Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Sleep ; 45(5)2022 05 12.
Article in English | MEDLINE | ID: mdl-35554594

ABSTRACT

STUDY OBJECTIVES: The diagnosis of narcolepsy type 1 (NT1) is based upon the presence of cataplexy and/or a cerebrospinal fluid (CSF) hypocretin-1/orexin-A level ≤ 110 pg/mL. We determined the clinical and diagnostic characteristics of patients with intermediate hypocretin-1 levels (111-200 pg/mL) and the diagnostic value of cataplexy characteristics in individuals with central disorders of hypersomnolence. METHODS: Retrospective cross-sectional study of 355 people with known CSF hypocretin-1 levels who visited specialized Sleep-Wake Centers in the Netherlands. For n = 271, we had full data on cataplexy type ("typical" or "atypical" cataplexy). RESULTS: Compared to those with normal hypocretin-1 levels (>200 pg/mL), a higher percentage of individuals with intermediate hypocretin-1 levels had typical cataplexy (75% or 12/16 vs 9% or 8/88, p < .05), and/or met the diagnostic polysomnographic (PSG) and Multiple Sleep Latency Test (MSLT) criteria for narcolepsy (50 vs 6%, p < .001). Of those with typical cataplexy, 88% had low, 7% intermediate, and 5% normal hypocretin-1 levels (p < .001). Atypical cataplexy was also associated with hypocretin deficiency but to a lesser extent. A hypocretin-1 cutoff of 150 pg/mL best predicted the presence of typical cataplexy and/or positive PSG and MSLT findings. CONCLUSION: Individuals with intermediate hypocretin-1 levels or typical cataplexy more often have outcomes fitting the PSG and MSLT criteria for narcolepsy than those with normal levels or atypical cataplexy. In addition, typical cataplexy has a much stronger association with hypocretin-1 deficiency than atypical cataplexy. We suggest increasing the NT1 diagnostic hypocretin-1 cutoff and adding the presence of clearly defined typical cataplexy to the diagnostic criteria of NT1. Clinical trial information: This study is not registered in a clinical trial register, as it has a retrospective database design.


Subject(s)
Cataplexy , Narcolepsy , Neuropeptides , Cataplexy/cerebrospinal fluid , Cataplexy/diagnosis , Cross-Sectional Studies , Humans , Intracellular Signaling Peptides and Proteins , Narcolepsy/cerebrospinal fluid , Narcolepsy/diagnosis , Orexins/cerebrospinal fluid , Retrospective Studies
2.
Sleep ; 45(7)2022 07 11.
Article in English | MEDLINE | ID: mdl-35512685

ABSTRACT

STUDY OBJECTIVES: The most sensitive and specific investigative method for the diagnosis of narcolepsy type 1 (NT1) is the determination of hypocretin-1 (orexin-A) deficiency (≤110 pg/mL) in cerebrospinal fluid using a radioimmunoassay (RIA). We aimed to assess the reliability of the Phoenix Pharmaceuticals hypocretin-1 RIA, by determining the lower limit of quantification (LLOQ), the variability around the cutoff of 110 pg/mL, and the inter- and intra-assay variability. METHODS: Raw data of 80 consecutive hypocretin-1 RIAs were used to estimate the intra- and inter-assay coefficient of variation (CV). The LLOQ was established and defined as the lowest converted concentration with a CV <25%; the conversion is performed using a harmonization sample which is internationally used to minimize variation between RIAs. RESULTS: The mean intra-assay CV was 4.7%, while the unconverted inter-assay CV was 28.3% (18.5% excluding 2 outliers) and 7.5% when converted to international values. The LLOQ was determined as 27.9 pg/mL. The intra-assay CV of RIAs with lower specific radioactive activity showed a median of 5.6% (n = 41, range 1.6%-17.0%), which was significantly higher than in RIAs with higher specific activity (n = 36; median 3.2%, range 0.4%-11.6%, p = .013). The CV around the 110 pg/mL cutoff was <7%. CONCLUSIONS: Hypocretin-1 RIAs should always be harmonized using standard reference material. The specific activity of an RIA has a significant impact on its reliability, because of the decay of 125I radioactivity. Values around the hypocretin-1 cut-off can reliably be measured. Hypocretin-1 concentrations below 28 pg/mL should be reported as "undetectable" when measured with the Phoenix Pharmaceuticals RIA. CLINICAL TRIAL INFORMATION: This study is not registered in a clinical trial register, as it has a retrospective database design.


Subject(s)
Iodine Radioisotopes , Narcolepsy , Humans , Narcolepsy/cerebrospinal fluid , Narcolepsy/diagnosis , Orexins/cerebrospinal fluid , Pharmaceutical Preparations , Radioimmunoassay/methods , Reproducibility of Results , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL