Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
2.
J Cardiovasc Comput Tomogr ; 8(5): 384-90, 2014.
Article in English | MEDLINE | ID: mdl-25301044

ABSTRACT

BACKGROUND: Pacemaker or implantable cardioverter-defibrillator lead extraction may be required because of infection, malfunction, or breakage. The preprocedural identification of lead tip position may help ensure safe performance of the procedure. OBJECTIVE: To analyze the ability of chest radiography and CT imaging to characterize lead tip position and identify perforation in a population of patients who underwent lead extraction. METHODS: Among patients who underwent lead extraction between November 2008 and April 2011, a nonrandom subset of 50 patients with 116 leads was selected for retrospective analysis. All patients had undergone chest radiography and thin-section electrocardiography-gated noncontrast cardiac CT. Two radiologists independently evaluated the imaging studies, using oblique multiplanar image reconstruction techniques for the CT examinations. Beam hardening artifacts were graded (0-3). Likelihood of perforation on each imaging study was graded on a 5-point scale. RESULTS: Among 116 leads, 17 were identified as perforated on CT, 12 leads were equivocal, and 87 were not perforated. Interobserver agreement for CT perforation vs nonperforation was good (κ = 0.71); weighted kappa for the entire 5-point scale was moderate (κ = 0.54). Beam hardening artifacts were common, with a mean value of 2.1. The 2 observers identified perforation on chest radiography with an average sensitivity of 15% compared with CT. The 2 observers did not agree on any cases of chest radiographic perforation (κ = -0.1). CONCLUSION: Electrocardiography-gated noncontrast cardiac CT imaging with oblique multiplanar analysis can identify potential lead perforation with a moderate-to-good level of interobserver agreement. Chest radiography demonstrates poor sensitivity and interobserver agreement compared with CT.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Electrodes, Implanted/adverse effects , Pacemaker, Artificial/adverse effects , Radiography, Thoracic/methods , Thoracic Injuries/diagnostic imaging , Tomography, X-Ray Computed/methods , Wounds, Penetrating/diagnostic imaging , Aged , Contrast Media , Equipment Failure Analysis/methods , Equipment Failure Analysis/standards , Female , Humans , Male , Observer Variation , Reproducibility of Results , Sensitivity and Specificity , Thoracic Injuries/etiology , Wounds, Penetrating/etiology
SELECTION OF CITATIONS
SEARCH DETAIL