Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JACC Clin Electrophysiol ; 8(2): 261-274, 2022 02.
Article in English | MEDLINE | ID: mdl-35210090

ABSTRACT

The possibilities of cardiovascular magnetic resonance (CMR) imaging for myocardial tissue characterization and catheter ablation guidance are accompanied by some fictional concepts. In this review, we present the available facts about CMR-guided catheter ablation procedures as well as promising, however unproven, theoretical concepts. CMR promises to visualize the respective arrhythmogenic substrate and may thereby make it more localizable for electrophysiology (EP)-based ablation. Robust CMR imaging is challenged by motion of the heart resulting from cardiac and respiratory cycles. In contrast to conventional "passive" tracking of the catheter tip by real-time CMR, novel approaches based on "active" tracking are performed by integrating microcoils into the catheter tip that send a receiver signal. Several experimental and clinical studies were already performed based on real-time CMR for catheter ablation of atrial and ventricular arrhythmias. Importantly, successful ablation of the cavotricuspid isthmus was already performed in patients with typical atrial flutter. However, a complete EP procedure with real-time CMR-guided transseptal puncture and subsequent pulmonary vein isolation has not been shown so far in patients with atrial fibrillation. Moreover, real-time CMR-guided EP for ventricular tachycardia ablation was only performed in animal models using a transseptal, retrograde, or epicardial access-but not in humans. Essential improvements within the next few years regarding basic technical requirements, such as higher spatial and temporal resolution of real-time CMR imaging as well as clinically approved cardiac magnetic resonance-conditional defibrillators, are ultimately required-but can also be expected-and will move this field forward.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Magnetic Resonance Imaging, Interventional , Radiofrequency Ablation , Animals , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/methods , Humans , Magnetic Resonance Imaging, Interventional/methods , Magnetic Resonance Spectroscopy
2.
Med Mycol Case Rep ; 25: 1-9, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31245269

ABSTRACT

We provide a review of current literature and report on a case of electronic device infective endocarditis with C. tropicalis. A 64-year-old man presented for revision of his implantable cardioverter defibrillator. Echocardiography revealed extensive vegetations attached to the Eustachian valve and in the right ventricular apex. Microbiological findings presented C. tropicalis on the explanted material. The patient refused additional surgical intervention. We successfully treated the patient with liposomal Amphotericin B and Flucytosine for 8 weeks.

SELECTION OF CITATIONS
SEARCH DETAIL
...