Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Int J Cardiol Heart Vasc ; 43: 101110, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36051245

ABSTRACT

Background: Limited data is available on the comparison of outcomes of transradial (TR) and transfemoral (TF) access for percutaneous coronary intervention (PCI) in patients with end-stage stage renal disease (ESRD). Methods: Online databases were queried to compare cardiovascular outcomes among TR. and TF in ESRD patients. The outcomes assessed included differences in mortality, cerebrovascular accidents (CVA), periprocedural myocardial infarction (MI), bleeding, transfusion, and periprocedural cardiogenic shock (CS). Unadjusted odds ratios (OR) were calculated using a random-effect effect model. Results: A total of 6 studies including 7,607 patients (TR-PCI = 1,288; TF-PCI = 6,319) were included. The overall mean age was 67.7 years, while the mean age for TR-PCI and TF-PCI was 69.7 years and 67.9 years, respectively. TR-PCI was associated with lower incidence of mortality (OR 0.46 95 % CI 0.30-0.70, p < 0.05, I2 0.00 %), bleeding (OR 0.45 95 % CI 0.29, 0.68, p < 0.05, I2 3.48 %), and transfusion requirement (OR 0.52 95 % CI 0.40, 0.67, p < 0.05, I2 0.00 %) (Fig. 1). There were no differences among TR-PCI and TF-PCI for periprocedural MI, periprocedural CS, and CVA outcomes. Conclusion: TR access was associated with lower mortality, bleeding, and transfusion requirement as compared to TF access in patients with ESRD undergoing PCI.

2.
Expert Rev Cardiovasc Ther ; 20(2): 151-160, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35172121

ABSTRACT

BACKGROUND: Inaccurate sizing of left atrial appendage (LAA) occlusion devices is associated with increased stroke risk. We compared the LAA size to implant the Watchman device assessed by computed tomography (CT) to transesophageal echocardiography (TEE). METHODS: Databases were searched to identify studies comparing LAA anatomical measurements and procedural outcomes across imaging modalities for the Watchman device implantation. RESULTS: Seven studies were included in the analysis (242 patients on TEE, and 232 on CT). The LAA orifice was larger when sized with CT compared to TEE (CT mean vs TEE SMD 0.30 mm, 95%CI 0.09-0.51 mm, P < 0.01; and CT max vs TEE SMD 0.69 mm, 95%CI 0.51-0.87 mm, P < 0.001). Additionally, CT, including CT-based 3-dimensional models, had higher odds of predicting correct device size compared to TEE (OR 1.64; 95%CI 1.05-2.56; P = 0.03). CT resulted in a lower fluoroscopy time vs TEE (SMD -0.78 min, 95% CI -1.39 to -0.18, P = 0.012). No significant differences were found in device clinical outcomes. CONCLUSION: Compared to TEE, CT resulted in larger LAA orifice measurements, improved odds of predicting correct device size, and reduced fluoroscopy time in patients undergoing LAA occlusion with the Watchman device. There were no significant differences in other procedural outcomes.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Cardiac Catheterization , Echocardiography, Transesophageal/methods , Humans , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL