1.
Materials (Basel) ; 16(17)2023 Aug 30.
Article in English | MEDLINE | ID: mdl-37687652

ABSTRACT

An understanding of the biomechanical characteristics and configuration of flexible and locked plating in order to provide balance stability and flexibility of implant fixation will help to construct and promote fast bone healing. The relationship between applied loading and implantation configuration for best bone healing is still under debate. This study aims to investigate the relationship between implant strength, working length, and interfragmentary strain (εIFM) on implant stability for femoral midshaft transverse fractures. The transverse fracture was fixed with a fragment locking compression plate (LCP) system. Finite element analysis was performed and subsequently characterised based on compression loading (600 N up to 900 N) and screw designs (conventional and locking) with different penetration depths (unicortical and bicortical). Strain theory was used to evaluate the stability of the model. The correlation of screw configuration with screw type shows a unicortical depth for both types (p < 0.01) for 700 N and 800 N loads and (p < 0.05) for configurations 134 and 124. Interfragmentary strain affected only the 600 N load (p < 0.01) for the bicortical conventional type (group BC), and the screw configurations that were influenced were 1234 and 123 (p < 0.05). The low steepness of the slope indicates the least εIFM for the corresponding biomechanical characteristic in good-quality stability. A strain value of ≤2% promotes callus formation and is classified as absolute stability, which is the minimum required value for the induction of callus and the maximum value that allows bony bridging. The outcomes have provided the correlation of screw configuration in femoral midshaft transverse fracture implantation which is important to promote essential primary stability.

2.
Materials (Basel) ; 16(13)2023 Jun 21.
Article in English | MEDLINE | ID: mdl-37444827

ABSTRACT

Studies on paediatric spines commonly use human adult or immature porcine spines as specimens, because it is difficult to obtain actual paediatric specimens. There are quite obvious differences, such as geometry, size, bone morphology, and orientation of facet joint for these specimens, compared to paediatric spine. Hence, development of synthetic models that can behave similarly to actual paediatric spines, particularly in term of range of motion (ROM), could provide a significant contribution for paediatric spine research. This study aims to develop a synthetic paediatric spine using finite element modelling and evaluate the reliability of the model by comparing it with the experimental data under certain load conditions. The ROM of the paediatric spine was measured using a validated FE model at ±0.5 Nm moment in order to determine the moment required by the synthetic spine to achieve the same ROM. The results showed that the synthetic spine required two moments, ±2 Nm for lateral-bending and axial rotation, and ±3 Nm for flexion-extension, to obtain the paediatric ROM. The synthetic spine was shown to be stiffer in flexion-extension but more flexible in lateral bending than the paediatric FE model, possibly as a result of the intervertebral disc's simplified shape and the disc's weak bonding with the vertebrae. Nevertheless, the synthetic paediatric spine has promising potential in the future as an alternative paediatric spine model for biomechanical investigation of paediatric cases.

3.
J Healthc Eng ; 2022: 7716821, 2022.
Article in English | MEDLINE | ID: mdl-36275397

ABSTRACT

This study aims to investigate the gait stability response during incline and decline walking for various surface inclination angles in terms of the required coefficient of friction (RCOF), postural stability index (PSI), and center of pressure (COP)-center of mass (COM) distance. A customized platform with different surface inclinations (0°, 5°, 7.5°, and 10°) was designed. Twenty-three male volunteers participated by walking on an inclined platform for each inclination. The process was then repeated for declined platform as well. Qualysis motion capture system was used to capture and collect the trajectories motion of ten reflective markers that attached to the subjects before being exported to a visual three-dimensional (3D) software and executed in Matlab to obtain the RCOF, PSI, as well as dynamic PSI (DPSI) and COP-COM distance parameters. According to the result for incline walking, during initial contact, the RCOF was not affected to inclination. However, it was affected during peak ground reaction force (GRF) starting at 7.5° towards 10° for both walking conditions. The most affected PSI was found at anterior-posterior PSI (APSI) even as low as 5° inclination during both incline and decline walking. On the other hand, DPSI was not affected during both walking conditions. Furthermore, COP-COM distance was most affected during decline walking in anterior-posterior direction. The findings of this research indicate that in order to decrease the risk of falling and manage the inclination demand, a suitable walking strategy and improved safety measures should be applied during slope walking, particularly for decline and anterior-posterior orientations. This study also provides additional understanding on the best incline walking technique for secure and practical incline locomotion.


Subject(s)
Gait , Postural Balance , Male , Humans , Friction , Postural Balance/physiology , Gait/physiology , Walking/physiology , Accidental Falls/prevention & control , Biomechanical Phenomena
4.
Biomed Res Int ; 2022: 5147221, 2022.
Article in English | MEDLINE | ID: mdl-35898687

ABSTRACT

This paper presents a systematic study in reviewing the application of finite element method for the analysis of correction mechanism of spine deformity due to scoliosis. The study is aimed at systematically (1) reviewing the use of finite element analysis in spine deformity case, (2) reviewing the modelling of pedicle screw and rod system in scoliosis surgery, and (3) analysing and discussing gap between the studies. Using the restricted key phrases, the review gathered studies from 2001 to 2021 from various electronic databases (Scopus, ScienceDirect, PubMed, Medline, and WorldCAT). Studies were included if they reported a finite element study on spine deformity. Studies that did not fully disclose their methodology and results had significant discrepancies, not published in English or not yet published were all disqualified. Regardless of inconsistencies in the methodological design of the studies, the quality of all papers was above the acceptable level. A total of fifteen manuscripts were considered for inclusion and were given a comprehensive review. This study indicates that analysing the forces acting on the spine, as well as the interrelationship between the force, stress, and degree of correction (which measured as the Cobb angle), could help to improve the corrective mechanism procedure of spine deformity. Pedicle screws and its placement strategies are also important as it influence the corrective forces for scoliosis treatment. Hence, the findings of this study could potentially be used as a guidance to develop a reliable finite element analysis that can predict the biomechanics responses during the corrective spine deformity treatment.


Subject(s)
Connective Tissue Diseases , Pedicle Screws , Scoliosis , Spinal Fusion , Finite Element Analysis , Humans , Scoliosis/surgery , Spinal Fusion/methods , Spine/surgery
5.
Appl Bionics Biomech ; 2022: 8722333, 2022.
Article in English | MEDLINE | ID: mdl-35096140

ABSTRACT

Osteogenesis Imperfecta (OI) is an inherited disorder characterized by extreme bone fragility due to collagen defects. It is an incurable disease. Bone fractures can occur frequently without prior notice, especially among children. Early quantitative prediction of fracture loads due to OI tends to alert patients to avoid unnecessary situations or dangerous conditions. This study is aimed at investigating the fracture loads of femur with OI under various types of loading. Ten finite element models of an OI-affected bone were reconstructed from the normal femur with different bowing angles ranging from 7.5 to 30.0°. The boundary conditions were assigned on an OI-affected femoral head under three types of load: medial-lateral impacts, compression-tension, and internal-external torsions, and various loading direction cases that reflect the stance condition. The fracture load was examined based on the load that can cause bone fracture for each case. The results show that the loads bearable by the femur before fracture were decreased with respect to the increase of OI bowing angles in most of the loading cases. The risk of fracture for the femur with OI was directly proportional to the increase of bowing angles in the frontal plane. This study provides new insights on fracture load prediction in OI-affected bone with respect to various loading types, which could help medical personnel for surgical intervention judgement.

6.
Acta Bioeng Biomech ; 24(1): 67-74, 2022.
Article in English | MEDLINE | ID: mdl-38314464

ABSTRACT

PURPOSE: The present study aims to investigate the effect of incline and decline walking on ground and joint reaction forces (JRF) of lower extremity and plantar fascia strain (PFS) under certain surface inclination angles. METHODS: Twenty-three male subjects walked on a customized platform with four different surface inclinations (i.e., 0, 5, 7.5 and 10°) with inclined and declined directions. The motion of the ten reflective markers was captured using Qualysis motion capture system (Qualysis, Gothenburg, Sweden) and exported to a visual three-dimensional (3D) software (C-motion, Germantown, USA) in order to analyze the GRF, JRF and PFS. RESULTS: The results found that the peak vertical GRF is almost consistent for 0 and 5° inclination slope but started to decrease at 7.5° onwards during decline walking. The most affected JRF was found on knee at medial-lateral direction even as low as 5 to 10° inclination for both walking conditions. Furthermore, the findings also show that the JRF of lower extremity was more affected during declined walking compared to inclined walking based on the number of significant differences observed in each inclination angle. The PFS was found increased with the increase of surface inclination. CONCLUSIONS: The findings could provide a new insight on the relationship of joint reaction forces and strain parameter in response to the incline and decline walking. It would benefit in providing a better precaution that should be considered during hiking activity, especially in medial-lateral direction in order to prevent injury or fall risk.

7.
Appl Bionics Biomech ; 2021: 2799415, 2021.
Article in English | MEDLINE | ID: mdl-34608402

ABSTRACT

The present study is aimed at investigating the mechanical behaviour of fabricated synthetic midthoracic paediatric spine based on range of motion (ROM) as compared to porcine spine as the biological specimen. The main interest was to ensure that the fabricated synthetic model could mimic the biological specimen behaviour. The synthetic paediatric spine was designed as a 200% scaled-up model to fit into the Bionix Servohydraulic spine simulator. Biomechanical tests were conducted to measure the ROM and nonlinearity of sigmoidal curves at six degrees of freedom (DOF) with moments at ±4 Nm before the specimens failed. Results were compared with the porcine spine (biological specimen). The differences found between the lateral bending and axial rotation of synthetic paediatric spine as compared to the porcine spine were 18% and 3%, respectively, but was still within the range. Flexion extension of the synthetic spine is a bit stiff in comparison of porcine spine with 45% different. The ROM curves of the synthetic paediatric spine exhibited nonlinearities for all motions as the measurements of neutral zone (NZ) and elastic zone (EZ) stiffness were below "1." Therefore, it showed that the proposed synthetic paediatric spine behaved similarly to the biological specimen, particularly on ROM.

8.
Appl Bionics Biomech ; 2021: 8842591, 2021.
Article in English | MEDLINE | ID: mdl-33603827

ABSTRACT

OBJECTIVE: The aim of this study was to investigate the effects of surface stiffness on multisegment foot kinematics and temporal parameters during running. METHODS: Eighteen male subjects ran on three different surfaces (i.e., concrete, artificial grass, and rubber) in both heeled running shoes (HS) and minimal running shoes (MS). Both these shoes had dissimilar sole profiles. The heeled shoes had a higher sole at the heel, a thick base, and arch support, whereas the minimal shoes had a flat base sole. Indeed, the studied biomechanical parameters responded differently in the different footwear during running. Subjects ran in recreational mode speed while 3D foot kinematics (i.e., joint rotation and peak medial longitudinal arch (MLA) angle) were determined using a motion capture system (Qualysis, Gothenburg, Sweden). Information on stance time and plantar fascia strain (PFS) was also collected. RESULTS: Running on different surface stiffness was found to significantly affect the peak MLA angles and stance times for both HS and MS conditions. However, the results showed that the joint rotation angles were not sensitive to surface stiffness. Also, PFS showed no relationship with surface stiffness, as the results were varied as the surface stiffness was changed. CONCLUSION: The surface stiffness significantly contributed towards the effects of peak MLA angle and stance time. These findings may enhance the understanding of biomechanical responses on various running surfaces stiffness in different shoe conditions.

9.
Appl Bionics Biomech ; 2018: 5156348, 2018.
Article in English | MEDLINE | ID: mdl-30116295

ABSTRACT

Various studies have examined body posture stability, including postural sway and associated biomechanical parameters, to assess the severity effects of leg length discrepancy (LLD). However, various viewpoints have been articulated on the results of these studies because of certain drawbacks in the comprehensive analysis of the effect of variations in LLD magnitude. Therefore, this systematic review was performed to help focus on the current findings to help identify which biomechanical parameters are most relevant, commonly used, and able to distinguish and/or have specific clinical relevance to the effect of variations in LLD magnitude during static (standing) and dynamic (walking) conditions. Several electronic databases containing studies from the year 1983 to 2016 (Scopus, ScienceDirect, PubMed, PMC, and ProQuest) were obtained in our literature search. The search process yielded 22 published articles that fulfilled our criteria. We found most of the published data that we analyzed to be inconsistent, and very little data was obtained on the correlation between LLD severity and changes in body posture stability during standing and walking. However, the results of the present review study are in line with previous observational studies, which describe asymmetry in the lower limbs corresponding to biomechanical parameters such as gait kinematics, kinetics, and other parameters described during static (standing) postural balance. In future investigations, we believe that it might be useful to use and exploit other balance-related factors that may potentially influence body posture stability.

10.
J Healthc Eng ; 2018: 7815451, 2018.
Article in English | MEDLINE | ID: mdl-29983905

ABSTRACT

Balance in the human body's movement is generally associated with different synergistic pathologies. The trunk is supported by one's leg most of the time when walking. A person with poor balance may face limitation when performing their physical activities on a daily basis, and they may be more prone to having risk of fall. The ground reaction forces (GRFs), centre of pressure (COP), and centre of mass (COM) in quite standing posture were often measured for the evaluation of balance. Currently, there is still no experimental evidence or study on leg length discrepancy (LLD) during walking. Analysis of the stability parameters is more representative of the functional activity undergone by the person who has a LLD. Therefore, this study hopes to shed new light on the effects of LLD on the dynamic stability associated with VGRF, COP, and COM during walking. Eighteen healthy subjects were selected among the university population with normal BMIs. Each subject was asked to walk with 1.0 to 2.0 ms-1 of walking speed for three to five trials each. Insoles of 0.5 cm thickness were added, and the thickness of the insoles was subsequently raised until 4 cm and placed under the right foot as we simulated LLD. The captured data obtained from a force plate and motion analysis present Peak VGRF (single-leg stance) and WD (double-leg stance) that showed more forces exerted on the short leg rather than long leg. Obviously, changes occurred on the displacement of COM trajectories in the ML and vertical directions as LLD increased at the whole gait cycle. Displacement of COP trajectories demonstrated that more distribution was on the short leg rather than on the long leg. The root mean square (RMS) of COP-COM distance showed, obviously, changes only in ML direction with the value at 3 cm and 3.5 cm. The cutoff value via receiver operating characteristic (ROC) indicates the significant differences starting at the level 2.5 cm up to 4 cm in long and short legs for both AP and ML directions. The present study performed included all the proposed parameters on the effect of dynamic stability on LLD during walking and thus helps to determine and evaluate the balance pattern.


Subject(s)
Gait , Leg Length Inequality/physiopathology , Postural Balance , Walking , Adult , Biomechanical Phenomena , Body Mass Index , Foot/physiology , Foot Orthoses , Humans , Imaging, Three-Dimensional , Male , Posture , ROC Curve , Sensitivity and Specificity , Young Adult
11.
Article in English | MEDLINE | ID: mdl-23581258

ABSTRACT

An assessment of the mechanical properties of trabecular bone is important in determining the fracture risk of human bones. Many uncertainty factors contribute to the dispersion of the estimated mechanical properties of trabecular bone. This study was undertaken in order to propose a computational scheme that will be able to predict the effective apparent elastic moduli of trabecular bone considering the uncertainties that are primarily caused by image-based modelling and trabecular stiffness orientation. The effect of image-based modelling which focused on the connectivity was also investigated. A stochastic multi-scale method using a first-order perturbation-based and asymptotic homogenisation theory was applied to formulate the stochastically apparent elastic properties of trabecular bone. The effective apparent elastic modulus was predicted with the introduction of a coefficient factor to represent the variation of bone characteristics due to inter-individual differences. The mean value of the predicted effective apparent Young's modulus in principal axis was found at approximately 460 MPa for respective 15.24% of bone volume fraction, and this is in good agreement with other experimental results. The proposed method may provide a reference for the reliable evaluation of the prediction of the apparent elastic properties of trabecular bone.


Subject(s)
Apatites/pharmacology , Bone and Bones/physiology , Elastic Modulus , Models, Biological , Uncertainty , Crystallization , Humans , Imaging, Three-Dimensional , Lumbar Vertebrae/drug effects , Lumbar Vertebrae/physiology , Probability , Stochastic Processes
12.
Med Biol Eng Comput ; 50(10): 1091-103, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22948740

ABSTRACT

Trabecular bone has a complicated porous microstructure and consists of interconnected plates and rods known as trabeculae. The microarchitecture of the trabeculae contributes to load distribution capacity and, particularly, the optimal bone strength. Many previous studies have shown that morphological parameters are used to characterize the microarchitecture of trabecular bone, but little is known about the mechanical role of trabecular morphology in the context of load-bearing behavior. Therefore, this study proposes a new segmentation method for examining the morphology of trabecular structure foci of load-bearing capability. A micro-finite element model of trabecular bone was obtained from the fourth lumbar vertebra on the basis of a three-dimensionally reconstructed micro-computed tomography (CT) image. We used an asymptotic homogenization method to determine microscopic stress by applying three unidirectional compressive loads in the vertical, anteroposterior, and right-left axes of two trabecular bone volumes. We then classified the complicated trabecular microstructure into three segments: primary and secondary trabeculae and trabeculae of no contribution. Next, a dynamic analysis was conducted by applying a force impulse load. The result indicated that 1/3 of the trabecular volume functions as primary trabecula. The morphology of the trabecular network could be visualized successfully highlighting the percolation of the stress wave in the primary trabecular segment. Further, we found that the role of the plate-like structures was that of a hub in the trabecular network system.


Subject(s)
Lumbar Vertebrae/anatomy & histology , Models, Biological , Weight-Bearing/physiology , Finite Element Analysis , Humans , Image Processing, Computer-Assisted/methods , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/physiology , Stress, Mechanical , X-Ray Microtomography