Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 30(21): 37536-37553, 2022 Oct 10.
Article in English | MEDLINE | ID: mdl-36258341

ABSTRACT

Subaquatic indirect Laser-Induced Plasma-Assisted Ablation (SLIPAA) is proposed as a laser-based technique for glass processing. In this configuration, a water layer is added between a metallic target and a soda-lime glass substrate, so the processing of the glass is due to a combination of the ablation mechanism, the shock waves, and the cavitation bubbles. Thus, this method makes it possible to produce higher depth structures than those performed up to now by other standard laser techniques based on ablation, achieving structures in glass with rectangular cross-sectional profiles. Channels of 1 mm width are fabricated, reaching an average maximal depth value of almost 1400 µm at 30 passes of the laser beam while keeping the focal position fixed. Furthermore, the difference between processing the material with and without the addition of the water layer is presented. The influence of the processing parameters on the shape and quality of the fabricated structures is studied by optical and confocal microscopy, microcomputed tomography, and scanning electron microscopy. Compositional analysis of the glass is performed by energy dispersive X-ray technique to assess the transference of material from the metallic target to the fabricated channels. Deeper and more complex structures are obtained by refocusing the laser beam on the target and adding a pulsed flowing water film.

2.
Sci Rep ; 11(1): 23231, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34853364

ABSTRACT

Homing of circulating tumour cells (CTC) at distant sites represents a critical event in metastasis dissemination. In addition to physical entrapment, probably responsible of the majority of the homing events, the vascular system provides with geometrical factors that govern the flow biomechanics and impact on the fate of the CTC. Here we mathematically explored the distribution of velocities and the corresponding streamlines at the bifurcations of large blood vessel and characterized an area of low-velocity at the carina of bifurcation that favours the residence of CTC. In addition to this fluid physics effect, the adhesive capabilities of the CTC provide with a biological competitive advantage resulting in a marginal but systematic arrest as evidenced by dynamic in vitro recirculation in Y-microchannels and by perfusion in in vivo mice models. Our results also demonstrate that viscosity, as a main determinant of the Reynolds number that define flow biomechanics, may be modulated to limit or impair CTC accumulation at the bifurcation of blood vessels, in agreement with the apparent positive effect observed in the clinical setting by anticoagulants in advanced oncology disease.


Subject(s)
Blood Flow Velocity , Hemodynamics , Neoplastic Cells, Circulating , Animals , Cell Adhesion , Cell Line, Tumor , Human Umbilical Vein Endothelial Cells , Humans , Leukocytes, Mononuclear , Mice , Models, Cardiovascular , Models, Theoretical
3.
Mater Sci Eng C Mater Biol Appl ; 129: 112388, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34579907

ABSTRACT

Stereolithographic printers have revolutionized many manufacturing processes with their capacity to easily produce highly detailed structures. In the field of microfluidics, this technique avoids the use of complex steps and equipment of the conventional technologies. The potential of low force stereolithography technology is analysed for the first time using a Form 3B printer and seven printing resins through the fabrication of microchannels and pillars. Manufacturing performance of internal and superficial channels and pillars is studied for the seven printing resins in different configurations. A complete characterization of printed structures is carried out by optical, confocal and SEM microscopy, and EDX analysis. Internal channels with unobstructed lumen are obtained for diameters and angles greater than 500 µm and 60°, respectively. Outward and inward superficial channels in the range of hundreds of microns can be fabricated with an accurate profile, printing them with a perpendicular orientation respect to the base, allowing a proper uncured resin evacuation. Outward channels are replicated by soft lithography using polydimethylsiloxane. Clear, Model and Tough resins show a good behaviour to be used as master, but Amber and Dental resins present a poor topology transference from the master to the replica. According to the needs of devices used for biological and biomedical research, transparency as well as superficial biocompatibility of some resins is evaluated. Human umbilical vein endothelial cells (HUVEC) adhesion is confirmed on Amber, Dental and Clear resins, but these cells were only able to grow and progress as a cell culture over the Amber resin. Therefore, Amber showed an adequate biocompatibility, in terms of cell adhesion and growth for HUVEC.


Subject(s)
Lab-On-A-Chip Devices , Printing, Three-Dimensional , Human Umbilical Vein Endothelial Cells , Humans , Microfluidics , Stereolithography
4.
Eur J Pharm Biopharm ; 156: 165-175, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32891732

ABSTRACT

The use of pressure waves (PW) to disrupt the stratum corneum (SC) temporarily is an effective strategy to increase the deposition of drug molecules into the skin. However, given the rather modest outcomes when compared with ablation-assisted drug delivery, its potential has been underestimated. Accordingly, the aim of this study was to examine the impact of Resonant Amplitude Waves (RAWs) on increasing cutaneous delivery. RAW phenomena are triggered by focusing a high-peak-power pulsed laser onto an appropriate transducer structure, under space- and time-controlled resolution. In order to determine the optimal conditions for the generation and use of RAWs, a screening of laser parameters setting and an analysis of different geometries of the impact pattern over diverse materials used as transducers was performed, analyzing the footprint of the RAW waves in an agarose gel. The results obtained were then checked and fine-tuned using human skin samples instead of agarose. Furthermore, ex vivo experiments were carried out to characterize the effect of the RAWs in the cutaneous delivery of diclofenac (DIC) and lidocaine (LID) administered in the form of gels. The application of RAWs resulted in an increased delivery of DIC and LID to the skin, whose intensity was dependent on the composition of the formulation. In fact, the maximum observed for DIC and LID in short-time experiments (39.1 ± 11.1 and 153 ± 16 µg/cm2, respectively) was comparable to those observed using ablation-assisted drug delivery under the same conditions. In conclusion, the combination of RAWs with specific formulation strategies is a feasible alternative for the cutaneous delivery of drug candidates when short onset of action is required.


Subject(s)
Drug Delivery Systems/methods , Laser Therapy/methods , Lidocaine/administration & dosage , Lidocaine/metabolism , Skin/drug effects , Skin/metabolism , Administration, Cutaneous , Anesthetics, Local/administration & dosage , Anesthetics, Local/metabolism , Animals , Drug Delivery Systems/instrumentation , Humans , Laser Therapy/instrumentation , Organ Culture Techniques
5.
Biomater Res ; 24: 15, 2020.
Article in English | MEDLINE | ID: mdl-32944279

ABSTRACT

BACKGROUND: Cardio myoblast generation from conventional approaches is laborious and time-consuming. We present a bioelectronics on-a-chip for stimulating cells cardio myoblast proliferation during culture. METHOD: The bioelectronics chip fabrication methodology involves two different process. In the first step, an aluminum layer of 200 nm is deposited over a soda-lime glass substrate using physical vapor deposition and selectively removed using a Q-switched Nd:YVO4 laser to create the electric tracks. To perform the experiments, we developed a biochip composed of a cell culture chamber fabricated with polydimethylsiloxane (PDMS) with a glass coverslip or a cell culture dish placed over the electric circuit tracks. By using such a glass cover slip or cell culture dish we avoid any toxic reactions caused by electrodes in the culture or may be degraded by electrochemical reactions with the cell medium, which is crucial to determine the effective cell-device coupling. RESULTS: The chip was used to study the effect of electric field stimulation of Rat ventricular cardiomyoblasts cells (H9c2). Results shows a remarkable increase in the number of H9c2 cells for the stimulated samples, where after 72 h the cell density double the cell density of control samples. CONCLUSIONS: Cell proliferation of Rat ventricular cardiomyoblasts cells (H9c2) using the bioelectronics-on-a-chip was enhanced upon the electrical stimulation. The dependence on the geometrical characteristics of the electric circuit on the peak value and homogeneity of the electric field generated are analyzed and proper parameters to ensure a homogeneous electric field at the cell culture chamber are obtained. It can also be observed a high dependence of the electric field on the geometry of the electrostimulator circuit tracks and envisage the potential applications on electrophysiology studies, monitoring and modulate cellular behavior through the application of electric fields.

6.
J Occup Environ Hyg ; 17(9): 390-397, 2020 09.
Article in English | MEDLINE | ID: mdl-32795221

ABSTRACT

The SARS-CoV-2 pandemic has led to a global decrease in personal protective equipment (PPE), especially filtering facepiece respirators (FFRs). Ultraviolet-C wavelength is a promising way of decontamination, however adequate dosimetry is needed to ensure balance between over and underexposed areas and provide reliable results. Our study demonstrates that UVGI light irradiance varies significantly on different respirator angles and propose a method to decontaminate several masks at once ensuring appropriate dosage in shaded zones. An UVGI irradiator was built with internal dimensions of 69.5 × 55 × 33 cm with three 15 W UV lamps. Inside, a grating of 58 × 41 × 15 cm was placed to hold the masks. Two different flat fold respirator models were used to assess irradiance, four of model Aura 9322 3 M of dimensions 17 × 9 × 4 cm (tri-fold), and two of model SAFE 231FFP3NR (bi-fold) with dimensions 17 × 6 × 5 cm. An STN-SilverNova spectrometer was employed to verify wavelength spectrum and surface irradiance. A simulation was performed to find the irradiance pattern inside the box and the six masks placed inside. These simulations were carried out using the software DIALUX EVO 8.2. The data obtained reveal that the irradiance received inside the manufactured UVGI-irradiator depends not only on the distance between the lamps' plane and the base of the respirators but also on the orientation and shape of the masks. This point becomes relevant to assure that all the respirators inside the chamber receive the correct dosage. Irradiance over FFR surfaces depend on several factors such as distance and angle of incidence of the light source. Careful irradiance measurement and simulation can ensure reliable dosage in the whole mask surface, balancing overexposure. Closed box systems might provide a more reliable, reproducible UVGI dosage than open settings.


Subject(s)
Coronavirus Infections/epidemiology , Decontamination/methods , Pneumonia, Viral/epidemiology , Respiratory Protective Devices/microbiology , Ultraviolet Rays , Betacoronavirus , COVID-19 , Equipment Reuse , Humans , Pandemics , Radiation Dosage , SARS-CoV-2
7.
Sci Total Environ ; 742: 140507, 2020 Nov 10.
Article in English | MEDLINE | ID: mdl-32629255

ABSTRACT

A novel approach based on the direct pulsed irradiation of UV-C light onto ibuprofen (IBP) solutions was evaluated in this work, as proof of concept for the direct removal of micropollutants. The experiments confirmed that laser irradiation is able to completely degrade IBP in 15 min in distilled water, with a DOC depletion of ca. 25% and with transformation products (TPs) remaining in solution and estimated to represent ca. 10% of the initial IBP concentration. In wastewater spiked samples, removal efficiency is slightly lower but still significant (ca. 5% IBP remaining after 15 min). Hence, this work suggests that low power solid state pulsed lasers, emitting at 266 nm wavelength, show promise for the removal of these type of micropollutants from water. These results open new opportunities towards the development of chemical-free water treatment methods based on direct, selective irradiation using state of the art, miniaturized laser devices.


Subject(s)
Water Pollutants, Chemical/analysis , Water Purification , Ibuprofen , Wastewater , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...