Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Chemosphere ; 349: 140834, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38042421

ABSTRACT

Beauty salons (BS) are places that deal with a wide range of cosmetics with potentially hazardous chemicals, and their effluent should be properly treated before going to the sewage system, once it represents characteristics of industrial wastewater. This work provides an extensive characterization of a BS effluent and its respective electrochemical treatment by comparing NaCl, Na2SO4, and Na2S2O8 as supporting electrolytes with a boron-doped diamond (BDD) as anode, applying 10 or 30 mA cm-2 of current density (j). The inclusion of UVC irradiation was also performed but the improvements achieved in removing the organic matter were null or lower. The analysis of chemical oxygen demand (COD) removal, energy consumption, and total current efficiency (TCE) was required to prove the efficacy of the processes and the comparative study of the performance of different technologies. Precipitate analysis was also done due to the high turbidity of the raw effluent and the appearance of a precipitate before and during the electrolysis, mainly with Na2S2O8. The precipitate confirmed the presence of silicates and small amounts of heavy metals. The results clearly showed that 6 h of treatment with Na2SO4 achieved 58% of COD removal with an energy consumption of about 0.52 kWh m-3, being the best electrolyte option for treating BS effluent by applying 10 mA cm-2. Under these experimental conditions, the final wastewater can be directly discharged into the sewage system with a lower amount of visible precipitate, and with 73% less turbidity. The treatment here proposed can be used as an alternative to decision-makers and governments once it can be a step further in the implementation of better and advanced politics of water sanitation.


Subject(s)
Wastewater , Water Pollutants, Chemical , Oxidation-Reduction , Sewage , Sulfates/analysis , Water Pollutants, Chemical/analysis , Electrolytes , Diamond/chemistry , Electrodes
2.
MethodsX ; 11: 102300, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37577171

ABSTRACT

Aiming the decentralization of monitoring policies and to facilitate the work of researchers, mainly in developing countries, the present method deals with the explanation of a simple and rapid protocol for chemical oxygen demand (COD) analysis through the use of digital smartphone devices coupled with a camera and a free app available for Android operating system that recognizes HSV (hue, saturation, value). The calibration of the method is done based on the theoretical values of potassium hydrogen phthalate for a proper and reliable build of the calibration curve by using the smartphone-based technique and the digested samples of COD. The coefficient of determination (R2) attained a value upper than 0.99, providing a high confidence levels, and the method achieved 97% of average accuracy in samples with COD values ranging from 0 to 150 mg L-1. Finally, the procedure here presented can be a great support for scientific laboratories and monitoring policies, once it can efficiently substitute expensive spectrophotometers and can improve and ensure the sustainable management of water sanitation, which is one of the sustainable goals proposed by the United Nations.•COD measurements, based on the use of a simple smartphone with a camera, can be a promising way for environmental analysis when spectrophotometers are not available, such as decentralized approaches.•The use of smartphone protocol is a novel initiative to fulfill sustainable development goal 6 on clean water and sanitation.•The smartphone is capable to read the difference of HSV values efficiently and can substitute the use of expensive spectrophotometers.

3.
Sci Rep ; 13(1): 11082, 2023 Jul 08.
Article in English | MEDLINE | ID: mdl-37422460

ABSTRACT

This study is focused on a proposal of a smartphone imaging-based quantification for providing a simple and rapid method for the analysis of chemical oxygen demand (COD) and color throughout the use of the HSV and/or RGB model in digital devices. For COD, calibration curves were done based on the theoretical values of potassium biphthalate for a proper comparison between the spectrophotometer and the smartphone techniques. The smartphone camera and application attain an average accuracy higher than the analysis in the spectrophotometer (98.3 and 96.2%, respectively). In the color analysis, it was demonstrated that only the UV-vis bands measurement is not feasible to perform the real abatement of the dye in the water because the limiting concentration that allows obtaining a linear relationship in this equipment related to the dye concentration is about 10 mg L-1. Above this value, the spectrophotometer can not reach the real difference of color in the solution. Meanwhile, the smartphone method by using the camera reaches linearity until 50 mg L-1. From an environmental point of view, smartphones have been used for monitoring several organic and inorganic pollutants, however, no attempts have been published related to their use to evaluate the color and COD during wastewater treatment. Therefore, this investigation also aims to assess the utilization of these methods, for the first time, when high-colored water polluted by methylene blue (MB) was electrochemically treated by using a boron-dopped diamond (BDD) as the anode, with different current densities (j = 30, 45, 60, and 90 mA cm-2). COD and color abatement results clearly showed that different organic matter/color removal efficiencies were achieved, depending on the j used. All the results are aligned with the studies already available in the literature, with the total removal of color in 120 min of electrolysis with 60 and 90 mA cm-2, and almost 80% of COD abatement with the higher j. Moreover, samples of real effluent from beauty salons were compared, with standard deviation varying from only 3 to 40 mg O2 L-1, which is acceptable for COD values close to 2000. Finally, the methods here presented can be a great benefit for public water monitoring policies, since it is cheap and has a decentralized characteristic, given that smartphones are very common and portable devices.


Subject(s)
Smartphone , Water Pollutants, Chemical , Biological Oxygen Demand Analysis , Electrolysis/methods , Water , Electrodes , Oxidation-Reduction
4.
Sci Total Environ ; 855: 158816, 2023 Jan 10.
Article in English | MEDLINE | ID: mdl-36115407

ABSTRACT

This study aims to develop a cheap method for the evaluation of quality of water or the assessment of the treatment of water by chemical oxygen demand (COD) measurements throughout the use of the HSV color model in digital devices. A free application installed on a smartphone was used for analyzing the images in which the colors were acquired before to be quantified. The proposed method was also validated by the standard and spectrophotometric methods, demonstrating that no significant statistical differences were attained (average accuracy of 97 %). With these results, the utilization of this smartphone-based method for COD analysis was used/evaluated, for first time, by treating electrochemically a real water matrix with substantial organic and salts content using BDD and Pt/Ti anodes. Aiming to understand the performance of both anodes, bulk experiments were performed under real pH by applying current densities (j) of 15, 30, and 60 mA cm-2. COD abatement results (which were achieved with this novel smart water security solution) clearly showed that different organic matter removal efficiencies were achieved, depending on the electrocatalytic material used as well as the applied current density (42 %, 45 %, and 85 % for Ti/Pt while 93 %, 97 % and total degradation for BDD by applying 15, 30, and 60 mA cm-2, respectively). However, when the persulfate-mediated oxidation approach was used, with the addition of 2 or 4 g Na2SO4 L-1, COD removal efficiencies were enhanced, obtaining total degradation with 4 g Na2SO4 L-1 and by applying 15 mA cm-2. Finally, this smartphone imaging-based method provides a simple and rapid method for the evaluation of COD during the use of electrochemical remediation technology, developing and decentralizing analytics technologies for smart water solutions which play a key role in achieving the Sustainable Development Goal 6 (SDG6).


Subject(s)
Wastewater , Water Pollutants, Chemical , Wastewater/chemistry , Biological Oxygen Demand Analysis , Smartphone , Cost-Benefit Analysis , Electrodes , Water Pollutants, Chemical/chemistry , Oxidation-Reduction , Water
SELECTION OF CITATIONS
SEARCH DETAIL