1.
BMC Ophthalmol ; 22(1): 498, 2022 Dec 19.
Article in English | MEDLINE | ID: mdl-36536321

ABSTRACT

BACKGROUND: Refraction is one of the key components of a comprehensive eye examination. Auto refractometers that are reliable and affordable can be beneficial, especially in a low-resource community setting. The study aimed to validate the accuracy of a novel wave-front aberrometry-based auto refractometer, Instaref R20 against the open-field system and subjective refraction in an adult population. METHODS: All the participants underwent a comprehensive eye examination including objective refraction, subjective acceptance, anterior and posterior segment evaluation. Refraction was performed without cycloplegia using WAM5500 open-field auto refractometer (OFAR) and Instaref R20, the study device. Agreement between both methods was evaluated using Bland-Altman analysis. The repeatability of the device based on three measurements in a subgroup of 40 adults was assessed. RESULTS: The refractive error was measured in 132 participants (mean age,30.53 ± 9.36 years, 58.3% female). The paired mean difference of the refraction values of the study device against OFAR was - 0.13D for M, - 0.0002D (J0) and - 0.13D (J45) and against subjective refraction (SR) was - 0.09D (M), 0.06 (J0) and 0.03D (J45). The device agreed within +/- 0.50D of OFAR in 78% of eyes for M, 79% for J0 and 78% for J45. The device agreed within +/- 0.5D of SR values for M (84%), J0 (86%) and J45 (89%). CONCLUSION: This study found a good agreement between the measurements obtained with the portable autorefractor against open-field refractometer and SR values. It has a potential application in population-based community vision screening programs for refractive error correction without the need for highly trained personnel.


Subject(s)
Refractive Errors , Vision Screening , Humans , Adult , Female , Young Adult , Male , Prospective Studies , Aberrometry , Reproducibility of Results , Refraction, Ocular , Refractive Errors/diagnosis , Vision Tests , Vision Screening/methods
2.
Clin Ophthalmol ; 16: 4281-4291, 2022.
Article in English | MEDLINE | ID: mdl-36578668

ABSTRACT

Purpose: InstaRef R20 is a handheld, affordable auto refractometer based on Shack Hartmann aberrometry technology. The study's objective was to compare InstaRef R20's performance for identifying refractive error in a paediatric population to that of standard subjective and objective refraction under both pre- and post-cycloplegic conditions. Methods: Refraction was performed using 1) standard clinical procedure consisting of retinoscopy followed by subjective refraction (SR) under pre- and post-cycloplegic conditions and 2) InstaRef R20. Agreement between both methods was evaluated using Bland-Altman analysis. The repeatability of the device based on three measurements in a subgroup of 20 children was assessed. Results: The refractive error was measured in 132 children (mean age 12.31 ± 3 years). The spherical equivalent (M) and cylindrical components (J0 and J45) of the device had clinically acceptable differences (within ±0.50D) and acceptable agreement compared to standard pre- and post-cycloplegic manual retinoscopy and subjective refraction (SR). The device agreed within ± 0.50D of retinoscopy in 67% of eyes for M, 78% for J0 and 80% for J45 and within ± 0.50D of SR in 70% for M and 77% for cylindrical components. Conclusion: InstaRef R20 has an acceptable agreement compared to standard retinoscopy in paediatric population. The measurements from this device can be used as a starting point for subjective acceptance. The device being simple to use, portable, reliable and affordable has the potential for large-scale community-based refractive error detection.

3.
Transl Vis Sci Technol ; 10(8): 29, 2021 07 01.
Article in English | MEDLINE | ID: mdl-34319384

ABSTRACT

Purpose: Telemedicine-enabled, portable digital slit lamps can help to decentralize screening to close-to-patient contexts. We report a novel design for a portable, digital slit lamp using a smartphone. It works on an advanced optical design and has the capability of instantaneous, objective photodocumentation to capture anterior segment images and is telemedicine-enabled. Methods: The device is constructed keeping its usability and the importance of design ergonomics for nonspecialized field personnel in mind. The optical design is described, and the resolution and magnification are compared with traditional desktop-based slit lamps. A Health Insurance Portability and Accountability Act (HIPAA)-compliant, patient management software is integrated to synchronize the captured images with a secure cloud server along with a sharpness algorithm to extract the best focused frames of the cornea, iris, and lens, from videos. We demonstrate its photodocumentation ability and teleophthalmology feasibility by capturing images in a pilot study from nine subjects. Results: Images were obtained in various illumination, magnification, and filter settings. Synchronous and asynchronous teleophthalmology consults were conducted. The performance of the device was shown to be limited by the smartphone sensor resolution and not the optical design, because the Air Force target resolution was found to be the same on smartphone-mounted traditional slit lamps despite a lower magnification. Conclusions: The novel, portable, digital slit lamp with advanced optical design using smartphones has the ability to screen for anterior segment pathologies using telemedicine. Translational Relevance: A portable, telemedicine-friendly, ergonomically designed, slit lamp used by nonspecialist personnel allows for both synchronous and asynchronous modes of consultation at remote locations, facilitating mass screening programs.


Subject(s)
Ophthalmology , Telemedicine , Humans , Mass Screening , Photography , Pilot Projects , Slit Lamp , Smartphone , United States