Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
Add more filters










Publication year range
1.
Phys Rev Lett ; 130(17): 173201, 2023 Apr 28.
Article in English | MEDLINE | ID: mdl-37172237

ABSTRACT

We demonstrate that x-ray fluorescence emission, which cannot maintain a stationary interference pattern, can be used to obtain images of structures by recording photon-photon correlations in the manner of the stellar intensity interferometry of Hanbury Brown and Twiss. This is achieved utilizing femtosecond-duration pulses of a hard x-ray free-electron laser to generate the emission in exposures comparable to the coherence time of the fluorescence. Iterative phasing of the photon correlation map generated a model-free real-space image of the structure of the emitters. Since fluorescence can dominate coherent scattering, this may enable imaging uncrystallised macromolecules.

2.
IUCrJ ; 8(Pt 4): 665-677, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34258014

ABSTRACT

The crystallization of recombinant proteins in living cells is an exciting new approach in structural biology. Recent success has highlighted the need for fast and efficient diffraction data collection, optimally directly exposing intact crystal-containing cells to the X-ray beam, thus protecting the in cellulo crystals from environmental challenges. Serial femtosecond crystallography (SFX) at free-electron lasers (XFELs) allows the collection of detectable diffraction even from tiny protein crystals, but requires very fast sample exchange to utilize each XFEL pulse. Here, an efficient approach is presented for high-resolution structure elucidation using serial femtosecond in cellulo diffraction of micometre-sized crystals of the protein HEX-1 from the fungus Neurospora crassa on a fixed target. Employing the fast and highly accurate Roadrunner II translation-stage system allowed efficient raster scanning of the pores of micro-patterned, single-crystalline silicon chips loaded with living, crystal-containing insect cells. Compared with liquid-jet and LCP injection systems, the increased hit rates of up to 30% and reduced background scattering enabled elucidation of the HEX-1 structure. Using diffraction data from only a single chip collected within 12 min at the Linac Coherent Light Source, a 1.8 Šresolution structure was obtained with significantly reduced sample consumption compared with previous SFX experiments using liquid-jet injection. This HEX-1 structure is almost superimposable with that previously determined using synchrotron radiation from single HEX-1 crystals grown by sitting-drop vapour diffusion, validating the approach. This study demonstrates that fixed-target SFX using micro-patterned silicon chips is ideally suited for efficient in cellulo diffraction data collection using living, crystal-containing cells, and offers huge potential for the straightforward structure elucidation of proteins that form intracellular crystals at both XFELs and synchrotron sources.

3.
Science ; 372(6542): 642-646, 2021 05 07.
Article in English | MEDLINE | ID: mdl-33811162

ABSTRACT

The coronavirus disease (COVID-19) caused by SARS-CoV-2 is creating tremendous human suffering. To date, no effective drug is available to directly treat the disease. In a search for a drug against COVID-19, we have performed a high-throughput x-ray crystallographic screen of two repurposing drug libraries against the SARS-CoV-2 main protease (Mpro), which is essential for viral replication. In contrast to commonly applied x-ray fragment screening experiments with molecules of low complexity, our screen tested already-approved drugs and drugs in clinical trials. From the three-dimensional protein structures, we identified 37 compounds that bind to Mpro In subsequent cell-based viral reduction assays, one peptidomimetic and six nonpeptidic compounds showed antiviral activity at nontoxic concentrations. We identified two allosteric binding sites representing attractive targets for drug development against SARS-CoV-2.


Subject(s)
Allosteric Site , Antiviral Agents/chemistry , Catalytic Domain , Coronavirus 3C Proteases/antagonists & inhibitors , Coronavirus 3C Proteases/chemistry , Drug Development , Protease Inhibitors/chemistry , SARS-CoV-2/enzymology , Animals , Antiviral Agents/pharmacology , Chlorocebus aethiops , Crystallography, X-Ray , Drug Evaluation, Preclinical , Protease Inhibitors/pharmacology , SARS-CoV-2/drug effects , Vero Cells , Virus Replication/drug effects
4.
Sci Rep ; 10(1): 1784, 2020 02 04.
Article in English | MEDLINE | ID: mdl-32019946

ABSTRACT

Studies of biological systems typically require the application of several complementary methods able to yield statistically-relevant results at a unique level of sensitivity. Combined X-ray fluorescence and ptychography offer excellent elemental and structural imaging contrasts at the nanoscale. They enable a robust correlation of elemental distributions with respect to the cellular morphology. Here we extend the applicability of the two modalities to higher X-ray excitation energies, permitting iron mapping. Using a long-range scanning setup, we applied the method to two vital biomedical cases. We quantified the iron distributions in a population of macrophages treated with Mycobacterium-tuberculosis-targeting iron-oxide nanocontainers. Our work allowed to visualize the internalization of the nanocontainer agglomerates in the cytosol. From the iron areal mass maps, we obtained a distribution of antibiotic load per agglomerate and an average areal concentration of nanocontainers in the agglomerates. In the second application we mapped the calcium content in a human bone matrix in close proximity to osteocyte lacunae (perilacunar matrix). A concurrently acquired ptychographic image was used to remove the mass-thickness effect from the raw calcium map. The resulting ptychography-enhanced calcium distribution allowed then to observe a locally lower degree of mineralization of the perilacunar matrix.


Subject(s)
Bone Matrix/diagnostic imaging , Bone Remodeling/physiology , Calcium/metabolism , Macrophages/metabolism , Multimodal Imaging/methods , Animals , Bone Matrix/metabolism , Mice , X-Rays
5.
IUCrJ ; 6(Pt 4): 714-728, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31316815

ABSTRACT

Efficient and reliable sample delivery has remained one of the bottlenecks for serial crystallography experiments. Compared with other methods, fixed-target sample delivery offers the advantage of significantly reduced sample consumption and shorter data collection times owing to higher hit rates. Here, a new method of on-chip crystallization is reported which allows the efficient and reproducible growth of large numbers of protein crystals directly on micro-patterned silicon chips for in-situ serial crystallography experiments. Crystals are grown by sitting-drop vapor diffusion and previously established crystallization conditions can be directly applied. By reducing the number of crystal-handling steps, the method is particularly well suited for sensitive crystal systems. Excessive mother liquor can be efficiently removed from the crystals by blotting, and no sealing of the fixed-target sample holders is required to prevent the crystals from dehydrating. As a consequence, 'naked' crystals are obtained on the chip, resulting in very low background scattering levels and making the crystals highly accessible for external manipulation such as the application of ligand solutions. Serial diffraction experiments carried out at cryogenic temperatures at a synchrotron and at room temperature at an X-ray free-electron laser yielded high-quality X-ray structures of the human membrane protein aquaporin 2 and two new ligand-bound structures of thermolysin and the human kinase DRAK2. The results highlight the applicability of the method for future high-throughput on-chip screening of pharmaceutical compounds.

6.
Nat Commun ; 9(1): 1836, 2018 05 09.
Article in English | MEDLINE | ID: mdl-29743480

ABSTRACT

Here we present a new approach to diffraction imaging of amyloid fibrils, combining a free-standing graphene support and single nanofocused X-ray pulses of femtosecond duration from an X-ray free-electron laser. Due to the very low background scattering from the graphene support and mutual alignment of filaments, diffraction from tobacco mosaic virus (TMV) filaments and amyloid protofibrils is obtained to 2.7 Å and 2.4 Å resolution in single diffraction patterns, respectively. Some TMV diffraction patterns exhibit asymmetry that indicates the presence of a limited number of axial rotations in the XFEL focus. Signal-to-noise levels from individual diffraction patterns are enhanced using computational alignment and merging, giving patterns that are superior to those obtainable from synchrotron radiation sources. We anticipate that our approach will be a starting point for further investigations into unsolved structures of filaments and other weakly scattering objects.


Subject(s)
Amyloid/chemistry , Graphite/chemistry , X-Ray Diffraction/methods , Humans , Kinetics , X-Ray Diffraction/instrumentation
7.
J Synchrotron Radiat ; 24(Pt 6): 1296-1298, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-29091073

ABSTRACT

The success of diffraction experiments from weakly scattering samples strongly depends on achieving an optimal signal-to-noise ratio. This is particularly important in single-particle imaging experiments where diffraction signals are typically very weak and the experiments are often accompanied by significant background scattering. A simple way to tremendously reduce background scattering by placing an aperture downstream of the sample has been developed and its application in a single-particle X-ray imaging experiment at FLASH is demonstrated. Using the concept of a post-sample aperture it was possible to reduce the background scattering levels by two orders of magnitude.

8.
IUCrJ ; 4(Pt 6): 795-811, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-29123682

ABSTRACT

Serial diffraction data collected at the Linac Coherent Light Source from crystalline amyloid fibrils delivered in a liquid jet show that the fibrils are well oriented in the jet. At low fibril concentrations, diffraction patterns are recorded from single fibrils; these patterns are weak and contain only a few reflections. Methods are developed for determining the orientation of patterns in reciprocal space and merging them in three dimensions. This allows the individual structure amplitudes to be calculated, thus overcoming the limitations of orientation and cylindrical averaging in conventional fibre diffraction analysis. The advantages of this technique should allow structural studies of fibrous systems in biology that are inaccessible using existing techniques.

10.
Sci Rep ; 7: 44628, 2017 03 16.
Article in English | MEDLINE | ID: mdl-28300169

ABSTRACT

Serial femtosecond crystallography requires reliable and efficient delivery of fresh crystals across the beam of an X-ray free-electron laser over the course of an experiment. We introduce a double-flow focusing nozzle to meet this challenge, with significantly reduced sample consumption, while improving jet stability over previous generations of nozzles. We demonstrate its use to determine the first room-temperature structure of RNA polymerase II at high resolution, revealing new structural details. Moreover, the double-flow focusing nozzles were successfully tested with three other protein samples and the first room temperature structure of an extradiol ring-cleaving dioxygenase was solved by utilizing the improved operation and characteristics of these devices [corrected].


Subject(s)
Crystallography/instrumentation , Rheology/instrumentation , Computer Simulation , RNA Polymerase II/chemistry , Saccharomyces cerevisiae/enzymology , Temperature , Time Factors , X-Ray Diffraction
11.
Sci Data ; 3: 160060, 2016 Aug 01.
Article in English | MEDLINE | ID: mdl-27479754

ABSTRACT

Free-electron lasers (FEL) hold the potential to revolutionize structural biology by producing X-ray pules short enough to outrun radiation damage, thus allowing imaging of biological samples without the limitation from radiation damage. Thus, a major part of the scientific case for the first FELs was three-dimensional (3D) reconstruction of non-crystalline biological objects. In a recent publication we demonstrated the first 3D reconstruction of a biological object from an X-ray FEL using this technique. The sample was the giant Mimivirus, which is one of the largest known viruses with a diameter of 450 nm. Here we present the dataset used for this successful reconstruction. Data-analysis methods for single-particle imaging at FELs are undergoing heavy development but data collection relies on very limited time available through a highly competitive proposal process. This dataset provides experimental data to the entire community and could boost algorithm development and provide a benchmark dataset for new algorithms.


Subject(s)
Mimiviridae , X-Ray Diffraction , Algorithms , Computer Simulation , Crystallography, X-Ray , Data Collection , Electrons , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Lasers , Models, Theoretical , Particle Size , Scattering, Radiation , X-Rays
12.
Sci Rep ; 5: 9892, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-26030003

ABSTRACT

The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilise their capability for imaging and probing biological cells, nanodevices, and functional matter on the nanometer scale with chemical sensitivity. Here we demonstrate focusing a hard X-ray beam to an 8 nm focus using a volume zone plate (also referred to as a wedged multilayer Laue lens). This lens was constructed using a new deposition technique that enabled the independent control of the angle and thickness of diffracting layers to microradian and nanometer precision, respectively. This ensured that the Bragg condition is satisfied at each point along the lens, leading to a high numerical aperture that is limited only by its extent. We developed a phase-shifting interferometric method based on ptychography to characterise the lens focus. The precision of the fabrication and characterisation demonstrated here provides the path to efficient X-ray optics for imaging at 1 nm resolution.

13.
Opt Express ; 22(23): 28914-25, 2014 Nov 17.
Article in English | MEDLINE | ID: mdl-25402130

ABSTRACT

We use a Mach-Zehnder type autocorrelator to split and delay XUV pulses from the FLASH soft X-ray laser for triggering and subsequently probing the explosion of aerosolised sugar balls. FLASH was running at 182 eV photon energy with pulses of 70 fs duration. The delay between the pump-probe pulses was varied between zero and 5 ps, and the pulses were focused to reach peak intensities above 10¹6W/cm² with an off-axis parabola. The direct pulse triggered the explosion of single aerosolised sucrose nano-particles, while the delayed pulse probed the exploding structure. The ejected ions were measured by ion time of flight spectrometry, and the particle sizes were measured by coherent diffractive imaging. The results show that sucrose particles of 560-1000 nm diameter retain their size for about 500 fs following the first exposure. Significant sample expansion happens between 500 fs and 1 ps. We present simulations to support these observations.


Subject(s)
Electrons , Imaging, Three-Dimensional/methods , Lasers , Nanospheres/chemistry , Spectrum Analysis/methods , Sucrose/chemistry , Computer Simulation , Hydrogen/chemistry , Ions , Thermodynamics , X-Rays
14.
Opt Express ; 22(7): 8085-93, 2014 Apr 07.
Article in English | MEDLINE | ID: mdl-24718184

ABSTRACT

Knowledge of the sequence of different conformational states of a protein molecule is key to better understanding its biological function. A diffraction pattern from a single conformational state can be captured with an ultrafast X-ray Free-Electron Laser (XFEL) before the target is completely annihilated by the radiation. In this paper, we report the first experimental demonstration of conformation sequence recovery using diffraction patterns from randomly ordered conformations of a non-periodic object using the dimensional reduction technique Isomap and coherent diffraction imaging.

15.
Opt Express ; 21(10): 12385-94, 2013 May 20.
Article in English | MEDLINE | ID: mdl-23736456

ABSTRACT

Characterizing intense, focused x-ray free electron laser (FEL) pulses is crucial for their use in diffractive imaging. We describe how the distribution of average phase tilts and intensities on hard x-ray pulses with peak intensities of 10(21) W/m(2) can be retrieved from an ensemble of diffraction patterns produced by 70 nm-radius polystyrene spheres, in a manner that mimics wavefront sensors. Besides showing that an adaptive geometric correction may be necessary for diffraction data from randomly injected sample sources, our paper demonstrates the possibility of collecting statistics on structured pulses using only the diffraction patterns they generate and highlights the imperative to study its impact on single-particle diffractive imaging.


Subject(s)
Aerosols/analysis , Aerosols/chemistry , Lasers , Photometry/methods , Refractometry/methods , Surface Plasmon Resonance/methods , X-Rays , Electrons , Equipment Design , Equipment Failure Analysis , Microspheres
16.
Opt Express ; 21(23): 28729-42, 2013 Nov 18.
Article in English | MEDLINE | ID: mdl-24514385

ABSTRACT

Single shot diffraction imaging experiments via X-ray free-electron lasers can generate as many as hundreds of thousands of diffraction patterns of scattering objects. Recovering the real space contrast of a scattering object from these patterns currently requires a reconstruction process with user guidance in a number of steps, introducing severe bottlenecks in data processing. We present a series of measures that replace user guidance with algorithms that reconstruct contrasts in an unsupervised fashion. We demonstrate the feasibility of automating the reconstruction process by generating hundreds of contrasts obtained from soot particle diffraction experiments.

17.
Opt Express ; 20(4): 4149-58, 2012 Feb 13.
Article in English | MEDLINE | ID: mdl-22418172

ABSTRACT

We describe femtosecond X-ray diffraction data sets of viruses and nanoparticles collected at the Linac Coherent Light Source. The data establish the first large benchmark data sets for coherent diffraction methods freely available to the public, to bolster the development of algorithms that are essential for developing this novel approach as a useful imaging technique. Applications are 2D reconstructions, orientation classification and finally 3D imaging by assembling 2D patterns into a 3D diffraction volume.

18.
Opt Express ; 20(3): 2706-16, 2012 Jan 30.
Article in English | MEDLINE | ID: mdl-22330507

ABSTRACT

We demonstrate the use of an X-ray free electron laser synchronized with an optical pump laser to obtain X-ray diffraction snapshots from the photoactivated states of large membrane protein complexes in the form of nanocrystals flowing in a liquid jet. Light-induced changes of Photosystem I-Ferredoxin co-crystals were observed at time delays of 5 to 10 µs after excitation. The result correlates with the microsecond kinetics of electron transfer from Photosystem I to ferredoxin. The undocking process that follows the electron transfer leads to large rearrangements in the crystals that will terminally lead to the disintegration of the crystals. We describe the experimental setup and obtain the first time-resolved femtosecond serial X-ray crystallography results from an irreversible photo-chemical reaction at the Linac Coherent Light Source. This technique opens the door to time-resolved structural studies of reaction dynamics in biological systems.


Subject(s)
Crystallography, X-Ray/methods , Ferredoxins/ultrastructure , Lasers , Nanostructures/ultrastructure , X-Ray Diffraction/methods , Electrons , Protein Conformation , X-Rays
19.
Nat Methods ; 9(3): 263-5, 2012 Jan 29.
Article in English | MEDLINE | ID: mdl-22286383

ABSTRACT

X-ray free electron laser (X-FEL)-based serial femtosecond crystallography is an emerging method with potential to rapidly advance the challenging field of membrane protein structural biology. Here we recorded interpretable diffraction data from micrometer-sized lipidic sponge phase crystals of the Blastochloris viridis photosynthetic reaction center delivered into an X-FEL beam using a sponge phase micro-jet.


Subject(s)
Crystallography, X-Ray/methods , Lipid Bilayers/chemistry , Membrane Proteins/chemistry , Membrane Proteins/ultrastructure , Protein Binding , Protein Conformation/radiation effects , X-Rays
20.
Nat Methods ; 9(3): 259-62, 2012 Jan 29.
Article in English | MEDLINE | ID: mdl-22286384

ABSTRACT

Protein crystallization in cells has been observed several times in nature. However, owing to their small size these crystals have not yet been used for X-ray crystallographic analysis. We prepared nano-sized in vivo-grown crystals of Trypanosoma brucei enzymes and applied the emerging method of free-electron laser-based serial femtosecond crystallography to record interpretable diffraction data. This combined approach will open new opportunities in structural systems biology.


Subject(s)
Crystallography, X-Ray/methods , Crystallography/methods , Proteins/chemistry , Proteins/ultrastructure , Protein Binding/radiation effects , Protein Conformation/radiation effects , Proteins/radiation effects , Solubility/radiation effects , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...