit of 0.1 µrad/nm. Unlike the current one-dimensional techniques working in the near field, the method works in the far field; hence, it is especially appropriate for assisting the most accurate alignment of a CPA laser compressor ensuring the maximum intensity on the target.

5.
Appl Opt ; 52(34): 8376-80, 2013 Dec 01.
Article in English | MEDLINE | ID: mdl-24513841

ABSTRACT

We report on the first demonstration, to the best of our knowledge, of the locking of a Fabry-Perot cavity with a finesse of 28,000 in the pulsed regime. The system is based on a stable picosecond oscillator, an ultrastable cavity with high-reflection mirrors, and an all-numerical feedback system that allows efficient and independent control of the repetition rate and the pulse to pulse carrier-to-envelop phase drift (CEP). We show that the carrier to envelop phase can have a dramatic effect even for pulses with hundreds of cycles. Moreover, we have succeeded in unambiguously measuring the CEP of a 2 ps pulse train. Finally, we discuss the potential of our findings to reach the MW average power level stored in an external cavity enhancement architecture.

6.
Opt Lett ; 37(5): 836-8, 2012 Mar 01.
Article in English | MEDLINE | ID: mdl-22378410

ABSTRACT

A bandwidth-independent and linear interferometric method for the measurement of the carrier-envelope phase drift of ultrashort pulse trains is demonstrated. The pulses are temporally overlapped in a resonant multiple-beam interferometer. From the position of the spectral interference pattern, the relative carrier-envelope phase between two subsequent oscillator pulses is obtained at data acquisition rates up to 200 Hz. Cross calibration has been performed by f-to-2f interferometry in two independent experiments. The optical length of the interferometer has been actively stabilized, leading to a phase jitter of 117 mrad (rms). These results indicate a reduced noise and quicker data acquisition in comparison with previous linear methods for measuring the carrier-envelope phase drift.

7.
Opt Express ; 18(25): 25847-54, 2010 Dec 06.
Article in English | MEDLINE | ID: mdl-21164930

ABSTRACT

The propagation of high intensity laser beams is excessively affected by optical nonlinear effects, thereby the knowledge of the nonlinear refractive indices of the beam guiding media is indispensable in the design of laser systems and experiments. Apart from undesired self-focusing, several areas of modern laser spectroscopy can utilize optical nonlinearity, from LiDAR measurements to filamentation. In this paper we report on a direct measurement of pressure dependent nonlinear refractive index of Ar, N2, Ne, Xe, and air between 0.05 mbar and 1 bar, based on the powerful technique called spectrally and spatially resolved interferometry. In this way the total value of nonlinear refractive index is measured, that is the sum of all elementary phenomena contributing to the intensity dependent refractivity of the gases.


Subject(s)
Materials Testing/instrumentation , Noble Gases/chemistry , Refractometry/instrumentation , Equipment Design , Equipment Failure Analysis , Nonlinear Dynamics , Pressure
8.
Opt Express ; 17(25): 22358-65, 2009 Dec 07.
Article in English | MEDLINE | ID: mdl-20052159

ABSTRACT

The preservation of carrier envelope phase (CEP) during Cross-Polarized Wave Generation (XPWG) is demonstrated through two independent experiments based on the spatially and spectrally resolved interference fringes formed by the XPW beam and its fundamental. In a first measurement, we found that the vertical fringe position on the spatial detector was maintained over many consecutive laser shots, implying practically no change in relative CEP between the XPW and the fundamental. In a second experiment, we measured the change in relative CEP between the XPW and fundamental beam by systematically varying the amount of material dispersion inside the XPW arm of the interferometer. The recorded rate of relative phase change was in excellent agreement with the theoretical value.


Subject(s)
Lasers , Models, Theoretical , Refractometry/methods , Telecommunications , Computer Simulation , Light , Scattering, Radiation
9.
Appl Opt ; 47(27): 4856-63, 2008 Sep 20.
Article in English | MEDLINE | ID: mdl-18806842

ABSTRACT

Dispersion of femtosecond laser pulses propagating in Ar, He, Kr, N(2), Ne, Xe, and their mixtures is measured by spectrally and spatially resolved interferometry. By varying the gas pressure in a 4.5 m long tube between 0.05 mbar and ambient pressure, the first, second, and third order phase derivatives of broadband laser pulses are determined at 800 nm under standard conditions. The dispersion of gases and gas mixtures obeys the Lorentz-Lorenz formula with an accuracy of 0.7%. Based on the measured pressure dependent dispersion values in the near infrared and the refractive indices available from the literature for the ultraviolet and visible, a pressure dependent Sellmeier-type formula is fitted for each gas. These common form, two-term dispersion equations provide an accuracy between 4.1x10(-9) (Ne) and 4.3x10(-7) (Xe) for the refractive indices, from UV to near IR.


Subject(s)
Algorithms , Interferometry/methods , Models, Chemical , Noble Gases/chemistry , Refractometry/methods , Complex Mixtures/analysis , Complex Mixtures/chemistry , Computer Simulation , Light , Noble Gases/analysis , Scattering, Radiation
SELECTION OF CITATIONS