Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Interact Cardiovasc Thorac Surg ; 32(4): 499-505, 2021 04 19.
Article in English | MEDLINE | ID: mdl-33881147

ABSTRACT

OBJECTIVES: Durability of sutureless aortic bioprosthetic valves remains a major issue. The aim of this study was to assess structural valve deterioration (SVD) and bioprosthetic valve failure (BVF) of the Perceval bioprosthesis using the new proposed standardized definitions. METHODS: All patients who underwent aortic valve replacement with sutureless Perceval S prostheses up to September 2016 were included. Clinical and echocardiographic follow-up was performed. New standardized definitions were used to assess the durability of sutureless bioprosthetic valves. From 2013 to 2016, 214 patients were included. RESULTS: The mean age and EuroSCORE II were 79 years and 2.74. Thirty-day mortality was 0.47%. The survival rate was 96.8%, 88.1% and 85.7% at 1, 3 and 4 years, respectively. The median echocardiographic follow-up was 3.28 years. The mean pressure gradient was 11.3 mmHg. No cases showed evidence of severe SVD, 17 patients had moderate SVD with a mean pressure gradient of 24 mmHg and 8 patients had definite late BVF. The incidence of moderate SVD and BVF at 4 years was 8.8% and 2.9%, respectively. CONCLUSIONS: Mid-term follow-up to 6.3 years after aortic valve replacement with the Perceval bioprosthesis documents favourable haemodynamic and clinical outcomes and low rates of SVD and BVF.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Bioprosthesis , Consensus , Humans , Prosthesis Design , Treatment Outcome
2.
Rev Esp Cardiol (Engl Ed) ; 74(4): 337-344, 2021 Apr.
Article in English, Spanish | MEDLINE | ID: mdl-32205100

ABSTRACT

INTRODUCTION AND OBJECTIVES: Two-dimensional speckle-tracking echocardiography has emerged as a promising alternative to endomyocardial biopsy to rule out acute cellular rejection after orthotopic heart transplantation (OHT) in single center studies. In an original cohort, 15.5% and 17% of cutoff points for left ventricular global longitudinal strain (LVGLS) and free-wall right ventricular longitudinal strain, respectively, achieved 100% negative predictive value to exclude moderate or severe acute cellular rejection (ACR ≥ 2R). Our objective was to demonstrate the usefulness of speckle-tracking and validate these cutoff points in an external cohort. METHODS: A prospective, multicenter study that included patients who were monitored during their first year after OHT was conducted. Echocardiographic studies analyzed by local investigators were compared with simultaneous paired endomyocardial biopsies samples. RESULTS: A total of 501 endomyocardial biopsy-echocardiographic studies were included in 99 patients. ACR≥2R was present in 7.4% of samples. LVGLS and free-wall right ventricular longitudinal strain were significantly reduced during ACR≥2R on univariate analysis. On multivariate analysis, LVGLS was independently associated with the presence of ACR≥2R. The original cutoff points demonstrated a negative predictive value of 94.3% to exclude ACR≥2R. CONCLUSIONS: This study maintained a strong negative predictive value to exclude ACR≥2R after OHT and LVGLS was independently associated with the presence of ACR≥2R. We propose the use of speckle-tracking, especially LVGLS, as part of the noninvasive diagnosis and management of ACR.


Subject(s)
Heart Transplantation , Echocardiography , Graft Rejection/diagnosis , Heart Ventricles/diagnostic imaging , Humans , Prospective Studies
3.
Int J Cardiovasc Imaging ; 33(1): 57-67, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27644405

ABSTRACT

LV torsion during exercise in patients with coronary artery disease (CAD) is not well known. Circumferential strain (CS) and left ventricular (LV) torsion (Tor) have not been evaluated during ischemia in these patients. We aimed to assess the effect of ischemia during exercise echocardiography (ExE) on CS and Tor. We studied a group of 73 patients with true positive ExE results (Ischemic group: ischemia plus an abnormal coronary angiogram) and a matched control group of 66 patients with negative ExE and either normal coronary angiography or low post-test probability of CAD. Basal rotation (Rot) and apical rotation and basal and apical CS were studied by speckle tracking at rest and exercise. Apical CS and apical and basal Rot values were similar between groups at rest, except basal CS which was already worse in the ischemic group. At exercise, all rotational and CS parameters were impaired in the ischemic in comparison with the control group (basal CS: -18 ± 5 vs. -25 ± 7 %, p < 0.001; apical CS: -31 ± 11 vs. - 43 ± 9 %, p < 0.001; time to basal CS: 52 ± 6 vs. 48 ± 7 %, p = 0.001; time to apical CS: 55 ± 7 vs. 49 ± 6 %, p < 0.001; basal rotation: -0.7 ± 6.5° vs. -6.2 ± 8.5°, p < 0.001; LV twist 13.0 ± 10.4° vs.19.7 ± 11.5°, p < 0.001; LV-Tor 1.9 ± 1.6°/cm vs. 2.8 ± 1.7˚/cm, p = 0.001) with the exception of apical rotation which was similar (12.3 ± 7.4° vs. 13.4 ± 7.7°, p = NS). Basal and apical CS and basal rotation impair during exercise-induced ischemia. LV-Tor decreases with ischemia due to worsening of basal rotation, whereas apical rotation does not impair, suggesting the existence of an apical compensatory mechanism.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Echocardiography, Stress/methods , Exercise Test , Exercise , Myocardial Contraction , Myocardial Ischemia/diagnostic imaging , Ventricular Function, Left , Adaptation, Physiological , Aged , Biomechanical Phenomena , Case-Control Studies , Coronary Angiography , Coronary Artery Disease/etiology , Coronary Artery Disease/physiopathology , Female , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Myocardial Ischemia/physiopathology , Predictive Value of Tests , Stress, Mechanical , Torsion, Mechanical
SELECTION OF CITATIONS