Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 115
Filter
1.
JNCI Cancer Spectr ; 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730548

ABSTRACT

BACKGROUND: Traditional constraints specify that 700 cc of liver should be spared a hepatotoxic dose when delivering liver-directed radiotherapy to reduce the risk of inducing liver failure. We investigated the role of single photon emission computed tomography (SPECT) to identify and preferentially avoid functional liver during liver-directed radiation treatment planning in patients with preserved liver function but limited functional liver volume after receiving prior hepatotoxic chemotherapy or surgical resection. METHODS: This phase I trial with a 3 + 3 design evaluated the safety of liver-directed radiotherapy using escalating functional liver radiation dose constraints in patients with liver metastases. Dose limiting toxicities (DLTs) were assessed 6-8 weeks and 6 months after completing radiotherapy. RESULTS: All twelve patients had colorectal liver metastases and received prior hepatotoxic chemotherapy. Eight patients underwent prior liver resection. Median computed tomography (CT) anatomical non-tumor liver volume was 1,584 cc (range 764-2,699 cc). Median SPECT functional liver volume was 1,117 cc (range 570-1,928cc). Median non-target CT and SPECT liver volumes below the volumetric dose constraint were 997 cc (range 544-1,576 cc) and 684 cc (range 429-1,244 cc), respectively. The prescription dose was 67.5-75 Gy in 15 fractions or 75-100 Gy in 25 fractions. No DLTs were observed during follow-up. One-year in-field control was 57%. One-year overall survival was 73%. CONCLUSION: Liver-directed radiotherapy can be safely delivered to high doses when incorporating functional SPECT into the radiation treatment planning process which may enable sparing of lower volumes of liver than traditionally accepted in patients with preserved liver function. TRIAL REGISTRATION: NCT02626312.

2.
Sensors (Basel) ; 24(7)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38610351

ABSTRACT

Proton radiography is a promising development in proton therapy, and researchers are currently exploring optimal detector materials to construct proton radiography detector arrays. High-density glass scintillators may improve integrating-mode proton radiography detectors by increasing spatial resolution and decreasing detector thickness. We evaluated several new scintillators, activated with europium or terbium, with proton response measurements and Monte Carlo simulations, characterizing relative luminosity, ionization quenching, and proton radiograph spatial resolution. We applied a correction based on Birks's analytical model for ionization quenching. The data demonstrate increased relative luminosity with increased activation element concentration, and higher relative luminosity for samples activated with europium. An increased glass density enables more compact detector geometries and higher spatial resolution. These findings suggest that a tungsten and gadolinium oxide-based glass activated with 4% europium is an ideal scintillator for testing in a full-size proton radiography detector.

4.
Med Phys ; 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38507253

ABSTRACT

BACKGROUND: Dosimetry in ultra-high dose rate (UHDR) beamlines is significantly challenged by limitations in real-time monitoring and accurate measurement of beam output, beam parameters, and delivered doses using conventional radiation detectors, which exhibit dependencies in ultra-high dose-rate (UHDR) and high dose-per-pulse (DPP) beamline conditions. PURPOSE: In this study, we characterized the response of the Exradin W2 plastic scintillator (Standard Imaging, Inc.), a water-equivalent detector that provides measurements with a time resolution of 100 Hz, to determine its feasibility for use in UHDR electron beamlines. METHODS: The W2 scintillator was exposed to an UHDR electron beam with different beam parameters by varying the pulse repetition frequency (PRF), pulse width (PW), and pulse amplitude settings of an electron UHDR linear accelerator system. The response of the W2 scintillator was evaluated as a function of the total integrated dose delivered, DPP, and mean and instantaneous dose rate. To account for detector radiation damage, the signal sensitivity (pC/Gy) of the W2 scintillator was measured and tracked as a function of dose history. RESULTS: The W2 scintillator demonstrated mean dose rate independence and linearity as a function of integrated dose and DPP for DPP ≤ 1.5 Gy (R2 > 0.99) and PRF ≤ 90 Hz. At DPP > 1.5 Gy, nonlinear behavior and signal saturation in the blue and green signals as a function of DPP, PRF, and integrated dose became apparent. In the absence of Cerenkov correction, the W2 scintillator exhibited PW dependence, even at DPP values <1.5 Gy, with a difference of up to 31% and 54% in the measured blue and green signal for PWs ranging from 0.5 to 3.6 µs. The change in signal sensitivity of the W2 scintillator as a function of accumulated dose was approximately 4%/kGy and 0.3%/kGy for the measured blue and green signal responses, respectively, as a function of integrated dose history. CONCLUSION: The Exradin W2 scintillator can provide output measurements that are both dose rate independent and linear in response if the DPP is kept ≤1.5 Gy (corresponding to a mean dose rate up to 290 Gy/s in the used system), as long as proper calibration is performed to account for PW and changes in signal sensitivity as a function of accumulated dose. For DPP > 1.5 Gy, the W2 scintillator's response becomes nonlinear, likely due to limitations in the electrometer related to the high signal intensity.

5.
ArXiv ; 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38495573

ABSTRACT

Background: Scintillation dosimetry has promising qualities for ultra-high dose rate (UHDR) radiotherapy (RT), but no system has shown compatibility with mean dose rates (DR-) above 100 Gy/s and doses per pulse (Dp) exceeding 1.5 Gy typical of UHDR (FLASH)-RT. The aim of this study was to characterize a novel scintillator dosimetry system with the potential of accommodating UHDRs. Methods and Materials: A thorough dosimetric characterization of the system was performed on an UHDR electron beamline. The system's response as a function of dose, DR-,Dp, and the pulse dose rate DRp was investigated, together with the system's dose sensitivity (signal per unit dose) as a function of dose history. The capabilities of the system for time-resolved dosimetric readout were also evaluated. Results: Within a tolerance of ±3%, the system exhibited dose linearity and was independent of DR- and Dp within the tested ranges of 1.8-1341 Gy/s and 0.005-7.68 Gy, respectively. A 6% reduction in the signal per unit dose was observed as DRp was increased from 8.9e4-1.8e6 Gy/s. Additionally, the dose delivered per integration window of the continuously sampling photodetector had to remain between 0.028 and 11.64 Gy to preserve a stable signal response per unit dose. The system accurately measured Dp of individual pulses delivered at up to 120 Hz. The day-to-day variation of the signal per unit dose at a reference setup varied by up to ±13% but remained consistent (<±2%) within each day of measurements and showed no signal loss as a function of dose history. Conclusions: With daily calibrations and DRp specific correction factors, the system reliably provides real-time, millisecond-resolved dosimetric measurements of pulsed conventional and UHDR beams from typical electron linacs, marking an important advancement in UHDR dosimetry and offering diverse applications to FLASH-RT and related fields.

6.
J Appl Clin Med Phys ; 25(4): e14259, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38317597

ABSTRACT

BACKGROUND: The treatment planning process from segmentation to producing a deliverable plan is time-consuming and labor-intensive. Existing solutions automate the segmentation and planning processes individually. The feasibility of combining auto-segmentation and auto-planning for volumetric modulated arc therapy (VMAT) for rectal cancers in an end-to-end process is not clear. PURPOSE: To create and clinically evaluate a complete end-to-end process for auto-segmentation and auto-planning of VMAT for rectal cancer requiring only the gross tumor volume contour and a CT scan as inputs. METHODS: Patient scans and data were retrospectively selected from our institutional records for patients treated for malignant neoplasm of the rectum. We trained, validated, and tested deep learning auto-segmentation models using nnU-Net architecture for clinical target volume (CTV), bowel bag, large bowel, small bowel, total bowel, femurs, bladder, bone marrow, and female and male genitalia. For the CTV, we identified 174 patients with clinically drawn CTVs. We used data for 18 patients for all structures other than the CTV. The structures were contoured under the guidance of and reviewed by a gastrointestinal (GI) radiation oncologist. The predicted results for CTV in 35 patients and organs at risk (OAR) in six patients were scored by the GI radiation oncologist using a five-point Likert scale. For auto-planning, a RapidPlan knowledge-based planning solution was modeled for VMAT delivery with a prescription of 25 Gy in five fractions. The model was trained and tested on 20 and 34 patients, respectively. The resulting plans were scored by two GI radiation oncologists using a five-point Likert scale. Finally, the end-to-end pipeline was evaluated on 16 patients, and the resulting plans were scored by two GI radiation oncologists. RESULTS: In 31 of 35 patients, CTV contours were clinically acceptable without necessary modifications. The CTV achieved a Dice similarity coefficient of 0.85 (±0.05) and 95% Hausdorff distance of 15.25 (±5.59) mm. All OAR contours were clinically acceptable without edits, except for large and small bowel which were challenging to differentiate. However, contours for total, large, and small bowel were clinically acceptable. The two physicians accepted 100% and 91% of the auto-plans. For the end-to-end pipeline, the two physicians accepted 88% and 62% of the auto-plans. CONCLUSIONS: This study demonstrated that the VMAT treatment planning technique for rectal cancer can be automated to generate clinically acceptable and safe plans with minimal human interventions.


Subject(s)
Radiotherapy, Intensity-Modulated , Rectal Neoplasms , Humans , Male , Female , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies , Radiotherapy Dosage , Rectal Neoplasms/radiotherapy , Rectum , Organs at Risk , Radiotherapy Planning, Computer-Assisted/methods
7.
Phys Med Biol ; 69(5)2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38241716

ABSTRACT

Integrated-mode proton radiography leading to water equivalent thickness (WET) maps is an avenue of interest for motion management, patient positioning, andin vivorange verification. Radiographs can be obtained using a pencil beam scanning setup with a large 3D monolithic scintillator coupled with optical cameras. Established reconstruction methods either (1) involve a camera at the distal end of the scintillator, or (2) use a lateral view camera as a range telescope. Both approaches lead to limited image quality. The purpose of this work is to propose a third, novel reconstruction framework that exploits the 2D information provided by two lateral view cameras, to improve image quality achievable using lateral views. The three methods are first compared in a simulated Geant4 Monte Carlo framework using an extended cardiac torso (XCAT) phantom and a slanted edge. The proposed method with 2D lateral views is also compared with the range telescope approach using experimental data acquired with a plastic volumetric scintillator. Scanned phantoms include a Las Vegas (contrast), 9 tissue-substitute inserts (WET accuracy), and a paediatric head phantom. Resolution increases from 0.24 (distal) to 0.33 lp mm-1(proposed method) on the simulated slanted edge phantom, and the mean absolute error on WET maps of the XCAT phantom is reduced from 3.4 to 2.7 mm with the same methods. Experimental data from the proposed 2D lateral views indicate a 36% increase in contrast relative to the range telescope method. High WET accuracy is obtained, with a mean absolute error of 0.4 mm over 9 inserts. Results are presented for various pencil beam spacing ranging from 2 to 6 mm. This work illustrates that high quality proton radiographs can be obtained with clinical beam settings and the proposed reconstruction framework with 2D lateral views, with potential applications in adaptive proton therapy.


Subject(s)
Proton Therapy , Protons , Humans , Child , Algorithms , Radiography , Proton Therapy/methods , Phantoms, Imaging , Monte Carlo Method
8.
Brachytherapy ; 23(2): 165-172, 2024.
Article in English | MEDLINE | ID: mdl-38281894

ABSTRACT

PURPOSE: To use quantities measurable during in vivo dosimetry to build unique channel identifiers, that enable detection of brachytherapy errors. MATERIALS AND METHODS: Treatment plan of 360 patients with prostate cancer who underwent high-dose-rate brachytherapy (range, 16-25 catheters; mean, 17) were used. A single point virtual dosimeter was placed at multiple positions within the treatment geometry, and the source-dosimeter distance and dwell time were determined for each dwell position in each catheter. These values were compared across all catheters, dwell position by dwell position, simulating a treatment delivery. A catheter was considered uniquely identified if, for a given dwell position, no other catheters had the same measured values. The minimum number of dwell positions needed to identify a specific catheter and the optimal dosimeter location uniquely were determined. The radial (r) and vertical (z) dimensions of the source-dosimeter distance were also examined for their utility in discriminating catheters. RESULTS: Using a virtual dosimeter with no uncertainties, all catheters were identified in 359 of the 360 cases with 9 dwell position measurements. When only the dwell time were measured, all catheters were uniquely identified after 1 dwell position. With a 2-mm spatial accuracy (r,z), all catheters were identified in 94% of the plans. Simultaneous measurement of source-dosimeter distance and dwell time ensured full catheter identification in all plans ranging from 2 to 6 dwell positions. The number of dwell positions needed to uniquely identify all catheters was lower when the distance from the implant center was higher. CONCLUSIONS: The most efficient fingerprinting approach involved combining source-dosimeter distance (i.e., source tracking) and dwell time. The further the dosimeter is placed from the center of the implant the better it can uniquely identify catheters.


Subject(s)
Brachytherapy , In Vivo Dosimetry , Male , Humans , Radiotherapy Dosage , Brachytherapy/methods , Phantoms, Imaging , Catheters , Radiotherapy Planning, Computer-Assisted/methods
9.
Med Phys ; 51(1): 494-508, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37696271

ABSTRACT

Ion chambers are required for calibration and reference dosimetry applications in radiation therapy (RT). However, exposure of ion chambers in ultra-high dose rate (UHDR) conditions pertinent to FLASH-RT leads to severe saturation and ion recombination, which limits their performance and usability. The purpose of this study was to comprehensively evaluate a set of commonly used commercially available ion chambers in RT, all with different design characteristics, and use this information to produce a prototype ion chamber with improved performance in UHDR conditions as a first step toward ion chambers specific for FLASH-RT. The Advanced Markus and Exradin A10, A26, and A20 ion chambers were evaluated. The chambers were placed in a water tank, at a depth of 2 cm, and exposed to an UHDR electron beam at different pulse repetition frequency (PRF), pulse width (PW), and pulse amplitude settings on an IntraOp Mobetron. Ion chamber responses were investigated for the various beam parameter settings to isolate their dependence on integrated dose, mean dose rate and instantaneous dose rate, dose-per-pulse (DPP), and their design features such as chamber type, bias voltage, and collection volume. Furthermore, a thin parallel-plate (TPP) prototype ion chamber with reduced collector plate separation and volume was constructed and equally evaluated as the other chambers. The charge collection efficiency of the investigated ion chambers decreased with increasing DPP, whereas the mean dose rate did not affect the response of the chambers (± 1%). The dependence of the chamber response on DPP was found to be solely related to the total dose within the pulse, and not on mean dose rate, PW, or instantaneous dose rate within the ranges investigated. The polarity correction factor (Ppol ) values of the TPP prototype, A10, and Advanced Markus chambers were found to be independent of DPP and dose rate (± 2%), while the A20 and A26 chambers yielded significantly larger variations and dependencies under the same conditions. Ion chamber performance evaluated under different irradiation conditions of an UHDR electron beam revealed a strong dependence on DPP and a negligible dependence on the mean and instantaneous dose rates. These results suggest that modifications to ion chambers design to improve their usability in UHDR beamlines should focus on minimizing DPP effects, with emphasis on optimizing the electric field strength, through the construction of smaller electrode separation and larger bias voltages. This was confirmed through the production and evaluation of a prototype ion chamber specifically designed with these characteristics.


Subject(s)
Electrons , Radiometry , Radiometry/methods , Calibration , Water
10.
Lancet Oncol ; 24(12): 1387-1398, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38039992

ABSTRACT

BACKGROUND: Stereotactic body radiotherapy (SBRT) has the potential to ablate localised pancreatic ductal adenocarcinoma. Selective dismutase mimetics sensitise tumours while reducing normal tissue toxicity. This trial was designed to establish the efficacy and toxicity afforded by the selective dismutase mimetic avasopasem manganese when combined with ablative SBRT for localised pancreatic ductal adenocarcinoma. METHODS: In this adaptive, randomised, double-blind, placebo-controlled, phase 1b/2 trial, patients aged 18 years or older with borderline resectable or locally advanced pancreatic cancer who had received at least 3 months of chemotherapy and had an Eastern Cooperative Oncology Group performance status of 0-2 were enrolled at six academic sites in the USA. Eligible patients were randomly assigned (1:1), with block randomisation (block sizes of 6-12) with a maximum of 24 patients per group, to receive daily avasopasem (90 mg) or placebo intravenously directly before (ie, within 180 min) SBRT (50, 55, or 60 Gy in five fractions, adaptively assigned in real time by Bayesian estimates of 90-day safety and efficacy). Patients and physicians were masked to treatment group allocation, but not to SBRT dose. The primary objective was to find the optimal dose of SBRT with avasopasem or placebo as determined by the late onset EffTox method. All analyses were done on an intention-to-treat basis. This study is registered with ClinicalTrials.gov, NCT03340974, and is complete. FINDINGS: Between Jan 25, 2018, and April 29, 2020, 47 patients were screened, of whom 42 were enrolled (median age was 71 years [IQR 63-75], 23 [55%] were male, 19 [45%] were female, 37 [88%] were White, three [7%] were Black, and one [2%] each were unknown or other races) and randomly assigned to avasopasem (n=24) or placebo (n=18); the placebo group was terminated early after failing to meet prespecified efficacy parameters. At data cutoff (June 28, 2021), the avasopasem group satisfied boundaries for both efficacy and toxicity. Late onset EffTox efficacy response was observed in 16 (89%) of 18 patients at 50 Gy and six (100%) of six patients at 55 Gy in the avasopasem group, and was observed in three (50%) of six patients at 50 Gy and nine (75%) of 12 patients at 55 Gy in the placebo group, and the Bayesian model recommended 50 Gy or 55 Gy in five fractions with avasopasem for further study. Serious adverse events of any cause were reported in three (17%) of 18 patients in the placebo group and six (25%) of 24 in the avasopasem group. In the placebo group, grade 3 adverse events within 90 days of SBRT were abdominal pain, acute cholangitis, pyrexia, increased blood lactic acid, and increased lipase (one [6%] each); no grade 4 events occurred. In the avasopasem group, grade 3-4 adverse events within 90 days of SBRT were acute kidney injury, increased blood alkaline phosphatase, haematoma, colitis, gastric obstruction, lung infection, abdominal abscess, post-surgical atrial fibrillation, and pneumonia leading to respiratory failure (one [4%] each).There were no treatment-related deaths but one late death in the avasopasem group due to sepsis in the setting of duodenal obstruction after off-study treatment was reported as potentially related to SBRT. INTERPRETATION: SBRT that uses 50 or 55 Gy in five fractions can be considered for patients with localised pancreatic ductal adenocarcinoma. The addition of avasopasem might further enhance disease outcomes. A larger phase 2 trial (GRECO-2, NCT04698915) is underway to validate these results. FUNDING: Galera Therapeutics.


Subject(s)
Adenocarcinoma , Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Radiosurgery , Humans , Male , Female , Aged , Adenocarcinoma/radiotherapy , Adenocarcinoma/drug therapy , Pancreatic Neoplasms/radiotherapy , Pancreatic Neoplasms/drug therapy , Radiosurgery/adverse effects , Bayes Theorem , Carcinoma, Pancreatic Ductal/radiotherapy , Carcinoma, Pancreatic Ductal/drug therapy , Double-Blind Method , Antineoplastic Combined Chemotherapy Protocols/therapeutic use
11.
Cancers (Basel) ; 15(22)2023 Nov 10.
Article in English | MEDLINE | ID: mdl-38001615

ABSTRACT

Accurate delivery of stereotactic body radiotherapy (SBRT) to pancreatic tumors relies on successful EUS-guided placement of fiducial markers. The aim of this study is to report the technical feasibility and safety of EUS-guided fiducial placement and to evaluate the characteristics and technical benefit of SBRT in a cohort of patients with pancreatic cancer (PC). A retrospective chart review was performed for all (n = 82) PC patients referred for EUS-guided fiducial placement by a single endosonographer at a tertiary cancer center. Data regarding EUS-related technical details, SBRT characteristics, adverse events, and continuous visibility of fiducials were recorded and analyzed. Most patients included in the study had either locally advanced disease (32 patients, 39%) or borderline resectable disease (29 patients, 35%). Eighty-two PC patients underwent the placement of 230 fiducial markers under EUS guidance. The technical success rate of the fiducial placement was 98%. No immediate EUS-related adverse events were reported. The average time to the simulation CT after fiducial placement was 3.1 days. Of the 216 fiducial markers used for the SBRT delivery, 202 fiducial markers were visible on both the simulation CT and the cone beam CT scan. A median dose of 40cGY was given to all the patients in five fractions. Of these, 41% of the patients reported no SBRT-related toxicities during the follow-up. Fatigue and nausea were the most reported SBRT-related toxicities, which were seen in 35% of the patients post-SBRT. Our results demonstrate that EUS-guided fiducial placement is safe and effective in target volume delineation, facilitating SBRT delivery in PC patients. Further clinical trials are needed to determine the SBRT-related survival benefits in patients with pancreatic cancer.

12.
Adv Radiat Oncol ; 8(4): 101164, 2023.
Article in English | MEDLINE | ID: mdl-36798731

ABSTRACT

Purpose: To determine the dosimetric limitations of daily online adaptive pancreas stereotactic body radiation treatment by using an automated dose escalation approach. Methods and Materials: We collected 108 planning and daily computed tomography (CT) scans from 18 patients (18 patients × 6 CT scans) who received 5-fraction pancreas stereotactic body radiation treatment at MD Anderson Cancer Center. Dose metrics from the original non-dose-escalated clinical plan (non-DE), the dose-escalated plan created on the original planning CT (DE-ORI), and the dose-escalated plan created on daily adaptive radiation therapy CT (DE-ART) were analyzed. We developed a dose-escalation planning algorithm within the radiation treatment planning system to automate the dose-escalation planning process for efficiency and consistency. In this algorithm, the prescription dose of the dose-escalation plan was escalated before violating any organ-at-risk (OAR) dose constraint. Dose metrics for 3 targets (gross target volume [GTV], tumor vessel interface [TVI], and dose-escalated planning target volume [DE-PTV]) and 9 OARs (duodenum, large bowel, small bowel, stomach, spinal cord, kidneys, liver, and skin) for the 3 plans were compared. Furthermore, we evaluated the effectiveness of the online adaptive dose-escalation planning process by quantifying the effect of the interfractional dose distribution variations among the DE-ART plans. Results: The median D95% dose to the GTV/TVI/DE-PTV was 33.1/36.2/32.4 Gy, 48.5/50.9/40.4 Gy, and 53.7/58.2/44.8 Gy for non-DE, DE-ORI, and DE-ART, respectively. Most OAR dose constraints were not violated for the non-DE and DE-ART plans, while OAR constraints were violated for the majority of the DE-ORI patients due to interfractional motion and lack of adaptation. The maximum difference per fraction in D95%, due to interfractional motion, was 2.5 ± 2.7 Gy, 3.0 ± 2.9 Gy, and 2.0 ± 1.8 Gy for the TVI, GTV, and DE-PTV, respectively. Conclusions: Most patients require daily adaptation of the radiation planning process to maximally escalate delivered dose to the pancreatic tumor without exceeding OAR constraints. Using our automated approach, patients can receive higher target dose than standard of care without violating OAR constraints.

13.
J Appl Clin Med Phys ; 24(2): e13891, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36601691

ABSTRACT

PURPOSE: To investigate the usefulness and effectiveness of a dual beam-current transformer (BCTs) design to monitor and record the beam dosimetry output and energy of pulsed electron FLASH (eFLASH) beams in real-time, and to inform on the usefulness of this design for future eFLASH beam control. METHODS: Two BCTs are integrated into the head of a FLASH Mobetron system, one located after the primary scattering foil and the other downstream of the secondary scattering foil. The response of the BCTs was evaluated individually to monitor beam output as a function of dose, scattering conditions, and ability to capture physical beam parameters such as pulse width (PW), pulse repetition frequency (PRF), and dose per pulse (DPP), and in combination to determine beam energy using the ratio of the lower-to-upper BCT signal. RESULTS: A linear relationship was observed between the absorbed dose measured on Gafchromic film and the BCT signals for both the upper and lower BCT (R2  > 0.99). A linear relationship was also observed in the BCT signals as a function of the number of pulses delivered regardless of the PW, DPP, or PRF (R2  > 0.99). The lower-to-upper BCT ratio was found to correlate strongly with the energy of the eFLASH beam due to differential beam attenuation caused by the secondary scattering foil. The BCTs were also able to provide accurate information about the PW, PRF, energy, and DPP for each individual pulse delivered in real-time. CONCLUSION: The dual BCT system integrated within the FLASH Mobetron was shown to be a reliable monitoring system able to quantify accelerator performance and capture all essential physical beam parameters on a pulse-by-pulse basis, and the ratio between the two BCTs was strongly correlated with beam energy. The fast signal readout and processing enables the BCTs to provide real-time information on beam output and energy and is proposed as a system suitable for accurate beam monitoring and control of eFLASH beams.


Subject(s)
Electrons , Radiotherapy Dosage , Humans , Radiometry
14.
Z Med Phys ; 33(2): 124-134, 2023 May.
Article in English | MEDLINE | ID: mdl-35750591

ABSTRACT

Compton-based prompt gamma (PG) imaging is being investigated by several groups as a potential solution for in vivo range monitoring in proton therapy. The performance of this technique depends on the detector system as well as the ability of the reconstruction method to obtain good spatial resolution to establish a quantitative correlation between the PG emission and the proton beam range in the patient. To evaluate the feasibility of PG imaging for range monitoring, we quantitatively evaluated the emission distributions reconstructed by a Maximum Likelihood Expectation Maximization (MLEM) and a Stochastic Origin Ensemble (SOE) algorithm. To this end, we exploit experimental and Monte Carlo (MC) simulation data acquired with the Polaris-J Compton Camera (CC) prototype. The differences between the proton beam range (RD) defined as the 80% distal dose fall-off and the PG range (RPG), obtained by fitting the distal end of the reconstructed profile with a sigmoid function, were quantified. A comparable performance of both reconstruction algorithms was found. For both experimental and simulated irradiation scenarios, the correlation between RD and RPG was within 5 mm. These values were consistent with the ground truth distance (RD-RPGg≈ 3 mm) calculated by using the expected PG emission available from MC simulation. Furthermore, shifts of 3 mm in the proton beam range were resolved with the MLEM algorithm by calculating the relative difference between the RPG for each reconstructed profile. In non-homogeneous targets, the spatial changes in the PG emission due to the different materials could not be fully resolved from the reconstructed profiles; however, the fall-off region still resembled the ground truth emission. For this scenario, the PG correlation (RD-RPG) varied from 0.1 mm to 4 mm, which is close to the ground truth correlation (3 mm). This work provides a framework for the evaluation of the range monitoring capabilities of a CC device for PG imaging. The two investigated image reconstruction algorithms showed a comparable and consistent performance for homogeneous and heterogeneous targets.


Subject(s)
Proton Therapy , Protons , Humans , Image Processing, Computer-Assisted/methods , Likelihood Functions , Phantoms, Imaging , Proton Therapy/methods , Algorithms , Monte Carlo Method
15.
IEEE Trans Radiat Plasma Med Sci ; 6(3): 366-373, 2022 Mar.
Article in English | MEDLINE | ID: mdl-36092269

ABSTRACT

The purpose of this study was to determine how the characteristics of the data acquisition (DAQ) electronics of a Compton camera (CC) affect the quality of the recorded prompt gamma (PG) interaction data and the reconstructed images, during clinical proton beam delivery. We used the Monte-Carlo-plus-Detector-Effect (MCDE) model to simulate the delivery of a 150 MeV clinical proton pencil beam to a tissue-equivalent plastic phantom. With the MCDE model we analyzed how the recorded PG interaction data changed as two characteristics of the DAQ electronics of a CC were changed: (1) the number of data readout channels; and (2) the active charge collection, readout, and reset time. As the proton beam dose rate increased, the number of recorded PG single-, double-, and triple-scatter events decreased by a factor of 60× for the current DAQ configuration of the CC. However, as the DAQ readout channels were increased and the readout/reset timing decreased, the number of recorded events decreased by <5× at the highest clinical dose rate. The increased number of readout channels and reduced readout/reset timing also resulted in higher quality recorded data. That is, a higher percentage of the recorded double- and triple-scatters were "true" events (caused by a single incident gamma) and not "false" events (caused by multiple incident gammas). The increase in the number and the quality of recorded data allowed higher quality PG images to be reconstructed even at the highest clinical dose rates.

16.
Front Phys ; 102022 Apr.
Article in English | MEDLINE | ID: mdl-36119562

ABSTRACT

We studied the application of a deep, fully connected Neural Network (NN) to process prompt gamma (PG) data measured by a Compton camera (CC) during the delivery of clinical proton radiotherapy beams. The network identifies 1) recorded "bad" PG events arising from background noise during the measurement, and 2) the correct ordering of PG interactions in the CC to help improve the fidelity of "good" data used for image reconstruction. PG emission from a tissue-equivalent target during irradiation with a 150 MeV proton beam delivered at clinical dose rates was measured with a prototype CC. Images were reconstructed from both the raw measured data and the measured data that was further processed with a neural network (NN) trained to identify "good" and "bad" PG events and predict the ordering of individual interactions within the good PG events. We determine if NN processing of the CC data could improve the reconstructed PG images to a level in which they could provide clinically useful information about the in vivo range and range shifts of the proton beams delivered at full clinical dose rates. Results showed that a deep, fully connected NN improved the achievable contrast to noise ratio (CNR) in our images by more than a factor of 8x. This allowed the path, range, and lateral width of the clinical proton beam within a tissue equivalent target to easily be identified from the PG images, even at the highest dose rates of a 150 MeV proton beam used for clinical treatments. On average, shifts in the beam range as small as 3 mm could be identified. However, when limited by the amount of PG data measured with our prototype CC during the delivery of a single proton pencil beam (~1 × 109 protons), the uncertainty in the reconstructed PG images limited the identification of range shift to ~5 mm. Substantial improvements in CC images were obtained during clinical beam delivery through NN pre-processing of the measured PG data. We believe this shows the potential of NNs to help improve and push CC-based PG imaging toward eventual clinical application for proton RT treatment delivery verification.

17.
Sensors (Basel) ; 22(18)2022 Sep 08.
Article in English | MEDLINE | ID: mdl-36146135

ABSTRACT

(1) Background: The Exradin W2 is a commercially available scintillator detector designed for reference and relative dosimetry in small fields. In this work, we investigated the performance of the W2 scintillator in a 10 MV flattening-filter-free photon beam and compared it to the performance of ion chambers designed for small field measurements. (2) Methods: We measured beam profiles and percent depth dose curves with each detector and investigated the linearity of each system based on dose per pulse (DPP) and pulse repetition frequency. (3) Results: We found excellent agreement between the W2 scintillator and the ion chambers for beam profiles and percent depth dose curves. Our results also showed that the two-voltage method of calculating the ion recombination correction factor was sufficient to correct for the ion recombination effect of ion chambers, even at the highest DPP. (4) Conclusions: These findings show that the W2 scintillator shows excellent agreement with ion chambers in high DPP conditions.


Subject(s)
Photons , Plastics , Radiometry/methods
18.
J Appl Clin Med Phys ; 23(9): e13712, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35808871

ABSTRACT

PURPOSE: To develop an automated workflow for rectal cancer three-dimensional conformal radiotherapy (3DCRT) treatment planning that combines deep learning (DL) aperture predictions and forward-planning algorithms. METHODS: We designed an algorithm to automate the clinical workflow for 3DCRT planning with field aperture creations and field-in-field (FIF) planning. DL models (DeepLabV3+ architecture) were trained, validated, and tested on 555 patients to automatically generate aperture shapes for primary (posterior-anterior [PA] and opposed laterals) and boost fields. Network inputs were digitally reconstructed radiographs, gross tumor volume (GTV), and nodal GTV. A physician scored each aperture for 20 patients on a 5-point scale (>3 is acceptable). A planning algorithm was then developed to create a homogeneous dose using a combination of wedges and subfields. The algorithm iteratively identifies a hotspot volume, creates a subfield, calculates dose, and optimizes beam weight all without user intervention. The algorithm was tested on 20 patients using clinical apertures with varying wedge angles and definitions of hotspots, and the resulting plans were scored by a physician. The end-to-end workflow was tested and scored by a physician on another 39 patients. RESULTS: The predicted apertures had Dice scores of 0.95, 0.94, and 0.90 for PA, laterals, and boost fields, respectively. Overall, 100%, 95%, and 87.5% of the PA, laterals, and boost apertures were scored as clinically acceptable, respectively. At least one auto-plan was clinically acceptable for all patients. Wedged and non-wedged plans were clinically acceptable for 85% and 50% of patients, respectively. The hotspot dose percentage was reduced from 121% (σ = 14%) to 109% (σ = 5%) of prescription dose for all plans. The integrated end-to-end workflow of automatically generated apertures and optimized FIF planning gave clinically acceptable plans for 38/39 (97%) of patients. CONCLUSION: We have successfully automated the clinical workflow for generating radiotherapy plans for rectal cancer for our institution.


Subject(s)
Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Rectal Neoplasms , Automation , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Rectal Neoplasms/radiotherapy
19.
Article in English | MEDLINE | ID: mdl-35221402

ABSTRACT

Research on proton-based imaging systems aims to improve treatment planning, internal anatomy visualization, and patient alignment for proton radiotherapy. The purpose of this study was to demonstrate a new proton radiography system design consisting of a monolithic plastic scintillator volume and two optical cameras for use with scanning proton pencil beams. Unlike the thin scintillating plates currently used for proton radiography, the plastic scintillator volume (20 × 20 × 20 cm3) captures a wider distribution of proton beam energy depositions and avoids proton-beam modulation. The proton imaging system's characteristics were tested using image uniformity (2.6% over a 5 × 5 cm2 area), stability (0.37%), and linearity (R2 = 1) studies. We used the light distribution produced within the plastic scintillator to generate proton radiographs via two different approaches: (a) integrating light by using a camera placed along the beam axis, and (b) capturing changes to the proton Bragg peak positions with a camera placed perpendicularly to the beam axis. The latter method was used to plot and evaluate relative shifts in percentage depth light (PDL) profiles of proton beams with and without a phantom in the beam path. A curvelet minimization algorithm used differences in PDL profiles to reconstruct and refine the phantom water-equivalent thickness (WET) map. Gammex phantoms were used to compare the proton radiographs generated by these two methods. The relative accuracies in calculating WET of the phantoms using the calibration-based beam-integration (and the PDL) methods were -0.18 ± 0.35% (-0.29 ± 3.11%), -0.11 ± 0.51% (-0.15 ± 2.64%), -2.94 ± 1.20% (-0.75 ± 6.11%), and -1.65 ± 0.35% (0.36 ± 3.93%) for solid water, adipose, cortical bone, and PMMA, respectively. Further exploration of this unique multicamera-based imaging system is warranted and could lead to clinical applications that improve treatment planning and patient alignment for proton radiotherapy.

20.
Clin Colorectal Cancer ; 21(3): 204-211, 2022 09.
Article in English | MEDLINE | ID: mdl-35125321

ABSTRACT

BACKGROUND: Short course radiation-based total neoadjuvant therapy can improve disease-free survival for patients with high-risk locally advanced rectal cancer. Tumors that involve or threaten the circumferential resection margin have a particularly high risk of local recurrence. Intraoperative radiation therapy enables treatment escalation at the threatened or involved margin at the time of surgery. PATIENTS AND METHODS: Patients with rectal adenocarcinoma treated with preoperative short course radiotherapy-based total neoadjuvant therapy and intraoperative radiation at the time of surgery were identified. All patients had a threatened or involved circumferential resection margin on magnetic resonance imaging at the time of diagnosis. Treatment details, radiation toxicities, postoperative complications and oncologic outcomes were recorded. RESULTS: Ten patients received intraoperative radiation after short course radiation-based total neoadjuvant therapy. All patients had an involved or threatened circumferential resection margin, 60% had extramural venous invasion, and 60% had positive lateral pelvic lymph nodes. Seven patients had negative surgical margins (≥ 2 mm), and 3 patients had an R1 resection with radial margins < 2 mm. The median [IQR] length of hospitalization after surgery was 11 [7-14] days. Three patients required readmission and 2 patients required reoperation due to complications including anastamotic leak and abscess. With a median follow up of 19.5 months postoperatively, no patient developed a pelvic recurrence, and 6 patients developed distant recurrences. CONCLUSIONS: The use of intraoperative radiation after a short course radiotherapy-based neoadjuvant therapy is safe and feasible. Further data are needed to determine whether the addition of intraoperative radiation improves local recurrence rates over preoperative radiation alone.


Subject(s)
Adenocarcinoma , Rectal Neoplasms , Adenocarcinoma/pathology , Humans , Margins of Excision , Neoadjuvant Therapy/adverse effects , Neoplasm Recurrence, Local/epidemiology , Neoplasm Recurrence, Local/pathology , Neoplasm Staging , Rectal Neoplasms/pathology , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...