Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Hip Int ; 33(6): 1049-1055, 2023 Nov.
Article in English | MEDLINE | ID: mdl-35706125

ABSTRACT

BACKGROUND: Mortality following revision hip surgery for periprosthetic fracture (PPF) is comparable to neck of femur fractures. Our institution provides a regional "PPF Service". The aim of this study was to determine the time to surgery and mortality rate for PPF, compared to revision for infection or aseptic loosening. METHODS: Revision arthroplasty procedures performed for PPF, infection or aseptic loosening between January 2014 and December 2015 were identified. Comparisons were made between the 3 groups for baseline demographics, admission to higher-level care, length of stay, complications and mortality. RESULTS: There were 37 PPF, 71 infected and 221 aseptic revisions. PPF had a higher proportion of females (65% vs. 39% in infection and 53% in aseptic; p = 0.031) and grade 3 and 4 ASA patients (p = 0.006). Median time to surgery for PPF was 8 days (95% CI, 6-16). Single-stage procedures were performed in 84% of PPF, 42% of infections and 99% of aseptic revisions (p < 0.001). 19% of PPF revisions required HDU admission, 1% in the aseptic group and none in the infection group. Median length of stay was significantly different (PPF 10; infection 14; aseptic 8 days (p < 0.001). The 1-year mortality rate for PPF was 0%, 2.8% for infection and 0.9% in the aseptic group (p = 0.342). CONCLUSIONS: Despite the PPF group having higher ASA grades and more HDU admissions, our 1-year mortality rate was 0% and not significantly different to infection or aseptic loosening. Our low complication and 1-year mortality rate is encouraging and supports the safety of a regional "Periprosthetic Fracture Service".


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Periprosthetic Fractures , Female , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Periprosthetic Fractures/surgery , Periprosthetic Fractures/complications , Prosthesis Failure , Reoperation/methods , Femoral Fractures/surgery , Retrospective Studies
2.
Eur J Orthop Surg Traumatol ; 29(6): 1243-1251, 2019 Aug.
Article in English | MEDLINE | ID: mdl-30929082

ABSTRACT

INTRODUCTION: The ideal method and implant to perform total hip arthroplasty (THA) is still a debated topic. Ceramic on ceramic (CoC) bearings have favourable wear properties, but squeaking has been reported as an unwanted side effect. We aimed to determine the rate of noise generation from CoC hips and investigate whether there is a relationship with patient satisfaction. METHODS: A total of 246 consecutive CoC bearing uncemented THA were retrospectively identified in a single institution. Post-operatively patients were sent a postal questionnaire to evaluate their reported sounds and satisfaction with their THA. Uni- and multi-variate analyses were performed to identify potential predictor variables for reported post-operative sounds. RESULTS: Questionnaires were returned by 172 patients (70% return rate). 24% reported sounds from their hips with 11% reporting a squeak. Median satisfaction levels were minimally, but significantly less for "noisy" (9/10) than "quiet" hips (10/10) (median difference = - 1, 95% CI - 2 to 0, p < 0.001). Compared to those with "noisy" hips, patients with "quiet" hips were 1.7 times (95% CI 1.3-2.5, p = 0.0002) more likely to report a "forgotten" hip. Younger age (p < 0.043) and increased anteversion (p < 0.021) were predictors for reported sounds. CONCLUSION: We have identified a high rate of "noisy" hips in this series of CoC THA with a significant inverse relationship between "noisy" hips and patient satisfaction levels. In our unit, we are moving towards the use of ceramic on cross-linked polyethylene bearings as a result of these findings and the excellent survivorship of this bearing combination.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/adverse effects , Noise/prevention & control , Postoperative Complications , Prosthesis Failure/etiology , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Ceramics/therapeutic use , Female , Humans , Male , Middle Aged , Patient Reported Outcome Measures , Patient Satisfaction , Polyethylene/therapeutic use , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Postoperative Complications/psychology , Prosthesis Design , Retrospective Studies , Surveys and Questionnaires
3.
Eur J Orthop Surg Traumatol ; 29(1): 97-102, 2019 Jan.
Article in English | MEDLINE | ID: mdl-29855788

ABSTRACT

INTRODUCTION: It has been suggested that one of the factors related to persistent post-operative pain following total hip arthroplasty (THA) is to over sizing of the acetabular component. In order to investigate this potential issue, we retrospectively analysed a series of consecutive uncemented THA. We assessed the incidence of persistent post-operative pain and the size difference between the implanted acetabular component and the native femoral head. METHODS: A total of 265 consecutive THAs were retrospectively identified. Standardised pre-operative radiographs were analysed using validated techniques to determine the native femoral head diameter. Post-operative standardised radiographs were reviewed and the acetabular orientation determined. Patients were sent postal questionnaires regarding their outcome and level of pain. RESULTS: Questionnaires were returned by 169 patients (189 hips, 71% response rate). A total of 17 were excluded due to inadequate radiographs., leaving 172 THA in the study group. The mean native femoral head (NFH) size was 47 mm. The most common implanted acetabular component size was 52 mm. The mean difference in cup to NFH diameter (delta) was 5.7 mm (range - 6.1 to 15.4 mm; 95% CI 5.3-6.2 mm). A delta of > 6 mm was found to be significant for predicting persistent post-operative pain (RR = 1.81; 95% CI 1.1-3.1; P = 0.027). CONCLUSION: Our study confirms that a delta of > 6 mm is associated with an increased risk of persistent post-operative pain following THA. We recommend pre-operative templating in all uncemented THA to ensure the planned acetabular component is no more than 6 mm larger than the NFH diameter.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Femur Head/anatomy & histology , Hip Prosthesis/adverse effects , Pain, Postoperative/etiology , Prosthesis Design/adverse effects , Acetabulum/surgery , Adult , Aged , Female , Femur Head/diagnostic imaging , Humans , Male , Middle Aged , Organ Size , Radiography , Retrospective Studies , Risk Factors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...