Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
1.
Bone Rep ; 21: 101759, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38590391

ABSTRACT

Patients with Crohn's disease are at increased risk for symptomatic nephrolithiasis. Stones in these patients are most commonly composed of calcium oxalate monohydrate or mixed calcium-oxalate and calcium-phosphate. Precipitation of both minerals depends on urinary pH, calcium, phosphate and oxalate excretion. The present manuscript reports on two patients with Crohn's disease and bowel resection, in whom the onset of symptomatic urolithiasis occurred after repeated infusions of ferric carboxymaltose - a drug, which is known to cause hyperphosphaturia. The present study shows that ferric carboxymaltose-induced hyperphosphaturia can be associated with kidney stone formation and symptomatic urolithiasis, especially in patients treated with calcitriol. Calcitriol has been shown to mitigate ferric carboxymaltose-induced secondary hyperparathyroidism and hyperphosphaturia, but is known to increase urinary calcium excretion. Chemical analysis of recovered stones revealed that they were mixed calcium oxalate and phosphate stones. Ring-like deposition of iron detected by spatially resolved elemental analysis using laser ablation-inductively coupled plasma mass spectrometry, showed that the stones also contained iron. Based on our findings, we propose that patients with inflammatory bowel disease requiring intravenous iron therapy should be carefully monitored for the development of hypophosphatemia and urolithiasis. If hypophosphatemia occurs in such patients, calcitriol should be used with caution.

2.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38059765

ABSTRACT

The development of a sample environment for in situ x-ray characterization during metal Electron Beam Powder Bed Fusion (PBF-EB), called MiniMelt, is presented. The design considerations, the features of the equipment, and its implementation at the synchrotron facility PETRA III at Deutsches Elektronen-Synchrotron, Hamburg, Germany, are described. The equipment is based on the commercially available Freemelt ONE PBF-EB system but has been customized with a unique process chamber to enable real-time synchrotron measurements during the additive manufacturing process. Furthermore, a new unconfined powder bed design to replicate the conditions of the full-scale PBF-EB process is introduced. The first radiography (15 kHz) and diffraction (1 kHz) measurements of PBF-EB with a hot-work tool steel and a Ni-base superalloy, as well as bulk metal melting with the CMSX-4 alloy, using the sample environment are presented. MiniMelt enables time-resolved investigations of the dynamic phenomena taking place during multi-layer PBF-EB, facilitating process understanding and development of advanced process strategies and materials for PBF-EB.

3.
Bioact Mater ; 28: 155-166, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37250865

ABSTRACT

The microstructural architecture of remodeled bone in the peri-implant region of screw implants plays a vital role in the distribution of strain energy and implant stability. We present a study in which screw implants made from titanium, polyetheretherketone and biodegradable magnesium-gadolinium alloys were implanted into rat tibia and subjected to a push-out test four, eight and twelve weeks after implantation. Screws were 4 mm in length and with an M2 thread. The loading experiment was accompanied by simultaneous three-dimensional imaging using synchrotron-radiation microcomputed tomography at 5 µm resolution. Bone deformation and strains were tracked by applying optical flow-based digital volume correlation to the recorded image sequences. Implant stabilities measured for screws of biodegradable alloys were comparable to pins whereas non-degradable biomaterials experienced additional mechanical stabilization. Peri-implant bone morphology and strain transfer from the loaded implant site depended heavily on the biomaterial utilized. Titanium implants stimulated rapid callus formation displaying a consistent monomodal strain profile whereas the bone volume fraction in the vicinity of magnesium-gadolinium alloys exhibited a minimum close to the interface of the implant and less ordered strain transfer. Correlations in our data suggest that implant stability benefits from disparate bone morphological properties depending on the biomaterial utilized. This leaves the choice of biomaterial as situational depending on local tissue properties.

4.
Sci Rep ; 13(1): 6996, 2023 04 28.
Article in English | MEDLINE | ID: mdl-37117518

ABSTRACT

Phase-contrast computed tomography can visualize soft tissue samples with high contrast. At coherent sources, propagation-based imaging (PBI) techniques are among the most common, as they are easy to implement and produce high-resolution images. Their downside is a low degree of quantitative data due to simplifying assumptions of the sample properties in the reconstruction. These assumptions can be avoided, by using quantitative phase-contrast techniques as an alternative. However, these often compromise spatial resolution and require complicated setups. In order to overcome this limitation, we designed and constructed a new imaging setup using a 2D Talbot array illuminator as a wavefront marker and speckle-based imaging phase-retrieval techniques. We developed a post-processing chain that can compensate for wavefront marker drifts and that improves the overall sensitivity. By comparing two measurements of biomedical samples, we demonstrate that the spatial resolution of our setup is comparable to the one of PBI scans while being able to successfully image a sample that breaks the typical homogeneity assumption used in PBI.


Subject(s)
Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed , X-Rays , Tomography, X-Ray Computed/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Microscopy, Phase-Contrast
6.
Regen Biomater ; 10: rbac077, 2023.
Article in English | MEDLINE | ID: mdl-36683753

ABSTRACT

Magnesium (Mg)-based implants are highly attractive for the orthopedic field and may replace titanium (Ti) as support for fracture healing. To determine the implant-bone interaction in different bony regions, we implanted Mg-based alloy ZX00 (Mg < 0.5 Zn < 0.5 Ca, in wt%) and Ti-screws into the distal epiphysis and distal metaphysis of sheep tibiae. The implant degradation and osseointegration were assessed in vivo and ex vivo after 4, 6 and 12 weeks, using a combination of clinical computed tomography, medium-resolution micro computed tomography (µCT) and high-resolution synchrotron radiation µCT (SRµCT). Implant volume loss, gas formation and bone growth were evaluated for both implantation sites and each bone region independently. Additionally, histological analysis of bone growth was performed on embedded hard-tissue samples. We demonstrate that in all cases, the degradation rate of ZX00-implants ranges between 0.23 and 0.75 mm/year. The highest degradation rates were found in the epiphysis. Bone-to-implant contact varied between the time points and bone types for both materials. Mostly, bone-volume-to-total-volume was higher around Ti-implants. However, we found an increased cortical thickness around the ZX00-screws when compared with the Ti-screws. Our results showed the suitability of ZX00-screws for implantation into the distal meta- and epiphysis.

7.
J Med Imaging (Bellingham) ; 9(3): 031505, 2022 May.
Article in English | MEDLINE | ID: mdl-35310450

ABSTRACT

Purpose: Dental calculus forms on teeth during the life of an individual and its investigation can yield information about diet, health status, and environmental pollution. Currently, the analytical techniques used to visualize the internal structure of human dental calculus and entrapped inclusions are limited and require destructive sampling, which cannot always be justified. Approach: We used propagation phase-contrast synchrotron radiation micro-computed tomography (PPC-SR- µ CT ) to non-destructively examine the internal organization of dental calculus, including its microstructure and entrapped inclusions, on both modern and archeological samples. Results: The virtual histological exploration of the samples shows that PPC-SR- µ CT is a powerful approach to visualize the internal organization of dental calculus. We identified several important features, including previously undetected negative imprints of enamel and dentine growth markers (perikymata and periradicular bands, respectively), the non-contiguous structure of calculus layers with multiple voids, and entrapped plant remains. Conclusions: PPC-SR- µ CT is an effective technique to explore dental calculus structural organization, and is especially powerful for enabling the identification of inclusions. The non-destructive nature of synchrotron tomography helps protect samples for future research. However, the irregular layers and frequent voids reveal a high heterogeneity and variability within calculus, with implications for research focusing on inclusions.

8.
ACS Appl Mater Interfaces ; 13(18): 21924-21935, 2021 May 12.
Article in English | MEDLINE | ID: mdl-33929833

ABSTRACT

Active hybrid composites represent a novel class of smart materials used to design morphing surfaces, opening up new applications in the aircraft and automotive industries. The bending of the active hybrid composite is induced by the contraction of electrically activated shape memory alloy (SMA) wires, which are placed with an offset to the neutral axis of the composite. Therefore, the adhesion strength between the SMA wire and the surrounding polymer matrix is crucial to the load transfer and the functionality of the composite. Thus, the interface adhesion strength is of great importance for the performance and the actuation potential of active hybrid composites. In this work, the surface of a commercially available one-way effect NiTi SMA wire with a diameter of 1 mm was structured by selective electrochemical etching that preferably starts at defect sites, leaving the most thermodynamically stable surfaces of the wire intact. The created etch pits lead to an increase in the surface area of the wire and a mechanical interlocking with the polymer, resulting in a combination of adhesive and cohesive failure modes after a pull-out test. Consequently, the force of the first failure determined by an optical stress measurement was increased by more than 3 times when compared to the as-delivered SMA wire. The actuation characterization test showed that approximately the same work capacity could be retrieved from structured SMA wires. Moreover, structured SMA wires exhibited the same shape of the stress-strain curve as the as-delivered SMA wire, and the mechanical performance was not influenced by the structuring process. The austenite start As and austenite finish Af transformation temperatures were also not found to be affected by the structuring process. The formation of etching pits with different geometries and densities was discussed with regard to the kinetics of oxide formation and dissolution.

9.
Optica ; 8(12): 1588-1595, 2021 Dec 20.
Article in English | MEDLINE | ID: mdl-37829605

ABSTRACT

Two-dimensional (2D) Talbot array illuminators (TAIs) were designed, fabricated, and evaluated for high-resolution high-contrast x-ray phase imaging of soft tissue at 10-20 keV. The TAIs create intensity modulations with a high compression ratio on the micrometer scale at short propagation distances. Their performance was compared with various other wavefront markers in terms of period, visibility, flux efficiency, and flexibility to be adapted for limited beam coherence and detector resolution. Differential x-ray phase contrast and dark-field imaging were demonstrated with a one-dimensional, linear phase stepping approach yielding 2D phase sensitivity using unified modulated pattern analysis (UMPA) for phase retrieval. The method was employed for x-ray phase computed tomography reaching a resolution of 3 µm on an unstained murine artery. It opens new possibilities for three-dimensional, non-destructive, and quantitative imaging of soft matter such as virtual histology. The phase modulators can also be used for various other x-ray applications such as dynamic phase imaging, super-resolution structured illumination microscopy, or wavefront sensing.

10.
Sci Rep ; 9(1): 14348, 2019 10 04.
Article in English | MEDLINE | ID: mdl-31586080

ABSTRACT

Atherosclerotic arteries exhibit characteristic constrictions and substantial deviations from cylindrical shape. Therefore, determining the artery's cross-section along the centerline is challenging, although high-resolution isotropic three-dimensional data are available. Herein, we apply high-resolution computed tomography in absorption and phase to a plaque-containing human artery post-mortem, through the course of the preparation stages for histology. We identify the impact of paraffin embedding and decalcification on the artery lumen. For automatic extraction of lumen's cross-section along centerline we present a dedicated pipeline. Comparing fixated tissue before and after paraffin embedding gives rise to shape changes with lumen reduction to 50-80%. The histological slicing induces further deformations with respect to tomography. Data acquired after decalcification show debris unintentionally distributed within the vessel preventing the reliable automatic lumen segmentation. Comparing tomography of laboratory- and synchrotron-radiation-based X rays by means of joint histogram analysis leads us to conclude that advanced desktop tomography is capable of quantifying the artery's lumen as an essential input for blood flow simulations. The results indicate that the most reliable lumen quantification is achieved by imaging the non-decalcified specimen fixed in formalin, using phase contrast modality and a dedicated processing pipeline. This study focusses on a methodology to quantitatively evaluate diseased artery segments post-mortem and provides unique structural parameters on the treatment-induced local shrinkage, which will be the basis of future studies on the flow in vessels affected by constrictions.


Subject(s)
Coronary Vessels/diagnostic imaging , Imaging, Three-Dimensional , Plaque, Atherosclerotic/pathology , Tomography, X-Ray Computed , Coronary Vessels/pathology , Humans , Paraffin Embedding
12.
ACS Infect Dis ; 4(8): 1188-1196, 2018 08 10.
Article in English | MEDLINE | ID: mdl-29750862

ABSTRACT

The cell envelope of Gram-negative bacteria is a formidable biological barrier, inhibiting the action of antibiotics by impeding their permeation into the intracellular environment. In-depth understanding of permeation through this barrier remains a challenge, despite its critical role in antibiotic activity. We therefore designed a divisible in vitro permeation model of the Gram-negative bacterial cell envelope, mimicking its three essential structural elements, the inner membrane and the periplasmic space as well as the outer membrane, on a Transwell setup. The model was characterized by contemporary imaging techniques and employed to generate reproducible quantitative and time-resolved permeation data for various fluorescent probes and anti-infective molecules of different structure and physicochemical properties. For a set of three fluorescent probes, the permeation through the overall membrane model was found to correlate with in bacterio permeation. Even more interestingly, for a set of six Pseudomonas quorum sensing inhibitors, such permeability data were found to be predictive for their corresponding in bacterio activities. Further exploration of the capabilities of the overall model yielded a correlation between the permeability of porin-independent antibiotics and published in bacterio accumulation data; a promising ability to provide structure-permeability information was also demonstrated. Such a model may therefore constitute a valuable tool for the development of novel anti-infective drugs.


Subject(s)
Anti-Bacterial Agents/metabolism , Cell Membrane/chemistry , Cell Membrane/metabolism , Gram-Negative Bacteria/drug effects , Periplasm/chemistry , Periplasm/metabolism , Permeability , Biological Transport , Fluorescent Dyes/metabolism , Models, Theoretical , Optical Imaging/methods
13.
Opt Lett ; 42(23): 4982-4985, 2017 Dec 01.
Article in English | MEDLINE | ID: mdl-29216161

ABSTRACT

Reconstructing tomographic images of high resolution, as in x-ray microscopy or transmission electron microscopy, is often limited by the stability of the stages or sample drifts, which requires an image alignment prior to reconstruction. Feature-based image registration is routinely used to align images, but this technique relies on strong features in the sample or the application of gold tracer particles, for example. In this Letter, we present an analytic approach for achieving the vertical registration based on the inherent properties of the data acquired for tomographic reconstruction. It is computationally cheap to implement and can be easily integrated into existing reconstruction pipelines.

14.
Arthropod Struct Dev ; 46(1): 63-76, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27288588

ABSTRACT

Terrestrial isopods moult first the posterior and then the anterior half of the body, allowing for storage and recycling of CaCO3. We used synchrotron-radiation microtomography to estimate mineral content within skeletal segments in sequential moulting stages of Porcellio scaber. The results suggest that all examined cuticular segments contribute to storage and recycling, however, to varying extents. The mineral within the hepatopancreas after moult suggests an uptake of mineral from the ingested exuviae. The total maximum loss of mineral was 46% for the anterior and 43% for the posterior cuticle. The time course of resorption of mineral and mineralisation of the new cuticle suggests storage and recycling of mineral in the posterior and anterior cuticle. The mineral in the anterior pereiopods decreases by 25% only. P. scaber has long legs and can run fast; therefore, a less mineralised and thus lightweight cuticle in pereiopods likely serves to lower energy consumption during escape behaviour. Differential demineralisation occurs in the head cuticle, in which the cornea of the complex eyes remains completely mineralised. The partes incisivae of the mandibles are mineralised before the old cuticle is demineralised and shed. Probably, this enables the animal to ingest the old exuviae after each half moult.


Subject(s)
Hepatopancreas/physiology , Insect Proteins/physiology , Isopoda/physiology , Minerals/chemistry , Mouth/physiology , Animals , Calcification, Physiologic , Calcium Carbonate/chemistry , Computer Simulation , Cornea/physiology , Head/physiology , Image Processing, Computer-Assisted , Molting , Synchrotrons , X-Ray Microtomography
15.
J Synchrotron Radiat ; 23(Pt 6): 1440-1446, 2016 11 01.
Article in English | MEDLINE | ID: mdl-27787250

ABSTRACT

Photonic glass is a material class that can be used as photonic broadband reflectors, for example in the infrared regime as thermal barrier coating films. Photonic properties such as the reflectivity depend on the ordering and material packing fraction over the complete film thickness of up to 100 µm. Nanotomography allows acquiring these key parameters throughout the sample volume at the required resolution in a non-destructive way. By performing a nanotomography measurement at the PETRA III beamline P05 on a photonic glass film, the packing fraction throughout the complete sample thickness was analyzed. The results showed a packing fraction significantly smaller than the expected random close packing giving important information for improving the fabrication and processing methods of photonic glass material in the future.

16.
J Morphol ; 276(12): 1505-24, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26363277

ABSTRACT

The external and internal features of the larval head of Rhyacophila fasciata (Trichoptera: Rhyacophilidae) were described in detail. Anatomical examinations were carried out using a multimethod approach including histology, scanning electron microscopy, confocal laser-scanning microscopy, microcomputed tomography, and computer-based three-dimensional reconstructions. Additionally, the information on the larval head of Limnephilus flavicornis (Limnephilidae) and Hydropsyche angustipennis (Hydropsychidae) available in the literature were reinvestigated. These anatomical data were used to address major questions of homology and terminology, that is, the ventral closure of the head capsule, the sclerites, and appendages of labium and maxilla and their muscles. These topics were discussed by summarizing the main hypotheses present in the literature and a critical inclusion of new findings. Consequently, the inner lobe of the maxilla very likely represents the galea. The distal maxillary sclerite (palpifer) is an anatomical composite formation at least including dististipes and lacinia. Based on these homology hypotheses several potential groundplan features of the larval head of Trichoptera were reconstructed. The head of Rhyacophila shows several presumably plesiomorphic features as for instance the prognath orientation of the mouthparts, the well-developed hypocranial bridge, the triangular submentum and eyes composed of seven stemmata. Derived features of Rhyacophila are the reduced antennae, the anterior directing of three stemmata and the shift of the tentorio-stipital muscle to the mentum.


Subject(s)
Head/anatomy & histology , Insecta/anatomy & histology , Animals , Head/diagnostic imaging , Insecta/classification , Larva/anatomy & histology , Muscles/anatomy & histology , X-Ray Microtomography
17.
Microsc Microanal ; 21(5): 1288-95, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26306692

ABSTRACT

X-ray micro-computed tomography (µCT) is commonly used for imaging of samples in biomedical or materials science research. Owing to the ability to visualize a sample in a nondestructive way, X-ray µCT is perfectly suited to inspect fossilized specimens, which are mostly unique or rare. In certain regions of the world where important sedimentation events occurred in the Precambrian geological time, several fossilized animals are studied to understand questions related to their origin, environment, and life evolution. This article demonstrates the advantages of applying absorption and phase-contrast CT on the enigmatic fossil Corumbella werneri, one of the oldest known animals capable of building hard parts, originally discovered in Corumbá (Brazil). Different tomographic setups were tested to visualize the fossilized inner structures: a commercial laboratory-based µCT device, two synchrotron-based imaging setups using conventional absorption and propagation-based phase contrast, and a commercial X-ray microscope with a lens-coupled detector system, dedicated for radiography and tomography. Based on our results we discuss the strengths and weaknesses of the different imaging setups for paleontological studies.


Subject(s)
Fossils/diagnostic imaging , Paleontology/methods , Tomography, X-Ray/methods , Animals , Brazil
18.
Nat Protoc ; 9(6): 1401-15, 2014.
Article in English | MEDLINE | ID: mdl-24853926

ABSTRACT

A key problem in X-ray computed tomography is choosing photon energies for postmortem specimens containing both soft and hard tissues. Increasing X-ray energy reduces image artifacts from highly absorbing hard tissues including plaque, but it simultaneously decreases contrast in soft tissues including the endothelium. Therefore, identifying the lumen within plaque-containing vessels is challenging. Destructive histology, the gold standard for tissue evaluation, reaches submicron resolution in two dimensions, whereas slice thickness limits spatial resolution in the third. We present a protocol to systematically analyze heterogeneous tissues containing weakly and highly absorbing components in the original wet state, postmortem. Taking the example of atherosclerotic human coronary arteries, the successively acquired 3D data of benchtop and synchrotron radiation-based tomography are validated by histology. The entire protocol requires ∼20 working days, enables differentiation between plaque, muscle and fat tissues without using contrast agents and permits blood flow simulations in vessels with plaque-induced constrictions.


Subject(s)
Imaging, Three-Dimensional/methods , Tomography, X-Ray Computed/methods , Coronary Vessels/ultrastructure , Histological Techniques , Humans , Plaque, Atherosclerotic/pathology
20.
Acta Biomater ; 10(1): 355-64, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23993945

ABSTRACT

Carious lesions exhibit a complex structural organization composed of zones of higher and lower mineralization, formed by successive periods of cyclic de- and re-mineralization. A thorough understanding of the lesion morphology is necessary for the development of suitable treatments aiming to repair rather than replace the damaged tissue. This detailed understanding includes the entire lesion down to individual crystallites and nanopores within the natural organization of the crown. A moderate lesion, with surface loss and reaching dentin, and a very early lesion were studied. Scanning small-angle X-ray scattering (SAXS) with a pixel size of 20 × 20 µm(2) was used to characterize these lesions, allowing for the identification of distinct zones with varied absorption and scattering behavior, indicative of varied porosity and pore morphology. Despite these differences, the overall orientation and anisotropy of the SAXS signal was unaltered throughout both lesions, indicating that an anisotropic scaffold is still present in the lesion. The finding that crystallite orientation is preserved throughout the lesions facilitates the identification of preventive re-mineralizing strategies with the potential to recreate the original nanostructure.


Subject(s)
Dental Caries/pathology , Dental Enamel/pathology , Nanostructures/chemistry , Dental Caries/diagnostic imaging , Dental Enamel/diagnostic imaging , Dentin/metabolism , Humans , Scattering, Radiation , Surface Properties , X-Ray Microtomography , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...