Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Cancers (Basel) ; 16(11)2024 May 30.
Article in English | MEDLINE | ID: mdl-38893184

ABSTRACT

In the context of breast cancer treatment optimization, this study prospectively examines the feasibility and outcomes of utilizing intraoperative radiotherapy (IORT) as a boost in combination with standard external beam radiotherapy (EBRT) for high-risk patients. Different guidelines recommend such a tumor bed boost in addition to whole breast irradiation with EBRT for patients with risk factors for local breast cancer recurrence. The TARGIT BQR (NCT01440010) is a prospective, multicenter registry study aimed at ensuring the quality of clinical outcomes. It provides, for the first time, data from a large cohort with a detailed assessment of acute and long-term toxicity following an IORT boost using low-energy X-rays. Inclusion criteria encompassed tumors up to 3.5 cm in size and preoperative indications for a boost. The IORT boost, administered immediately after tumor resection, delivered a single dose of 20 Gy. EBRT and systemic therapy adhered to local tumor board recommendations. Follow-up for toxicity assessment (LENT SOMA criteria: fibrosis, teleangiectasia, retraction, pain, breast edema, lymphedema, hyperpigmentation, ulceration) took place before surgery, 6 weeks to 90 days after EBRT, 6 months after IORT, and then annually using standardized case report forms (CRFs). Between 2011 and 2020, 1133 patients from 10 centers were preoperatively enrolled. The planned IORT boost was conducted in 90%, and EBRT in 97% of cases. Median follow-up was 32 months (range 1-120, 20.4% dropped out), with a median age of 61 years (range 30-90). No acute grade 3 or 4 toxicities were observed. Acute side effects included erythema grade 1 or 2 in 4.4%, palpable seroma in 9.1%, punctured seroma in 0.3%, and wound healing disorders in 2.1%. Overall, chronic teleangiectasia of any grade occurred in 16.2%, fibrosis grade ≥ 2 in 14.3%, pain grade ≥ 2 in 3.4%, and hyperpigmentation in 1.1%. In conclusion, a tumor bed boost through IORT using low-energy X-rays is a swift and feasible method that demonstrates low rates in terms of acute or long-term toxicity profiles in combination with whole breast irradiation.

2.
Breast Care (Basel) ; 16(5): 461-467, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34720805

ABSTRACT

BACKGROUND: Over the last decades, the number of acellular dermal matrix (ADM)-assisted implant-based breast reconstructions (IBBR) has substantially increased. However, there is still a lack of prospective data on complication rates. METHODS: We performed a non-interventional, multicenter, prospective cohort study to evaluate complication rates of a human ADM in patients undergoing an IBBR after skin- and nipple-sparing mastectomies. Patients with primary reconstruction (cohort A) and patients undergoing a secondary reconstruction after capsular fibrosis (cohort B) using the human ADM Epiflex® (DIZG gGmbH, Berlin, Germany) were enrolled in this study. Patients were followed-up for 12 months after surgery. RESULTS: Eighty-four eligible patients were included in this study of whom 28 women underwent a bilateral breast reconstruction, leading to 112 human ADM-assisted reconstructions in total (cohort A: 73, cohort B: 39). In 33.0% of the reconstructed breasts at least one of the complications of primary interest occurred, including implant loss 7.1%, seroma 15.2%; infection 5.4%, rash 8.0%, and Baker grade III/IV capsular fibrosis 2.7%, with no statistically significant differences between the cohorts. Previous radiation therapy was significantly associated with occurrence of any postoperative complication (OR 20.41; p value 0.027). CONCLUSION: The rates of most complications were comparable to the rates reported for other ADMs with relatively low rates of capsular fibrosis and infections. The rate of seroma was increased in our study. Prior radiation therapy increased the risk of any postoperative complications. Therefore, the use of ADM in these patients should be considered carefully.

3.
BMC Cancer ; 7: 178, 2007 Sep 14.
Article in English | MEDLINE | ID: mdl-17854511

ABSTRACT

BACKGROUND: For patients suffering of recurrent breast cancer within the irradiated breast, generally mastectomy is recommended. The normal tissue tolerance does not permit a second full-dose course of radiotherapy to the entire breast after a second breast-conserving surgery (BCS). A novel option is to treat these patients with partial breast irradiation (PBI). This approach is based on the hypothesis that re-irradiation of a limited volume will be effective and result in an acceptable frequency of side effects. The following report presents a single center experience with intraoperative radiotherapy (IORT) during excision of recurrent breast cancer in the previously irradiated breast. METHODS: Between 4/02 and 11/06, 15 patients were treated for in-breast recurrences at a median of 10 years (3-25) after previous EBRT (10 recurrences in the initial tumor bed, 3 elsewhere in-breast failures, 2 invasive recurrences after previous DCIS). Additional 2 patients were selected for IORT with new primary breast cancer after previous partial breast EBRT for treatment of Hodgkin's disease. IORT with a single dose of 14.7 - 20 Gy 50 kV X-rays at the applicator surface was delivered with the Intrabeam-device (Carl Zeiss, Oberkochen, Germany). RESULTS: After a median follow-up of 26 months (1-60), no local recurrence occurred. 14 out of 17 patients are alive and free of disease progression. Two patients are alive with distant metastases. One patient died 26 months after BCS/IORT due to pulmonary metastases diagnosed 19 months after BCS/IORT. Acute toxicity after IORT was mild with no Grade 3/4 toxicities and cosmetic outcome showed excellent/good/fair results in 7/7/3 cases. CONCLUSION: IORT for recurrent breast cancer using low energy X-rays is a valuable option for patients with recurrent breast cancer after previous radiotherapy.


Subject(s)
Breast Neoplasms/radiotherapy , Breast/radiation effects , Carcinoma, Ductal, Breast/radiotherapy , Carcinoma, Intraductal, Noninfiltrating/radiotherapy , Neoplasm Recurrence, Local/radiotherapy , Radiation Injuries/etiology , Aged , Aged, 80 and over , Breast/pathology , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/pathology , Carcinoma, Ductal, Breast/surgery , Carcinoma, Intraductal, Noninfiltrating/pathology , Carcinoma, Intraductal, Noninfiltrating/surgery , Female , Humans , Intraoperative Care , Middle Aged , Neoplasm Recurrence, Local/pathology , Neoplasm Recurrence, Local/surgery , Neoplasm Staging , Patient Selection , Treatment Outcome
4.
Int J Radiat Oncol Biol Phys ; 66(2): 377-81, 2006 Oct 01.
Article in English | MEDLINE | ID: mdl-16887294

ABSTRACT

PURPOSE: Intraoperative radiotherapy (IORT) as a boost for breast cancer delivers a high single dose of radiation to a late-reacting tissue; therefore late toxicity is of particular interest, and long-term follow-up is warranted. To date there are only limited data available on breast cancer patients treated with IORT using low energy X-rays. We analyzed toxicity and cosmesis after IORT as a boost with a minimum follow-up of 18 months. METHODS AND MATERIALS: A total of 73 patients treated with IORT (20 Gy/50 kV X-rays; INTRABEAM [Carl Zeiss Surgical, Oberkochen, Germany]) to the tumor bed during breast-conserving surgery as a boost followed by whole-breast radiotherapy (WBRT, 46 Gy) underwent a prospective, predefined follow-up (median, 25 months; range 18-44 months), including clinical examination and breast ultrasound at 6-months and mammographies at 1-year intervals. Toxicities were documented using the common toxicity criteria (CTC)/European Organization for Research and Treatment of Cancer and the LENT-SOMA score. Cosmesis was evaluated with a score from 1 to 4. RESULTS: The IORT in combination with WBRT was well tolerated, with no Grade 3 or 4 skin toxicities and no telangiectasias. Fibrosis of the entire breast was observed in 5% of the patients. A circumscribed fibrosis around the tumor bed was palpable in up to 27% with a peak around 18 months after therapy and a decline thereafter. The observed toxicitiy rates were not influenced by age, tumor stage, or systemic therapy. The cosmetic outcome was good to excellent in>or=90% of cases. CONCLUSIONS: After IORT of the breast using low-energy X-rays, no unexpected toxicity rates were observed during long-term-follow-up.


Subject(s)
Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Breast/radiation effects , Mastectomy, Segmental , Radiation Injuries/etiology , Adult , Aged , Aged, 80 and over , Breast/pathology , Chemotherapy, Adjuvant , Female , Fibrosis , Humans , Intraoperative Period , Middle Aged , Radiotherapy Dosage , Radiotherapy, Adjuvant/adverse effects
5.
Onkologie ; 29(3): 77-82, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16514267

ABSTRACT

BACKGROUND: We report on acute toxicities as well as the early cosmetic outcome of patients receiving intraoperative radiotherapy (IORT) followed by whole-breast radiotherapy (WBRT) compared to patients treated with standard WBRT alone. PATIENTS AND METHODS: From 2/2002 until 2/2005, 84 breast cancer patients were treated with IORT during breast-conserving surgery (BCS) as a boost (20 Gy/50 kV X-rays) followed by WBRT. After wound healing, all IORT patients were treated with WBRT at a total dose of 46 Gy. For the purpose of comparison, 53 patients treated consecutively between 1/2003 and 12/2004 in our institution with BCS followed by WBRT at a total dose of 50-66 Gy, were analyzed. All patients had a defined followup schedule. Toxicities were prospectively documented using the CTC/EORTC Score. Cosmesis was evaluated after 6 months using a 1-4 score. RESULTS: Treatment was well tolerated with no grade 3/4 acute toxicity. Rare adverse effects following IORT included wound healing problems (2%), erythema grade I-II (3%), palpable seroma (6%) and mastitis (2-4%). The number of patients with induration of the tumor bed was comparably low. CONCLUSION: IORT with the IntrabeamTM system applied as a boost during BCS, followed by 46 Gy WBRT, exerts similar acute toxicity as standard WBRT. Further follow-up is needed to assess long-term toxicity and efficacy.


Subject(s)
Adenocarcinoma/radiotherapy , Adenocarcinoma/surgery , Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Breast/radiation effects , Carcinoma, Ductal/radiotherapy , Carcinoma, Ductal/surgery , Carcinoma, Lobular/radiotherapy , Carcinoma, Lobular/surgery , Intraoperative Care , Mastectomy, Segmental , Radiation Injuries/etiology , Radiotherapy, Adjuvant/instrumentation , Adenocarcinoma/pathology , Adult , Aged , Aged, 80 and over , Breast/pathology , Breast Neoplasms/pathology , Carcinoma, Ductal/pathology , Carcinoma, Lobular/pathology , Combined Modality Therapy , Equipment Design , Esthetics , Female , Follow-Up Studies , Humans , Middle Aged , Neoplasm Staging , Prospective Studies , Radiotherapy Dosage , Whole-Body Irradiation , Wound Healing/radiation effects
6.
Tumori ; 91(4): 339-45, 2005.
Article in English | MEDLINE | ID: mdl-16277101

ABSTRACT

INTRODUCTION: Intraoperative radiotherapy (IORT) with low-energy X-rays (30-50 KV) is an innovative technique that can be used both for accelerated partial breast irradiation (APBI) and intraoperative boosting in patients affected by breast cancer. Immediately after tumor resection the tumor bed can be treated with low-distance X-rays by a single high dose. Whereas often a geographic miss in covering the boost target occurs with external beam boost radiotherapy (EBRT), the purpose of IORT is to cover the tumor bed safely. This report will focus on the feasibility and technical aspects of the Intrabeam device and will summarize our experience with side effects and local control. MATERIALS AND METHODS: Between February 2002 and June 2003 57 breast cancer patients, all eligible for breast conserving surgery (BCS), were treated at the Mannheim Medical Center with IORT using the mobile X-ray system Intrabeam. The patient population in this feasibility study was not homogeneous consisting of 49 patients with primary stage I or II breast cancer, seven with local recurrence after previous EBRT and one with a second primary in a previously irradiated breast. The selection criteria for referral for IORT included tumor size, tumor cavity size, margin status and absence of an extensive intraductal component. The previously irradiated patients with local recurrences and 16 others received IORT as single modality. In all other cases IORT was followed by EBRT with a total dose of 46 Gy in 2-Gy fractions. The intraoperatively delivered dose after tumor resection was 20 Gy prescribed to the applicator surface. EBRT was delivered with a standard two-tangential-field technique using linear accelerators with 6- or 18-MV photons. Patients were assessed every three months by their radiation oncologist or surgeon during the first year after treatment and every six months thereafter. Breast ultrasound for follow-up was done every six months and mammographies once yearly. Acute side effects were scored according to the CTC/EORTC score and late side effects according to the Lent-Soma classification. RESULTS: Twenty-four patients received IORT only; eight patients because they had received previous radiotherapy, 16 because of a very favorable risk profile or their own preference. Thirty-three patients with tumor sizes between 1 and 30 mm and no risk factors were treated by IORT as a boost followed by EBRT. The Intrabeam system was used for IORT. The Intrabeam source produces 30-50 KV X-rays and the prescribed dose is delivered in an isotropic dose distribution around spherical applicators. Treatment time ranged between 20 and 48 minutes. No severe acute side effects or complications were observed during the first postoperative days or after 12 months. One local recurrence occurred 10 months after surgery plus IORT followed by EBRT. In two patients distant metastases were diagnosed shortly after BCS. DISCUSSION: IORT with the Intrabeam system is a feasible method to deliver a single high radiation dose to breast cancer patients. As a preliminary boost it has the advantage of reducing the EBRT course by 1.5 weeks, and as APBI it might be a promising tool for patients with a low risk of recurrence. The treatment is well tolerated and does not cause greater damage than the expected late reaction in normal tissue.


Subject(s)
Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Mastectomy, Segmental , Radiotherapy, Adjuvant/instrumentation , Adult , Aged , Axilla , Breast Neoplasms/pathology , Feasibility Studies , Female , Humans , Intraoperative Care , Lymph Node Excision , Middle Aged , Neoplasm Recurrence, Local/prevention & control , Neoplasm Staging , Neoplasms, Second Primary/radiotherapy , Neoplasms, Second Primary/surgery , Patient Selection , Radiotherapy Dosage , Radiotherapy, Adjuvant/adverse effects , Retrospective Studies , Treatment Outcome
7.
Eur J Obstet Gynecol Reprod Biol ; 122(2): 162-6, 2005 Oct 01.
Article in English | MEDLINE | ID: mdl-16219516

ABSTRACT

OBJECTIVE: We performed a survey among German obstetricians and gynecologists in order to evaluate the influence of biographic data, working environment and personal birth experience on the attitude towards Cesarean Section on demand. MATERIAL AND METHODS: All 2106 board-certified gynecologists in Baden-Württemberg received an anonymous questionnaire in 2002-2003 concerning attitude towards C-section on demand, biographical data, personal birth experience and working environment. Seven hundred and nineteen questionnaires were returned and entered into statistical analysis. RESULTS: General approval of C-section was in 59% of all participants, with huge statistically significant variations according to age, personal birth experience and working field. When asked for their preferred way of delivery for themselves or their partner after a low-risk pregnancy, 90% of the responding gynecologists opted for vaginal delivery. The approval depended statistically significant on parenthood, personal birth experience and working environment. CONCLUSIONS: Biographical data, personal birth experience and working environment influence the attitude towards elective Cesaran section. Although 90% would chose vaginal delivery for themselves or their partner as best medical practice, 59% of the physicians approve of the general opportunity of C-section on demand. This shows, that not only best medical practice, but also patient autonomy and forensic aspects seem to play an important role.


Subject(s)
Attitude of Health Personnel , Cesarean Section/statistics & numerical data , Gynecology , Obstetrics , Patient Satisfaction , Female , Germany , Health Care Surveys , Humans , Male , Parturition , Physicians/psychology , Pregnancy , Professional Practice
8.
Arch Gynecol Obstet ; 270(1): 6-9, 2004 Jul.
Article in English | MEDLINE | ID: mdl-12955529

ABSTRACT

INTRODUCTION: The risk of infectious complications after water birth which might be due to water contaminated by faecal bacteria or environmental microbes from the water supply system is still in discussion. MATERIALS AND METHODS: We performed a microbiological study comparing neonatal bacterial colonisation after water birth to conventional bed deliveries with or without relaxation bath. In all three groups (96 deliveries) we isolated most frequently from ear and palate of the newborns Staphylococcus epidermidis, E. coli and enterococci, which belong to the normal vaginal flora. RESULTS: Neonatal outcome, infants and maternal infection rate did not differ between the three groups.


Subject(s)
Baths , Delivery, Obstetric/methods , Infant, Newborn, Diseases/epidemiology , Infant, Newborn, Diseases/microbiology , Water Microbiology , Ear/microbiology , Enterococcus/isolation & purification , Escherichia coli/isolation & purification , Female , Germany/epidemiology , Humans , Infant, Newborn , Mouth/microbiology , Pregnancy , Pregnancy Outcome , Prospective Studies , Staphylococcus epidermidis/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL
...