Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Radiat Oncol ; 17(1): 203, 2022 Dec 09.
Article in English | MEDLINE | ID: mdl-36494834

ABSTRACT

BACKGROUND: For patients with a higher burden of localized prostate cancer, radiation dose escalation with brachytherapy boosts have improved cancer control outcomes at the cost of urinary toxicity. We hypothesize that a focal approach to brachytherapy boosts targeting only grossly visualized tumor volumes (GTV) combined with stereotactic radiotherapy will improve quality of life (QoL) outcomes without compromising cancer control. METHODS: 150 patients with intermediate or high-risk prostate cancer will be enrolled and randomized 1:1 in a cohort multiple randomized clinical trial phase 2 design. Patients are eligible if planned for standard-of-care (SOC) high dose rate (HDR) brachytherapy boost to radiotherapy (RT) with GTVs encompassing < 50% of the prostate gland. Those randomly selected will be offered the experimental treatment, consisting of focal HDR brachytherapy boost (fBT) of 13-15 Gy in 1 fraction followed by stereotactic radiotherapy (sRT) 36.25-40 Gy in 5 fractions to the prostate (+/- 25 Gy to the elective pelvis) delivered every other day. The primary endpoint is to determine if fBTsRT is superior to SOC by having fewer patients experience a minimally important decline (MID) in urinary function as measured by EPIC-26 at 1 and 2 years. Secondary endpoints include rates of toxicity measured by Common Terminology Criteria for Adverse Events (CTCAE), and failure-free survival outcomes. DISCUSSION: This study will determine whether a novel approach for the treatment of localized prostate cancer, fBTsRT, improves QoL and merits further evaluation. Trial registration This trial was prospectively registered in ClinicalTrials.gov as NCT04100174 as a companion to registry NCT03378856 on September 24, 2019.


Subject(s)
Brachytherapy , Prostatic Neoplasms , Radiosurgery , Male , Humans , Quality of Life , Brachytherapy/adverse effects , Prostatic Neoplasms/pathology , Radiosurgery/adverse effects , Dose Fractionation, Radiation , Radiotherapy Dosage
2.
Strahlenther Onkol ; 190(5): 467-71, 2014 May.
Article in English | MEDLINE | ID: mdl-24557058

ABSTRACT

BACKGROUND AND PURPOSE: The purpose of this work was to assess the stability of fiducial markers in the prostate bed and compared their use to surgical clips. PATIENTS AND METHODS: In this study, 3-4 gold fiducial markers were transrectally implanted in the prostate bed of 14 patients. The stability of the fiducial markers position (fiducial markers fixity) over an EBRT course was assessed. Furthermore, the advantages of the fiducial markers compared to the surgical clips were assessed and the interobserver variation between the two technologies was compared. RESULTS: The mean fiducial marker migration during a course of EBRT was small with 1.2 mm (SD ± 0.8 mm). Compared to fiducial markers, the matches with surgical clips were mismatched ≥ 2 mm in 68% of treatments. This discrepancy of > 2 mm was on average 3.7 ± 1.3 mm. There was less interobserver variability for matching of fiducial markers (0.8 ± 0.7 mm) than for surgical clips (2.0 ± 1.6 mm). CONCLUSION: Fiducial markers showed less interobserver variability in matching and less variation in position than surgical clips. Fiducial markers could ultimately help in reducing treatment margins.


Subject(s)
Fiducial Markers , Gold , Prostatectomy , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/surgery , Radioisotope Teletherapy/methods , Radiotherapy, Image-Guided/methods , Surgical Instruments , Foreign-Body Migration/etiology , Humans , Male , Neoplasm Grading , Neoplasm Staging , Observer Variation , Organs at Risk , Prostate , Prostatic Neoplasms/pathology , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Adjuvant , Retrospective Studies , Salvage Therapy , Tomography, X-Ray Computed
3.
Med Phys ; 35(7Part3): 3417, 2008 Jul.
Article in English | MEDLINE | ID: mdl-28512882

ABSTRACT

To develop a tomosynthesis-based dose assessment procedure that can be performed after an I-125 prostate seed implantation, while the patient is still under anaesthesia on the treatment table. Our seed detection procedure involves the reconstruction of a volume of interest based on the backprojection of 7 seed-only binary images acquired over an angle of 60° with an isocentric imaging system. A binary seed-only volume is generated by a simple thresholding of the volume of interest. Seeds positions are extracted from this volume with a 3D connected component analysis and a statistical classifier that determines the number of seeds in each cluster of connected voxels. A graphical user interface (GUI) allows to visualize the result and to introduce corrections, if needed. A phantom and a clinical study (24 patients) were carried out to validate the technique. A phantom study demonstrated a very good localization accuracy of (0.4+/-0.4) mm when compared to CT-based reconstruction. This leads to dosimetric error on D90 and V100 of respectively 0.5% and 0.1%. In a patient study with an average of 56 seeds per implant, the automatic tomosynthesis-based reconstruction yields a detection rate of 96% of the seeds and less than 1.5% of false-positives. With the help of the GUI, the user can achieve a 100% detection rate in an average of 3 minutes. This technique would allow to identify possible underdosage and to correct it by potentially reimplanting additional seeds. A more uniform dose coverage could then be achieved in LDR prostate brachytherapy.

SELECTION OF CITATIONS
SEARCH DETAIL
...