Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
Add more filters










Publication year range
2.
Rev Sci Instrum ; 94(5)2023 May 01.
Article in English | MEDLINE | ID: mdl-37191465

ABSTRACT

Control noise is a limiting factor in the low-frequency performance of the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO). In this paper, we model the effects of using new sensors called Homodyne Quadrature Interferometers (HoQIs) to control the suspension resonances. We show that if we were to use HoQIs, instead of the standard shadow sensors, we could suppress resonance peaks up to tenfold more while simultaneously reducing the noise injected by the damping system. Through a cascade of effects, this will reduce the resonant cross-coupling of the suspensions, allow for improved stability for feed-forward control, and result in improved sensitivity of the detectors in the 10-20 Hz band. This analysis shows that improved local sensors, such as HoQIs, should be used in current and future detectors to improve low-frequency performance.

3.
Phys Rev Lett ; 113(23): 231101, 2014 Dec 05.
Article in English | MEDLINE | ID: mdl-25526109

ABSTRACT

Gravitational waves from a variety of sources are predicted to superpose to create a stochastic background. This background is expected to contain unique information from throughout the history of the Universe that is unavailable through standard electromagnetic observations, making its study of fundamental importance to understanding the evolution of the Universe. We carry out a search for the stochastic background with the latest data from the LIGO and Virgo detectors. Consistent with predictions from most stochastic gravitational-wave background models, the data display no evidence of a stochastic gravitational-wave signal. Assuming a gravitational-wave spectrum of Ω_{GW}(f)=Ω_{α}(f/f_{ref})^{α}, we place 95% confidence level upper limits on the energy density of the background in each of four frequency bands spanning 41.5-1726 Hz. In the frequency band of 41.5-169.25 Hz for a spectral index of α=0, we constrain the energy density of the stochastic background to be Ω_{GW}(f)<5.6×10^{-6}. For the 600-1000 Hz band, Ω_{GW}(f)<0.14(f/900 Hz)^{3}, a factor of 2.5 lower than the best previously reported upper limits. We find Ω_{GW}(f)<1.8×10^{-4} using a spectral index of zero for 170-600 Hz and Ω_{GW}(f)<1.0(f/1300 Hz)^{3} for 1000-1726 Hz, bands in which no previous direct limits have been placed. The limits in these four bands are the lowest direct measurements to date on the stochastic background. We discuss the implications of these results in light of the recent claim by the BICEP2 experiment of the possible evidence for inflationary gravitational waves.

4.
Phys Rev Lett ; 113(1): 011102, 2014 Jul 04.
Article in English | MEDLINE | ID: mdl-25032916

ABSTRACT

We present the results of a search for gravitational waves associated with 223 γ-ray bursts (GRBs) detected by the InterPlanetary Network (IPN) in 2005-2010 during LIGO's fifth and sixth science runs and Virgo's first, second, and third science runs. The IPN satellites provide accurate times of the bursts and sky localizations that vary significantly from degree scale to hundreds of square degrees. We search for both a well-modeled binary coalescence signal, the favored progenitor model for short GRBs, and for generic, unmodeled gravitational wave bursts. Both searches use the event time and sky localization to improve the gravitational wave search sensitivity as compared to corresponding all-time, all-sky searches. We find no evidence of a gravitational wave signal associated with any of the IPN GRBs in the sample, nor do we find evidence for a population of weak gravitational wave signals associated with the GRBs. For all IPN-detected GRBs, for which a sufficient duration of quality gravitational wave data are available, we place lower bounds on the distance to the source in accordance with an optimistic assumption of gravitational wave emission energy of 10(-2)M⊙c(2) at 150 Hz, and find a median of 13 Mpc. For the 27 short-hard GRBs we place 90% confidence exclusion distances to two source models: a binary neutron star coalescence, with a median distance of 12 Mpc, or the coalescence of a neutron star and black hole, with a median distance of 22 Mpc. Finally, we combine this search with previously published results to provide a population statement for GRB searches in first-generation LIGO and Virgo gravitational wave detectors and a resulting examination of prospects for the advanced gravitational wave detectors.

5.
Phys Rev Lett ; 112(13): 131101, 2014 Apr 04.
Article in English | MEDLINE | ID: mdl-24745400

ABSTRACT

Cosmic strings can give rise to a large variety of interesting astrophysical phenomena. Among them, powerful bursts of gravitational waves (GWs) produced by cusps are a promising observational signature. In this Letter we present a search for GWs from cosmic string cusps in data collected by the LIGO and Virgo gravitational wave detectors between 2005 and 2010, with over 625 days of live time. We find no evidence of GW signals from cosmic strings. From this result, we derive new constraints on cosmic string parameters, which complement and improve existing limits from previous searches for a stochastic background of GWs from cosmic microwave background measurements and pulsar timing data. In particular, if the size of loops is given by the gravitational backreaction scale, we place upper limits on the string tension Gµ below 10(-8) in some regions of the cosmic string parameter space.

6.
Rev Sci Instrum ; 82(1): 011301, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21280809

ABSTRACT

In 2000 the first mirror suspensions to use a quasi-monolithic final stage were installed at the GEO600 detector site outside Hannover, pioneering the use of fused silica suspension fibers in long baseline interferometric detectors to reduce suspension thermal noise. Since that time, development of the production methods of fused silica fibers has continued. We present here a review of a novel CO(2) laser-based fiber pulling machine developed for the production of fused silica suspensions for the next generation of interferometric gravitational wave detectors and for use in experiments requiring low thermal noise suspensions. We discuss tolerances, strengths, and thermal noise performance requirements for the next generation of gravitational wave detectors. Measurements made on fibers produced using this machine show a 0.8% variation in vertical stiffness and 0.05% tolerance on length, with average strengths exceeding 4 GPa, and mechanical dissipation which meets the requirements for Advanced LIGO thermal noise performance.

7.
Phys Rev Lett ; 107(27): 271102, 2011 Dec 30.
Article in English | MEDLINE | ID: mdl-22243300

ABSTRACT

The gravitational-wave (GW) sky may include nearby pointlike sources as well as stochastic backgrounds. We perform two directional searches for persistent GWs using data from the LIGO S5 science run: one optimized for pointlike sources and one for arbitrary extended sources. Finding no evidence to support the detection of GWs, we present 90% confidence level (C.L.) upper-limit maps of GW strain power with typical values between 2-20×10(-50) strain(2) Hz(-1) and 5-35×10(-49) strain(2) Hz(-1) sr(-1) for pointlike and extended sources, respectively. The latter result is the first of its kind. We also set 90% C.L. limits on the narrow-band root-mean-square GW strain from interesting targets including Sco X-1, SN 1987A and the Galactic center as low as ≈7×10(-25) in the most sensitive frequency range near 160 Hz.

8.
Nature ; 460(7258): 990-4, 2009 Aug 20.
Article in English | MEDLINE | ID: mdl-19693079

ABSTRACT

A stochastic background of gravitational waves is expected to arise from a superposition of a large number of unresolved gravitational-wave sources of astrophysical and cosmological origin. It should carry unique signatures from the earliest epochs in the evolution of the Universe, inaccessible to standard astrophysical observations. Direct measurements of the amplitude of this background are therefore of fundamental importance for understanding the evolution of the Universe when it was younger than one minute. Here we report limits on the amplitude of the stochastic gravitational-wave background using the data from a two-year science run of the Laser Interferometer Gravitational-wave Observatory (LIGO). Our result constrains the energy density of the stochastic gravitational-wave background normalized by the critical energy density of the Universe, in the frequency band around 100 Hz, to be <6.9 x 10(-6) at 95% confidence. The data rule out models of early Universe evolution with relatively large equation-of-state parameter, as well as cosmic (super)string models with relatively small string tension that are favoured in some string theory models. This search for the stochastic background improves on the indirect limits from Big Bang nucleosynthesis and cosmic microwave background at 100 Hz.

9.
Phys Rev Lett ; 102(11): 111102, 2009 Mar 20.
Article in English | MEDLINE | ID: mdl-19392186

ABSTRACT

We report on an all-sky search with the LIGO detectors for periodic gravitational waves in the frequency range 50-1100 Hz and with the frequency's time derivative in the range -5 x 10{-9}-0 Hz s{-1}. Data from the first eight months of the fifth LIGO science run (S5) have been used in this search, which is based on a semicoherent method (PowerFlux) of summing strain power. Observing no evidence of periodic gravitational radiation, we report 95% confidence-level upper limits on radiation emitted by any unknown isolated rotating neutron stars within the search range. Strain limits below 10{-24} are obtained over a 200-Hz band, and the sensitivity improvement over previous searches increases the spatial volume sampled by an average factor of about 100 over the entire search band. For a neutron star with nominal equatorial ellipticity of 10{-6}, the search is sensitive to distances as great as 500 pc.

10.
Phys Rev Lett ; 101(21): 211102, 2008 Nov 21.
Article in English | MEDLINE | ID: mdl-19113401

ABSTRACT

We present a LIGO search for short-duration gravitational waves (GWs) associated with soft gamma ray repeater (SGR) bursts. This is the first search sensitive to neutron star f modes, usually considered the most efficient GW emitting modes. We find no evidence of GWs associated with any SGR burst in a sample consisting of the 27 Dec. 2004 giant flare from SGR 1806-20 and 190 lesser events from SGR 1806-20 and SGR 1900+14. The unprecedented sensitivity of the detectors allows us to set the most stringent limits on transient GW amplitudes published to date. We find upper limit estimates on the model-dependent isotropic GW emission energies (at a nominal distance of 10 kpc) between 3x10;{45} and 9x10;{52} erg depending on waveform type, detector antenna factors and noise characteristics at the time of the burst. These upper limits are within the theoretically predicted range of some SGR models.

11.
Phys Rev Lett ; 96(23): 231101, 2006 Jun 16.
Article in English | MEDLINE | ID: mdl-16803364

ABSTRACT

In an experiment to simulate the conditions in high optical power advanced gravitational wave detectors, we show for the first time that the time evolution of strong thermal lenses follows the predicted infinite sum of exponentials (approximated by a double exponential), and that such lenses can be compensated using an intracavity compensation plate heated on its cylindrical surface. We show that high finesse approximately 1400 can be achieved in cavities with internal compensation plates, and that mode matching can be maintained. The experiment achieves a wave front distortion similar to that expected for the input test mass substrate in the Advanced Laser Interferometer Gravitational Wave Observatory, and shows that thermal compensation schemes are viable. It is also shown that the measurements allow a direct measurement of substrate optical absorption in the test mass and the compensation plate.

12.
Phys Rev Lett ; 95(22): 221101, 2005 Nov 25.
Article in English | MEDLINE | ID: mdl-16384203

ABSTRACT

The Laser Interferometer Gravitational-Wave Observatory has performed a third science run with much improved sensitivities of all three interferometers. We present an analysis of approximately 200 hours of data acquired during this run, used to search for a stochastic background of gravitational radiation. We place upper bounds on the energy density stored as gravitational radiation for three different spectral power laws. For the flat spectrum, our limit of omega0 < 8.4 x 10(-4) in the 69-156 Hz band is approximately 10(5) times lower than the previous result in this frequency range.

13.
Phys Rev Lett ; 94(18): 181103, 2005 May 13.
Article in English | MEDLINE | ID: mdl-15904354

ABSTRACT

We place direct upper limits on the amplitude of gravitational waves from 28 isolated radio pulsars by a coherent multidetector analysis of the data collected during the second science run of the LIGO interferometric detectors. These are the first direct upper limits for 26 of the 28 pulsars. We use coordinated radio observations for the first time to build radio-guided phase templates for the expected gravitational-wave signals. The unprecedented sensitivity of the detectors allows us to set strain upper limits as low as a few times 10(-24). These strain limits translate into limits on the equatorial ellipticities of the pulsars, which are smaller than 10(-5) for the four closest pulsars.

15.
Phys Rev Lett ; 86(18): 3950-4, 2001 Apr 30.
Article in English | MEDLINE | ID: mdl-11328068

ABSTRACT

TAMA300, an interferometric gravitational-wave detector with 300-m baseline length, has been developed and operated with sufficient sensitivity to detect gravitational-wave events within our galaxy and sufficient stability for observations; the interferometer was operated for over 10 hours stably and continuously. With a strain-equivalent noise level of h approximately 5x10(-21)/sqrt[Hz], a signal-to-noise ratio of 30 is expected for gravitational waves generated by a coalescence of 1.4M-1.4M binary neutron stars at 10 kpc distance. We evaluated the stability of the detector sensitivity with a 2-week data-taking run, collecting 160 hours of data to be analyzed in the search for gravitational waves.


Subject(s)
Astronomy/methods , Gravitation , Astronomy/instrumentation , Lasers , Sensitivity and Specificity
17.
J Bone Joint Surg Br ; 74(1): 111-3, 1992 Jan.
Article in English | MEDLINE | ID: mdl-1732236

ABSTRACT

Four patients with pectoralis major ruptures underwent clinical and dynamometric assessment and one patient underwent late surgical repair. The operation is described. Dynamometry proved a useful and objective method of estimating the loss of strength and indicating patients who might benefit from surgical repair.


Subject(s)
Muscle Contraction , Pectoralis Muscles/injuries , Adult , Humans , Male , Middle Aged , Pectoralis Muscles/physiopathology , Pectoralis Muscles/surgery , Rupture
18.
BMJ ; 302(6791): 1498-501, 1991 Jun 22.
Article in English | MEDLINE | ID: mdl-1855018

ABSTRACT

OBJECTIVE: To determine whether there is any synergistic effect in the administration of intraarticular steroids with distension in the management of early capsulitis of the shoulder. DESIGN: Prospective randomised trial of three treatments--namely distension only, steroid only, and steroid with distension. SETTING: Academic department of orthopaedic and accident surgery at Queen's Medical Centre, Nottingham. SUBJECTS: 47 patients (30 women) with capsulitis affecting 50 shoulders. INTERVENTIONS: Three intra-articular injections into the shoulder given at six week intervals by the same technique. MAIN OUTCOME MEASURES: Passive range of abduction, forward flexion, and external rotation; results of shoulder dynamometry measuring work done and torque produced; pain levels at rest and with resisted movement. RESULTS: All patients reported improvement during the study. Analysis of the mean improvements in abduction and forward flexion showed these to be significantly greater in the steroid with distension and steroid only groups than in the distension only group (mean improvements in abduction (degrees/week (95% confidence interval)) 4.3 (3.4 to 5.2), 3.4 (2.4 to 4.5), and 1.0 (-0.8 to 2.8) in the three groups respectively; mean improvements in flexion (degrees/week (95% confidence interval)) 3.6 (3.2 to 4.0), 3.3 (2.3 to 4.3), and 1.5 (0.5 to 2.5) respectively). Shoulder dynamometry failed to show a significant difference among the treatment groups. No severe complications occurred as a result of the injections, but two patients reported facial flushing related to the use of steroids. CONCLUSION: Intra-articular steroid injections have a useful role in the outpatient management of early capsulitis.


Subject(s)
Insufflation , Shoulder Joint , Triamcinolone Acetonide/administration & dosage , Air , Ambulatory Care , Female , Humans , Injections, Intra-Articular/methods , Joint Diseases/drug therapy , Joint Diseases/therapy , Male , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...