1.
Phys Med Biol ; 68(8)2023 04 12.
Article in English | MEDLINE | ID: mdl-36963115

ABSTRACT

Objective.To evaluate the performance of two photon-counting (PC) detectors based on different detector materials, gallium arsenide (GaAs) and cadmium telluride (CdTe), for PC micro-CT imaging of phantoms with multiple contrast materials. Another objective is to determine if combining these two detectors in the same micro-CT system can offer higher spectral performance and significant artifact reduction compared to a single detector system.Approach. We have constructed a dual-detector, micro-CT system equipped with two PCDs based on different detector materials: gallium arsenide (GaAs) and cadmium telluride (CdTe). We demonstrate the performance of these detectors for PC micro-CT imaging of phantoms with up to 5 contrast materials with K-edges spread across the x-ray spectrum ranging from iodine with a K-edge at 33.2 keV to bismuth with a K-edge at 90.5 keV. We also demonstrate the use of our system to image a mouse prepared with both iodine and bismuth contrast agents to target different biological systems.Main results.When using the same dose and scan parameters, GaAs shows increased low energy (<50 keV) spectral sensitivity and specificity compared to CdTe. However, GaAs performance at high energies suffers from spectral artifacts and has comparatively low photon counts indicating wasted radiation dose. We demonstrate that combining a GaAs-based and a CdTe-based PC detector in the same micro-CT system offers higher spectral performance and significant artifact reduction compared to a single detector system.Significance.More accurate PC micro-CT using a GaAs PCD alone or in combination with a CdTe PCD could serve for developing new contrast agents such as nanoparticles that show promise in the developing field of theranostics (therapy and diagnostics).


Subject(s)
Cadmium Compounds , Iodine , Quantum Dots , Animals , Mice , X-Ray Microtomography/methods , Contrast Media , Tellurium , Bismuth
2.
Phys Med ; 88: 175-192, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34284331

ABSTRACT

PURPOSE: Micron-scale computed tomography (micro-CT) imaging is a ubiquitous, cost-effective, and non-invasive three-dimensional imaging modality. We review recent developments and applications of micro-CT for preclinical research. METHODS: Based on a comprehensive review of recent micro-CT literature, we summarize features of state-of-the-art hardware and ongoing challenges and promising research directions in the field. RESULTS: Representative features of commercially available micro-CT scanners and some new applications for both in vivo and ex vivo imaging are described. New advancements include spectral scanning using dual-energy micro-CT based on energy-integrating detectors or a new generation of photon-counting x-ray detectors (PCDs). Beyond two-material discrimination, PCDs enable quantitative differentiation of intrinsic tissues from one or more extrinsic contrast agents. When these extrinsic contrast agents are incorporated into a nanoparticle platform (e.g. liposomes), novel micro-CT imaging applications are possible such as combined therapy and diagnostic imaging in the field of cancer theranostics. Another major area of research in micro-CT is in x-ray phase contrast (XPC) imaging. XPC imaging opens CT to many new imaging applications because phase changes are more sensitive to density variations in soft tissues than standard absorption imaging. We further review the impact of deep learning on micro-CT. We feature several recent works which have successfully applied deep learning to micro-CT data, and we outline several challenges specific to micro-CT. CONCLUSIONS: All of these advancements establish micro-CT imaging at the forefront of preclinical research, able to provide anatomical, functional, and even molecular information while serving as a testbench for translational research.


Subject(s)
Contrast Media , Photons , Animals , Phantoms, Imaging , Tomography Scanners, X-Ray Computed , X-Ray Microtomography
3.
Phys Med Biol ; 65(20): 205012, 2020 10 21.
Article in English | MEDLINE | ID: mdl-32702686

ABSTRACT

Preclinical micro-CT provides a hotbed in which to develop new imaging technologies, including spectral CT using photon counting detector (PCD) technology. Spectral imaging using PCDs promises to expand x-ray CT as a functional imaging modality, capable of molecular imaging, while maintaining CT's role as a powerful anatomical imaging modality. However, the utility of PCDs suffers due to distorted spectral measurements, affecting the accuracy of material decomposition. We attempt to improve material decomposition accuracy using our novel hybrid dual-source micro-CT system which combines a PCD and an energy integrating detector. Comparisons are made between PCD-only and hybrid CT results, both reconstructed with our iterative, multi-channel algorithm based on the split Bregman method and regularized with rank-sparse kernel regression. Multi-material decomposition is performed post-reconstruction for separation of iodine (I), gold (Au), gadolinium (Gd), and calcium (Ca). System performance is evaluated first in simulations, then in micro-CT phantoms, and finally in an in vivo experiment with a genetically modified p53fl/fl mouse cancer model with Au, Gd, and I nanoparticle (NP)-based contrasts agents. Our results show that the PCD-only and hybrid CT reconstructions offered very similar spatial resolution at 10% MTF (PCD: 3.50 lp mm-1; hybrid: 3.47 lp mm-1) and noise characteristics given by the noise power spectrum. For material decomposition we note successful separation of the four basis materials. We found that hybrid reconstruction reduces RMSE by an average of 37% across all material maps when compared to PCD-only of similar dose but does not provide much difference in terms of concentration accuracy. The in vivo results show separation of targeted Au and accumulated Gd NPs in the tumor from intravascular iodine NPs and bone. Hybrid spectral micro-CT can benefit nanotechnology and cancer research by providing quantitative imaging to test and optimize various NPs for diagnostic and therapeutic applications.


Subject(s)
Algorithms , Contrast Media , Phantoms, Imaging , Photons , Sarcoma, Experimental/diagnostic imaging , Sarcoma/diagnostic imaging , X-Ray Microtomography/instrumentation , Animals , Gadolinium , Humans , Image Processing, Computer-Assisted , Iodine , Mice , Sarcoma/chemically induced , Sarcoma/pathology , Sarcoma, Experimental/chemically induced , Sarcoma, Experimental/pathology
4.
Tomography ; 6(1): 23-33, 2020 03.
Article in English | MEDLINE | ID: mdl-32280747

ABSTRACT

Small-animal imaging is an essential tool that provides noninvasive, longitudinal insight into novel cancer therapies. However, considerable variability in image analysis techniques can lead to inconsistent results. We have developed quantitative imaging for application in the preclinical arm of a coclinical trial by using a genetically engineered mouse model of soft tissue sarcoma. Magnetic resonance imaging (MRI) images were acquired 1 day before and 1 week after radiation therapy. After the second MRI, the primary tumor was surgically removed by amputating the tumor-bearing hind limb, and mice were followed for up to 6 months. An automatic analysis pipeline was used for multicontrast MRI data using a convolutional neural network for tumor segmentation followed by radiomics analysis. We then calculated radiomics features for the tumor, the peritumoral area, and the 2 combined. The first radiomics analysis focused on features most indicative of radiation therapy effects; the second radiomics analysis looked for features that might predict primary tumor recurrence. The segmentation results indicated that Dice scores were similar when using multicontrast versus single T2-weighted data (0.863 vs 0.861). One week post RT, larger tumor volumes were measured, and radiomics analysis showed greater heterogeneity. In the tumor and peritumoral area, radiomics features were predictive of primary tumor recurrence (AUC: 0.79). We have created an image processing pipeline for high-throughput, reduced-bias segmentation of multiparametric tumor MRI data and radiomics analysis, to better our understanding of preclinical imaging and the insights it provides when studying new cancer therapies.


Subject(s)
Deep Learning , Magnetic Resonance Imaging/methods , Sarcoma/diagnostic imaging , Soft Tissue Neoplasms/diagnostic imaging , Animals , Mice , Neoplasm Recurrence, Local
5.
PLoS One ; 15(2): e0225019, 2020.
Article in English | MEDLINE | ID: mdl-32097413

ABSTRACT

Small animal imaging has become essential in evaluating new cancer therapies as they are translated from the preclinical to clinical domain. However, preclinical imaging faces unique challenges that emphasize the gap between mouse and man. One example is the difference in breathing patterns and breath-holding ability, which can dramatically affect tumor burden assessment in lung tissue. As part of a co-clinical trial studying immunotherapy and radiotherapy in sarcomas, we are using micro-CT of the lungs to detect and measure metastases as a metric of disease progression. To effectively utilize metastatic disease detection as a metric of progression, we have addressed the impact of respiratory gating during micro-CT acquisition on improving lung tumor detection and volume quantitation. Accuracy and precision of lung tumor measurements with and without respiratory gating were studied by performing experiments with in vivo images, simulations, and a pocket phantom. When performing test-retest studies in vivo, the variance in volume calculations was 5.9% in gated images and 15.8% in non-gated images, compared to 2.9% in post-mortem images. Sensitivity of detection was examined in images with simulated tumors, demonstrating that reliable sensitivity (true positive rate (TPR) ≥ 90%) was achievable down to 1.0 mm3 lesions with respiratory gating, but was limited to ≥ 8.0 mm3 in non-gated images. Finally, a clinically-inspired "pocket phantom" was used during in vivo mouse scanning to aid in refining and assessing the gating protocols. Application of respiratory gating techniques reduced variance of repeated volume measurements and significantly improved the accuracy of tumor volume quantitation in vivo.


Subject(s)
Lung Neoplasms/diagnostic imaging , Respiratory-Gated Imaging Techniques/methods , X-Ray Microtomography/methods , Animals , Data Accuracy , Disease Models, Animal , Lung Volume Measurements , Mice , Mice, Inbred C57BL , Mice, Transgenic , Phantoms, Imaging , Sensitivity and Specificity , X-Ray Microtomography/instrumentation
6.
PLoS One ; 14(4): e0207555, 2019.
Article in English | MEDLINE | ID: mdl-30958825

ABSTRACT

In designing co-clinical cancer studies, preclinical imaging brings unique challenges that emphasize the gap between man and mouse. Our group is developing quantitative imaging methods for the preclinical arm of a co-clinical trial studying immunotherapy and radiotherapy in a soft tissue sarcoma model. In line with treatment for patients enrolled in the clinical trial SU2C-SARC032, primary mouse sarcomas are imaged with multi-contrast micro-MRI (T1 weighted, T2 weighted, and T1 with contrast) before and after immune checkpoint inhibition and pre-operative radiation therapy. Similar to the patients, after surgery the mice will be screened for lung metastases with micro-CT using respiratory gating. A systems evaluation was undertaken to establish a quantitative baseline for both the MR and micro-CT systems against which others systems might be compared. We have constructed imaging protocols which provide clinically-relevant resolution and contrast in a genetically engineered mouse model of sarcoma. We have employed tools in 3D Slicer for semi-automated segmentation of both MR and micro-CT images to measure tumor volumes efficiently and reliably in a large number of animals. Assessment of tumor burden in the resulting images was precise, repeatable, and reproducible. Furthermore, we have implemented a publicly accessible platform for sharing imaging data collected during the study, as well as protocols, supporting information, and data analyses. In doing so, we aim to improve the clinical relevance of small animal imaging and begin establishing standards for preclinical imaging of tumors from the perspective of a co-clinical trial.


Subject(s)
Lung Neoplasms/diagnostic imaging , Multimodal Imaging , Sarcoma/diagnostic imaging , Tumor Burden , X-Ray Microtomography , Animals , Humans , Lung Neoplasms/pathology , Lung Neoplasms/secondary , Mice , Neoplasm Metastasis , Sarcoma/pathology
7.
Phys Med Biol ; 64(6): 065007, 2019 03 12.
Article in English | MEDLINE | ID: mdl-30708357

ABSTRACT

Advances in computed tomography (CT) hardware have propelled the development of novel CT contrast agents. In particular, the spectral capabilities of x-ray CT can facilitate simultaneous imaging of multiple contrast agents. This approach is particularly useful for functional imaging of solid tumors by simultaneous visualization of multiple targets or architectural features that govern cancer development and progression. Nanoparticles are a promising platform for contrast agent development. While several novel imaging moieties based on high atomic number elements are being explored, iodine (I) and gadolinium (Gd) are particularly attractive because of their existing approval for clinical use. In this work, we investigate the in vivo discrimination of I and Gd nanoparticle contrast agents using both dual energy micro-CT with energy integrating detectors (DE-EID) and photon counting detector (PCD)-based spectral micro-CT. Simulations and phantom experiments were performed using varying concentrations of I and Gd to determine the imaging performance with optimized acquisition parameters. Quantitative spectral micro-CT imaging using liposomal-iodine (Lip-I) and liposomal-Gd (Lip-Gd) nanoparticle contrast agents was performed in sarcoma bearing mice for anatomical and functional imaging of tumor vasculature. Iterative reconstruction provided high sensitivity to detect and discriminate relatively low I and Gd concentrations. According to the Rose criterion applied to the experimental results, the detectability limits for I and Gd were approximately 2.5 mg ml-1 for both DE-EID CT and PCD micro-CT, even if the radiation dose was approximately 3.8 times lower with PCD micro-CT. The material concentration maps confirmed expected biodistributions of contrast agents in the blood, liver, spleen and kidneys. The PCD provided lower background signal and better simultaneous visualization of tumor vasculature and intratumoral distribution patterns of nanoparticle contrast agent compared to DE-EID decompositions. Preclinical spectral CT systems such as this could be useful for functional characterization of solid tumors, simultaneous quantitative imaging of multiple targets and for identifying clinically-relevant applications that benefit from the use of spectral imaging. Additionally, it could aid in the development nanoparticles that show promise in the developing field of cancer theranostics (therapy and diagnostics) by measuring vascular tumor biomarkers such as fractional blood volume and the delivery of liposomal chemotherapeutics.


Subject(s)
Contrast Media , Gadolinium/metabolism , Iodine/metabolism , Nanoparticles/chemistry , Phantoms, Imaging , Sarcoma/pathology , X-Ray Microtomography/methods , Animals , Humans , Magnetic Resonance Imaging , Mice , Mice, Inbred C57BL , Neovascularization, Pathologic , Photons , Sarcoma/blood supply , Sarcoma/diagnostic imaging , Sarcoma/metabolism , Tomography Scanners, X-Ray Computed , X-Ray Microtomography/instrumentation
8.
Phys Med Biol ; 63(2): 025009, 2018 01 09.
Article in English | MEDLINE | ID: mdl-29148430

ABSTRACT

Micro-CT is widely used in preclinical studies, generating substantial interest in extending its capabilities in functional imaging applications such as blood perfusion and cardiac function. However, imaging cardiac structure and function in mice is challenging due to their small size and rapid heart rate. To overcome these challenges, we propose and compare improvements on two strategies for cardiac gating in dual-source, preclinical micro-CT: fast prospective gating (PG) and uncorrelated retrospective gating (RG). These sampling strategies combined with a sophisticated iterative image reconstruction algorithm provide faster acquisitions and high image quality in low-dose 4D (i.e. 3D + Time) cardiac micro-CT. Fast PG is performed under continuous subject rotation which results in interleaved projection angles between cardiac phases. Thus, fast PG provides a well-sampled temporal average image for use as a prior in iterative reconstruction. Uncorrelated RG incorporates random delays during sampling to prevent correlations between heart rate and sampling rate. We have performed both simulations and animal studies to validate these new sampling protocols. Sampling times for 1000 projections using fast PG and RG were 2 and 3 min, respectively, and the total dose was 170 mGy each. Reconstructions were performed using a 4D iterative reconstruction technique based on the split Bregman method. To examine undersampling robustness, subsets of 500 and 250 projections were also used for reconstruction. Both sampling strategies in conjunction with our iterative reconstruction method are capable of resolving cardiac phases and provide high image quality. In general, for equal numbers of projections, fast PG shows fewer errors than RG and is more robust to undersampling. Our results indicate that only 1000-projection based reconstruction with fast PG satisfies a 5% error criterion in left ventricular volume estimation. These methods promise low-dose imaging with a wide range of preclinical applications in cardiac imaging.


Subject(s)
Algorithms , Four-Dimensional Computed Tomography/methods , Heart/anatomy & histology , Heart/diagnostic imaging , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , X-Ray Microtomography/methods , Animals , Mice , Radiation Dosage
9.
Phys Med ; 30(6): 619-34, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24974176

ABSTRACT

Micron-scale computed tomography (micro-CT) is an essential tool for phenotyping and for elucidating diseases and their therapies. This work is focused on preclinical micro-CT imaging, reviewing relevant principles, technologies, and applications. Commonly, micro-CT provides high-resolution anatomic information, either on its own or in conjunction with lower-resolution functional imaging modalities such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT). More recently, however, advanced applications of micro-CT produce functional information by translating clinical applications to model systems (e.g., measuring cardiac functional metrics) and by pioneering new ones (e.g. measuring tumor vascular permeability with nanoparticle contrast agents). The primary limitations of micro-CT imaging are the associated radiation dose and relatively poor soft tissue contrast. We review several image reconstruction strategies based on iterative, statistical, and gradient sparsity regularization, demonstrating that high image quality is achievable with low radiation dose given ever more powerful computational resources. We also review two contrast mechanisms under intense development. The first is spectral contrast for quantitative material discrimination in combination with passive or actively targeted nanoparticle contrast agents. The second is phase contrast which measures refraction in biological tissues for improved contrast and potentially reduced radiation dose relative to standard absorption imaging. These technological advancements promise to develop micro-CT into a commonplace, functional and even molecular imaging modality.


Subject(s)
X-Ray Microtomography/methods , Animals , Contrast Media , Humans , Image Processing, Computer-Assisted , Radiation Dosage
10.
Proc SPIE Int Soc Opt Eng ; 8313: 83130T, 2012.
Article in English | MEDLINE | ID: mdl-23227300

ABSTRACT

X-ray Luminescence CT (XLCT) is a hybrid imaging modality combining x-ray and optical imaging in which x-ray luminescent nanophosphors (NPs) are used as emissive imaging probes. NPs are easily excited using common CT energy x-ray beams, and the NP luminescence is efficiently collected using sensitive light based detection systems. XLCT can be recognized as a close analog to fluorescence diffuse optical tomography (FDOT). However, XLCT has remarkable advantages over FDOT due to the substantial excitation penetration depths provided by x-rays relative to laser light sources, long term photo-stability of NPs, and the ability to tune NP emission within the NIR spectral window. Since XCLT uses an x-ray pencil beam excitation, the emitted light can be measured and back-projected along the x-ray path during reconstruction, where the size of the X-ray pencil beam determines the resolution for XLCT. In addition, no background signal competes with NP luminescence (i.e., no auto fluorescence) in XLCT. Currently, no small animal XLCT system has been proposed or tested. This paper investigates an XLCT system built and integrated with a dual source micro-CT system. Two novel sampling paradigms that result in more efficient scanning are proposed and tested via simulations. Our preliminary experimental results in phantoms indicate that a basic CT-like reconstruction is able to recover a map of the NP locations and differences in NP concentrations. With the proposed dual source system and faster scanning approaches, XLCT has the potential to revolutionize molecular imaging in preclinical studies.

11.
Am J Physiol Lung Cell Mol Physiol ; 302(10): L1088-97, 2012 May 15.
Article in English | MEDLINE | ID: mdl-22427526

ABSTRACT

The purpose of this work is to investigate the use of dual-energy micro-computed tomography (CT) for the estimation of vascular, tissue, and air fractions in rodent lungs using a postreconstruction three material decomposition method. Using simulations, we have estimated the accuracy limits of the decomposition for realistic micro-CT noise levels. Next, we performed experiments involving ex vivo lung imaging in which intact rat lungs were carefully removed from the thorax, injected with an iodine-based contrast agent, and then inflated with different volumes of air (n = 2). Finally, we performed in vivo imaging studies in C57BL/6 mice (n = 5) using fast prospective respiratory gating in end inspiration and end expiration for three different levels of positive end expiratory pressure (PEEP). Before imaging, mice were injected with a liposomal blood pool contrast agent. The three-dimensional air, tissue, and blood fraction maps were computed and analyzed. The results indicate that separation and volume estimation of the three material components of the lungs are possible. The mean accuracy values for air, blood, and tissue were 93, 93, and 90%, respectively. The absolute accuracy in determining all fraction materials was 91.6%. The coefficient of variation was small (2.5%) indicating good repeatability. The minimum difference that we could detect in material fractions was 15%. As expected, an increase in PEEP levels for the living mouse resulted in statistically significant increases in air fractions at end expiration but no significant changes at end inspiration. Our method has applicability in preclinical pulmonary studies where changes in lung structure and gas volume as a result of lung injury, environmental exposures, or drug bioactivity would have important physiological implications.


Subject(s)
Lung/diagnostic imaging , Respiratory-Gated Imaging Techniques/methods , Tomography, X-Ray Computed/methods , Animals , Computer Simulation , Contrast Media/chemistry , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , In Vitro Techniques , Lung/physiology , Mice , Positive-Pressure Respiration , Rats , Rats, Sprague-Dawley , Reproducibility of Results , Respiration , Respiratory-Gated Imaging Techniques/instrumentation , Sensitivity and Specificity , Tidal Volume/physiology , Tomography, X-Ray Computed/instrumentation
12.
Proc SPIE Int Soc Opt Eng ; 83172012 Apr 03.
Article in English | MEDLINE | ID: mdl-24027623

ABSTRACT

Dual energy CT imaging is expected to play a major role in the diagnostic arena as it provides material decomposition on an elemental basis. The purpose of this work is to investigate the use of dual energy micro-CT for the estimation of vascular, tissue, and air fractions in rodent lungs using a post-reconstruction three-material decomposition method. We have tested our method using both simulations and experimental work. Using simulations, we have estimated the accuracy limits of the decomposition for realistic micro-CT noise levels. Next, we performed experiments involving ex vivo lung imaging in which intact lungs were carefully removed from the thorax, were injected with an iodine-based contrast agent and inflated with air at different volume levels. Finally, we performed in vivo imaging studies in (n=5) C57BL/6 mice using fast prospective respiratory gating in end-inspiration and end-expiration for three different levels of positive end-expiratory pressure (PEEP). Prior to imaging, mice were injected with a liposomal blood pool contrast agent. The mean accuracy values were for Air (95.5%), Blood (96%), and Tissue (92.4%). The absolute accuracy in determining all fraction materials was 94.6%. The minimum difference that we could detect in material fractions was 15%. As expected, an increase in PEEP levels for the living mouse resulted in statistically significant increases in air fractions at end-expiration, but no significant changes in end-inspiration. Our method has applicability in preclinical pulmonary studies where various physiological changes can occur as a result of genetic changes, lung disease, or drug effects.

13.
Proc SPIE Int Soc Opt Eng ; 83142012 Feb 23.
Article in English | MEDLINE | ID: mdl-24386540

ABSTRACT

Bilateral filtration has proven an effective tool for denoising CT data. The classic filter utilizes Gaussian domain and range weighting functions in 2D. More recently, other distributions have yielded more accurate results in specific applications, and the bilateral filtration framework has been extended to higher dimensions. In this study, brute-force optimization is employed to evaluate the use of several alternative distributions for both domain and range weighting: Andrew's Sine Wave, El Fallah Ford, Gaussian, Flat, Lorentzian, Huber's Minimax, Tukey's Bi-weight, and Cosine. Two variations on the classic bilateral filter which use median filtration to reduce bias in range weights are also investigated: median-centric and hybrid bilateral filtration. Using the 4D MOBY mouse phantom reconstructed with noise (stdev. ~ 65 HU), hybrid bilateral filtration, a combination of the classic and median-centric filters, with Flat domain and range weighting is shown to provide optimal denoising results (PSNRs: 31.69, classic; 31.58 median-centric; 32.25, hybrid). To validate these phantom studies, the optimal filters are also applied to in vivo, 4D cardiac micro-CT data acquired in the mouse. In a constant region of the left ventricle, hybrid bilateral filtration with Flat domain and range weighting is shown to provide optimal smoothing (stdev: original, 72.2 HU; classic, 20.3 HU; median-centric, 24.1 HU; hybrid, 15.9 HU). While the optimal results were obtained using 4D filtration, the 3D hybrid filter is ultimately recommended for denoising 4D cardiac micro-CT data because it is more computationally tractable and less prone to artifacts (MOBY PSNR: 32.05; left ventricle stdev: 20.5 HU).

14.
Proc SPIE Int Soc Opt Eng ; 7622: 76223G.1-76223G.9, 2010 Feb 15.
Article in English | MEDLINE | ID: mdl-21243034

ABSTRACT

Gating in small animal imaging can compensate for artifacts due to physiological motion. This paper presents a strategy for sampling and image reconstruction in the rodent lung using micro-CT. The approach involves rapid sampling of free-breathing mice without any additional hardware to detect respiratory motion. The projection images are analyzed post-acquisition to derive a respiratory signal, which is used to provide weighting factors for each projection that favor a selected phase of the respiration (e.g. end-inspiration or end-expiration) for the reconstruction. Since the sampling cycle and the respiratory cycle are uncorrelated, the sets of projections corresponding to any of the selected respiratory phases do not have a regular angular distribution. This drastically affects the image quality of reconstructions based on simple filtered backprojection. To address this problem, we use an iterative reconstruction algorithm that combines the Simultaneous Algebraic Reconstruction Technique with Total Variation minimization (SART-TV). At each SART-TV iteration, backprojection is performed with a set of weighting factors that favor the desired respiratory phase. To reduce reconstruction time, the algorithm is implemented on a graphics processing unit. The performance of the proposed approach was investigated in simulations and in vivo scans of mice with primary lung cancers imaged with our in-house developed dual tube/detector micro-CT system. We note that if the ECG signal is acquired during sampling, the same approach could be used for phase-selective cardiac imaging.

15.
Phys Med Biol ; 53(19): R319-50, 2008 Oct 07.
Article in English | MEDLINE | ID: mdl-18758005

ABSTRACT

Small-animal imaging has a critical role in phenotyping, drug discovery and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review in vivo x-ray based small-animal imaging, with a focus on in vivo micro-computed tomography (micro-CT) and digital subtraction angiography (DSA). We present the principles, technologies, image quality parameters and types of applications. We show that both methods can be used not only to provide morphological, but also functional information, such as cardiac function estimation or perfusion. Compared to other modalities, x-ray based imaging is usually regarded as being able to provide higher throughput at lower cost and adequate resolution. The limitations are usually associated with the relatively poor contrast mechanisms and potential radiation damage due to ionizing radiation, although the use of contrast agents and careful design of studies can address these limitations. We hope that the information will effectively address how x-ray based imaging can be exploited for successful in vivo preclinical imaging.


Subject(s)
Angiography, Digital Subtraction/methods , X-Ray Microtomography/methods , Angiography, Digital Subtraction/instrumentation , Animals , Humans
16.
Proc SPIE Int Soc Opt Eng ; 6913: 691342, 2008 Apr 18.
Article in English | MEDLINE | ID: mdl-22049304

ABSTRACT

Micro-CT is a non-invasive imaging modality usually used to assess morphology in small animals. In our previous work, we have demonstrated that functional micro-CT imaging is also possible. This paper describes a dual micro-CT system with two fixed x-ray/detectors developed to address such challenging tasks as cardiac or perfusion studies in small animals. A two-tube/detector system ensures simultaneous acquisition of two projections, thus reducing scanning time and the number of contrast injections in perfusion studies by a factor of two. The system is integrated with software developed in-house for cardio-respiratory monitoring and gating. The sampling geometry was optimized for 88 microns in such a way that the geometric blur of the focal spot matches the Nyquist sample at the detector. A geometric calibration procedure allows one to combine projection data from the two chains into a single reconstructed volume. Image quality was measured in terms of spatial resolution, uniformity, noise, and linearity. The modulation transfer function (MTF) at 10% is 3.4 lp/mm for single detector reconstructions and 2.3 lp/mm for dual tube/detector reconstructions. We attribute this loss in spatial resolution to the compounding of slight errors in the separate single chain calibrations. The dual micro-CT system is currently used in studies for morphological and functional imaging of both rats and mice.