Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 257
Filter
2.
J Biophotonics ; 16(12): e202300104, 2023 12.
Article in English | MEDLINE | ID: mdl-37556187

ABSTRACT

Optical microscopes can have limited resolution due to aberrations caused by samples and sample holders. Using deformable mirrors and wavefront sensorless optimization algorithms can correct these aberrations, but the correction is limited to a small area of the field of view. This study presents an adaptive optics method that uses a series of plug-and-play deformable lenses for large field of view wavefront correction. A direct wavefront measurement method using the spinning sub-pupil aberration measurement technique is combined with correction based on the deformable lenses. Experimental results using fluorescence microscopy with a wide field and a light sheet fluorescence microscope show that the proposed method can achieve detection and correction over an extended field of view with a compact transmissive module placed in the detection path of the microscope. This method could improve the resolution and accuracy of imaging in a variety of fields, including biology and materials science.


Subject(s)
Lenses , Optics and Photonics , Microscopy/methods
3.
Gynecol Oncol Rep ; 44: 101119, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36568896

ABSTRACT

•Somatic yolk sac tumor differentiation associated with malignant neoplasms is uncommon and associated with poor outcome.•In the gynecologic tract, somatic yolk sac differentiation most often arises in postmenopausal patients.•Somatic yolk sac differentiation shares driver mutations with and likely differentiates from the corresponding carcinoma.•This is the first report of somatic yolk sac differentiation in the gynecologic tract from a non-epithelial malignancy.

4.
NPJ Microgravity ; 8(1): 49, 2022 Nov 02.
Article in English | MEDLINE | ID: mdl-36336703

ABSTRACT

Space-based research can provide a major leap forward in the study of key open questions in the fundamental physics domain. They include the validity of Einstein's Equivalence principle, the origin and the nature of dark matter and dark energy, decoherence and collapse models in quantum mechanics, and the physics of quantum many-body systems. Cold-atom sensors and quantum technologies have drastically changed the approach to precision measurements. Atomic clocks and atom interferometers as well as classical and quantum links can be used to measure tiny variations of the space-time metric, elusive accelerations, and faint forces to test our knowledge of the physical laws ruling the Universe. In space, such instruments can benefit from unique conditions that allow improving both their precision and the signal to be measured. In this paper, we discuss the scientific priorities of a space-based research program in fundamental physics.

5.
Nat Commun ; 13(1): 5052, 2022 Aug 27.
Article in English | MEDLINE | ID: mdl-36030293

ABSTRACT

UV resonance Raman spectroscopy of size-selected linear sp-carbon chains unveils vibrational overtones and combinations up to the fifth order. Thanks to the tunability of the synchrotron source, we excited each H-terminated polyyne (HCnH with n = 8,10,12) to the maxima of its vibronic absorption spectrum allowing us to precisely determine the electronic and vibrational structure of the ground and excited states for the main observed vibrational mode. Selected transitions are shown to enhance specific overtone orders in the Raman spectrum in a specific way that can be explained by a simple analytical model based on Albrecht's theory of resonance Raman scattering. The determined Huang-Rhys factors indicate a strong and size-dependent electron-phonon coupling increasing with the sp-carbon chain length.

7.
Trials ; 23(1): 361, 2022 Apr 27.
Article in English | MEDLINE | ID: mdl-35477480

ABSTRACT

The CLARITY trial (Controlled evaLuation of Angiotensin Receptor Blockers for COVID-19 respIraTorY disease) is a two-arm, multi-centre, randomised controlled trial being run in India and Australia that investigates the effectiveness of angiotensin receptor blockers in addition to standard care compared to placebo (in Indian sites) with standard care in reducing the duration and severity of lung failure in patients with COVID-19. The trial was designed as a Bayesian adaptive sample size trial with regular planned analyses where pre-specified decision rules will be assessed to determine whether the trial should be stopped due to sufficient evidence of treatment effectiveness or futility. Here, we describe the statistical analysis plan for the trial and define the pre-specified decision rules, including those that could lead to the trial being halted. The primary outcome is clinical status on a 7-point ordinal scale adapted from the WHO Clinical Progression scale assessed at day 14. The primary analysis will follow the intention-to-treat principle. A Bayesian adaptive trial design was selected because there is considerable uncertainty about the extent of potential benefit of this treatment.Trial registrationClinicalTrials.gov NCT04394117 . Registered on 19 May 2020Clinical Trial Registry of India CTRI/2020/07/026831Version and revisionsVersion 1.0. No revisions.


Subject(s)
COVID-19 Drug Treatment , Respiratory Tract Diseases , Angiotensin Receptor Antagonists/adverse effects , Bayes Theorem , Data Interpretation, Statistical , Humans , Sample Size
11.
Biomed Opt Express ; 13(1): 262-273, 2022 Jan 01.
Article in English | MEDLINE | ID: mdl-35154869

ABSTRACT

The aberrations induced by the sample and/or by the sample holder limit the resolution of optical microscopes. Wavefront correction can be achieved using a deformable mirror with wavefront sensorless optimization algorithms but, despite the complexity of these systems, the level of correction is often limited to a small area in the field of view of the microscope. In this work, we present a plug and play module for aberration measurement and correction. The wavefront correction is performed through direct wavefront reconstruction using the spinning-pupil aberration measurement and controlling a deformable lens in closed loop. The lens corrects the aberrations in the center of the field of view, leaving residual aberrations at the margins, that are removed by anisoplanatic deconvolution. We present experimental results obtained in fluorescence microscopy, with a wide field and a light sheet fluorescence microscope. These results indicate that detection and correction over the full field of view can be achieved with a compact transmissive module placed in the detection path of the fluorescence microscope.

15.
Phys Rev Lett ; 127(9): 091302, 2021 Aug 27.
Article in English | MEDLINE | ID: mdl-34506170

ABSTRACT

Inflation solves several cosmological problems at the classical and quantum level, with a strong agreement between the theoretical predictions of well-motivated inflationary models and observations. In this Letter, we study the corrections induced by dynamical collapse models, which phenomenologically solve the quantum measurement problem, to the power spectrum of the comoving curvature perturbation during inflation and the radiation-dominated era. We find that the corrections are strongly negligible for the reference values of the collapse parameters.

17.
Phys Rev Lett ; 126(20): 200403, 2021 May 21.
Article in English | MEDLINE | ID: mdl-34110203

ABSTRACT

We present a general master equation describing the quantum dynamics of a scalar bosonic field interacting with an external weak and stochastic gravitational field. The dynamics predicts decoherence both in position and in energy momentum. We show how the master equation reproduces, thus generalizing, the previous results in the literature by taking appropriate limits. We estimate the effect of gravitational decoherence in atom interferometers, providing also a straightforward way to assess the magnitude of the effect.

SELECTION OF CITATIONS
SEARCH DETAIL
...