2.
JACC Cardiovasc Interv ; 16(24): 3016-3023, 2023 Dec 25.
Article in English | MEDLINE | ID: mdl-37902144

ABSTRACT

BACKGROUND: The SavvyWire (OpSens Inc) is a 0.035-inch preshaped guidewire with dedicated pacing properties and a distal pressure sensor allowing for continuous hemodynamic pressure monitoring. OBJECTIVES: This study sought to determine the efficacy and safety of the guidewire during transcatheter aortic valve replacement (TAVR) procedures. METHODS: This prospective, multicenter clinical study included patients with severe aortic stenosis undergoing TAVR in 8 European centers. The primary efficacy endpoint was defined as effective left ventricular rapid pacing runs with the guidewire translating into a significant systemic pressure drop (below 60 mm Hg). The safety outcome included the absence of major procedural complications related to the guidewire. RESULTS: A total of 121 patients (mean age: 82.2 ± 5.9 years, 50% women) were included in the study, and 119 (98.3%) patients were finally treated with the study device. A balloon-expandable valve was implanted in 45 (37.8%) patients. Predilatation and postdilatation were performed in 89 (74.8%) and 14 (11.8%) patients, respectively. The primary efficacy endpoint was achieved in 116 (98.3%) patients, and the mean aortic systolic arterial pressure achieved during rapid pacing was 46.6 ± 11.3 mm Hg. Hemodynamic assessment with the use of the OptoMonitor 3 (OpSens Inc) without additional catheter exchange was achieved in 117 (99.2%) patients. The safety endpoint was achieved in 117 (99.2%) patients. No procedural mortality, stroke, or ventricular perforation was reported. CONCLUSIONS: The use of the guidewire during TAVR procedures appeared to be efficacious and safe. This device could help minimize interventions during the procedure and improve the clinical decision making after transcatheter heart valve deployment. (SavvyWire Efficacy and Safety in Transcatheter Aortic Valve Implantation Procedures [SAFE-TAVI]; NCT05492383).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prospective Studies , Treatment Outcome
3.
Bioengineering (Basel) ; 10(10)2023 Oct 16.
Article in English | MEDLINE | ID: mdl-37892936

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is a procedure to treat severe aortic stenosis. There are several clinical concerns related to potential complications after the procedure, which demand the analysis of computerized tomography (CT) scans after TAVI to assess the implant's result. This work introduces a novel, fully automatic method for the analysis of post-TAVI 4D-CT scans to characterize the prosthesis and its relationship with the patient's anatomy. The method enables measurement extraction, including prosthesis volume, center of mass, cross-sectional area (CSA) along the prosthesis axis, and CSA difference between the aortic root and prosthesis, all the variables studied throughout the cardiac cycle. The method has been implemented and evaluated with a cohort of 13 patients with five different prosthesis models, successfully extracting all the measurements from each patient in an automatic way. For Allegra patients, the mean of the obtained inner volume values ranged from 10,798.20 mm3 to 18,172.35 mm3, and CSA in the maximum diameter plane varied from 396.35 mm2 to 485.34 mm2. The implantation of this new method could provide information of the important clinical value that would contribute to the improvement of TAVI, significantly reducing the time and effort invested by clinicians in the image interpretation process.

4.
Rev Esp Cardiol (Engl Ed) ; 76(12): 1021-1031, 2023 Dec.
Article in English, Spanish | MEDLINE | ID: mdl-37863184

ABSTRACT

INTRODUCTION AND OBJECTIVES: This article presents the annual activity report of the Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC) for the year 2022. METHODS: All Spanish centers with catheterization laboratories were invited to participate. Data were collected online and were analyzed by an external company in collaboration with the members of the board of the ACI-SEC. RESULTS: A total of 111 centers participated. The number of diagnostic studies increased by 4.8% compared with 2021, while that of percutaneous coronary interventions (PCI) remained stable. PCIs on the left main coronary artery increased by 22%. The radial approach continued to be preferred for PCI (94.9%). There was an upsurge in the use of drug-eluting balloons, as well as in intracoronary imaging techniques, which were used in 14.7% of PCIs. The use of pressure wires also increased (6.3% vs 2021) as did plaque modification techniques. Primary PCI continued to grow and was the most frequent treatment (97%) in ST-segment elevation myocardial infarction. Most noncoronary procedures maintained their upward trend, particularly percutaneous aortic valve implantation, atrial appendage closure, mitral/tricuspid edge-to-edge therapy, renal denervation, and percutaneous treatment of pulmonary arterial disease. CONCLUSIONS: The Spanish cardiac catheterization and coronary intervention registry for 2022 reveals a rise in the complexity of coronary disease, along with a notable growth in procedures for valvular and nonvalvular structural heart disease.


Subject(s)
Cardiology , Coronary Artery Disease , Percutaneous Coronary Intervention , Humans , Cardiac Catheterization , Registries
5.
J Clin Med ; 12(12)2023 Jun 18.
Article in English | MEDLINE | ID: mdl-37373808

ABSTRACT

BACKGROUND: The timing and selection of optimal candidates for mitral transcatheter edge-to-edge valve repair remains to be fully determined, especially in cases with severely depressed left ventricular ejection fraction (LVEF). The objective of this study is to evaluate the prognostic value of myocardial strain (LVGLS) in this setting. METHODS: Retrospectively, 172 consecutive patients with LVEF ≤40% and severe MR treated with MitraClip were included. Four groups were generated according to the LVEF (<30% or ≥30%) and median LVGLS. The primary end-point was cardiovascular mortality. RESULTS: Procedural success was high (96.5%) and complications were rare. At one-year follow-up, 82.5% of patients maintained MR grade ≤2, 79.2% were at a NYHA class ≤II and a reduction of 80% in heart failure admissions was observed in all groups. Interestingly, among patients with a more depressed LVEF, LVGLS was found to be an independent predictor for cardiovascular mortality (HR: 3.3; 95% CI: 1.1-10, p = 0.023). CONCLUSIONS: Mitral valve repair with MitraClip is safe and it improves the mid-term functional class of patients regardless of LVEF. LVGLS can help in the selection of optimal candidates and timing for this procedure, as well as in the recognition of those patients with worse prognoses.

6.
EuroIntervention ; 19(5): e442-e449, 2023 Aug 07.
Article in English | MEDLINE | ID: mdl-37128805

ABSTRACT

BACKGROUND: Data regarding the safety and long-term effectiveness of percutaneous closure of paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI) are scarce. AIMS: This study aims to present a large multicentre international experience of percutaneous post-TAVI PVL closure. METHODS: All patients who underwent percutaneous post-TAVI PVL closure in 14 hospitals across Europe and North America between January 2018 and October 2022 were included. RESULTS: Overall, 45 patients (64% male) were enrolled. The median age was 80 years (75-84). Among them, 67% and 33% had self-expanding and balloon-expandable valve implantations, respectively. Baseline post-TAVI PVL was severe in 67% of cases and moderate in the rest. The time from index TAVI to PVL closure procedure was 16.1 (8.7-34.8) months. Most patients were in NYHA Class III and IV (73%) before the procedure, and 40% had referred hospitalisations for heart failure between TAVI and the PVL closure procedure. Successful PVL closure was achieved in 94%, reducing regurgitation to ≤mild in 91% and moderate in the rest. The Amplatzer Valvular Plug III was the most frequently used device (27 cases), followed by the Amplatzer Valvular Plug 4. The incidence of severe adverse events was 11%. None of the patients died during the index hospitalisation. During long-term follow-up (21.7±16.2 months), the all-cause mortality rate was 14%, and patients presented improvement in functional status and a significant reduction in the rate of hospitalisation for heart failure (from 40% to 6%). CONCLUSIONS: Percutaneous PVL closure is a feasible and safe option for treating post-TAVI leaks. Successful PVL reduction to mild or less could be associated with acute and long-lasting improvements in clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged, 80 and over , Female , Transcatheter Aortic Valve Replacement/adverse effects , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Heart Valve Prosthesis Implantation/methods , Registries , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery
7.
JACC Cardiovasc Interv ; 16(10): 1208-1217, 2023 05 22.
Article in English | MEDLINE | ID: mdl-37225292

ABSTRACT

BACKGROUND: Coronary obstruction (CO) following transcatheter aortic valve replacement (TAVR) is a life-threatening complication, scarcely studied. OBJECTIVES: The authors analyzed the incidence of CO after TAVR, presentation, management, and in-hospital and 1-year clinical outcomes in a large series of patients undergoing TAVR. METHODS: Patients from the Spanish TAVI (Transcatheter Aortic Valve Implantation) registry who presented with CO in the procedure, during hospitalization or at follow-up were included. Computed tomography (CT) risk factors were assessed. In-hospital, 30-day, and 1-year all-cause mortality rates were analyzed and compared with patients without CO using logistic regression models in the overall cohort and in a propensity score-matched cohort. RESULTS: Of 13,675 patients undergoing TAVR, 115 (0.80%) presented with a CO, mainly during the procedure (83.5%). The incidence of CO was stable throughout the study period (2009-2021), with a median annual rate of 0.8% (range 0.3%-1.3%). Preimplantation CT scans were available in 105 patients (91.3%). A combination of at least 2 CT-based risk factors was less frequent in native than in valve-in-valve patients (31.7% vs 78.3%; P < 0.01). Percutaneous coronary intervention was the treatment of choice in 100 patients (86.9%), with a technical success of 78.0%. In-hospital, 30-day, and 1-year mortality rates were higher in CO patients than in those without CO (37.4% vs 4.1%, 38.3% vs 4.3%, and 39.1% vs 9.1%, respectively; P < 0.001). CONCLUSIONS: In this large, nationwide TAVR registry, CO was a rare, but often fatal, complication that did not decrease over time. The lack of identifiable predisposing factors in a subset of patients and the frequently challenging treatment when established may partly explain these findings.


Subject(s)
Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Catheters , Registries
8.
Rev Esp Cardiol (Engl Ed) ; 76(1): 25-31, 2023 Jan.
Article in English, Spanish | MEDLINE | ID: mdl-35691867

ABSTRACT

INTRODUCTION AND OBJECTIVES: The PASCAL system is a novel device for transcatheter mitral valve repair based on the edge-to-edge concept. The unique features of this device might have a relevant impact on the repair outcomes. There are few data on clinical outcomes in real-life registries. The aim of this study was to report the early Iberian experience (Spain and Portugal) of the PASCAL system. METHODS: Procedural and 30-day outcomes were investigated in consecutive patients with symptomatic severe mitral regurgitation (MR) treated with the PASCAL system at 10 centers. Primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE) at 30 days. RESULTS: We included 68 patients (age, 75 [68-81] years; 38% women; EuroSCORE II 4.5%). MR etiology was degenerative in 25%, functional in 65%, and mixed in 10%. A total of 71% of patients were in New York Heart Association (NYHA) functional class≥III. Technical success was achieved in 96% and independent capture was used in 73% of procedures. In the treated population, MR at discharge was≤2+ in 100%, with no in-hospital deaths. At 30 days, the MAE rate was 5.9%, the all-cause mortality rate was 1.6%, 98% were in NYHA functional class≤II, and 95% had MR≤2+ (P<.001). CONCLUSIONS: Transcatheter mitral valve repair with the PASCAL system was safe and effective, with high procedural success and low rates of MAE. At 30 days, MR was significantly reduced, with a significant improvement in functional status.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Female , Aged , Male , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization/adverse effects , Treatment Outcome
11.
Rev Esp Cardiol (Engl Ed) ; 75(10): 797-804, 2022 Oct.
Article in English, Spanish | MEDLINE | ID: mdl-35288060

ABSTRACT

INTRODUCTION AND OBJECTIVES: In patients with tricuspid regurgitation (TR), edge-to-edge transcatheter tricuspid valve repair (TTVR) is the strategy with the highest penetration worldwide. A dedicated edge-to-edge TTVR system has recently become available in Europe. The present study describes the initial experience with the system in Spain. METHODS: This multicenter study collected individual data from the centers accepted for the use of the novel system within an initial limited release. Between June 2020 and March 2021, all patients undergoing an edge-to-edge TTVR using the TriClip system in Spain were included in the study. The primary endpoint was the achievement of a TR reduction of at least 1 grade at discharge. RESULTS: We included 34 patients. Most of them reported a previous history of atrial fibrillation (91%) and only 1 had a pacemaker lead. The primary endpoint (TR reduction of at least 1 grade at discharge) was met in all patients. Most of the patients required 1 (47%) or 2 clips (44%) with a clear predominance of XT (87%) over NT (13%). The location of the first clip was anteroseptal in >90% of the patients. Only 1 patient had a partial detachment, which was stabilized with additional clips in the same procedure. At discharge, TR severity was≤2 in 91% of patients. At 3 months, mortality was nil. Overall, 88% of patients were in New York Heart Association functional class≤2 and 80% had residual TR≤2. CONCLUSIONS: Edge-to-edge TTVR seemed to be effective and safe with a sustained TR reduction at 3 months. Further studies will be needed to confirm our findings.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Humans , Severity of Illness Index , Time Factors , Treatment Outcome , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/surgery
12.
Rev Esp Cardiol (Engl Ed) ; 75(12): 1001-1010, 2022 Dec.
Article in English, Spanish | MEDLINE | ID: mdl-35272968

ABSTRACT

INTRODUCTION AND OBJECTIVES: Transcatheter edge-to-edge repair (TEER) should be considered in patients with heart failure and secondary mitral regurgitation (MR). Angiotensin receptor-neprilysin inhibitors (ARNIs) have been demonstrated to improve prognosis in heart failure. We aimed to evaluate the impact ARNIs on patient selection and outcomes. METHODS: The population of the Spanish TEER prospective registry (March 2012 to January 2021) was divided into 2 groups: a) TEER before the ARNI era (n=450) and b) TEER after the recommendation of ARNIs by European Guidelines (n=639), with further analysis according to intake (n=52) or not (n=587) of ARNIs. RESULTS: A total of 1089 consecutive patients underwent TEER for secondary MR. In the ARNI era, there was a reduction in left ventricle dilation (82mL vs 100mL, P=.025), and better function (35% vs 38%, P=.011). At 2 years of follow-up, mortality (10.6% vs 17.3%, P <.001) and heart failure readmissions (16.6% vs 27.8%, P <.001) were lower in the ARNI era, but not recurrent MR. In the ARNI era, 1- and 2-year mortality were similar irrespective of ARNI intake but patients on ARNIs had a lower risk of readmission+mortality at 2 years (OR, 0.369; 95%CI, 0.137-0.992; P=.048), better NYHA class, and lower recurrence of MR III-IV (1.9% vs 14.3%, P=.011). CONCLUSIONS: Better patient selection for TEER has been achieved in the last few years with a parallel improvement in outcomes. The use of ARNIs was associated with a significant reduction in overall events, better NYHA class, and lower MR recurrence.


Subject(s)
Heart Failure , Mitral Valve Insufficiency , Neprilysin , Humans , Heart Failure/drug therapy , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/drug therapy , Mitral Valve Insufficiency/surgery , Neprilysin/antagonists & inhibitors , Receptors, Angiotensin , Treatment Outcome
13.
Diagnostics (Basel) ; 12(2)2022 Jan 27.
Article in English | MEDLINE | ID: mdl-35204425

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has become the treatment of choice for patients with severe aortic stenosis and high surgical risk. Angiography has been established as an essential tool in TAVI, as this modality provides real-time images required to support the intervention. The automatic interpretation and parameter extraction on such images can lead to significative improvements and new applications in the procedure that, in most cases, rely on a prior identification of the transcatheter heart valve (THV). In this paper, U-Net architecture is proposed for the automatic segmentation of THV on angiographies, studying the role of its hyperparameters in the quality of the segmentations. Several experiments have been conducted, testing the methodology using multiple configurations and evaluating the results on different types of frames captured during the procedure. The evaluation has been performed in terms of conventional classification metrics, complemented with two new metrics, specifically defined for this problem. Those new metrics provide a more appropriate assessment of the quality of the results, given the class imbalance in the dataset. From an analysis of the evaluation results, it can be concluded that the method provides appropriate segmentation results for this dataset.

15.
Rev Esp Cardiol (Engl Ed) ; 75(6): 479-487, 2022 Jun.
Article in English, Spanish | MEDLINE | ID: mdl-34711513

ABSTRACT

INTRODUCTION AND OBJECTIVES: Transaxillary access (TXA) has become the most widely used alternative to transfemoral access (TFA) in patients undergoing transcatheter aortic valve implantation (TAVI). The aim of this study was to compare total in-hospital and 30-day mortality in patients included in the Spanish TAVI registry who were treated by TXA or TFA access. METHODS: We analyzed data from patients treated with TXA or TFA and who were included in the TAVI Spanish registry. In-hospital and 30-day events were defined according to the recommendations of the Valve Academic Research Consortium. The impact of the access route was evaluated by propensity score matching according to clinical and echocardiogram characteristics. RESULTS: A total of 6603 patients were included; 191 (2.9%) were treated via TXA and 6412 via TFA access. After adjustment (n=113 TXA group and n=3035 TFA group) device success was similar between the 2 groups (94%, TXA vs 95%, TFA; P=.95). However, compared with the TFA group, the TXA group showed a higher rate of acute myocardial infarction (OR, 5.3; 95%CI, 2.0-13.8); P=.001), renal complications (OR, 2.3; 95%CI, 1.3-4.1; P=.003), and pacemaker implantation (OR, 1.6; 95%CI, 1.01-2.6; P=.03). The TXA group also had higher in-hospital and 30-day mortality rates (OR, 2.2; 95%CI, 1.04-4.6; P=.039 and OR, 2.3; 95%CI, 1.2-4.5; P=.01, respectively). CONCLUSIONS: Compared with ATF, TXA is associated with higher total mortality, both in-hospital and at 30 days. Given these results, we believe that TXA should be considered only in those patients who are not suitable candidates for TFA.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Humans , Propensity Score , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
16.
Int J Cardiol ; 345: 29-35, 2021 Dec 15.
Article in English | MEDLINE | ID: mdl-34610357

ABSTRACT

BACKGROUND: Isolated atrial fibrillation can cause mitral regurgitation (MR) in patients with normal left ventricular systolic function and no organic disease of the mitral valve. Little information is available regarding outcomes of Mitraclip in patients with atrial functional mitral regurgitation (AFMR). We aimed to evaluate 12-month clinical and echocardiographic outcomes of transcatheter mitral valve repair (TMVR) with MitraClip in patients with AFMR compared to those with ventricular functional or degenerative/mixed MR. METHODS: Registry-based analysis of all consecutive patients who underwent TMVR and were included in the Spanish Registry of Mitraclip. Changes in MR and NYHA functional class, and a combined endpoint including all-cause mortality and hospitalizations due to heart failure were the main outcomes. RESULTS: Overall, 1074 (69.1% male, 73.3 ± 10.2 years-old) patients were analyzed in this report. 48 patients (4.5%) presented AFMR. AFMR was significantly reduced after TMVR, with a procedural success rate of 91.7%, and this reduction persisted at 12-month (p < 0.001). Patients with AFMR showed a significant functional improvement at 6- and 12-month follow-up in our series (baseline: NYHA III 70.8% IV 18.8% vs. 1-year: NYHA III 21.7% IV 0%; p < 0.001). The probability of survival free of readmission for heart failure and all-cause mortality within the first year after TMVR was 74.9%. Procedural and clinical outcomes, as well as recurrent rates of MR were similar acutely and at 1-year compared to other etiologies. CONCLUSION: TMVR in patients with AFMR showed no significant differences compared to ventricular functional or degenerative/mixed MR regarding MR reduction or clinical outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged , Aged, 80 and over , Cardiac Catheterization , Echocardiography , Female , Heart Atria , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome
17.
Catheter Cardiovasc Interv ; 98(6): 1204-1209, 2021 11 15.
Article in English | MEDLINE | ID: mdl-34137483

ABSTRACT

OBJECTIVES: We aimed to determine the safety and efficacy of the Allegra transcatheter heart valve (THV) for the treatment of severe aortic valve stenosis in a large patient population treated under real-world conditions. BACKGROUND: The Allegra is a novel self-expanding THV with supra-annular bovine leaflets. The valve is available in three different sizes (23, 27, and 31 mm), all are delivered through an 18F sheath. METHODS: Consecutive patients undergoing TAVR with the Allegra THV were enrolled in a multicenter-registry. Data were collected throughout initial hospital-stay and at 30-day follow-up. Clinical endpoints were defined according to the updated definitions of the Valve-Academic-Research-Consortium. RESULTS: This registry included 255 patients (mean age 83 ± 6 years, 48% women) from four European centers. Median European System for Cardiac Operative Risk Evaluation II score (EuroSCORE II) was 3.3% (IQR 1.9-5.8%). Acute device success was 95.7%. The remaining 11 patients had either moderate paravalvular regurgitation immediately after the procedure (7 patients) or the device could not be optimal positioned requiring implantation of a second THV (4 patients). Major vascular complications and major/life-threatening bleedings occurred in 10 (3.9%) and 12 (4.7%) patients, respectively. At 30 day follow-up, mean effective orifice area was 2.2 ± 0.5 cm2 , mean gradient was 6.9 ± 3.8 mmHg, 7 (3.3%) patients had more than mild paravalvular leakage, 3 patients (1.2%) had died, 6 patients (2.4%) had a stroke and 30 (12.8%) patients had required implantation of a new permanent pacemaker. CONCLUSIONS: Transfemoral implantation of the Allegra THV resulted in favorable clinical and echocardiographic outcomes during hospitalization and short-term follow up.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Animals , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cattle , Female , Humans , Male , Prosthesis Design , Registries , Risk Factors , Terfenadine/analogs & derivatives , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
18.
Catheter Cardiovasc Interv ; 98(2): 365-370, 2021 08 01.
Article in English | MEDLINE | ID: mdl-33890713

ABSTRACT

OBJECTIVES: The objective was to evaluate the results of valve-in-valve procedures performed with the Allegra device. BACKGROUND: Transcatheter aortic valve implantation to treat degenerated biological aortic valves (valve-in-valve) is an established procedure in most catheterization laboratories, but the results are poorer than procedures done in native aortic stenosis. The Allegra device (Biosensors, Morges, Switzerland) has an excellent design to treat these patients. METHODS: All patients with severely degenerated biological aortic valve treated with the Allegra device in centers from Spain until December 2020 were included (n = 29). Hemodynamic results and 30-day clinical outcomes were evaluated. The predominant hemodynamic failure was stenosis in 15, regurgitation in 11, and a combination of both in 3 cases. Time from aortic valve replacement to valve-in-valve procedure was 8.4 ± 3.9 years (range 3.3-22.1). RESULTS: After the procedure, maximum and mean trans-valvular gradients were 17.4 ± 12.3 and 8.4 ± 6.1 mmHg, respectively. Device success was obtained in 28 patients (96.6%). In one patient with a degenerated 19 mm prosthetic valve, mean gradient after the procedure was 22 mmHg. No patients had a para-valvular leak grade >1. There were no deaths during the hospitalization or at 30 days and one patient suffered a stroke. CONCLUSIONS: The Allegra trans-catheter aortic valve offers optimal hemodynamic results in patients with severely degenerated biological aortic valve.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Catheters , Heart Valve Prosthesis Implantation/adverse effects , Humans , Prosthesis Design , Registries , Terfenadine/analogs & derivatives , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
J Clin Med ; 10(4)2021 Feb 12.
Article in English | MEDLINE | ID: mdl-33673247

ABSTRACT

BACKGROUND AND AIM: Recent randomized data comparing percutaneous mitral valve repair (PMVR) versus optimal medical treatment in patients with functional MR (FMR) seemed to highlight the importance of the learning curve not only for procedural outcomes but also for patient selection. The aim of the study was to compare a contemporary series of patients undergoing PMVR using a second-generation Mitraclip device (Mitraclip NT) with previous cohorts treated with a first-generation system. METHODS: This multicenter study collected individual data from 18 centers between 2012 and 2017. The cohort was divided into three groups according to the use of the first-generation Mitraclip during the first (control-1) or second half (control-2) or the Mitraclip NT system. RESULTS: A total of 545 consecutive patients were included in the study. Among all, 182 (33.3%), 183 (33.3%), and 180 (33.3%) patients underwent mitral repair in the control-1, control-2, and NT cohorts, respectively. Procedural success was achieved in 93.3% of patients without differences between groups. Major adverse events did not statistically differ among groups, but there was a higher rate of pericardial effusion in the control-1 group (4.3%, 0.6%, and 2.6%, respectively; p = 0.025). The composite endpoint of death, surgery, and admission for congestive heart failure (CHF) at 12 months was lower in the NT group (23.5% in control-1, 22.5% in control-2, and 8.3% in the NT group; p = 0.032). CONCLUSIONS: The present paper shows that contemporary clinical outcomes of patients undergoing PMVR with the Mitraclip system have improved over time.

20.
Comput Methods Biomech Biomed Engin ; 24(14): 1629-1637, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33779444

ABSTRACT

Trans-catheter aortic valve implantation (TAVI) is an increasingly adopted technique which provides a minimal invasive solution for patients who suffer from severe aortic stenosis. Some complications of the procedure could be annular rupture or paravalvular leakage, both related with adverse outcome. In TAVI with balloon expandable devices, a mismatch between those two factors leads to a conflict situation, where improving one worsens the other. The presented research proposes a methodology that uses numerical simulation to obtain certain TAVI outcomes related with aortic regurgitation due to paravalvular leakage, such as perivalvular area, aortic eccentricity or annular pressure. The application of the methodology for two patients shows the possibility of predicting those quantities. The highest stress values are distributed along the contact area. Results also show that a great deformation on the aortic annulus does not necessarily imply a higher stress; pressure can either be converted into root reshape or into root stretching. Validation of the results was done using scientific publications, clinical guidelines and clinical reports. Numerical simulation provides a suitable tool that could possibly contribute to optimize the planification procedure adjusting the mismatch between size and pressure.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Treatment Outcome