J Appl Clin Med Phys ; 24(7): e13970, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37078392

ABSTRACT

PURPOSE: Variability in contouring contributes to large variations in radiation therapy planning and treatment outcomes. The development and testing of tools to automatically detect contouring errors require a source of contours that includes well-understood and realistic errors. The purpose of this work was to develop a simulation algorithm that intentionally injects errors of varying magnitudes into clinically accepted contours and produces realistic contours with different levels of variability. METHODS: We used a dataset of CT scans from 14 prostate cancer patients with clinician-drawn contours of the regions of interest (ROI) of the prostate, bladder, and rectum. Using our newly developed Parametric Delineation Uncertainties Contouring (PDUC) model, we automatically generated alternative, realistic contours. The PDUC model consists of the contrast-based DU generator and a 3D smoothing layer. The DU generator transforms contours (deformation, contraction, and/or expansion) as a function of image contrast. The generated contours undergo 3D smoothing to obtain a realistic look. After model building, the first batch of auto-generated contours was reviewed. Editing feedback from the reviews was then used in a filtering model for the auto-selection of clinically acceptable (minor-editing) DU contours. RESULTS: Overall, C values of 5 and 50 consistently produced high proportions of minor-editing contours across all ROI compared to the other C values (0.936 ± $ \pm \;$ 0.111 and 0.552 ± $ \pm \;$ 0.228, respectively). The model performed best on the bladder, which had the highest proportion of minor-editing contours (0.606) of the three ROI. In addition, the classification AUC for the filtering model across all three ROI is 0.724 ± $ \pm \;$ 0.109. DISCUSSION: The proposed methodology and subsequent results are promising and could have a great impact on treatment planning by generating mathematically simulated alternative structures that are clinically relevant and realistic enough (i.e., similar to clinician-drawn contours) to be used in quality control of radiation therapy.


Subject(s)
Prostatic Neoplasms , Male , Humans , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Tomography, X-Ray Computed/methods , Prostate , Rectum , Urinary Bladder/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods
2.
J Radiol Prot ; 39(3): 825-837, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31226698

ABSTRACT

The dosimetric dependence of ocular structures on eye size and shape was investigated within the standard ICRP Publication 116 irradiation geometries. A realistic transport geometry was constructed by inserting a scalable and deformable stylised eye model developed in our previous study within the head of the ICRP Publication 110 adult male reference computational phantom. Beam irradiations of external electrons, photons, and neutrons on this phantom were simulated using the Monte Carlo radiation transport code PHITS in the geometries of AP, RLAT, PA and ROT. Absorbed doses in ocular structures such as ciliary body, retina, and optic nerves were computed as well as that in lens. A clear dosimetric dependence of ocular structures on eye size and shape was observed for external electrons while only a small dependence was seen for external photons and neutrons. Difference of the tendency was attributed to their depth-dose distributions where spread dose distributions were created by photons and neutrons while more concentrated distributions were created by external electrons.


Subject(s)
Eye/anatomy & histology , Eye/radiation effects , Radiometry/methods , Computer Simulation , Electrons , Humans , Male , Models, Anatomic , Monte Carlo Method , Neutrons , Photons