Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Appl Mater Interfaces ; 11(50): 46808-46817, 2019 Dec 18.
Article in English | MEDLINE | ID: mdl-31738042

ABSTRACT

Increasing the open-circuit voltage (Voc) is one of the key strategies for further improvement of the efficiency of perovskite solar cells. It requires fundamental understanding of the complex optoelectronic processes related to charge carrier generation, transport, extraction, and their loss mechanisms inside a device upon illumination. Herein, we report the important origin of Voc losses in methylammonium lead iodide perovskite (MAPI)-based solar cells, which results from undesirable positive charge (hole) accumulation at the interface between the perovskite photoactive layer and the poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) hole-transport layer. We show strong correlation between the thickness-dependent surface photovoltage and device performance, unraveling that the interfacial charge accumulation leads to charge carrier recombination and results in a large decrease in Voc for the PEDOT:PSS/MAPI inverted devices (180 mV reduction in 50 nm thick device compared to 230 nm thick one). In contrast, accumulated positive charges at the TiO2/MAPI interface modify interfacial energy band bending, which leads to an increase in Voc for the TiO2/MAPI conventional devices (70 mV increase in 50 nm thick device compared to 230 nm thick one). Our results provide an important guideline for better control of interfaces in perovskite solar cells to improve device performance further.

2.
Phys Rev E Stat Nonlin Soft Matter Phys ; 85(6 Pt 1): 061901, 2012 Jun.
Article in English | MEDLINE | ID: mdl-23005121

ABSTRACT

The Kelvin probe measures surface electrical potential without making physical contact with the specimen. It relies on capacitive coupling between an oscillating metal tip that is normal to a specimen's surface. Kelvin probes have been increasingly used to study surface and electrical properties of metals and semiconductors and are capable of detecting material surface potentials with submillivolt resolution at a micrometer spatial scale. Its capability for measuring electrical potential without being confounded by electrode-specimen contact makes extending its use towards biological materials particularly appealing. However, the theoretical basis for applying the Kelvin probe to dielectric or partially conductive materials such as biological tissue has not been evaluated and remains unclear. This study develops the theoretical basis underlying Kelvin probe measurements in five theoretical materials: highly conductive, conductive dielectric with rapid charge relaxation, conductive dielectric with slow charge relaxation, perfect dielectric, and tissue with a bulk serial resistance. These theoretically derived equations are then computationally analyzed using parameters from both theoretical specimens and actual biomaterials-including wet skin, dry skin, cerebrospinal fluid, and tendon. Based on these analyses, a Kelvin probe performs in two distinct ways depending on the charge relaxation rates of the sample: The specimen is treated either as a perfect dielectric or as highly conductive material. Because of their rapid relaxation rate and increased permittivity biomaterials behave similarly to highly conductive materials, such as metal, when evaluated by the Kelvin probe. These results indicate that the Kelvin probe can be readily applied to studying the surface potential of biological tissue.


Subject(s)
Electrodiagnosis/methods , Microscopy, Scanning Probe/methods , Models, Biological , Animals , Computer Simulation , Electromagnetic Fields , Humans
3.
Article in English | MEDLINE | ID: mdl-23320033

ABSTRACT

Objective. Acupuncture points are reportedly distinguishable by their electrical properties. However, confounders arising from skin-to-electrode contact used in traditional electrodermal methods have contributed to controversies over this claim. The Scanning Kelvin Probe is a state-of-the-art device that measures electrical potential without actually touching the skin and is thus capable of overcoming these confounding effects. In this study, we evaluated the electrical potential profiles of acupoints LI-4 and PC-6 and their adjacent controls. We hypothesize that acupuncture point sites are associated with increased variability in potential compared to adjacent control sites. Methods. Twelve healthy individuals were recruited for this study. Acupuncture points LI-4 and PC-6 and their adjacent controls were assessed. A 2 mm probe tip was placed over the predetermined skin site and adjusted to a tip-to-sample distance of 1.0 mm under tip oscillation settings of 62.4 Hz frequency. A 6 × 6 surface potential scan spanning a 1.0 cm × 1.0 cm area was obtained. Results. At both the PC-6 and LI-4 sites, no significant differences in mean potential were observed compared to their respective controls (Wilcoxon rank-sum test, P = 0.73 and 0.79, resp.). However, the LI-4 site was associated with significant increase in variability compared to its control as denoted by standard deviation and range (P = 0.002 and 0.0005, resp.). At the PC-6 site, no statistical differences in variability were observed. Conclusion. Acupuncture points may be associated with increased variability in electrical potential.

4.
Nano Lett ; 12(1): 39-44, 2012 Jan 11.
Article in English | MEDLINE | ID: mdl-22149211

ABSTRACT

Although ambient processing is the key to low-cost organic solar cell production, high-vacuum thermal evaporation of LiF is often a limiting step, motivating the exploration of solution processing of LiF as an alternative electrode interlayer. Submonolayer films are realized with the assistance of polymeric micelle reactors that enable LiF particle deposition with controlled nanoscale surface coverage. Scanning Kelvin probe reveals a work function tunable with nanoparticle coverage with higher values than that of bare indium tin oxide (ITO).


Subject(s)
Crystallization/methods , Electrodes , Fluorides/chemistry , Lithium Compounds/chemistry , Nanostructures/chemistry , Nanostructures/ultrastructure , Equipment Design , Equipment Failure Analysis , Macromolecular Substances/chemistry , Materials Testing , Molecular Conformation , Particle Size , Solutions , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...