1.
Eur Heart J Case Rep ; 8(5): ytae203, 2024 May.
Article in English | MEDLINE | ID: mdl-38721252

ABSTRACT

Background: Partial anomalous pulmonary venous return (PAPVR) can be surgically corrected using a pericardial baffle. This baffle can become obstructed post-surgery, leading to pulmonary hypertension and right heart dysfunction if not detected and corrected. Case summary: We describe three patients with occluded PAPVR baffles who underwent drug-coated balloon angioplasty and stenting of the obstructed baffle. In each case, baffle obstruction was detected post-operatively on surveillance cross-sectional imaging, and an invasively measured pulmonary capillary wedge-to-left atrium gradient was noted to be elevated. Post-intervention, each patient had an improvement in baffle flow by angiography as well as lung perfusion as assessed by nuclear medicine scintigraphy. Discussion: Given the subtle symptomatology of obstructed PAPVR pericardial baffle repairs, surveillance imaging is necessary to detect occluded baffles and intervene before downstream right heart disease and pulmonary hypertension develops. Given the high rates of re-stenosis in pulmonary vein stenting, pre-treatment of occluded PAPVR baffles with drug-coated balloons may help reduce re-intervention rates.

2.
Article in English | MEDLINE | ID: mdl-38641438

ABSTRACT

BACKGROUND: Candidates for transcatheter aortic valve replacement (TAVR) occasionally have a "borderline-size" aortic annulus between 2 transcatheter heart valve sizes, based on the manufacturer's sizing chart. Data on TAVR outcomes in such patients are limited. METHODS: We retrospectively reviewed 1816 patients who underwent transfemoral-TAVR with balloon-expandable valve (BEV) at our institution between 2016 and 2020. We divided patients into borderline and non-borderline groups based on computed tomography-derived annular measurements and compared outcomes. Furthermore, we analyzed procedural characteristics and compared outcomes between the smaller- and larger-valve strategies in patients with borderline-size annulus. RESULTS: During a median follow-up of 23.3 months, there was no significant difference between the borderline (n = 310, 17.0 %) and non-borderline (n = 1506) groups in mortality (17.3 % vs. 19.5 %; hazard ratio [HR] = 0.86 [95% CI = 0.62-1.20], p = 0.39), major adverse cardiac/cerebrovascular events (MACCE: death/myocardial infarction/stroke, 21.2 % vs. 21.5 %; HR = 0.97 [0.71-1.32], p = 0.85), paravalvular leak (PVL: mild 21.8 % vs. 20.6 %, p = 0.81; moderate 0 % vs. 1.2 %; p = 0.37), or mean gradient (12.9 ± 5.8 vs. 12.6 ± 5.2 mmHg, p = 0.69) at 1 year. There was no significant difference between the larger-(n = 113) and smaller-valve(n = 197) subgroups in mortality (23.7 % vs. 15.2 %; HR = 1.57 [0.89-2.77], p = 0.12), MACCE (28.1 % vs. 18.4 %; HR = 1.52 [0.91-2.54], p = 0.11), mild PVL (13.3 % vs. 25.9 %; p = 0.12), or mean gradient (12.3 ± 4.5 vs. 13.6 ± 5.3 mmHg, p = 0.16); however, the rate of permanent pacemaker implantation (PPI) was higher in the larger-valve subgroup (15.9 % vs. 2.6 %, p < 0.001). CONCLUSION: Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system.

3.
JACC Case Rep ; 29(4): 102199, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38379657

ABSTRACT

Transcatheter aortic valve replacement is not widely used in patients with congenital heart disease. We describe our single-center experience of transcatheter aortic valve replacement in congenital heart disease, demonstrating short-term feasibility and safety, role in lifetime management of congenital aortic valve disease, and use as a bridge to recovery, future surgery, or transplantation.

4.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Article in English | MEDLINE | ID: mdl-37438029

ABSTRACT

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Catheters
5.
Am J Cardiol ; 192: 88-97, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36758269

ABSTRACT

Hypoattenuated leaflet thickening (HALT) has been recognized as one of the complications after transcatheter aortic valve implantation and may promote structural valve degeneration and increase the risk of cerebrovascular events. The 2 main types of available transcatheter heart valves (THVs), the balloon-expandable (BE) and the self-expanding (SE), are interchangeably used in clinical practice despite substantial design differences. There is unclear evidence on whether these 2 different THV models are achieving similar or different rates of subclinical leaflet thrombosis/HALT. A systematic search of electronic databases was conducted to identify studies that reported the incidence of HALT between SE THVs and BE THVs. The Mantel-Haenszel method was used to calculate the 95% confidence interval and pooled risk ratio with a random-effects model. A total of 126 records were identified, of which 22 studies comprising 14,401 patients were included in our final analysis. Among 5,951 patients receiving SE THVs, 194 (3.2%) developed HALT, compared with 8,450 patients receiving BE THVs, of whom 484 (5.7%) developed HALT. There was a statistically significant decrease in the risk of developing HALT in patients receiving SE THVs compared with those receiving BE THVs (risk ratio 0.75, 95% confidence interval 0.59 to 0.95, I2 32%, p = 0.02). In conclusion, could potentially reduce the risk of HALT/subclinical leaflet thrombosis.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Thrombosis/epidemiology , Prosthesis Design , Treatment Outcome
6.
JACC Case Rep ; 1(5): 781-786, 2019 Dec 18.
Article in English | MEDLINE | ID: mdl-34316931

ABSTRACT

This case illustrates a novel percutaneous treatment of a highly vascular thoracic tumor impinging on the left atrium and right pulmonary artery by delivery of coils and alcohol ablation via a circumflex coronary artery feeder branch. (Level of Difficulty: Advanced.).