Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters











Database
Language
Publication year range
1.
Can J Cardiol ; 31(3): 348-56, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25746024

ABSTRACT

BACKGROUND: The long-term effects of continuous-flow left ventricular assist device (CF-LVAD) support on trends of inflammatory markers over time are unknown. We examined the hypothesis that the levels of inflammatory markers in CF-LVAD recipients are higher than in healthy controls and that these levels increase over time with long-term CF-LVAD support. METHODS: We examined the levels of inflammatory markers longitudinally at baseline before CF-LVAD implantation and at 3, 6, and 9 months after implantation. We then compared the levels of inflammatory markers to those in a healthy control group. RESULTS: Compared with baseline values before CF-LVAD implantation, left ventricular end-diastolic diameter (LVEDd) and left ventricular end-systolic diameter (LVESd) decreased significantly at 3, 6, and 9 months after CF-LVAD implantation. Brain natriuretic peptide (BNP) levels dropped significantly after CF-LVAD implantation but did not normalize. Improvements in ejection fraction at 3, 6, and 9 months after CF-LVAD implantation did not reach significance. Monocyte chemoattractant protein-1, interferon γ-induced protein, and C-reactive protein levels were higher in the CF-LVAD recipients at each of the time points (baseline before CF-LVAD implantation and 3, 6, and 9 months after implantation) compared with levels in healthy controls. In CF-LVAD recipients, serum interleukin-8, tumour necrosis factor-α, and macrophage inflammatory protein-ß increased significantly at 9 months, and macrophage-derived chemokine increased at 6 months after CF-LVAD implantation compared with baseline. CONCLUSIONS: Despite improvements in LV dimensions and BNP levels, markers of inflammation remained higher in CF-LVAD recipients. High levels of inflammation in CF-LVAD recipients may result from heart failure preconditioning or the long-term device support, or both. Because inflammation may be detrimental to CF-LVAD recipients, future studies should determine whether inflammatory pathways are reversible.


Subject(s)
Biomarkers/blood , Heart Failure/blood , Heart Failure/therapy , Heart-Assist Devices , Inflammation/blood , Ventricular Function, Left , Adult , Aged , C-Reactive Protein/metabolism , Case-Control Studies , Chemokine CCL2/blood , Female , Heart Failure/diagnosis , Heart Failure/physiopathology , Humans , Interleukin-18/blood , Interleukin-8/blood , Longitudinal Studies , Male , Middle Aged , Natriuretic Agents/blood , Natriuretic Peptide, Brain/blood , Predictive Value of Tests , Sensitivity and Specificity , Severity of Illness Index , Tumor Necrosis Factor-alpha/blood
SELECTION OF CITATIONS
SEARCH DETAIL