Ann Vasc Surg ; 59: 231-236, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31009711

ABSTRACT

BACKGROUND: The procedure aims to show our results with a novel nontumescent, nonthermal technique to treat varicose veins. The V-block occlusion stent is a minimally invasive device for treating reflux of the great saphenous vein (GSV). It is an office-based procedure that does not require tumescence anesthesia. The V-block stent is a self-expandable device that functions as a vein occluder and blood clot trap. Once the V-block is in place, further treatment of the saphenous vein such as ultrasound-guided sclerotherapy can be performed. The V-block device is intended to eliminate the possibility of forwarding passage of clot and sclerosant (embolization) to the deep and pulmonary circulations. METHODS: Patients were treated in an outpatient setting with the V-block occluding device. Follow-up was performed using duplex ultrasound to assess occlusion of the saphenous vein as well as the Aberdeen Varicose Vein Questionnaire and Venous Severity Scoring to determine changes in quality of life after the procedure. Patients were followed up at 1 week, 1 month, and 3 months after V-block placement. Duplex scanning was performed to confirm GSV occlusion at all follow-up visits. After deployment of the occlusion stent, a maximum of 2% polidocanol foam was injected with a double barrel syringe which simultaneously evacuated blood from the greater saphenous vein. Follow-up assessment for safety included evaluation of potential complications, device migration, and potential injury at the deployment site. RESULTS: Fifty-one symptomatic subjects with documented GSV reflux were enrolled in the study. Complete occlusion of the GSV was achieved in 98% of the patients during the 7-day postprocedural visit. There was no injury at the deployment site. No migration of the V-block device was observed. No deep vein thrombosis or any other complication was recorded. One patient of the 50 patients and 51 procedures experienced an adverse event, phlebitis that resolved under conservative therapy within 4 days with no residual effect. There was a significant improvement in the Aberdeen Vein quality of life measurements and the pain scores. After 3 years, 18 patients were willing to undergo a duplex follow-up examination. The occlusion rate after 3 years was 77.8. There were no device-related complications after this period. CONCLUSIONS: The study demonstrated a good safety and performance profile without any major adverse events. The primary end point of vein occlusion and obliteration was met.


Subject(s)
Endovascular Procedures/instrumentation , Polidocanol/administration & dosage , Saphenous Vein , Sclerosing Solutions/administration & dosage , Sclerotherapy/instrumentation , Stents , Varicose Veins/therapy , Aged , Endovascular Procedures/adverse effects , Female , Humans , Male , Middle Aged , Polidocanol/adverse effects , Prosthesis Design , Quality of Life , Retrospective Studies , Saphenous Vein/diagnostic imaging , Saphenous Vein/physiopathology , Sclerosing Solutions/adverse effects , Sclerotherapy/adverse effects , Surveys and Questionnaires , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Duplex , Ultrasonography, Interventional , Varicose Veins/diagnostic imaging , Varicose Veins/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...